• 제목/요약/키워드: Driving Cycle

검색결과 297건 처리시간 0.037초

Off-cycle에서 Euro 6a, 6b 및 6d 규제 만족 디젤 자동차의 NOx 배출 특성 (NOx Emission Characteristics of Diesel Passenger Cars Met Euro 6a, 6b and 6d Regulations on Off-cycles)

  • 김정환;김성우;김기호
    • 한국분무공학회지
    • /
    • 제23권3호
    • /
    • pp.136-148
    • /
    • 2018
  • Major countries have tighten their NOx regulation of diesel passenger cars. In the case of the EU, the regulation has been toughen up to 6.25 times since 2000. Despite the regulation the NOx concentration of the ambient has not been reduced proportionally. As these issues, to reduce NOx emission practically, Korea and the EU introduced the real-world driving emission (RDE) regulation and the test method that will be applied after 2017. In this paper, for the regulation to make a soft landing in Korea, 6 diesel passenger cars which met Euro 6a~6d regulation and were equipped with LNT/SCR were tested at a chassis dynamometer with environmental chamber applying the off-cycles (FTP, US06, SC03, HWFET and CADC) and several ambient conditions (-7 and $14^{\circ}C$) as well as certification modes (NEDC, WLTC@ $23^{\circ}C$). The result of the test showed that the ambient temp. and the engine load as a test mode impacted the NOx emission of the cars while the vehicles with SCR emitted NOx lower than with LNT. Additionally, to propose an effective RDE test method, the above result was compared with the results of the other papers which tested RDE using the same cars.

활동기준 경영기법에 의한 전사적 자원관리에 관한 연구 (Study on Enterprise Resources Planning by Activity Based Management Method)

  • 이장형
    • 경영과정보연구
    • /
    • 제2권
    • /
    • pp.209-235
    • /
    • 1998
  • Traditional cost system is distorted due to the using unit-based measure. It is being criticized that it do a poor job of attributing the expenses of support resources to the production and sales of individual product. Activity Based Cost System expend the range of second-stage cost assignment drivers beyond the traditional measures of labor and machine times, units produced, and material quantities to allow for drivers that measure the amount of batch-level, product-sustaining, and facility-sustaining activities performed. It is a resources consumption model of organization, not just a more complex cost accounting of cost allocation system. This paper proposes a enterprise resource planning by activity based management. To effective performance system for company that want to be setting competitive levels, the information systems must support a fast moving, rapidly changing. Activity based management is a process of accumulating and tracing cost and performance da to a firm's activities and providing feedback of actual results against the planned cost to initiate corrective action where required. Therefore this system provides a highly powerful decision-making tool. To construct this system, we need Enterprise Resource Planning System. Since ERP is designed around the idea that rapid change and a degree of unhandled change is normal, it allows driving the customer's rapidly needs much deeper through the business cycle.

  • PDF

A Numerical Model for the Freeze-Thaw Damages in Concrete Structures

  • Cho Tae-Jun
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.857-868
    • /
    • 2005
  • This paper deals with the accumulated damage in concrete structures due to the cyclic freeze-thaw as an environmental load. The cyclic ice body nucleation and growth processes in porous systems are affected by the thermo-physical and mass transport properties, and gradients of temperature and chemical potentials. Furthermore, the diffusivity of deicing chemicals shows significantly higher value under cyclic freeze-thaw conditions. Consequently, the disintegration of concrete structures is aggravated at marine environments, higher altitudes, and northern areas. However, the properties of cyclic freeze-thaw with crack growth and diffusion of chloride ion effects are hard to be identified in tests, and there has been no analytic model for the combined degradations. The main objective is to determine the driving force and evaluate the reduced strength and stiffness by freeze-thaw. For the development of computational model of those coupled deterioration, micro-pore structure characterization, pore pressure based on the thermodynamic equilibrium, time and temperature dependent super-cooling with or without deicing salts, nonlinear-fracture constitutive relation for the evaluation of internal damage, and the effect of entrained air pores (EA) has been modeled numerically. As a result, the amount of ice volume with temperature dependent surface tensions, freezing pressure and resulting deformations, and cycle and temperature dependent pore volume has been calculated and compared with available test results. The developed computational program can be combined with DuCOM, which can calculate the early aged strength, heat of hydration, micro-pore volume, shrinkage, transportation of free water in concrete. Therefore, the developed model can be applied to evaluate those various practical degradation cases as well.

