• 제목/요약/키워드: Drift ratio

검색결과 366건 처리시간 0.025초

Evaluating seismic demands for segmental columns with low energy dissipation capacity

  • Nikbakht, Ehsan;Rashid, Khalim;Mohseni, Iman;Hejazi, Farzad
    • Earthquakes and Structures
    • /
    • 제8권6호
    • /
    • pp.1277-1297
    • /
    • 2015
  • Post-tensioned precast segmental bridge columns have shown high level of strength and ductility, and low residual displacement, which makes them suffer minor damage after earthquake loading; however, there is still lack of confidence on their lateral response against severe seismic loading due in part to their low energy dissipation capacity. This study investigates the influence of major design factors such as post-tensioning force level, strands position, columns aspect ratio, steel jacket and mild steel ratio on seismic performance of self-centring segmental bridge columns in terms of lateral strength, residual displacement and lateral peak displacement. Seismic analyses show that increasing the continuous mild steel ratio improves the lateral peak displacement of the self-centring columns at different levels of post-tensioning (PT) forces. Such an increase in steel ratio reduces the residual drift in segmental columns with higher aspect ratio more considerably. Suggestions are proposed for the design of self-centring segmental columns with various aspect ratios at different target drifts.

레버형 질량동조감쇠기에 의한 진동제어 (Vibration Control by Lever-type Tuned Mass Damper)

  • 심철권;은희창;김진봉
    • 대한건축학회논문집:구조계
    • /
    • 제34권12호
    • /
    • pp.27-34
    • /
    • 2018
  • This paper considers the seismic performance of lever-type tuned mass damper(TMD). The lever-type TMD is designed utilizing the seismic-performance of TMD and the control force required for constraining story drift. The TMD is basically designed by tuning the frequency of primary structure. Thus, the TMD plays an important role to reduce the dynamic responses. The lever-type TMD has a merit to control more displacement responses than the existing TMD due to the control forces. It is shown that the optimum design of lever-type TMD is affected by the ratio of the TMD mass with respect to the mass of the primary structure, the damping ration of the primary structure, and the length ratio of the lever. A numerical example exhibits the effectiveness of the dynamic control by the lever-type TMD and its validity is illustrated in a three-story building structure subjected to earthquake.

Aspect ratios of code-designed steel plate shear walls for improved seismic performance

  • Verma, Abhishek;Sahoo, Dipti R.
    • Steel and Composite Structures
    • /
    • 제42권1호
    • /
    • pp.107-121
    • /
    • 2022
  • Past studies have shown that the aspect ratio (width-to-height) of a steel plate shear wall (SPSW) can significantly affect its seismic response. SPSWs with lower aspect ratio (narrow SPSW) may experience low lateral stiffness and flexure dominated drift response. As the height of the frame increases, the narrow SPSWs prove to be uneconomical and demonstrate inferior seismic response than their wider counterparts. Moreover, the thicker web plates required for narrow SPSWs exerts high inward pull on the VBEs. The present study suggests the limiting values of the aspect ratio for an SPSW system by evaluating the seismic collapse performance of 3-, 6- and 9-story SPSW systems using FEMA P695 methodology. For this purpose, nonlinear models are developed. These models are validated with the past quasi-static experimental results. Non-linear static analyses and Incremental dynamic analyses are then carried. The results are then utilized to conservatively suggest the limiting values of aspect ratios for SPSW system. In addition to the conventional-SPSW (Conv-SPSW), the collapse performance of staggered-SPSW (S-SPSW) is also explored. Its performance is compared with the Conv-SPSW and the use of S-SPSW is suggested in the cases where SPSW with lower than recommended aspect ratio is desired.

