• Title/Summary/Keyword: Drift ratio

Search Result 367, Processing Time 0.027 seconds

Quantitative Damage Index of RC Columns with Non-seismic Details (비내진상세를 가지는 철근콘크리트 기둥의 정량적 손상도 평가 기준)

  • Kim, Kyung-Min;Oh, Sang-Hoon;Choi, Kwang-Yong;Lee, Jung-Han;Park, Byung-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.11-20
    • /
    • 2013
  • In this paper, the quantitative damage index for reinforced concrete (RC) columns with non-seismic details were presented. They are necessary to carry out the postearthquake safety evaluation of RC buildings under 5 stories without seismic details. The static cyclic test of the RC frame sub-assemblage that was an one span and actual-sized was first conducted. The specimen collapsed by the shear failure after flexural yielding of a column, lots of cracks on the surfaces of columns and beam-column joints and the cover concrete splitting at the bottom of columns occurred. The damage levels of these kinds of columns with non-seismic details were classified to five based on the load-displacement relationship by the test result. The residual story drift ratios and crack widths were then adapted as the quantitative index to evaluate the damage limit states because those values were comparatively easy to measure right after earthquakes. The highest one among the residual story drift ratios under the similar maximum story drift ratio decided on the residual story drift ratio of each damage limit state. On the other hand, the lowest and average ones among the respective residual shear and flexural widths under the similar maximum story drift ratio decided on the residual shear and flexural widths of each damage limit state, respectively. These values for each damage limit state resulted in being smaller than those by the international damage evaluation guidelines that are for seismically designed members under the same deformations.

Seismic collapse risk of RC frames with irregular distributed masonry infills

  • Li, Yan-Wen;Yam, Michael C.H.;Cao, Ke
    • Structural Engineering and Mechanics
    • /
    • v.76 no.3
    • /
    • pp.421-433
    • /
    • 2020
  • Masonry infills are normally considered as non-structural elements in design practice, therefore, the interaction between the bounding frame and the strength contribution of masonry infills is commonly ignored in the seismic analysis work of the RC frames. However, a number of typical RC frames with irregular distributed masonry infills have suffered from undesirable weak-story failure in major earthquakes, which indicates that ignoring the influence of masonry infills may cause great seismic collapse risk of RC frames. This paper presented the investigation on the risk of seismic collapse of RC frames with irregularly distributed masonry infills through a large number of nonlinear time history analyses (NTHAs). Based on the results of NTHAs, seismic fragility curves were developed for RC frames with various distribution patterns of masonry infills. It was found that the existence of masonry infills generally reduces the collapse risk of the RC frames under both frequent happened and very strong earthquakes, however, the severe irregular distribution of masonry infills, such as open ground story scenario, results in great risk of forming a weak story failure. The strong-column weak-beam (SCWB) ratio has been widely adopted in major seismic design codes to control the potential of weak story failures, where a SCWB ratio value about 1.2 is generally accepted as the lower limit. In this study, the effect of SCWB ratio on inter-story drift distribution was also parametrically investigated. It showed that improving the SCWB ratio of the RC frames with irregularly distributed masonry infills can reduce inter-story drift concentration index under earthquakes, therefore, prevent weak story failures. To achieve the same drift concentration index limit of the bare RC frame with SCWB ratio of about 1.2, which is specified in ACI318-14, the SCWB ratio of masonry-infilled RC frames should be no less than 1.5. For the open ground story scenario, this value can be as high as 1.8.

Studies on Evaluation for Long-term Loading of Composite Wood-joint and Characteristics of Joint Strength (I) - The strength properties of mechanical joints of Pinus densiflora with drift pin and bolt - (목재 접합부의 강도특성 및 장기 내력 평가 (I) - 소나무재의 Bo1t 및 Drift pin 접합부 능력(耐力) 성능 평가 -)

  • Hong, Soon-Il;Hwang, Won-Jung;Kim, Eun-Sam;Jin, Kwang-Sung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.1-8
    • /
    • 2001
  • This study was carried out to investigate the strength and stiffness of drift pinned and bolted joints with steel-plates by the tension-type lateral strength tests. Specimens were solid wood of Pinus densiflora. Bolt and drift pin were jointed with inserted steel plates. Tests were conducted with combinations of two loading directions (parallel to the grain : 0 degree, perpendicular to the grain : 90 degree) and three diameters of fasteners (d = 6 mm, 10 mm, 12 mm). The results obtained were as follow: 1. In the test of the parallel to the grain, maximum loads were increased with increasing of the diameter of bolt and drift pin in the same end distance. In the test of perpendicular to the grain with diameter 10 mm and 12 mm, specimens mostly were failed with horizontal splits in woods reaching the yield load of drift pinned and bolted joints. 2. The ratio of maximum load to the yield load determined by the so-called "5% offset method", was great in bolted joints in the parallel to the grain This trend become more remarkable as the slenderness ratio was increased. 3. The calculated yield strength was agreed well with the experimental results of drift pinned joint(0 degree).

