• 제목/요약/키워드: Drop Out

검색결과 1,049건 처리시간 0.028초

빛 에너지 수확을 이용한 센서 노드 회로 (Sensor Node Circuit with Solar Energy Harvesting)

  • 서동현;조용민;우대건;윤은정;유종근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 추계학술대회
    • /
    • pp.371-374
    • /
    • 2013
  • 본 논문에서는 빛 에너지 하베스팅을 이용한 센서 노드 회로를 제안한다. 솔라셀에서 변환된 에너지는 PMU(Power Management Unit)를 통해 관리되고, 일정한 전압을 공급하기 위해 LDO(Low Drop Out Regulator)를 사용한다. LDO를 통해 공급된 전압으로 온도센서와 SAR ADC(Successive Approximate Register Analog-to-Digital Converter)를 구동시킨다. 이 회로는 0.35um CMOS 공정으로 설계되었다.

  • PDF

원추형 하단부 구조를 갖는 캡슐의 하나로와의 양립성시험 (Compatibility Test of the Capsule with Cone Shape Bottom Guide Structures to the HANARO Reactor)

  • 최명환;조만순;주기남;박승재;김봉구;강영환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.444-449
    • /
    • 2004
  • The design modification of bottom guide structures of the instrumented capsule, which is used for the irradiation test in the HANARO reactor, was required because of the trouble of the bottom guide arm's pin during irradiation. The previous structure with 3-pin arms was changed into the cone shape of one body. The specimens of the bottom end cap ring with three different sizes (${\Phi}68/70/72mm$) were designed and manufactured. The out-pile tests for the capsule with previous and new three bottom guide structures were performed in the one-channel flow test facilities. In order to evaluate the compatibility with HANARO and the structural integrity of the capsule, a loading/unloading, a pressure drop, a thermal performance, a vibration, and an endurance test were conducted. From out-pile test results, the capsule with the cone shape bottom guide structures was found to be more stable than the previous structure and the optimized size of the bottom guide structure selected was 70mm in diameter. It is expected that the new bottom guide structures will be applicable to all material and special capsules which will be designed and manufactured for the irradiation tests in the future.

  • PDF

LDO 레귤레이터의 파괴방지 및 효율성을 위한 ESD 보호회로 설계에 대한 연구 (A Study on the Design of ESD Protection Circuit for Prevention of Destruction and Efficiency of LDO Regulator)

  • 이정민;권상욱;백승환;구용서
    • 전기전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.258-264
    • /
    • 2023
  • 본 논문에서는 부하전류에 따라 LDO(Low Drop Out) 레귤레이터의 효과적인 동작과 파괴 방지를 위해 ESD(Electro Static Discharge) 보호회로를 내장한 LDO 레귤레이터를 제안한다. 제안하는 LDO 레귤레이터는 additional feedback current 회로구조를 이용하여 LDO 레귤레이터의 출력전압에 따라 더욱 효과적으로 패스 트랜지스터의 게이트 노드 전압을 조절할 수 있다. 또한 기존의 ESD 보호소자에 P+ bridge를 추가하여 SCR 루프 상의 전류 이득을 감소시켜 홀딩 전압을 약 2V 가량 높인 새로운 구조를 내장하여 ESD 상황에 대해 높은 신뢰성을 가질 것으로 예상된다.

가솔린 자동차의 희박연소시스템 적용을 위한 연료공급 최적화에 관한 연구 (I) - 가솔린 인젝터의 연료분열특성에 관한 연구 - (A Study on the Optimization of Fuel Metering for the Lean Combustion System in a Gasoline Engine (I))

  • 윤석주;조대진;방두열
    • 한국분무공학회지
    • /
    • 제3권3호
    • /
    • pp.33-41
    • /
    • 1998
  • In recently, a study on the lean combustion is investigated intensively, because it is expected that this method may decrease the harmful exhaust gas and improve fuel economy in gasoline engine. The problems of lean combustion system in gasoline engine are ignition difficulty, misfire and instability of combustion. The investigation on the optimization of fuel metering and the control of mixing gas flow may be critical to improve the performance of lean combustion. In the fuel injection gasoline engine, the formation of mixture influences strongly on the engine performance such that the importance of fuel metering system becomes apparent. First of all, a study on the fuel breakup characteristics of gasoline fuel injector was carried out in this paper. Fuel injectors are pintle and 4hole-2spray type. The purpose of this study is to clarify the atomization mechanism of spray injected into atomosphere field through electronic controlled-fuel injectors, and to analyze spray characteristics such as drop size distribution and mean drop diameter produced at fuel injector. In this paper, the spray development is observed by taking photograps using 80mm still-camera system, and drop sizes are measured by PMAS. From these experiment, spray pattern injected from gasoline fuel injectors was investigated clearly. Also, it was found that SMD and drop size distribution of injected fuel spray from gasoline fuel injectors.

