• Title/Summary/Keyword: Drainage materials

Search Result 312, Processing Time 0.035 seconds

Analysis of Groundwater Level Reduction Effects to Burial Angle of Slope Reinforcement Materials (비탈면 보강재의 매설각에 따른 지하수위 저감효과 분석)

  • Hyeonjun Yoon;Sungyeol Lee;Wonjin Baek;Jaemo Kang;Jinyoung Kim;Hwabin, Ko
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.8
    • /
    • pp.5-11
    • /
    • 2023
  • Due to frequent occurrences of concentrated heavy rainfall caused by abnormal climate conditions in recent years, collapses of steep slopes have been occurring frequently due to surface erosion and increased pore water pressure. Various methods are being applied to prevent slope collapses, such as increasing the resistance to movement and reducing pore water pressure. Research on these methods has been consistently conducted as they provide an efficient response to slope collapses by satisfying both the conditions of resistance to movement and pore water pressure simultaneously. Therefore, in this study, we propose an upward slope reinforcement method by burying drainage materials with an upward slope inclination, instead of the conventional horizontal application. This approach aims to satisfy both slope reinforcement and drainage functions effectively, offering a comprehensive solution for slope stabilization. Furthermore, to determine the optimal burial angle that exhibits the most effective reinforcement and drainage effects of the proposed method, we investigated the reinforcement and drainage effects under conditions where the horizontal drainage materials were set at angles ranging from 0° to 60° in increments of 10° on a representative cross-section. Additionally, indoor model experiments were conducted under the conditions of 40°, which showed the most outstanding drainage effect, and 20°, which exhibited the highest safety factor, to validate the numerical analysis results. The results showed that the burial angle of 40° exhibits a relatively higher drainage effect as with the numerical analysis results, while the angle of 20° results in inadequate drainage and observed slope collapse.

Abdominal Drainage in the Prevention and Management of Major Intra-Abdominal Complications after Total Gastrectomy for Gastric Carcinoma

  • Lim, Soo Young;Kang, Ji Hoon;Jung, Mi Ran;Ryu, Seong Yeob;Jeong, Oh
    • Journal of Gastric Cancer
    • /
    • v.20 no.4
    • /
    • pp.376-384
    • /
    • 2020
  • Purpose: The role of prophylactic abdominal drainage in total gastrectomy is not well-established. This study aimed to evaluate the efficacy of abdominal drainage in the prevention and management of major intra-abdominal complications after total gastrectomy for gastric carcinoma. Materials and Methods: We retrospectively reviewed the data of 499 patients who underwent total gastrectomy for gastric carcinoma in a high-volume institution. The patients were divided into drainage and non-drainage groups and compared for the development and management of major intra-abdominal complications, including anastomotic leak, abdominal bleeding, abdominal infection, and pancreatic fistulas. Results: The drainage group included 388 patients and the non-drainage group included 111 patients. The 2 groups showed no significant differences in clinicopathological characteristics or operative procedures, except for more frequent D2 lymphadenectomies in the drainage group. After surgery, the overall morbidity (drainage group vs. non-drainage group: 24.7% vs. 28.8%, P=0.385) and incidence of major intra-abdominal complications (6.4% vs. 6.3%, P=0.959) did not significantly differ between the two groups. The non-drainage group showed no significant increase in the incidence rate of major intra-abdominal complications in the subgroups divided by age, sex, comorbidity, operative approach, body mass index, extent of lymphadenectomy, and pathological stage. Abdominal drainage had no significant impact on early diagnosis, secondary intervention or reoperation, or recovery from major intra-abdominal complications. Conclusions: Prophylactic abdominal drainage showed little demonstrable benefit in the prevention and management of major intra-abdominal complications of total gastrectomy for gastric carcinoma.

Outcomes of Laparoscopic Abdominoperineal Resection in Low Rectal Cancer Using Different Pelvic Drainages

