• 제목/요약/키워드: Drainage effect

검색결과 629건 처리시간 0.023초

지하철의 터널 배수체계에 따른 결함 사레 (Case Study on defects of Tunnel Drainage in Subway)

  • 김석조;이재욱;조성우;신용석
    • 한국터널공학회:학술대회논문집
    • /
    • 한국터널공학회 2005년도 학술발표회 논문집
    • /
    • pp.292-298
    • /
    • 2005
  • Tunnel in subway should be designed as a water-proof type tunnel as much as possible but it is difficult to make it come true due to several facts, such as construction technique and cost. A drainage type tunnel as a substitute of a water-proof tunnel lead to the increase of water pressure on the concrete lining that make bad effect to tunnel structure when it has some problem to operate the drainage system. Throughout studying about cases on defects of tunnel drainage in subway We hope it contributes to tunnel maintenance.

  • PDF

양이온성 구아검과 콜로이달 실리카를 이용한 마이크로파티클 보류시스템의 탈수 및 전단안정성 (Drainage and Shear Stability of Microparticle Retention Systems Based on Cationic Guar Gums and Colloidal Silicas)

  • 함충현;이학래
    • 펄프종이기술
    • /
    • 제40권2호
    • /
    • pp.1-7
    • /
    • 2008
  • The trend of using more hardwood and recycled fibers, and closing more tightly of the paper mill white water system has resulted in build-up of fines as well as organic and inorganic contaminants in the white water. This changes in papermaking wet end requires developing chemical additive system that provides good fiber retention and drainage in closed white water system. In this study the effect of charge densities and chemical characteristics of microparticle systems consisted of cationic guar gums and anionic colloidal silica sols on drainage and retention have been examined. Results showed that higher charge density of cationic guar gum and anionic colloidal silica sol gave better retention and drainage. Particularly highly structured silica gave greater retention efficiency.

자력에 의한 산성 광산 배수의 처리 - 철(Fe) 성분의 제거- (The Treatment of Acid Mine Drainage - The removal of Iron(Fe) component-)

  • 송근호;이광래
    • 산업기술연구
    • /
    • 제32권A호
    • /
    • pp.21-27
    • /
    • 2012
  • The characteristics of floc formation of the iron(Fe) ions contained in the acid mine drainage was studied for developing the process treating the acid mine drainage. The iron(Fe) ions were formed into flocs by the acid-base reaction with the added $Ca(OH)_2$. The molal ratio of iron(Fe) vs $Ca(OH)_2$ was one of major control variables in treatment; pH change, iron(Fe) ions concentration in treated drainage, DO (dissolved oxygen content). In addition, the air gave much effect on the color of the $iron(Fe)-Ca(OH)_2$ flocs and the attachment to magnet. The attaching to the magnet of the flocs formed in the air was much less than the case without air.

  • PDF

도로터널의 모사시험을 통한 배수공 스케일 억제 기술 평가 (An Evaluation of Treatment Technologies for Anti-scale in Drainage Works Using Simulation Test of Road Tunnel)

  • 박은형;남중우;한윤수;김현기;천병식
    • 한국지반공학회논문집
    • /
    • 제29권7호
    • /
    • pp.5-15
    • /
    • 2013
  • 노후화된 터널에서 배수공의 막힘현상은 중요한 문제점으로 대두되며, 장기적으로는 배수시스템에 폐색현상을 일으킨다. 배수시스템에서의 침전물 방지를 위한 요소기술 검증을 위해 본 연구에서는 도로터널의 토사층 및 라이닝을 모사하여 배수공의 유출수에서의 침전현상을 살펴보았다. 또한 기존의 배수공들은 대부분$5^{\circ}$ 이하로 설치되었기 때문에 배수공의 기울기를 변화시켜가며 시험하였다. 배수공의 기울기를 $2^{\circ}$로 한 경우에는 퀀텀스틱은 스케일의 생성을 방지하는 데 효과가 있었으나 자화장치는 효과가 없는 것으로 나타났다. 배수공의 기울기를 $5^{\circ}$로 한 경우에는 퀀텀스틱과 자화장치 모두 배수공내 스케일의 생성을 방지하는 데 효과가 있었으나, 특히 퀀텀스틱이 자화장치보다 더욱 효과가 있는 것으로 나타났다.