Effect of geometrical configuration on seismic behavior of GFRP-RC beam-column joints

  • Ghomia, Shervin K.;El-Salakawy, Ehab
    • Advances in concrete construction
    • /
    • 제9권3호
    • /
    • pp.313-326
    • /
    • 2020
  • Glass fiber-reinforced polymer (GFRP) bars have been introduced as an effective alternative for the conventional steel reinforcement in concrete structures to mitigate the costly consequences of steel corrosion. However, despite the superior performance of these composite materials in terms of corrosion, the effect of replacing steel reinforcement with GFRP on the seismic performance of concrete structures is not fully covered yet. To address some of the key parameters in the seismic behavior of GFRP-reinforced concrete (RC) structures, two full-scale beam-column joints reinforced with GFRP bars and stirrups were constructed and tested under two phases of loading, each simulating a severe ground motion. The objective was to investigate the effect of damage due to earthquakes on the service and ultimate behavior of GFRP-RC moment-resisting frames. The main parameters under investigation were geometrical configuration (interior or exterior beam-column joint) and joint shear stress. The performance of the specimens was measured in terms of lateral load-drift response, energy dissipation, mode of failure and stress distribution. Moreover, the effect of concrete damage due to earthquake loading on the performance of beam-column joints under service loading was investigated and a modified damage index was proposed to quantify the magnitude of damage in GFRP-RC beam-column joints under dynamic loading. Test results indicated that the geometrical configuration significantly affects the level of concrete damage and energy dissipation. Moreover, the level of residual damage in GFRP-RC beam-column joints after undergoing lateral displacements was related to reinforcement ratio of the main beams.

Evaluation of responses of semi-rigid frames at target displacements predicted by the nonlinear static analysis

  • Sharma, Vijay;Shrimali, Mahendra K.;Bharti, Shiv D.;Datt, Tushar K.
    • Steel and Composite Structures
    • /
    • 제36권4호
    • /
    • pp.399-415
    • /
    • 2020
  • Responses of semi-rigid frames having different degrees of semi-rigidity obtained by the nonlinear static analysis (NSA) are evaluated at specific target displacements by comparing them with those obtained by the nonlinear time-history analysis (NTHA) for scaled earthquakes. The peak ground accelerations (PGA) of the earthquakes are scaled such that the obtained peak top story displacements match with the target displacements. Three different types of earthquakes are considered, namely, far-field and near-field earthquakes with directivity and fling-step effects. In order to make the study a comprehensive one, three degrees of semi-rigidity (one fully rigid and the other two semi-rigid), and two frames having different heights are considered. An ensemble of five-time histories of ground motion is included in each type of earthquake. A large number of responses are considered in the study. They include the peak top-story displacement, maximum inter-story drift ratio, peak base shear, total number of plastic hinges, and square root of sum of the squares (SRSS) of the maximum plastic hinge rotations. Results of the study indicate that the nonlinear static analysis provides a fairly good estimate of the peak values of top-story displacements, inter-story drift ratio (for shorter frame), peak base shear and number of plastic hinges; however, the SRSS of maximum plastic hinge rotations in semi-rigid frames are considerably more in the nonlinear static analysis as compared to the nonlinear time history analysis.

전단스팬비가 다른 보수된 벽체의 성능평가 (Performance of Repaired Structural Walls with Different Shear Span Ratios)

  • 한상환;오창학;이리형
    • 콘크리트학회논문집
    • /
    • 제15권1호
    • /
    • pp.1-10
    • /
    • 2003
  • 철근 콘크리트 구조 벽체는 횡력에 대해 효과적으로 저항하고 변위를 제어할 수 있어 널리 이용되지만 지진 발생시 구조벽체가 붕괴에 이르지 않는다 하더라도 어느 정도의 손상은 예상해야 한다. 본 연구에서는 심하게 손상된 유효전단스팬비가 다른 철근 콘크리트 구조벽체의 단순 보수를 통해서 그 구조적 성능이 원래의 실험체에 비해 어느 정도 회복되는가를 평가하였다. 본 연구를 위하여 3개의 실험체 (전단스팬비 1, 2, 3)를 만들어 실험하였다. 실험은 원실험체를 점증 반복가력 재하로 심하게 손상시킨 후 실험체를 보수한 후 다시 재하하였다. 보수는 0.2mm이상의 균열부분의 콘크리트는 새 콘크리트로 교체하였고, 0.2mm이하의 균열은 단지 에폭시로 보수하였다. 또한 심하게 손상된 벽체 단부 부분의 철근은 같은 종류의 새 철근으로 교체되었다. 본 실험 연구를 통하여 단순보수를 통하여 벽체 강도는 회복 가능하나 변형능력은 회복이 되지 않는 것으로 나타났다.

