• Title/Summary/Keyword: Drift force

Search Result 269, Processing Time 0.029 seconds

Seismic Behaviour of Exterior Joints in Post-Tensioned Flat Plate Systems (포스트 텐션 플랫 플레이트 외부 접합부의 내진 거동)

  • Han, Sang-Whan;Kee, Seong-Hoon;Kang, Tomas H.K.;Cho, Jong;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.595-602
    • /
    • 2006
  • An experimental study was conducted to investigate seismic behaviour of post-tensioned(PT) exterior slab-column connections used for the purpose to resist gravity loads only. For these, 2/3-scale, two PT post-tensioned exterior connections with two different tendon arrangement patterns and one conventional reinforced concrete(RC) exterior connection was tested under quasi-static, uni-directional reversed cyclic loading. During the lateral testing, gravity forces transferred to the column were kept constant to closely simulate a moment to shear ratio of a real building. One of the objectives of this study was to assess the necessity and/or the quantity of bottom bonded reinforcement needed to resist moment reversal which would occur under significant inelastic deformations of the adjacent lateral force resisting systems. The ACI 318 and 352 provisions for structural integrity were applied to provide the bottom reinforcement passing through the column for the specimens. Prior test results were also collected to conduct comparative studies for some design parameters such as the tendon arrangement pattern, the effect of post-tensioning forces and the use of bottom bonded reinforcement. Consequently, the impact of tendon arrangement on the seismic performance of the PT connection, that is lateral drift capacity and ductility, dissipated energy and failure mechanism, was considerable. Moreover, test results showed that the amount of bottom reinforcement specified by ACI 352. 1R-89 was sufficient for resisting positive moments arising from moment reversal under reversed cyclic loads. Shear strength of the tested specimens was more accurately predicted by the shear strength equation(ACI 318) considering the average compressive stress over the concrete($f_{pc}$) due to post-tensioning forces than that without considering $f_{pc}$.

A Modified Equivalent Frame Model for Plat Plate Slabs Under Lateral Loads (수평하중을 받는 플랫 플레이트 슬래브 해석을 위한 수정된 등가골조모델)

  • Han Sang-Whan;Park Young-Mi
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.3 s.87
    • /
    • pp.419-426
    • /
    • 2005
  • This study is to propose a modified equivalent frame model for flat plate slabs under lateral loads. ACI 318 (2002) allows equivalent frame methods to conduct two-way slab system analysis subjected to gravity loads as well as lateral loads. Since the equivalent frame method in the ACI 318 (2002) has been developed base on the behavior of two-way system for gravity loads, and nay not predict the behavior of flat plate slabs under lateral loads with good precision. This study develops a modified equivalent frame model which can give more precise answer for flat plate slabs under lateral loads. This model reflects the actual force transfer mechanism among the components of flat plate slab system, which are slabs, columns and torsional members, more accurately under lateral loads than existing equivalent frame models. The accuracy of this model is verified by comparing the analysis results using the proposed model with the results of finite element analysis. The analysis results of other existing models are included in the comparison. For this purpose, 2 story building having 3 spans in both directions is considered. Analytical results show that the modified equivalent frame model produces comparable drift and slab internal moments with those obtained from finite element analysis.

Pushover Analysis of a Five-Story Steel Framed Structure Considering Beam-to-Column Connection (보-기둥 접합부를 고려한 5층 철골골조구조물의 비탄성 정적해석)

  • Kang, Suk-Bong;Lee, Jae-Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.2
    • /
    • pp.129-137
    • /
    • 2010
  • In this study, a five-story steel frame was designed in accordance with KBC2005 to evaluate the effect of the beam-column connection on the structural behavior. The connections were designed as a fully rigid connection and as a semirigid connection. A fiber model was utilized to describe the moment-curvature relationship of the steel beam and column, and a three-parameter power model was adopted for the moment-rotation angle of the semirigid connection. To evaluate the effects of higher modes on structural behavior, the structure was subjected to a KBC2005-equivalent lateral load and lateral loads considering higher modes. The structure was idealized as a separate 2D frame and as a connected 2D frame. The pushover analysis of 2D frames for the lateral load yielded the top displacement-base shear force, design coefficients such as overstrength factor, ductility ratio, and response modification coefficient, demanded ductility ratio for the semirigid connection,and distribution of plastic hinges. The sample structure showed a greater response modification coefficient than KBC2005, the higher modes were found to have few effects on the coefficient, and the lateral load of KBC2005 was found to be conservative. The TSD connection was estimated to secure economy and safety in the sample structure.