세라믹 메탈할라이드 램프의 아크튜브 열화현상 분석 (Analysis of Degradation Phenomena in Arc-Tube of Ceramic Metal Halide Lamp)

  • 김우영;이세일;양종경;장혁진;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제23권12호
    • /
    • pp.996-1001
    • /
    • 2010
  • Recently, the demand of ceramic metal halide lamp has been expanded. Therefore, the lamp with high efficiency and long lifetime are increasing and the evaluation of reliability is needed. In this paper, the degradation phenomena of ceramic metal halide lamp was studied. The lamp was tested for 3000 on/off cycles with each cycle having a duration of 20 minutes on and 20 minutes off based on the accelerated aging experiment based on "Reliability Standards RS C 0085". As result, the corrosion of arc tube and leak was appeared from reaction between inner wall of PCA and chemical elements, and distortion of electrode was resulted from difference of thermal expansion between arc tube of PCA and electrode. Also, the efficiency of lamp was decreased by the change of inner pressure, operation temperature, and driving voltage from wall blackening.

Integrated Model of Power Electronics, Electric Motor, and Gearbox for a Light EV

  • Hofman, Isabelle;Sergeant, Peter;Van den Bossche, Alex;Koroglu, Selim;Kesler, Selami
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1640-1653
    • /
    • 2015
  • This study presents a model of a drivetrain for an integrated design of a light electric vehicle (EV). For the drivetrain of each front wheel of the single-person, battery-powered EV tricycle consists of a battery, an inverter, and an outer rotor permanent magnet synchronous motor (PMSM), which is connected to an in-wheel gearbox. The efficiency of the inverter, motor, and gearbox is analyzed over the New European Driving Cycle. To calculate the losses and efficiency of the PMSM, the power electronics in the inverter and gearbox are used. The analytical models provide a fast, but less accurate result, useful for optimization purposes. To accurately predict the efficiency of the PMSM, a finite element model is used. The models are validated by test setups. Correspondingly, a good agreement between the measurements and the calculated results is achieved. A parameter study is performed to investigate the influence of the detailed component parameters (i.e., outer rotor radius, gear ratio, and number of pole pairs and stator slots) on the average efficiency of the drivetrain.

확산 및 히스테리시스 현상을 고려한 확장칼만필터를 이용한 새로운 납축전지의 충전상태 추정방법 (Novel Estimation Technique for the State-of-Charge of the Lead-Acid Battery by using EKF Considering Diffusion and Hysteresis Phenomenon)

  • 덩반환;트란녹탐;박용진;최우진
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.139-148
    • /
    • 2014
  • State-of-charge (SOC) is one of the significant indicators to estimate the driving range of the electric vehicle and to control the alternator of the conventional engine vehicles as well. Therefore its precise estimation is crucial not only for utilizing the energy effectively but also preventing critical situations happening to the power train and lengthening the lifetime of the battery. However, lead-acid battery is time-variant, highly nonlinear, and the hysteresis phenomenon causes large errors in estimation SOC of the battery especially under the frequent discharge/charge. This paper proposes a novel estimation technique for the SOC of the Lead-Acid battery by using a well-known Extended Kalman Filter (EKF) and an electrical equivalent circuit model of the Lead-Acid battery considering diffusion and hysteresis characteristics. The diffusion is considered by the reconstruction of the open circuit voltage decay depending on the rest time and the hysteresis effect is modeled by calculating the normalized integration of the charge throughput during the partial cycle. The validity of the proposed algorithm is verified through the experiments.

바이모달 트램의 추진장치 성능 모의 (A Simulation Study of the Performance of a Propulsion Equipment for Bimodal Tram)

  • 배창한;목재균;장세기;이강원
    • 한국철도학회논문집
    • /
    • 제12권1호
    • /
    • pp.122-128
    • /
    • 2009
  • 바이모달 수송시스템 연구단에서 개발중인 트램은 자동운전이 가능하고 일반도로와 전용구간을 주행할 수 있는 고무차륜방식의 저상굴절 바이모달 트램으로서, 압축천연가스 엔진과 리튬폴리머 배터리를 사용하는 직렬형 하이 브리드 추진계로 구동된다. 본 논문에서는 바이모달 트램의 직렬형 하이브리드 추진장치의 요구사양을 제시하고 하이브리드 추진제어방식에 관해 설명한다. 하이브리드 차량 시뮬레이션 툴인 ADVISOR를 사용하여 기준 주행사이클과 일본의 10-15 mode에 대한 바이모달 트램의 주행을 모의하고, CNG 하이브리드 추진계에 대한 성능을 분석한다.