고층 RC 건물골조시스템의 내진설계상 몇 가지 주요 문제점 (Some Critical Problems in Seismic Design of High-Rise RC Building frame Systems)

  • 이한선;정성욱;고동우
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.727-734
    • /
    • 2005
  • 최근 증가하고 있는 초고층 주거용 구조물 중 많은 수가 건축적인 이유로 인해 건물골조시스템을 주요 지진저항시스템으로 채택하고 있다. 그러나 KBC 2005를 적용하여 건물골조시스템을 설계할 때 기준에서 언급되지 않거나 모호한 표현으로 인해 설계자는 많은 어려움을 겪을 수 있다. 특히 정적$\cdot$동적 해석시 RC부재의 균열단면을 고려한 유효강성의 적용 방법, 변형 적합성을 고려한 골조의 설계법 등에서 어려움을 겪을 수 있다. 이에 대하여 전단벽과 골조(플랫 플레이트)로 이루어진 전형적인 건물골조시스템의 건물에 대해 KBC 2005를 적용하고 기준의 불명확한 부분에 대해서 여러 방법을 적용하여 해석한 결과 기준의 모호한 언급이나 설계자의 임의의 판단으로 인해 층간변위비, 전단벽 및 연결보의 요구강도 등에서 매우 큰 차이가 발생하였으며, 동일한 건물을 이중골조시스템으로 설계한 경우에 비해 건물골조시스템으로 설계한 경우 변형 적합성의 요구로 인해 전단벽의 높은 요구강도 뿐만 아니라 골조에서도 높은 연성이 요구되었다.

지진하중의 특성과 이력모델에 따른 저층 표준학교건물의 비탄성 지진거동 (Inelastic Seismic Behavior of Low-story Standard School Buildings according to Characteristics of Earthquake Loads and Hysteresis Models)

  • 김진상;윤태호
    • 한국산학기술학회논문지
    • /
    • 제13권9호
    • /
    • pp.4294-4301
    • /
    • 2012
  • 본 연구는 내진설계 되지 않은 학교시설물 중 다수를 차지하는 1980년도 표준설계 도면(건설부 공고 제130호, 1980년 10월 28일)에 의하여 건설된 국내에 현존하는 4층 모멘트 연성골조의 학교건물을 대상으로 이력모델의 특성과 지진파의 특성에 따라 표준학교건물의 비탄성지진거동을 분석하고자 한다. El-centro지진은 주파수 성분과 강진지속시간의 특성에 의하여 표준학교건물의 단변방향 층전단력, 층간변위비, 층변위 응답에 매우 큰 영향을 미치며 특히 수정다케다모델 선택시 응답의 차이가 매우 크게 나타남을 알 수 있다. 층전단력의 경우 최대 46%, 층간변위비의 경우 최대 70%, 층변위의 경우 최대 59%의 편차를 보인다. Santa Monica지진은 장변방향의 응답에서 이력모델별 편차가 더 크게 나타났으며, 층전단력은 최대 59%, 층간변위비는 최대 65%, 층변위는 최대 50%의 편차를 보였다. 이는 장변방향의 고유주기가 단변방향에 비하여 크기 때문에 1초이상의 주기성분이 많은 Santa Monica지진의 특성에 의한 것으로 판단된다. Taft지진은 이력모델에 따른 층간변위비와 층변위 응답의 편차가 가장 적은 것으로 나타났으며, 층간변위비는 최대 15%, 층변위는 최대 5%의 편차를 보여 변위응답에 있어서 이력모델에 가장 의존도가 적은 결과를 얻을 수 있을 것으로 판단 된다.