  • PDF

Distribution of Catches and Condition of Fishing Ground for Tuna Purse Seine in the Western Pacific Ocean (서부태평양에서 다랑어 선망어업의 어획분포와 어장환경)

  • 김형석
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.227-236
    • /
    • 1999
  • Temperal and spacial analysis for catches have been drawing up a catch distribution chart and analysing catches and CPUE(Catch Per Unit Effort) using catch data with purpose of obtaining basic data to establish a selective method of effective fishing the tuna purse seine fishing ground.The temperature profile section and catch was surveyed to analyse the effect of catch in relation to the fishing ground environment.The results are as follows ;1. As for the catch variation between 1983 and 1984, the catch mainly took place on150^{\circ}E$, and after that it moved eastward enlarging the range of catch. In the monthly catch variation between January and February, the catches mainly happened on 135$^{\circ}$~ 150$^{\circ}$E, and then moved to the gradually westward. However, from July it moved to the South and from October Southeast.2. As to the eatch ratio for the school associated with the drifted object, the pelagic migrating school and the school associated with the biological objects, the catch ratio for the school associated with the drift objects was the highest. The catch ratio for the school associated with the drifted object was high in June, July and November whiles between January and March for the pelagic migrating school.3. SST(Sea Surface Temperature) was around 28~29^C$ on the observing line of 137^{\circ}E$ and the catches took place in the north equatorial counter-current situated on around $5^{\circ}~6^{\circ}N$. SST in the northern summer was 1^C$higher than winter and it was about 29~30^C$. The catch happened with the center of north equatorial counter-current. The reason why the catch mainly took place on the north equatorial counter-current is that main catch of tuna purse seine was the school associated with drift objects. It is thought that the fishing grounds are made in waters that have many drift objects like drift logs from the coast.

  • PDF

Hysteresis performance of earthquake-damaged resilient RAC shear walls retrofitted with CFRP strips and steel plates

  • Jianwei Zhang;Siyuan Wang;Man Zhang;Yuping Sun;Hongwei Wang
    • Steel and Composite Structures
    • /
    • v.52 no.3
    • /
    • pp.357-376
    • /
    • 2024
  • In this paper, weakly bonded ultra-high-strength steel bars (UHSS) were used as longitudinal reinforcement in recycled aggregate concrete shear walls to achieve resilient performance. The study evaluated the repairability and hysteresis performance of shear walls before and after retrofitting. Quasi-static tests were performed on recycled aggregate concrete (RAC) and steel fiber reinforced recycled aggregate concrete (FRAC) shear walls to investigate the reparability of resilient shear walls when loaded to 1% drift ratio. Results showed that shear walls exhibited drift-hardening properties. The maximum residual drift ratio and residual crack width at 1% drift ratio were 0.107% and 0.01mm, respectively, which were within the repairable limits. Subsequently, shear walls were retrofitted with bonded X-shaped CFRP strips and steel plates wrapped at the bottom and retested. Except for a slight reduction in initial stiffness, earthquake-damaged resilient shear walls retrofitted with a composite method still had satisfactory hysteresis performance. A revised damage assessment index D, has been proposed to assess of damage degree. Moreover, finite-element analysis for the shear wall before and after retrofit retrofitting was established in OpenSees and verified with experimental results. The finite element results and test results were in good agreement. Finally, parametric analysis was performed.

Study on the performance indices of low-strength brick walls reinforced with cement mortar layer and steel-meshed cement mortar layer

  • Lele Wu;Caoming Tang;Rui Luo;Shimin Huang;Shaoge Cheng;Tao Yang
    • Earthquakes and Structures
    • /
    • v.24 no.6
    • /
    • pp.439-453
    • /
    • 2023
  • Older brick masonry structures generally suffer from low strength defects. Using a cement mortar layer (CML) or steel-meshed cement mortar layer (S-CML) to reinforce existing low-strength brick masonry structures (LBMs) is still an effective means of increasing seismic performance. However, performance indices such as lateral displacement ratios and skeleton curves for LBMs reinforced with CML or S-CML need to be clarified in performance-based seismic design and evaluation. Therefore, research into the failure mechanisms and seismic performance of LBMs reinforced with CML or S-CML is imperative. In this study, thirty low-strength brick walls (LBWs) with different cross-sectional areas, bonding mortar types, vertical loads, and CML/S-CML thicknesses were constructed. The failure modes, load-carrying capacities, energy dissipation capacity and lateral drift ratio limits in different limits states were acquired via quasi-static tests. The results show that 1) the primary failure modes of UBWs and RBWs are "diagonal shear failure" and "sliding failure through joints." 2) The acceptable drift ratios of Immediate Occupancy (IO), Life Safety (LS), and Collapse Prevention (CP) for UBWs can be 0.04%, 0.08%, and 0.3%, respectively. For 20-RBWs, the acceptable drift ratios of IO, LS, and CP for 20-RBWs can be 0.037%, 0.09%, and 0.41%, respectively. Moreover, the acceptable drift ratios of IO, LS, and CP for 40-RBWs can be 0.048%, 0.09%, and 0.53%, respectively. 3) Reinforcing low-strength brick walls with CML/S-CML can improve brick walls' bearing capacity, deformation, and energy dissipation capacity. Using CML/S-CML reinforcement to improve the seismic performance of old masonry houses is a feasible and practical choice.

