• 제목/요약/키워드: Drop analysis

검색결과 1,883건 처리시간 0.028초

Numerical Study on Mixing Performance of Straight Groove Micromixers

  • Hossain, Shakhawat;Kim, Kwang-Yong
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권3호
    • /
    • pp.227-234
    • /
    • 2010
  • Numerical analyses have been performed to investigate the effects of geometric parameters of a straight groove micromixer on mixing performance and pressure drop. Three-dimensional Navier-Stokes equations with two working fluids, water and ethanol have been used to calculate mixing index and pressure drop. A parametric study has been carried out to find the effects of the number of grooves per cycle, arrangement of patterned walls, and additional grooves in triangular dead zones between half cycles of grooves. The three arrangements of patterned walls in a micromixer, i.e., single wall patterned, both walls patterned symmetrically, and both walls patterned asymmetrically, have been tested. The results indicate that as the number of grooves per cycle increases the mixing index increases and the pressure drop decreases. The microchannel with both walls patterned asymmetrically shows the best mixing performance among the three different arrangements of patterned walls. Additional grooves confirm the better mixing performance and lower pressure drop.

돌출부를 갖는 평행평판의 최적 설계를 위한 층류강제대류 해석 (Analysis of laminar forced convection for optimal design of parallel plates with protrusions)

  • 이관수;박철균
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.129-136
    • /
    • 1998
  • Pressure drop and heat transfer characteristics of a periodically fully developed flow in the flat channel with protrusions are investigated. The effects of shape and location of protrusion on the pressure drop and heat transfer are numerically analyzed in the present study. Taguchi method is used to optimize these parameters. It is found that the ratio of the height of protrusion to channel height shows larger influence on the pressure drop and heat transfer than the ratio of the length of protrusion to module length. As the height of protrusion increases, pressure drop and heat transfer increase, but if the height of protrusion exceeds 2/3 of the channel height, there is a substantial pressure drop. The results also show that the optimal length and height of protrusion are half of the module length and half of the channel height, respectively.

  • PDF

농형 유도 발전기의 소프트 기동 특성 해석 (Soft Start-up Characteristics Analysis of Squirrel Cage Induction Generator)

  • 김종겸;박영진
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.103-107
    • /
    • 2016
  • In general, the voltage stability of induction generator is lower than synchronous generator. Induction generator has a number of advantages over the synchronous generator on the side of price and maintenance. So Induction generator has been applied to the small hydroelectric power of low output. Induction generator usually generates a high current during grid connection. The high current that occurs during grid connection can cause a voltage drop in the system. In order to increase the supply of the induction generator, it is necessary to propose a method of reducing high current. This paper proposes some method of the soft start to reduce voltage drop caused by the large starting current. soft-start method has high voltage drop effect than direct start method, control of firing angle can be increased the voltage drop effect.

Comparative Analysis of Maximum Vertical Reaction Force and Lower Limbs on Drop Landing between Normal and Flat Foot Group

  • Yoo, Kyung-Tae
    • 국제물리치료학회지
    • /
    • 제2권1호
    • /
    • pp.222-228
    • /
    • 2011
  • With comparison of maximum vertical reaction force and lower limb on drop landing between normal and flat foot group, this study is to provide fundamental data of the prevention of injury and the treatment of exercise which are frequently occurred on flat foot group's drop landing. The surface electrodes were sticked on lateral gastrocnemius muscle, medial gastrocnemius muscle, tibialis anterior and the drop landing on a force plate of 40cm was performed with a normal group who had no musculoskeletal disease and a flat foot group of 9 people who had feet examinations. Vertical reaction force were significantly statistically different between two groups(p<.001). Muscle activity of lower limbs in all three parts were not statistically different but showed high tendency on average in the flat foot group. The flat foot group had difficulties in diversification of impact burden and high muscle activity. Therefore, it was suggested that muscular strengthening of knee joints and plantar flexions of foot joints which were highly affected in impact absorption will be required.

LNG 저장탱크용 멤브레인의 충격거동에 관한 실험적 연구 (Experimental Study of Impact Behaviors of the Membrane for LNG Storage Tank)

  • 김영규;김청균
    • 한국안전학회지
    • /
    • 제10권4호
    • /
    • pp.68-74
    • /
    • 1995
  • This paper analyzes the behaviors of the membrane under drop impact loadings using the acoustic emission technique. The analysis is useful for evaluating the strength of the membrane as well as for studying its damping characterisics due to the corrugation and the ring knot. The membrane for LNG storage tank is basically composed linear and circular elements. Two membrane specimens have approximately same drop impact mass and same drop speed. Locan 320 system with piezoelectric sensor is used in the experimental measurement. Experimental results for the membranes indicated that AE siganls having higher energies were generated with increasing drop impact loadings. It was confirmed that the ring knot. membrane has high absorption of drop impact loadings in comparison with the flat membrane. These results are very important to reliable design and to improve the safey of the membrane components.

