• 제목/요약/키워드: Drilled pier

검색결과 8건 처리시간 0.026초

실증시험을 통한 강관주기초의 거동특성 (Behavior of Single Pole Foundation using Experimental Study)

  • 김대홍;오기대
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.598-604
    • /
    • 2010
  • The drilled pier foundation is widely used to support transmission line structures due to its simplicity of construction. When this foundation type is used in conjunction with a single shaft or H-frame structure, it is subjected to a high overturning moment, combined with modest vertical and shear loads. Since the length and diameter of drilled piers are often governed by a maximum permissible deflection, many drilled piers being installed today are very conservatively designed. In this study, Nine prototype field-tests (1/8 scale) have been conducted in order to determine the vertical and lateral resistance of drilled pier foundation for single pole structures. These test results reveal the test piers behaved essentially as rigid bodies in soil (6D) and the center of rotation of the pier were typically 0.6~0.4 of the pier depth below ground surface. Test results also show the relationship between the applied load and the deflection at the top of the pier is highly nonlinear.

  • PDF

강관주 철탑기초의 수평거동에 관한 실험적 연구 (Experimental Study on the Laterally Loaded Behavior of Single Pole Foundation)

  • 김대홍;김경열
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1087-1094
    • /
    • 2008
  • The drilled pier foundation is widely used to support transmission line structures due to its simplicity of construction. When this foundation type is used in conjunction with a single shaft or H-frame structure, it is subjected to a high overturning moment, combined with modest vertical and shear loads. Since the length and diameter of drilled piers are often governed by a maximum permissible deflection, many drilled piers being installed today are very conservatively designed. In this study, Five prototype field-tests (1/8 scale) have been conducted in order to determine the lateral resistance of drilled pier foundation for single pole structures. These test results reveal the test piers behaved essentially as rigid bodies in soil (6D) and the center of rotation of the pier were typically 0.6~0.4 of the pier depth below ground surface. Test results also show the relationship between the applied load and the deflection at the top of the pier is highly nonlinear.

  • PDF

바이모달 트램 운행을 위한 도심지 고가구조물 기초형식 개발 (Development of Foundation of Urban Overpass for Bimodal Tram System)

  • 강태식;배을호;박영곤;윤희택
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.194-198
    • /
    • 2008
  • The necessities of development of foundation having minimized occupying area and construction time are required for overpass in the downtown area by which bimodal tram will pass a crossway. We are studying a single column drilled pier foundation which is continuous from pier to pile foundation. Due to the increased resisting moment by reinforced steel which is ranged from the upper part of pile to lower part of column above ground, it can be possible to make a smaller pile-section and lessen the bar reinforcing. And for the excavation work is possible with smaller equipment, this foundation has a improved constructability and economical efficiency. This foundation needs smaller amount of concrete and has a small self-weight. It has an effect on improving resistance against earthquake due to improved ductility in addition to improved rigidity by interaction between concrete and steel.

  • PDF

다주식 기초 해상교량에서 대구경 현장타설말뚝과 파일캡의 강결합에 대한 분석 (Analysis on the Rigid Connections between the Large Diameter Drilled Shaft and the Pile Cap for the Sea-Crossing Bridges with Multiple Pile Foundations)

  • 조성민;박상일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.343-358
    • /
    • 2008
  • Piles of a bridge pier are connected with a column through a pile cap(footing). Behavior of the pile foundation can be different according to the connection method between piles and the pile cap. This difference causes a change of the design method. Connection methods between pile heads and the pile cap are divided into two groups ; rigid connections and hinge connections. KHBDC(Korea Highway Bridge Design Code) has specified to use rigid connection method for the highway bridge. In the rigid connection method, maximum bending moment of a pile occurs at the pile head and this helps the pile to prevent the excessive displacement. Rigid methods are also good to improve the seismic performance. However some specifications prescribe that conservative results through investigations for both the fixed-head condition and the free-head condition should be reflected in the design. This statement may induce an over-estimated design for the bridge which have very good quality structures with casing covered drilled shafts and the PC-house contained pile cap. Because the assumption of free-head conditions (hinge connections) are unreal for the elevated pile cap system with multiple piles of the long span sea-crossing bridges. On the other hand, elastic displacement method to evaluate the pile reactions under the pile cap is not suitable for this type of bridges due to impractical assumptions. So, full modeling techniques which analyze the superstructure and the substructure simultaneously should be performed. Loads and stress state of the very large diameter drilled shaft and the pile cap for Incheon Bridge which will the longest bridge in Korea were investigated through the full modeling for rigid connection conditions.

  • PDF

암반 정착 대구경 피어기초의 거동특성에 관한 연구 (The Behavior of Large Diameter Rock Socketed Piles)

  • 김태현;김찬국;황의석;이봉열;김학문
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1245-1250
    • /
    • 2006
  • The rapid growth of the economy recently gas led to increasing social needs for large scaled structures, such as high-rise buildings and long span bridges. In building these large-scaled structures the trend has been to construct foundations beating on or in rock masses in order to ensure stability and serviceability of the structure under several significant loads. However. when designing the drilled shaft foundation socketed in rock masses in Korea, the bearing capacity for the pier used to be determined by using the empirical expression, which depends on the compressive strength of the rock, or presumable bearing capacity recommended on foreign references or manuals. In this study, numerical analyses are used to trace rock-socketed pile behavior and are made alike with pile load test result in field. The result of this numerical analyses study have shown that following factors have a significant influence on the load capacity and settlement of the pier. Significant influence first factor of the geometry of the socket as defined by the length to diameter ratio. Second factor of the modulus of the rock both around the socket and below the base. third factor of the condition of the end of the pier with respect to the removal of drill cuttings and other loose material from the bottom of the socket.