  • Chen, Yu-Sheng;Bo, Xiao-Bo;Gu, Da-Yong;Gao, Wei-Dong;Sheng, Wei-Zhong;Zhang, Bo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.1
    • /
    • pp.153-155
    • /
    • 2015
  • Background: The aim of this study was to establish the feasibility and efficiency of different pelvic drainage routes after laparoscopic abdominoperineal resection (LAPR) for rectal cancer by assessing short-term outcomes. Materials and Methods: Clinicopathological data of 76 patients undergoing LAPR for very low rectal cancer were reviewed retrospectively between June 2005 and June 2014. Outcomes were evaluated considering short-term results. Results: Of 76 relevant patients at our institution in the period of study, trans-perineal drainage of the pelvic cavity was performed in 17 cases. Compared with the trans-perineal group, the length of hospital stay was shorter in the trans-abdominal group, while the duration of drainage and the infection rates of the perineal wounds between two groups showed no significant differences. Conclusions: The outcomes of this study suggest that trans-abdominal drainage of pelvic cavity is a reliable and feasible procedure, the duration of drainage, infection rates and the healing rates of the perineal wounds being acceptable. Trans-abdominal drainage has a more satisfactory effect after laparoscopic abdominoperineal resection for rectal carcinoma.

Improvement of existing drainage system for leakage treatment in exiting underground structures (운영중인 지하구조물의 누수처리를 위한 유도배수공법의 개선)

  • Kim, Dong-Gyou;Yim, Min-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.4
    • /
    • pp.669-683
    • /
    • 2017
  • The objective of this study is to propose a modification of the previously proposed drainage system for catching the partial leakage of underground concrete structures. Two techniques were proposed for applying the drainage system only to the leaking parts. One was for conveying leaking groundwater to the collection point in the drainage system and the other was for conveying the collected groundwater to the primary drainage system of the underground concrete structure. Four waterproofing materials for conveying leaking groundwater to the catchment point of the drainage system, Durkflex made of porous rubber material, KE-45 silicone adhesive with super strong adhesion, Hotty-gel made of polymeric materials and general silicone adhesive were evaluated for waterproofing performance. Hotty-gel only showed perfect waterproof performance and the other three waterproof materials leaked. The modified drainage system with Hotty-gel and drainage pipe with fixed saddle to convey the leaking groundwater from the catchment point to the primary drainage system were tested on the concrete retaining wall. The waterproof performance and the drainage performance were evaluated by injecting 1,000 ml of water in the back of the modified drainage system at the 7-day, 14-day, 21-day, 28-day, 2-month and 3-month. There was no problem in waterproof performance and drainage performance of the modified drainage system during 3 months. In order to evaluate the construction period and construction cost of the modified drainage system, it was compared with the existing leaching repair method in surface cleaning stage, leakage treatment stage, and protective barrier stage. Total construction period and construction cost were compared in considering the contents of work, repair material, construction equipment, working time, and total number of workers. As a result of comparing and analyzing in each construction stage, it was concluded that the modified drainage system could save construction period and construction cost compared to the existing leaching repair method.

산성광산폐수 처리를 위한 반응벽체의 반응물질로서 산업부산물 적용에 관한 연구

  • 한완수;최재규;이재영;최상일
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.260-265
    • /
    • 2004
  • Acid mine drainage(AMD) is one of the most serious environmental concerns associated with the mining industry around the world. The objective of this study is to assess the potential of sewage sludge as a carbon source for sulfate reducing bacteria and waste lime and steel slag as a neutralize agent for acid mine drainage bioremediation for use in permeable reactive materials. The study was performed using synthetic AMD in six column experiments. The effluent solution was systematically analysed throughout the experiments. The results of the study indicated that sewage sludge, waste lime and steel slag were the most effective for the AMD treatment as a permeable reactive materials.

  • PDF

Improvement of Drainage Material for Attached Algae Growth Control in Sedimentation Basin (부착성장 조류 제어를 위한 침전지 배수로의 재질개선에 관한 연구)

  • Jun, Dae-Young;Lim, Byung-Ran;Yu, Hyun-Sun;Cho, Jin-Woo;Hwang, Jong-Hyuk;Ahn, Kyu-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.193-199
    • /
    • 2005
  • The objective of this study was to investigate the characteristics of adhesion and detachment of algae on various materials of drainage canal in the sedimentation basin. The influence of surface washability, surface roughness, phosphorous concentration was studied using stainless steel, cement block and ceramic panel. The algae attached content of cement block was higher than that of the ceramic coating panel. The attachment varied significantly with respect to exposure time and different materials. the attachment was higher on rough surface (cement block) when compared to smooth surfaces. The content of attached algae increased with increasing phosphorous concentration in water. The detachment efficient of algae was higher on ceramic panel.