The Strain of Transverse Steel and Concrete Shear Resistance Degradation after Yielding of Reinforced Concrete Circular Pier (철근콘크리트 원형 교각의 횡방향철근 변형률과 항복이후 콘크리트 전단저항 저감)

  • Ko, Seong Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.147-157
    • /
    • 2018
  • The basis of capacity design has been explicitly or implicitly regulated in most bridge design specifications. It is to guarantee ductile failure of entire bridge system by preventing brittle failure of pier members and any other structural members until the columns provides fully enough plastic rotation capacity. Brittle shear is regarded as a mode of failure that should be avoided in reinforced concrete bridge pier design. To provide ductility behavior of column, the one of important factors is that flexural hinge of column must be detailed to ensure adequate and dependable shear strength and deformation capacity. Eight small scale circular reinforced concrete columns were tested under cyclic lateral load with 4.5 aspect ratio. The test variables are longitudinal steel ratio, transverse steel ratio, and axial load ratio. Eight flexurally dominated columns were tested. In all specimens, initial flexural-shear cracks occurred at 1.5% drift ratio. The multiple flexural-shear crack width and length gradually increased until the final stage. The angles of the major inclined cracks measured from the vertical column axis ranged between 42 and 48 degrees. In particular, this study focused on assessing transverse reinforcement contribution to the column shear strength. Transverse reinforcement contribution measured during test. Each three components of transverse reinforcement contribution, axial force contribution and concrete contribution were investigated and compared. It was assessed that the concrete stresses of all specimen were larger than stress limit of Korea Bridge Design Specifications.

STUDIES ON THE SHAPE OF FISH REEFS AND THE THRONGING OF FISH SCHOOLS (어초의 형태와 어군의 위집에 관한 연구)

  • SHON Tae Joon;BAE Jeong Sig;SOH Doo Ok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.10 no.3
    • /
    • pp.179-187
    • /
    • 1977
  • This study intended to investigate the shape of the artificial fish reefs settled in the waters of Seogwipo, and the thronging of fish schools into them. The results obtained are summarized as follows : 1. Two types of artifical fish reef, circularized vertical type which is composed of Cryptomeria branches and parachute type, were put off the coast of Seogwipo at $33^{\circ}14'05'$ N Lat., $126^{\circ}34'40'$ E Long. The setting place is located 0.4 sea-mile away from natural fish reefs, at 25 m in depth. And its sediment is consisted of f. S. and Sh. 2. Maximum velocity of wind drift current was 15.28 cm/sec at 15 m depth. The Current direction was $20.5\%$n in the WSW. 3. Maximum fluid resistance of the circularized vertical type to current and wind waves showed about 890 kg, and the weight of sand bags attached to the fish reef totaling 1,200 kg was enough to sustain fish reef. 4. As maximum fluid resistance of the parachute type to current and wind waves was 106.3 kg, the retaining force of sand bags was enough to sustain the fish reef, but vinyl canvas and expansion materials were so poor that the fish reef was lost by the sea current and wind waves. 5. Sixteen species of fish among 53 usually caught in this area were thronged into the artificial fish reef. The fish catches comprized Porgy (Pagrosomus major) $23\%$, black kook fish (Sebastes (Mebarus) intermis) $13\%$, sand borer (Sillago sihama) $11\%$, Sebastes (Pteropodus) hubbsi $7\%$, and file fish (Monacanthus cirrhifer) $6\%$. According to the submarine observations by fivers, it was confirmed that a lot of fish larvae thronged in the middle part of the fish reefs.

  • PDF

Analysis of Littoral Currents by the Coupled Hydrodynamic Model (복합해수유동 수치모형에 의한 조간대 연안류의 해석)

  • Lee, Jong-Sup;Kwon, Kyong-Hwan;Park, Il-Heum
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.2
    • /
    • pp.247-258
    • /
    • 2014
  • To evaluate the influence of the external force components on the littoral currents in the Gusipo beach, Jeonbuk, West Coast of Korea where a wide tidal sand flat developed, a coupled hydrodynamic model considered real time tidal currents and wave-induced currents was constructed in which the EFDC for tides and tidal currents, the SWAN for waves and the SHORECIRC for wave-induced currents were used as the hindcasting models. A series of field observations for tides, tidal currents and incident waves were carried out and especially to observe the littoral currents in the tidal sand flat, the GPS mounted and light weight drogues were used. Also wind data were collected from the adjacent weather station. To analyze the littoral current components, the numerical drogue tracking results considered real time winds, tides and waves were compared with the field drogue data. The drift speed of numerical drogues was reproduced as the range of 68.0~105.2% compared with the field data and the velocity error of main direction component showed a good result as -16.7~10.0%. As a result, in the mild slope tidal flat including wide surf zone, the tides and winds were the major affection component of the littoral currents, on the other hand, the wave-induced currents seemed the minor component when the incident wave heights were relatively small.