  • PDF

와류증폭기에서의 압력강하에 관한 고찰 (A Study on Pressure Drop in Vortex Amplifier)

  • 박준상
    • 한국유체기계학회 논문집
    • /
    • 제20권1호
    • /
    • pp.29-34
    • /
    • 2017
  • An analysis on pressure drop in vortex amplifier has been performed. Based on theoretical approach with flow physics on well-known firm ground from previous studies, two dimensional flow model, which is very useful to calculate pressure drop of vortex amplifier, is proposed. Parametric studies on inlet and outlet boundary conditions also have been performed so that it found the most influential parameter is the inlet swirl velocity condition. Finally, a simple formulation is given to calculate total pressure drop.

스크린 도어와 계단 통로 사이 압력 강하량에 따른 지하철 승강장 내부 열유동 특성 (Heat and Fluid Flow Characteristics in Subway Station Platform with Consideration of Pressure Drop between Screen Doors and Stair Passages)

  • 윤정배;김석완
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.21-28
    • /
    • 2006
  • In the present study, the analysis on heat and fluid flow in subway station platform is carried out by considering the pressure drop between screen doors and stair passages. To investigate the effect on the characteristics of heat and fluid flow of pressure drop, Numerical simulation is applied. The present results show a better cooling condition, in the case of without pressure drop.

  • PDF

A Study of Drop Handles Design

  • Cho, Sook-Kyung;Moon, Sun-Ok
    • 한국가구학회지
    • /
    • 제21권3호
    • /
    • pp.253-260
    • /
    • 2010
  • The drop handle in the Chosun-Dynasty played a role lifting up the cabinet and box which was attached to and besides this had the decoration function. The scope of this study should include the drop handles from the $18^{th}$ century up to now by investigating and analyzing their definition & function and furthermore the types of their designs. The object of the study was the drop handle having 2 golden fixing parts which are definitive difference from ring or loop, and the design typology of drop handle was concentrated on the handle part, and it can be classified in two types. The one is the figuration of bow, bat, bamboo, fish and bird and so on from the motive of nature on the handle part, and the other one is the drop handle of the simple ㄷ-shape, the temple-symbol shape or geometrical forms. According to the analysis of relics & literature from the past it was found that there were more quantitative nature-motive figurations than the geometrical forms. The nature-motive figurations were again classified in box-, bat-, cloud- bamboo-, fish- and bird-type, and the geometrical forms in ㄷ-shape, the temple-symbol shape and others. The cases applied to furniture are roughly divided into the front-attached type and the side-attached type. In comparison of the drop handle in the Chosun-Dynasty with that of modern times, ㄷ-shape and bow-type keep the long tradition of the drop handles despite of the constructive change partly. Ring-type is similar to the just ring or loop of the part and drop handle with one golden fixing part, while the knob-type shows almost same forms in the past as well as in the modern times. Which type among handles in the modern times has little connection with the past is the reclaimed type, and it was showed in the Chosun-Dynasty and also is showed up to now identically that the man-made hole on the front side of the drawer for the function as handle.

  • PDF

액체질소 냉각용 극저온 열교환기의 최적설계를 위한 열전달 및 압력강하 특성 분석 (An Analysis of Heat Transfer and Pressure Drop Characteristics for Optimum Design of Cryogenic Heat Exchanger used for Liquid Nitrogen Cooling)

  • 고지운;전동순
    • 설비공학논문집
    • /
    • 제30권1호
    • /
    • pp.24-32
    • /
    • 2018
  • In this paper, analytical studies were conducted to obtain optimal design factors and analysis parameters of liquid nitrogen cooling exchanger applied in cryogenic refrigerator. The target value of heat transfer rate was more than 1 kW and pressure drop was less than 40 kPa. Design factors of cryogenic heat exchanger included width of channel and configuration of paths. Analytical factors of liquid nitrogen cooling exchanger included temperatures of coolant header surface and inlet liquid nitrogen. The width and number of channels in the design parameters were 0.0050~0.0150 m and 4~8, respectively. The configuration of channel path was 4 ways. Temperatures of coolant header surface and inlet liquid nitrogen in analytical parameters were 74 to 78K and 82 to 86K, respectively. As result, the design factor and analysis parameter satisfying the target values were obtained. The biggest heat transfer rate was 1.36 kW with pressure drop of 32.26 kPa.

자동차 배기 매니폴드에 있어서의 열응력과 유동해석에 관한 연구 (Study on Thermal Stress and Flow Analysis at Exhaust Manifold of Car)

  • 조재웅;한문식
    • 한국자동차공학회논문집
    • /
    • 제22권2호
    • /
    • pp.23-28
    • /
    • 2014
  • This study investigates fluid flow and thermal stress at automotive exhaust manifolds as model 1 and 2. The maximum displacements happen at joint part connected with 4 pipes and upper middle of both parts in cases of model 1 and 2 respectively. At inner surface of the part connected with engine, maximum equivalent stresses of 991.85 and 698.96 MPa are shown in cases of model 1 and 2 respectively. As maximum velocities at the outlet at model 1 are shown at 19.46 and 14.61 m/s in cases of model 1 and 2 respectively, model 1 has more pressure drop than model 2. As result, model 2 has less pressure drop than 1. Model 2 has less deformation and stress than model 1. Model 2 has also less pressure drop than model 1. Therefore model 2 has more strength durability than model 1. This study result is applied with the design of safe automotive manifold and it can be useful to improve the durability by predicting prevention against the deformation due to exhaust gas.