PVDF(Polyvinylidene Fluoride) 필름형 트랜스듀서 하이브리드 터널배수재에 대한 오염퇴적물 제거효율의 현장 적용성 평가 (Assessment of Field Application of Contaminated Sediment Removal Efficiency Using PVDF Combined Hybrid Tunnel Drainage)

  • 신진화;문준호;김영욱
    • 한국산학기술학회논문지
    • /
    • 제20권3호
    • /
    • pp.513-519
    • /
    • 2019
  • 배수 시스템에서 오염퇴적물이 장기간 발생하게 되면 배수관 폐색현상을 일으켜 유지관리가 어렵고 배수관의 잔류수압이 커져 파손의 위험이 있다. 이에 본 연구에서는 PVDF 필름에 의해 발생하는 진동에너지를 활용하여 물리/화학적 폐색에 의한 터널배수 시스템 폐색을 감소시키는 시스템을 구축하였다. 또한, PVDF 필름을 기존 배수재와 융합한 하이브리드 배수재와 역압전 효과를 일으킬 수 있는 구동장치로 배수재 유지관리 시스템을 개발하였다. 터널 배수관 유지관리 성능을 고찰하기 위하여 실내조건에서 오염퇴적물을 모사하고 진동조건에서 폐색저감 효율을 관찰하였다. 그 결과 개발된 PVDF 필름 구동 장비로 20분 내외의 진동에너지를 발생하여 씻겨나간 오염퇴적물의 잔류면적을 측정한 결과 74.62%의 오염퇴적물 제거효과를 볼 수 있었다. 현장 적용성 평가를 위하여 PVDF 필름을 배수관에 부착하고 장기적으로 음압측정을 하여 실내실험으로부터의 측정 음압과 비교하여 현장실험의 대응율을 제시하였다. 현장실험은 터널 배수관으로부터 내부에 폐색이 주로 발생하는 구간인 종배수관과 횡배수관에 PVDF 필름을 부착하였고 터널현장 음압측정 실험으로부터 오염물퇴적 제거효율은 실내실험대비 현장 대응율은 90% 이상으로 확인됐다.

일정변형률 압밀시험을 이용한 방사배수 조건하에서의 압밀해석 (Consolidation at Constant Strain Rate for Radial Drainage)

  • 윤찬영;장인성;정충기
    • 한국지반공학회논문집
    • /
    • 제18권4호
    • /
    • pp.147-157
    • /
    • 2002
  • 본 연구에서는 방사방향의 배수조건을 갖는 점성토의 압밀특성을 짧은 시간에 정확하게 평가할 수 있는 방사배수 일정변형률 압밀시험을 위한 시험기와 해석이론을 개발하였다. 개발된 시험기 및 해석이론에 대한 적용성을 검토하기 위하여 성형시료 및 불교란 시료에 대하여 방사배수 일정변형률 압밀시험과 단계하중 압밀시험을 실시하였다. 압밀곡선으로부터 평가되는 압밀정수 및 압밀계수에 대한 비교, 분석을 통하여 제안된 시험기 및 이론의 신뢰성과 적용성을 평가하였고, 방사배수 시험과 더불어 수행된 연직배수 일정변형률 압밀시험과 단계하중 압밀시험을 통하여 배수방향에 따른 영향과 시험기 및 해석이론의 적용성을 분석하였다. 또한, 일정변형률 압밀시험시 발생하는 과잉간극수압에 대한 분석을 통하여 간극수압의 발생 양상 및 실험결과에 미치는 영향을 확인하였다.

도시내 배수설비 슬러지가 악취에 미치는 영향 연구 (Effect of municipal sludge from drainage facility on foul smell)

  • 유대현;박지훈;이용훈;이장훈;강선홍
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.315-324
    • /
    • 2014
  • The residents' odor complaint is steadily increasing by odor causing from sewage system. A current drainage facilities and septic tank are included in the individual sewerage according to Sewerage Act. However, definitions and legal standards of drainage tank are insufficient. In addition, specifications and maintenance standards related to structure and size are not established. In this research, effect of drainage tank in individual sewage facilities on the odor occurrence was studied and the concentrations of $H_2S$ and composite odor were measured. From the measurements, the concentration of $H_2S$ and composite odor were 1 ppm ~ 5 ppm and 1.04 OU ~ 4.05 OU, respectively, before pump operation. Also, the concentration of $H_2S$ and composite odor were 5 ppm ~ 33 ppm and 5.10 OU ~ 35.04 OU, respectively, after pump operation. The concentration of SS in the effluent from drainage tank was ranged from 840 mg/L to 1,980 mg/L. These high concentration of SS seemed to be the major source of foul smell when high concentrated suspended solids in the public sewerage system were decomposed and then emitted. In this research, correlation coefficient ($R^2$) between $H_2S$ and composite odor before and after pumping were 0.925 and 0.918, respectively.