Seismic performance of RC short columns with light transverse reinforcement

  • Tran, Cao Thanh Ngoc;Li, Bing
    • Structural Engineering and Mechanics
    • /
    • v.67 no.1
    • /
    • pp.93-104
    • /
    • 2018
  • The seismic behavior of reinforced concrete (RC) short columns with limited transverse reinforcement is investigated in this paper through an experimental program. The experimental program consists of four small-scale RC columns with an aspect ratio of 1.7, which are tested to the axial failure stage. The cracking patterns, hysteretic responses, strains in reinforcing bars, displacement decomposition and cumulative energy dissipation of the tested specimens are reported in detail in the paper. The effects of column axial load are investigated to determine how this variable might influence the performance of the short columns with limited transverse reinforcement. Brittle shear failure was observed in all tested specimens. Beneficial and detrimental effects on the shear strength and drift ratio at axial failure of the test specimens due to the column axial load are found in the experimental program, respectively.

Experimental Evaluation of the Seismic Performance and Engineering Damage State of Reinforced Concrete Columns (철근콘크리트 기둥의 내진성능 및 공학적 손상상태에 대한 실험적 평가)

  • Lee, Do Hyung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.119-127
    • /
    • 2023
  • In this paper, seismic performance evaluation was carried out for eight circular reinforced concrete columns designed seismically by KRTA[1]and KCI[8]. Primary design parameters for such columns included many longitudinal reinforcements, yield strength of reinforcements, the vertical spacing of spirals, aspect ratio, and axial force ratio. The test results showed that all the columns exhibited stable hysteretic and inelastic responses. Based on the test results, drift ratios corresponding to each damage state, such as initial yielding, initial cover spalling, initial core concrete crushing, buckling, and fracture of longitudinal reinforcement and final spalled region, were evaluated. Then, those ratios were compared with widely accepted damage limit states. The comparison revealed that the existing damage states were considerably conservative. This implies that additional research is required for the damage limit states of such columns designed seismically by current Korean design codes.

Comparison of monotonic and cyclic pushover analyses for the near-collapse point on a mid-rise reinforced concrete framed building

  • GUNES, Necmettin
    • Earthquakes and Structures
    • /
    • v.19 no.3
    • /
    • pp.189-196
    • /
    • 2020
  • The near-collapse performance limit is defined as the deformation at the 20% drop of maximum base shear in the decreasing region of the pushover curve for ductile framed buildings. Although monotonic pushover analysis is preferred due to the simple application procedure, this analysis gives rise to overestimated results by neglecting the cumulative damage effects. In the present study, the acceptabilities of monotonic and cyclic pushover analysis results for the near-collapse performance limit state are determined by comparing with Incremental Dynamic Analysis (IDA) results for a 5-story Reinforced Concrete framed building. IDA is performed to obtain the collapse point, and the near-collapse drift ratios for monotonic and cyclic pushover analysis methods are obtained separately. These two alternative drift ratios are compared with the collapse drift ratio. The correlations of the maximum tensile and compression strain at the base columns and beam plastic rotations with interstory drift ratios are acquired using the nonlinear time history analysis results by the simple linear regression analyses. It is seen that these parameters are highly correlated with the interstory drift ratios, and the results reveal that the near-collapse point acquired by monotonic pushover analysis causes unacceptably high tensile and compression strains at the base columns, as well as large plastic rotations at the beams. However, it is shown that the results of cyclic pushover analysis are acceptable for the near-collapse performance limit state.

Prediction of shear strength and drift capacity of corroded reinforced concrete structural shear walls

  • Yang, Zhihong;Li, Bing
    • Structural Engineering and Mechanics
    • /
    • v.83 no.2
    • /
    • pp.245-257
    • /
    • 2022
  • As the main lateral load resisting system in high-rise reinforced concrete structures, the mechanical performance of shear wall has a significant impact on the structure, especially for high-rise buildings. Steel corrosion has been recognized as an important factor affecting the mechanical performance and durability of the reinforced concrete structures. To investigate the effect on the seismic behaviour of corroded reinforced concrete shear wall induced by corrosion, analytical investigations and simulations were done to observe the effect of corrosion on the ultimate seismic capacity and drift capacity of shear walls. To ensure the accuracy of the simulation software, several validations were made using both non-corroded and corroded reinforced concrete shear walls based on some test results in previous literature. Thereafter, a parametric study, including 200 FE models, was done to study the influence of some critical parameters on corroded structural shear walls with boundary element. These parameters include corrosion levels, axial force ratio, aspect ratio, and concrete compressive strength. The results obtained would then be used to propose equations to predict the seismic resistance and drift capacity of shear walls with various corrosion levels.