  • PDF

대구경 말뚝정재하시험 및 하중전이 측정사례 (Static pile load test and load trasfer measurement for large diameter piles.)

  • 최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 말뚝기초 학술발표회
    • /
    • pp.107-141
    • /
    • 2000
  • Large diameter piles can be defined as piles with diameter of at least 0.76 m (2.5 ft). In bridge foundation, large diameter piles have been used as pier foundations and their use has been increased greatly. In this study, static pile load tests for large diameter piles peformed in Kwangan Grande Bridge construction site were introduced. Also, various sensor installation methods for several types of piles (that is, open-ended steel pipe pile, drilled shafts and socketed pipe piles), pipe axial load measuring method, load transfer analysis method and pile load test results (pile-head load - settlement curve, and pile axial load distribution curve along the pile depth) were introduced.

  • PDF

현장타설말뚝을 적용한 다주식 기초에서 말뚝과 캡의 강결합에 대한 분석 (Analysis on the Rigid Connections of the Drilled Shaft with the Cap for Multiple Pile Foundations)

  • 조성민
    • 한국지반공학회논문집
    • /
    • 제24권7호
    • /
    • pp.61-73
    • /
    • 2008
  • 다수의 말뚝을 캡(확대기초)으로 연결하여 하중을 지지하는 다주식 기초에 대하여 캡의 연결부를 강결합 조건과 힌지결합 조건으로 구분하여 말뚝 반력 해석의 합리성을 분석하였으며, 널리 사용 중인 탄성변위법과 라멘식 프레임 해석에 기반한 비선형 해석기법을 비교하여 검토하였다. 특히 실제 해상 장대교량의 조건을 대상으로 상부구조와 기초를 연계한 전체 구조계 해석 결과를 분석하여 말뚝머리 구속 조건에 대한 기초 부재 단면력 산정의 적정성을 파악하였다. 이를 위해 캡과 연결된 각 말뚝에서 발생하는 휨모멘트, 전단력, 압축력 등 반력을 산정하고 PM상관도 분석과 지지력 산정을 통해 말뚝 부재의 안정성을 검토하였다. 일반적인 규모의 교량, 또는 강성이 크지 않은 말뚝을 적용한 기초에서는 말뚝-캡 결합 조건에 따른 말뚝 단면 설계의 차이가 현저하지 않으나, 말뚝이 지면 위로 일정 길이 이상 돌출되는 다주식 기초의 해상교량에서는 말뚝머리를 힌지로 고려할 경우 지중부에서 매우 큰 휨모멘트와 전단력이 유발되며, 말뚝머리의 수평변위량이 극단적으로 증가하였다. 해상 장대교량에 대해서는 비현실적 가정조건에 기반한 탄성변위법 보다는 말뚝머리를 캡에 강결합하고 말뚝이 탄성판에 지지된 보로 간주하는 라멘(rahmen) 모델링을 통해 상부구조와 연계한 전체 구조계 해석을 수행하는 것이 바람직하다.

단일 현장타설말뚝의 설계시 지반 모델링 방법 (Soil Modelling Method to Design Bent Foundation with Drilled Shaft Pier)

  • 전경수;한경봉;송필용
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.368-376
    • /
    • 2010
  • 암반의 심도가 얕은 국내지반에서는 푸팅을 사용하지 않는 벤트기초가 매우 경제적인 공법이다. 현장타설말뚝을 이용한 벤트기초공법은 탄성설계로 제한하여 설계를 수행하여 왔으나, 도로교 설계기준에서 제시하는 소성설계를 적용하는 경우 소성힌지 발생지점이 지중에 위치하여 유지관리가 불가하고 소성힌지부에 적용하는 심부구속 철근의 간격 및 보강범위에 대한 기준 제정이 필요하다. 또한 지반의 소성 거동을 모델링 하는 것은 구조 해석시 실무적으로 매우 어려움이 많아 정밀한 해석이 필요하지 않는 경우에 대한 근사 해석법 제시가 필요하다. 본 논문에서는 직경 1m의 현장타설말뚝을 사질토지반에 시공하여 지상 4m 높이에서 반복 재하시험을 수행하여 지반 및 말뚝의 거동을 파악하였으며, 기둥으로서의 거동을 함께 파악하였다. 소성힌지를 지상부에 유도하기 위하여 직경을 변화시키거나, 지중에 강관을 삽입하는 방법을 적용하였으며, 실험결과에 대하여 선형탄성 및 p-y 곡선등 다양한 예측방법과 교량에 대한 모의 설계를 통하여 지반 모델링 방법에 따른 해석결과를 비교하였으며, 실무적으로 적용할 수 있는 설계기준을 제시하였다.

  • PDF