Investigation of the Hydraulic Stability of Agricultural Drainage Channels Installed Water Purification Materials by using Flow-3D (Flow-3D를 활용한 수질정화체가 설치된 농업용 배수로의 안정성 조사)

  • Kim, Sun-Joo;Park, Ki-Chun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.5
    • /
    • pp.3-9
    • /
    • 2007
  • In this study, the effect of the purification materials is analyzed and tested by Flow 3D and Hydraulic model test. Three dimension numerical analysis led from the research that sees abnormal form and the size back of the water purification material conferred the flowing water conduct inside the test channel against the test condition. Comparison it analyzed the flux distribution, a water depth of the channel which establishes the water purification materials the cross section, an interval of the water purification material, a conference with general channel, it change executed. As a result, the cross section ratio of the purification materials against and a flux change from the test which it sees. The interval of the purification materials in order to prevent three dimension that follows in decrease of increase and flux must decide an interval.

Evaluation of characteristics of drainage layer according to particle size, particle size, and compositional location of aggregate using fluid analysis program (유체해석 프로그램을 이용한 골재의 입자크기 및 입도, 구성위치에 따른 배수층의 특성 평가)

  • Lim, Chang-Min;Kwon, Hyun-Woo;Kim, Young-Min;Cho, Do-Young;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.147-148
    • /
    • 2022
  • Due to recent climate abnormalities, the form of rainfall is changing to localized torrential rains. Localized torrential rains cause flooding in urban areas. In addition, in various industrial fields, there are cases where materials necessary for the process are kept outdoors, and damage from material loss and flooding of stockyards occurs during heavy rain. Accordingly, it is necessary to introduce a drainage layer where flooding is expected. This drainage layer places the aggregate inside and allows rainwater to penetrate and drain into the voids between the aggregates. However, the amount of voids differs according to the particle size distribution and particle size of the aggregate, and the drainage performance varies according to the compositional location of the aggregate. Therefore, in this study, the drainage characteristics according to the particle size, particle size, and compositional location of aggregates are analyzed using a fluid analysis program.

  • PDF

Heavy Metal Contamination and Process for Its Removal in the Vicinity of the Dalsung Cu-W Mine (달성광산(達成鑛山) 주변지역(周邊地域)에서의 중금속오염(重金屬汚染)과 이의 제거방안(除去方案))

  • Kim, Kyoung-Woong;Hong, Young-Kook;Kim, Taik-Nam
    • Economic and Environmental Geology
    • /
    • v.29 no.1
    • /
    • pp.57-63
    • /
    • 1996
  • The Dalsung copper-tungsten mine in the Taegu area, Korea was closed in 1975 and may be the sources of the heavy metal contamination in the tributary system and soil-plant system due to the mine drainage derived from the mine wastes and tailings. To examine the degree and extent of heavy metal contamination in the vicinity of Dalsung mine area, stream water and soil samples were taken and analyzed for heavy metals by ICP-AES and AAS. Highly contaminated soils are found near the Lower Tunnel No.0 ranging up to $1760{\mu}g/g$ As, $2060{\mu}g/g$ Cu, $1120{\mu}g/g$ Pb and 346 ${\mu}g/g$ Zn. From the results of the sequential extraction methods for the metal speciation, the heavy metals in soils may be derived from soil parent materials and acid mine drainage. With the processes for the heavy metal removal, most of the heavy metal ions in the acid mine drainage are removed by being exchanged with Ca ions held by the bentonite, hydroxyapatite and calcium hydoxide.

  • PDF

The Changes in Drying Efficiency and Paper Properties of Linerboard by the Application of the Fractions of Wood Powder as a Bulking Agent (목질 벌크향상제 분획별 적용에 따른 라이너지의 건조효율 및 물성변화)

  • Kim, Dong-Seop;Yoon, Do-Hyun;Sung, Yong Joo
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.46 no.5
    • /
    • pp.61-68
    • /
    • 2014
  • The energy efficiency of papermaking process becomes more significant because of various new regulation of the energy consumption and the green house gas emission. In this study, the effects of wood powder addition on the drainage and the drying efficiency of the OCC based paper products, linerboard, were deeply investigated for improving energy efficiency. The fractionation of wood powder depending on the size were conducted. The bigger size of wood powder resulted in the higher bulk and the higher drainage efficiency, but the lower paper strength. The drying efficiency were in detail evaluated depending on the drying process level. In the first section of drying process until the 80% solid level, there were no significant changes in the drying efficiency by the addition of wood powder. However, after the 80 % solid level, the drying efficiency was greatly improved by the addition of wood powder. Those results showed the addition of wood powder could greatly affect not only the drainage in forming and wet pressing but also the drying process.