이력모델에 따른 표준학교건물의 비탄성거동 연구 (Inelastic Behavior of Standard School Building according to Hysteresis Models)

  • 제정현;김진상;윤태호
    • 한국산학기술학회논문지
    • /
    • 제10권4호
    • /
    • pp.838-845
    • /
    • 2009
  • 본 논문은 내진성능평가를 위해 사용되는 비탄성해석의 신뢰도와 정확도에 있어 결정적인 영향을 미치는 다양한 이력모델의 특성과 구조물의 내진거동에 미치는 영향을 분석하고자 한다. 연구대상은 표준학교건물로서 외국의 지진 가속도와 우리나라 규준에 맞는 인공지진 가속도 3가지를 건물의 장 단변방향 평면골조에 가한 후, 다양한 이력 모델을 적용하여 2차원 시간이력해석을 수행하고 비탄성응답을 구하고 층전단력, 층간변위비, 층변위를 비교하고 힌지의 발생 상태를 분석해 이력모델이 건물의 비탄성거동에 미치는 영향을 분석하였다. 그 결과, 단변방향에서는 층전 단력과 층간변위비 모두 최대값은 수정다케다모델에서, 최소값은 외국지진에 대해서는 클라프모델, 국내지진에 대해서는 강성저감 삼선형모델과 수정다케다모델에서 각각 발생하는 것으로 평가되었다. 하지만, 장변방향에서 외국지진은 강성저감 삼선형모델이, 국내지진은 수정다케다모델이 최대 층전단력을 보였고 층간변위비는 최대값은 수정다케다 모델에서, 최소값은 외국지진의 경우 클라프모델에서, 국내지진의 경우 다케다모델에서 나타났다. 장변방향에서 외국지진은 층전단력와 층간변위가 클라프모델에서 안전율을 낮게 보는 반면 국내지진에서는 수정다케다모델이 안전율을 낮게 평가하는 상이한 결과가 발생했다.

Cyclic testing of weak-axis column-tree connections with formation of plastic hinge at beam splice

  • Oh, Keunyeong;Chen, Liuyi;Hong, Sungbin;Yang, Yang;Lee, Kangmin
    • Earthquakes and Structures
    • /
    • 제8권5호
    • /
    • pp.1039-1054
    • /
    • 2015
  • The purpose of this study was to evaluate the seismic performance of weak-axis column-tree type connections used in steel moment frames. These connections are composed of a shop-welded and fieldbolted steel structure and can improve welding quality. On this basis, column-tree type connections are widely used in steel moment resisting frames in Korea and Japan. In this study, splices designed with a semirigid concept regarding the seismic performance of column-tree connections were experimentally evaluated. The structures can absorb energy in an inelastic state rather than the elastic state of the structures by the capacity design method. For this reason, the plastic hinge might be located at the splice connection at the weak-axis column-tree connection by reducing the splice plate thickness. The main variable was the distance from the edge of the column flange to the beam splice. CTY series specimens having column-tree connections with splice length of 600 mm and 900 mm were designed, respectively. For comparison with two specimens with the main variable, a base specimen with a weak-axis column-tree connection was fabricated and tested. The test results of three full-scale test specimens showed that the CTY series specimens successfully developed ductile behavior without brittle fracture until 5% story drift ratio. Although the base specimen reached a 5% story drift ratio, brittle fracture was detected at the backing bar near the beam-to-column connection. Comparing the energy dissipation capacity for each specimen, the CTY series specimens dissipated more energy than the base specimen.