CFD Analysis to Estimate Drop Time and Impact Velocity of a Control Rod Assembly in the Sodium Cooled Faster Reactor (소듐냉각고속로 제어봉집합체의 낙하시간 및 충격속도 예측을 위한 CFD 해석)

  • Kim, JaeYong;Yoon, KyungHo;Oh, Se-Hong;Ko, SungHo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.5-11
    • /
    • 2015
  • In a pressurized water reactor (PWR), control rod assembly (CRA) falls into the guide tubes of a fuel assembly due to gravity for scram. Various theoretical approaches and numerical analyses have been performed because its shape is simple and its design was completely developed several decades ago. A control rod assembly for a sodium-cooled faster reactor (SFR) which is geometrically more complicated is being actively developed in Korea nowadays. Drop time and impact velocity of a CRA are important parameters with respect to reactivity insertion time and the mechanical robustness of a CRA and a guide duct. In this paper, computational method considering simultaneously the equation of motion for rigid body and the Navier-Stokes equations for fluid is suggested and verified by comparison with theoretical analysis results. Through this valuable CFD analysis method, drop time and impact velocity of initially designed SFR CRA are evaluated before performing scram tests with it.

Combination of MSAT and Korean Medicine for Managing Foot Drop Due to Lumbar Disc Herniation: Case Report (족하수 환자의 복합 한의진료 경과 및 삶의 질 변화: 증례보고)

  • Park, Ji-won;Jeong, Wu-Jin;Huh, Hyo-Seung;Hong, Hae-Won;Koo, Ji-eun
    • Korean Journal of Acupuncture
    • /
    • v.38 no.3
    • /
    • pp.189-195
    • /
    • 2021
  • Foot drop due to lumbar disc herniation is perceived to be an indication for surgery. A 44-year-old male presented with motor deficit in left ankle dorsiflexion along with radiating pain and paraesthesia. Motion Style Acupuncture Therapy (MSAT) was administered on the left side every other day. Acupuncture and Chuna were performed daily. Herbal medicine was taken 3 times a day. His symptoms rapidly improved throughout treatment, verified by decreased Numeric Rating Scale (NRS), Oswestry Disability Index (ODI), increased 5-level EuroQol-5 Dimension (EQ-5D-5L) scores, and improved motor grades. We suggest that a combination of MSAT with traditional Korean medicine could be a favorable option for foot drop in LDH patients in terms of rapid pain reduction and the improvement of quality of life.

The Effects of Gaze Direction on the Stability and Coordination of the Lower Limb Joint during Drop-Landing (드롭랜딩 시 시선 방향의 차이가 하지관절의 안정성과 협응에 미치는 영향)

  • Kim, Kewwan;Ahn, Seji
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.2
    • /
    • pp.126-132
    • /
    • 2021
  • Objective: The purpose of this study was to investigate how three gaze directions (bottom, normal, up) affects the coordination and stability of the lower limb during drop landing. Method: 20 female adults (age: 21.1±1.1 yrs, height: 165.7±6.2 cm, weight: 59.4±5.9 kg) participated in this study. Participants performed single-leg drop landing task on a 30 cm height and 20 cm horizontal distance away from the force plate. Kinetic and kinematic data were obtained using 8 motion capture cameras and 1 force plates and leg stiffness, loading rate, DPSI were calculated. All statistical analyses were computed by using SPSS 25.0 program. One-way repeated ANOVA was used to compared the differences between the variables in the direction of gaze. To locate the differences, Bonferroni post hoc was applied if significance was observed. Results: The hip flexion angle and ankle plantar flexion angle were significantly smaller when the gaze direction was up. In the kinetic variables, when the gaze direction was up, the loading rate and DPSI were significantly higher than those of other gaze directions. Conclusion: Our results indicated that decreased hip and ankle flexion angles, increased loading rate and DPSI when the gaze direction was up. This suggests that the difference in visual information can increase the risk of injury to the lower limb during landing.