Development of high capacity stirling cryocooler

  • Ko, Junseok;Yeom, Hankil;Kim, Hyobong;Hong, Yong-Ju;In, Sehwan;Park, Seong-Je
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.51-56
    • /
    • 2015
  • Cryogenic cooling system for HTS electric power devices requires a reliable and efficient high-capacity cryocooler. A Striling cryocooler with a linear compressor can be a good candidate. It has advantages of low vibration and long maintenance cycle compared with a kinematic-driven Stirling cryocooler. In this study, we developed dual-opposed linear compressor of 12 kW electric input power with two 6 kW linear motors. Electrical performance of fabricated linear compressor is verified by experimental measurement of thrust constant. The developed Stirling cryocooler has gamma-type configuration. Piston and displacer are supported with flexure spring. A slit-type heat exchanger is adopted for cold and warm-end, and the generated heat is rejected by cooling water. In cooling performance test, waveforms of voltage, current, displacement and pressure are obtained and their amplitude and phase difference are analysed. Moreover, temperatures of cooling water, housing and linear motor are recorded and electric power parameters of driving circuit are also obtained. The developed Stirling cryocooler reaches to 47.8 K within 23.4 min. with no-load. From heat load tests, it shows cooling capacity of 440 W at 78.1 K with 6.45 kW of electric input power and 19.4 of % Carnot COP.

LED 구동용 단일단 PFC CCM 플라이백 컨버터의 히스테리시스 최적 제어 (Optimal Hysteresis Control for CCM Driving of a Single-Stage PFC Flyback Converter for LED Lightings)

  • 김춘택
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.586-592
    • /
    • 2016
  • The current control of Continuous Conduction Mode(CCM) can be implemented by several methods: peak current control; average current control; and hysteresis control. Among these methods, the hysteresis current control is popularly applied in various converter applications because of its simplicity of implementation, fast current control response and inherent peak current limiting capability. However, a current controller with conventional hysteresis band which multiplies the current reference has the disadvantage that the modulation frequency varies in one cycle of the input voltage and, as a result, generates high switching frequency in the low input voltage section. Also it is complicated to design the input filter due to varying switching frequency. This paper proposed an optimum hysteresis-band current control method where the band is generated by using both multiplication method and sum method to maintain the modulation frequency to be nearly constant. This approach can solve the high switching frequency in the low input voltage section, and achieve easy design of input filter. The performance of the proposed converter is verified with the simulation and the experimental works.

The Kennicutt-Schmidt relation of the ram pressure stripped gas

  • Lee, Bumhyun;Chung, Aeree
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.75.1-75.1
    • /
    • 2017
  • Ram pressure due to the intracluster medium (ICM) is known to play a crucial role in removing the cool gas content of a galaxy on a short timescale, potentially driving a star forming galaxy to evolve into a red passive population. Although many HI imaging studies find clear evidence of diffuse atomic gas stripping from cluster galaxies, it is still debatable whether the ram pressure can also strip dense molecular gas. NGC 4522, a Virgo spiral, undergoing strong ram pressure stripping, is one of the few cases where extraplanar CO emission together with stripped HI gas and $H{\alpha}$ knots has been identified, providing an ideal laboratory to study the molecular gas stripping event and the extraplanar star formation activity. The aim of this work is to investigate the origin of extraplanar molecular clouds near NGC 4522 (e.g. stripped or forming in situ), and to probe a relation between the molecular gas surface density and the star formation rate (i.e. the Kennicutt-Schmidt law) at sub-kpc scale, especially in the extraplanar space, using ALMA Cycle 3 CO data and $H{\alpha}$ data of NGC 4522. We present the results from our ALMA observations, and discuss possible scenarios for the origin of extraplanar molecular clouds and to characterize the star formation activity associated with stripped gas outside the galactic disk.

  • PDF