  • PDF

멤스기술을 이용한 가상밸브가 있는 새로운 잉크젯 헤드 개발 (Development of a new thermal inkjet head with the virtual valve fabricated by MEMS technology)

  • 배기덕;백석순;신종우;임형택;신수호;오용수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1892-1897
    • /
    • 2003
  • A new thermal inkjet printer head on SOI wafer with virtual valve was proposed. It was composed of two rectangular heaters with same size. So we could call it T-jet(Twin jet). T-jet has a lot of merits. It has the advantage of being fabricated with one wafer and is easy to change the size of chamber, nozzle, restrictor and so on. However, above all, It is the best point that T-jet has a virtual valve. And it was manufactured on SOI wafer. The chamber was formed in its upper silicon whose thickness was 40um. The chamber's bottom layer was silicon dioxide of SOI wafer and two heaters were located underneath the chamber's ceiling. And the restirctor was made beside the chamber. Nozzle was molded by process of Ni plating. Ni was 30um thick. Nozzle ejection test was performed by printer head having 56 nozzles in 2 columns with 600NPI(nozzle per inch) and black ink. It measured a drop velocity of 12m/s, a drop volume of 30pl, and a maximum firing frequency of 12KHz for single nozzle ejection. Throwing out the ink drop in whole nozzles at the same time, it was observed that the uniformity of the drop velocity and volume was less than 4%.

  • PDF

출산에 따른 30대 여성의 하반신 형태 연구 (Lower Body Type of Women in their Thirties after Childbirth)

  • 이정란;홍은숙;백경자
    • 한국의류산업학회지
    • /
    • 제10권6호
    • /
    • pp.979-988
    • /
    • 2008
  • The purpose of this study is to analyze the lower body size and forms of married women in their thirties who have experienced pregnancy and parturition. Their measurements derived from the direct anthropometry and indirect photographic measures were compared to those of 20's. Improving consumer satisfaction for missy brand, especially in fitness of skirt and pants, some lower body classification were presented. The results were as follows : 1. The characteristics of lower body showed many differences by individuals especially in depth, girth, length and angle measures rather than height and breadth measures. Many items including index, calculations and angles revealed significant differences compared to those of 20's. Several breadth items, crotch length had distinct increase than those of women in twenties. Flattened buttocks side silhouette from waist to hip, buttocks drooping and decrease of inclination implied the influence of pregnancy, parturition and aging. 2. We hardly find out sizing system differences between missy brand and miss brand. Based on waist and hip girth measurements of subjects, sizing system of missy apparel wasn't suitable for their body size. Excessive drop(hip girth-waist girth) of missy brands, 25~30 cm, was almost the same to the drop of miss brands. 3. To improve the size satisfaction of missy women, we classified the lower body into 5 types according to drop, buttocks angle and hip length. Type 1 was small waist with large buttocks projection, and hip length was close to an average. Type 2 was small waist with medium buttocks projection, and the hip length was close to an average. Type 3 was medium waist, with average projection of the buttocks and hip length. Type 4 was large waist, projection of the buttocks and the hip length were close to an average. Type 5 was large waist, projection of the buttocks was small and the hip length was close to an average.

캡슐 하단부 구조변경에 따른 압력강하 및 진동특성 (Pressure Drop and Vibration Characteristics of the Capsule with the Modification of Bottom Structures)

  • 최명환;주기남;조만순;김봉구
    • 한국소음진동공학회논문집
    • /
    • 제15권12호
    • /
    • pp.1370-1377
    • /
    • 2005
  • The bottom structure of an instrumented capsule is a part which is joined at the receptacle of the flow tube in the reactor in-core. A geometrical change of the bottom structure has an effect on the pressure drop and the vibration of the capsule. The out-pile test to evaluate the structural integrity of the material capsule called 04M-17U was performed by using a single channel and a half core test loop. From the pressure drop test, the optimized diameter of the cone shape's bottom structure which satisfies HANARO's flow requirement (19.6 kg/s) is 71 mm. The maximum displacement of the capsule measured at the half core test loop is lower than 1.0 mm. From the analysis results, it is found that the test hole will not be interfered with near the flow tubes because its displacement due to the cooling water is very small at 0.072 mm. The fundamental frequency of the capsule under water is 9.64 Hz. It is expected that the resonance between the capsule and the fluid flow due to the cooling water in HANARO's in-core will not occur. Also, the new bottom structure of a solid cone shape with 71 mm in diameter will be applicable to the material and special capsules in the future.