Electroacupuncture Treatment for Post-Stroke Foot Drop: A Systemic Review of Randomized Controlled Trials

  • Hye Jeong Jo;Go Eun Chae;Hyun Woo Kim;Young Jin Lee;Ahra Koh;Ji Eun Choi;So Jung Kim;Woo Young Kim
    • Journal of Acupuncture Research
    • /
    • v.41 no.2
    • /
    • pp.75-86
    • /
    • 2024
  • A review of randomized controlled trials (RCTs) using electroacupuncture (EA) to treat patients with foot drop was performed to analyze the effectiveness of EA for this condition. Relevant studies (n = 183) from 7 databases (Cochrane Library, Excerpta Medica Database, PubMed, China National Knowledge Infrastructure, Korean Studies Information Service System, Research Information Sharing Service, and Oriental Medicine Advanced Searching Integrated System) were selected based on the inclusion and exclusion criteria, and 12 RCTs met the selection criteria. In all 12 studies, EA showed significantly positive changes. In most indicators, positive changes were observed in the EA group compared with that in the control group. Significant increases were confirmed in muscle strength-related indicators such as the Fugl-Meyer motor scale, surface electromyography, active range of motion, and gait-related indicators such as the Tinetti score, maximum walking speed, and Berg balance scale. No notable adverse events were reported. EA is suggested as an effective treatment for post-stroke foot drop; however, more RCTs are required.

Optimization for Drop and Lift of the SONAR Under the Limited Installment Space Using the GA (GA를 이용한 제한된 설치환경 하에서의 소나 투하 및 인양 장비의 최적화)

  • Park, Seong-Hak;Chung, Won-Jee;Kim, Hyo-Gon;Choi, Jong-Kap
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.5
    • /
    • pp.321-328
    • /
    • 2016
  • Cranes are generally used to drop or lift equipment or materials. The present study focuses on equipment used for dropping and lifting the sonar system for undersea exploration. This study deals with a GA-based MATLAB$^{(R)}$ simulation for the design optimization of a new overboarding prototype with a two degree-of-freedom mechanism, including a parallelogram link, which is efficient in sonar system operation and maintenance. First, the strengths and weaknesses of the existing overboarding mechanisms are analyzed. The new mechanism to solve these problems is then suggested. For the proposed mechanism, the GA-based MATLAB$^{(R)}$ simulation technique is applied to the proposed mechanism to optimize the link lengths and the actuator lengths. By doing this, the mechanism cannot interfere in the hull's internal environment. Hence, the work range of motion (ROM) is satisfied, and good torque-angle properties are obtaind. The developed technology will be helpful in calculating the maximized output torque of the actuator for the application in practice using a similar type of the proposed mechanism.

Shock Attenuation Mechanism in Drop Landing According to the Backpack Weight Changes (드롭랜딩 시 backpack 중량 변화에 따른 충격 흡수 기전)

  • Choi, Chi-Sun;Nam, Ki-Jeong;Shin, In-Sik;Seo, Jung-Suk;Eun, Seon-Deok;Kim, Suk-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.25-35
    • /
    • 2006
  • The purpose of this study was to investigate the shock attenuation mechanisms while varying the loads in a backpack during drop landing. Ten subjects (age: $22.8{\pm}3.6$, height: $173.5{\pm}4.3$, weight: $70.4{\pm}5.2$) performed drop landing under five varying loads (0, 5kg. 10kg. 20kg. 30kg). By employing two cameras (Sony VX2100) the following kinematic variables (phase time, joint rotational angle and velocity of ankle, knee and hip) were calculated by applying 2D motion analysis. Additional data, i.e. max vertical ground force (VGRF) and acceleration, was acquired by using two AMTI Force plates and a Noraxon Inline Accelerometer Sensor. Through analysing the power spectrum density (PSD), drop landing patterns were classified into four groups and each group was discovered to have a different shock attenuation mechanism. The first pattern that appeared at landing was that the right leg absorbed most of the shock attenuation. The second pattern to appear was that subject quickly transferred the load from the right leg to the left leg as quickly as possible. Thus, this illustrated that two shock attenuation mechanisms occurred during drop landing under varying load conditions.

Case Study on the Physical Characteristics of Precipitation using 2D-Video Distrometer (2D-Video Distrometer를 이용한 강수의 물리적 특성에 관한 사례연구)

  • Park, Jong-Kil;Cheon, Eun-Ji;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.25 no.3
    • /
    • pp.345-359
    • /
    • 2016
  • This study analyze the synoptic meteorological cause of rainfall, rainfall intensity, drop size distribution(DSD), fall velocity and oblateness measured by the 2D-Video distrometer(2DVD) by comparing two cases which are heavy rainfall event case and a case that is not classified as heavy rainfall but having more than $30mm\;h^{-1}$ rainrate in July, 2014 at Gimhae region. As a results; Over the high pressure edge area where strong upward motion exists, the convective rain type occurred and near the changma front, convective and frontal rainfall combined rain type occurred. Therefore, rainrate varies based on the synoptic meteorological condition. The most rain drop distribution appeared in the raindrops with diameters between 0.4 mm and 0.6 mm and large particles appeared for the convective rain type since strong upward motion provide favorable conditions for the drops to grow by colliding and merging so the drop size distribution varies based on the location or rainfall types. The rainfall phases is mainly rain and as the diameter of the raindrop increase the fall velocity increase and oblateness decrease. The equation proposed based on the 2DVD tends to underestimated both fall velocity and oblateness compared with observation. Since these varies based on the rainfall characteristics of the observation location, standard equation for fall velocity and oblateness fit for Gimhae area can be developed by continuous observation and data collection hereafter.