Comparison of Outcomes and Recurrence in Chronic Subdural Hematoma Patients Treated by Burr-Hole Drainage with or without Irrigation

  • Choi, Jongwook;Whang, Kum;Cho, Sungmin;Kim, Jongyeon
    • Journal of Trauma and Injury
    • /
    • 제33권2호
    • /
    • pp.81-87
    • /
    • 2020
  • Purpose: Chronic subdural hematoma (CSDH) is a common disease in elderly patients and is usually treated by burr-hole drainage. However, the optimal surgical technique for treating CSDH has not been determined. In this study, we analyzed outcomes and recurrence rates after burr-hole drainage with or without irrigation in patients with CSDH. Methods: Eighty-two CSDH patients treated with burr-hole drainage at Wonju Severance Christian Hospital from March 2015 to June 2016 were enrolled in this study. The subjects were divided into three groups based on the surgical technique performed as follows: single burr-hole drainage without irrigation (group A, n=47), single burr-hole drainage with irrigation (group B, n=14), or double burr-hole drainage with irrigation (group C, n=21). These three groups were compared with respect to clinical and radiological factors and the recurrence rate, and independent factors predicting recurrence were sought. Results: After burr-hole drainage, CSDH recurred in 15 (18.3%) of the 82 patients, and six patients (7.3%) required reoperation. More specifically, recurrence was observed in 12 patients (25.5%) in group A, one (7.1%) in group B, and two (9.5%) in group C. The number of burr-holes did not significantly affect recurrence (odds ratio [OR]=0.38; 95% confidence interval [CI]: 0.60-2.38), but irrigation had a significant effect (OR=0.20; 95% CI: 0.04-0.97). Conclusions: This study shows that irrigation during burr-hole surgery in CSDH patients significantly reduced the risk of recurrence, regardless of the number of burr-holes used. We therefore recommend the use of active irrigation during burr-hole drainage surgery in CSDH patients.

벼 건답직파 재배시 중간낙수가 생육 및 도복에 미치는 영향 (Influence of Midsummer Drainage on Growth and Lodging of Rice in Direct Seeding on Dry Paddy)

  • 최민규;김상수;이선용;최선영
    • 한국작물학회지
    • /
    • 제40권5호
    • /
    • pp.574-579
    • /
    • 1995
  • 건답직파 재배시 중간낙수처리가 도복에 미치는 영향을 구명하고자 1991년에 동률벼를 공시, 5월 1일에 휴립 세조파하고, 파종후 30일에 심수하고 심수후 20일 부터 10일 간격으로 1∼3회 낙수처리하여 도복관련형질 및 수량을 검토한 결과를 요약하면 다음과 같다. 1. 간장 및 절간장은 낙수회수가 많을수록 짧아지고 간벽은 두꺼워졌으나, 줄기 굵기는 상시심수에서 다소 굵었다. 2. 낙수회수가 많을수록 중심고는 낮아지고 좌절중은 무거워서 도복지수는 적어졌으며, 낙수회수가 많을수록 뿌리량이 많아지고 뿌리의 심층분포비율이 높아지는 경향이었다. 3. 도복은 상시심수에서는 심하게 발생되었으나 낙수회수가 많을수록 경감되어 2∼3회 낙수처리에서는 도복이 발생되지 않았거나 경징하였다. 4. 수량은 등숙후기(출수후 35일)에 도복이 발생되어 상시심수와 낙수처리간에 차이가 없었으나, 현미중의 청미비율은 낙수회수가 많을수록 감소되는 경향되었다. 5. 따라서 건답직파 재배시 심수후 20일부터 10일간격으로 2∼3회 중간낙수 처리하는 것이 도복방지를 위한 적절한 물관리 방법이라고 생각된다.

  • PDF

노반 및 공극 막힘 현상에 따른 투수성 보도블록의 불포화 상태에서의 배수 성능에 관한 실험적 연구 (Effect of Bedding Layer and Clogging on Drainage Capacity of Pervious Sidewalk Block in Unsaturated Condition)

  • 서다와;윤태섭
    • 한국지반공학회논문집
    • /
    • 제32권5호
    • /
    • pp.37-48
    • /
    • 2016
  • 본 연구는 실제 시공 환경에서 투수성 보도블록의 표면 유출 및 배수 특성을 알아보고자 하였으며, 표층 및 노반을 포함한 시편을 대상으로 불포화 상태에서 도심 내 우수 조건을 고려한 배수 실험을 진행하였다. 일정한 시간 간격을 두고 반복적인 배수 실험 및 공극 막힘 실험이 시행되었으며, 정량적 분석을 위하여 3D X-ray CT 이미지 분석 및 증발 실험을 시행하였다. 실험 결과, 시간 간격 동안 발생한 증발로 인해 공극 내 물이 공간적으로 재분포되어 표면 유출을 야기시키는 것으로 나타났다. 특히, 공기에 노출되어 있는 표층보다 시편 하부에 위치한 노반의 공극 변화가 투수성 보도블록의 배수, 증발 등 전체적인 수리학적 거동을 크게 저하시켰다. 또한 공극 내 침전물은 증발로 인한 변화를 증진 시키며, 이 때 저하된 배수 성능은 쉽게 회복되지 않는 것으로 나타났다. 그리고 선행우수조건에 의하여 배수 성능이 저감되면서 최대 표면 유출 높이가 증가하는 것으로 나타났다.