Experimental and Numerical Study of Berthing and Unberthing of LNG-Bunkering Vessels (실험 및 수치해석을 통한 LNG 벙커링 선박들의 이접안 안정성 평가 연구)

  • Jung, Sung-Jun;Oh, Seung-Hoon;Jung, Dong-Woo;Kim, Yun-Ho;Jung, Dong-Ho
    • Journal of Navigation and Port Research
    • /
    • v.44 no.6
    • /
    • pp.439-446
    • /
    • 2020
  • The IMO has adopted emission standards through Annex VI of the International Convention for the Prevention of Pollution from Ships (MARPOL) that strictly prohibit the use of bunker C oil for vessels. In this study, we have adopted the turret-moored Floating LNG-Bunkering Terminal (FLBT) which is designed to receive the LNG from LNGCs and transfer it to LNG-bunkering shuttles in side-by-side moored condition. Numerical analyses were carried out using the high-order boundary-element method for four vessels at various relative distances. Mean wave drift forces were compared in an operational sea state. A model test was performed in the ocean engineering basin at the Korea Research Institute of Ships & Ocean Engineering (KRISO) to verify the safety of the berthing/unberthing operation. In the model test, a jig was designed to simulate tug boats pushing or pulling the bunkering vessels, so that the friction force of the g operation was not affected. Safety depended on the environmental direction, with more stable operation possible if the heading-control function of FLBT is applied to avoid beam-sea conditions.

A Study on the Required Horsepower of Tugboats at Jeju Port for Car Ferries - Focusing on Car Ferry H - (카페리여객선 제주항 입출항 시 예선 사용 기준에 관한 연구 - 카페리여객선 H호를 중심으로 -)

  • Byung-Sun Kang;Chang-Hyun Jung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.2
    • /
    • pp.209-216
    • /
    • 2024
  • Four accidents occurred between 2020 and 2022 after car ferries built according to a coastal passenger ship modernization plan collided with other ships or came into contact with the dock when entering Jeju Port. Accidents primarily occurred owing to careless ship handling and drift by wind during ship handled by herself using bow and stern thrusters without tugboats. Accordingly, in this study, we analyzed the collision accident focusing on car ferry H and the critical wind speed at which the ship cannot be controlled using its own power, tugboat operation plan in increasing wind speed were proposed based on the power required for the ship to berth parallel to the pier without a tugboat considering the external force and moment generated while the ship is berthing. A analysis of the critical wind speed of car ferry H by relative wind direction when using tugboats or not according to the loading status and the berthing speed, showed that one tugboat should be used at the stern when the lateral wind speed is over 10 m/s and two tugboats should be used when the lateral wind speed is over 14m/s berthing at Jeju port.

THE SPACE OF CONGENITALLY MISSING OF PRIMARY CANINE WITH ODONTOMA (치아종을 동반한 선천적 결손된 유견치의 공간)

  • Lee, Jung-Eun;Lee, Jae-Ho;Choi, Hyung-Jun;Kim, Seong-Oh;Song, Je-Seon;Son, Heung-Kyu;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.2
    • /
    • pp.233-239
    • /
    • 2010
  • Space loss of dental arch can appear when the proper position of teeth within the dental arch changes by a certain cause, because the balance of force makes changes about tooth position as well as alignment. The causes of space loss include proximal caries, early extraction, congenital missing of a tooth and hypodontia, etc. Among those causes of space loss, congenital missing of a tooth is more rarely observed in the primary dentition than in the permanent dentition. Congenital missing in the primary dentition is associated with that in the permanent dentition. Furthermore, it can cause space problem, such as mesial tilting or drift of adjacent teeth, space loss for permanent successors and dental arch constriction, etc. Primary lateral incisors is the most commonly involved, in the maxilla rather than in the mandible, but primary canine is rarely reported. In this patient, who visited the department of pediatric dentistry at Yonsei university dental hospital, it was observed that the maxillary right primary canine was congenitally missing and an odontoma was found insteadly. However, neither the space loss for the congenitally missing primary canine nor midline deviation is remarkable during the 2-year-10-month observation period. In addition, any clinical or radiographical symptom did not occur in spite of odontoma. Therefore, surgical enucleation of odontoma is planned according to the eruption of permanent lateral incisor or canine, unless eruption failure of permanent lateral incisor or canine nor cystic change around the odontoma is occurred. Through further evaluation, space maintainer or orthodontic treatment may be necessary.