수평 평활관내 $CO_2$ 증발열전달 및 압력강하에 관한 연구 (Study on $CO_2$ Evaporation Heat Transfer and Pressure Drop in a Horizontal Smooth Tube)

  • 이상재;최준영;이재헌;권영철
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.615-621
    • /
    • 2007
  • Experimental study on the heat transfer characteristics of $CO_2$ in a horizontal smooth tube was carried out to investigate the heat transfer coefficient and pressure drop during evaporation of $CO_2$. The experiment apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes ($200{\sim}1200kg/m^2s$), heat flukes ($10{\sim}100kW/m^2$) and saturation temperatures (-5, 0, $5^{\circ}C$). With increasing the heat flux, the evaporation heat transfer coefficient increased. But the variation of the heat transfer coefficient on the increase of the mass flux was not large. And the significantly drops of the heat transfer coefficient was observed at any heat flux and mass flux because of the change of the flow pattern in the tube. With increasing the saturation temperature, the heat transfer coefficient increased due to the promotion of a nucleate boiling. The measured pressure drop during evaporation increased with increasing the mass flux and decreasing the saturation temperature.

유체-구조 연성해석 기반 해저케이블 위해인자의 수중낙하 특성 비교 (Comparison of Underwater Drop Characteristics for Hazard Apparatuses on Subsea Cable Using Fluid-Structure Interaction Analysis)

  • 장경호;김정훈;송창용
    • 한국해양공학회지
    • /
    • 제32권5호
    • /
    • pp.324-332
    • /
    • 2018
  • It is known that damages to the subsea cables used for electric power transmission between islands and countries, including renewable energy from offshore wind power, current, tides, etc., cost much to restore, which causes social and economic losses. Various types of fishing rigs and anchors have been reported to be the greatest hazards to subsea cables. It is possible to design and construct a suitable protection facility for a subsea cable by precisely estimating the underwater behavior of such hazardous apparatuses. In this study, numerical simulations of the underwater behaviors of various hazardous apparatuses were carried out using fluid-structure interaction (FSI) analysis as a basic study to simulate the actual behavior phenomena of hazardous apparatuses in relation to a subsea cable. In addition, the underwater drop characteristics according to the types of hazardous apparatuses were compared. In order to verify the accuracy of the FSI analysis method used in this study, we compared the test results for underwater drops of a steel ball bearing. Stock anchors, stockless anchors, and rocket piles, which were actually reported to be the cases of damage to subsea cables along the southwest coast of Korea, were considered as the hazardous apparatuses for the numerical simulations. Each hazardous apparatus was generated by a Lagrangian model and coupled with the fluid domain idealized by the Eulerian equation to construct the three-dimensional FSI analysis model. The accuracy of the numerical simulation results was verified by comparing them with the analytical solutions, and the underwater drop characteristics according to the types of hazard apparatuses were compared.

직접 접촉식 4단 유동층 열교환기의 압력손실 및 열전달 특성 (The Pressure Drop and Heat Transfer Characteristics of a Direct Contact 4-Stage Fluidized Bed Heat Exchanger)

  • 임동렬;박상일;전광민
    • 대한기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.325-335
    • /
    • 1992
  • In this work, direct contact 4-stage fluidized bed heat exchanger is experimentally studied to develop a new type of heat exchanger which recovers the energy contained in the high temperature waste gas exhausted from the industrial furnaces. A sand is used as a heat transfer medium in this experiment. To determine the optimum operating condition, 11 different perforated plates which have a different free area ratio with different hole diameter are used in the experiment. From the room temperature experiment, the pressure drop which is caused by fluidized bed formation is observed. The high temperature experiment is carried out to seek the optimum operating condition of high heat efficiency at low heat exchanger operation cost. The results of experiment are as following. The pressure drop in the high temperature condition can be predicted from the results of the room temperature experiment. And Nusselt number becomes smaller due to the increased interference between sand particles as Reynolds number increases when the dilute phase fluidized beds are formed in nigh temperature condition. But heat transfer amount through the total sand surface area become larger due to the large resident amount of sand. Considering the heat transfer amount and the heat exchanger operation cost, perforated plates which have either a 30% or 35% of free area ratio with 15mm of hole diameter are best fitted for our goal of this work. The values of .phi. which is a dimensionless number representing the absorption heat amount per unit sand rate are in the range from 0.4 to 0.5, when Reynolds number of waste gas ranges from 25-30 with these perforated plates.