CFD Analysis of Axial Flow Cyclone Separator for Subway Station HVAC System (지하역사 공기조화기에 적용 가능한 미세먼지 제거용 사이클론의 수치해석적 연구)

  • Kim, Jin-Kwan;Kim, Ho-Joong;Lee, Myung-Jun;Kim, Tae-Sung;Kwon, Soon-Bark
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.546-550
    • /
    • 2008
  • In this study, 3-dimensional Computational Fluid Dynamics (CFD) analysis was induced to simulate air flow and particle motion in the axial flow cyclone separator. The commercialized CFD code FLUENT was used to visualize pressure drop and particle collection efficiency inside the cyclone. We simulated 4 cyclone models with different shape of vane, such as turning angle or shape of cross section. For the air flow simulation, we calculated the flow field using standard ${\kappa}-{\varepsilon}$ turbulence viscous model. Each model was simulated with different inlet or outlet boundary conditions. Our major concern for the flow filed simulation was pressure drop across the cyclone. For the particle trajectory simulation, we adopted Euler-Lagrangian approach to track particle motion from inlet to outlet of the cyclone. Particle collection efficiencies of various conditions are calculated by number based collection efficiency. The result showed that the rotation angle of the vane plays major roll to the pressure drop. But the smaller rotation angle of vane causes particle collection efficiency difference with different inlet position.

  • PDF

Effect of Toe Headings on the Biomechanics of Knee Joint in Drop Landing (드롭 랜딩에서 발끝자세가 무릎관절 운동역학에 미치는 영향)

  • Joo, Ji-Yong;Kim, Young-Kwan;Kim, Jae-Pil
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.2
    • /
    • pp.121-129
    • /
    • 2014
  • The purpose of this study was to investigate the effect of the toe headings on the biomechanics of knee joint in drop landing in an attempt to find the potential risk of non-contact anterior cruciate ligament (ACL) injury. Seventeen male college students ($20.5{\pm}1.1$ yrs; $175.2{\pm}6.4$ cm; $68.8{\pm}5.8$ kg), having no neuromuscular injury within an year, participated in this study. Three different toe headings such as toe-in (TI), neutral (N), and toe-out (TO) positions were tested. Motion capturing system consisting of eight high speed cameras and two force platforms were used to collect three-dimensional motion data and ground reaction force data during landing. Results indicated joint angles and peak joint moments were significantly affected by the toe headings. TI position produced larger valgus angle due to reduce knee distance in addition to higher flexion and valgus moment than other positions, which was somewhat vulnerable to the potential risk of non-contact ACL injury. TO position caused the largest internal rotation angle with smaller joint moments. Therefore, it is recommended that athletes need to land on the ground with neutral toe-heading position as possible in order to minimize the potential risk of non-contact ACL injury.

Clinical Study on 2 Cases of Patients of Common Peroneal Nerve Palsy(Foot Drop) Improved by Motion Style Treatment (Motion Style Treatment로 호전된 족하수 환자 2례 보고)

  • Lee, Jin-Ho;Park, Jong-Min;Jung, Sung-Yup;Kim, Sung-Yong;Shin, Joon-Shik;Park, Won-Sang
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.6 no.1
    • /
    • pp.119-126
    • /
    • 2005
  • The purpose of this study is to report the patients with common peroneal nerve palsy, who improved by motion style treatment.(M.S.T.) The clinical study on 2 case of patients with herniation of nucleus pulposus, L4-5, L5-S1 combined foot drop, who had been hospitalized in Ja-Seng Oriental Hospital. We checked the motor grade and subjective improvement at interval of 3days under the treatment of M.S.T. After 2-3 weeks of treatment, the movement and power of ankle joint improved to nearly normal range. The subjective improvement was 70% compared with Rt. ankle and range of active motion increased from Gr.1-2 to Gr.4

  • PDF