• 제목/요약/키워드: Drainage area

검색결과 1,004건 처리시간 0.026초

용수로상의 배수구조물계획에 대하여 -배수잠관을 중심으로- (On the Planning of Drainage Structures in Irrigation Channels. -Special Emphasis on the Drainage Inverted Siphon-)

  • 김철기
    • 한국농공학회지
    • /
    • 제12권4호
    • /
    • pp.2078-2083
    • /
    • 1970
  • The purpose of this study is to give the data neccesary for improving the planning of drainage structures, specially inverted siphons, in irrigation channels. With the samples of 15 drainage inlets, one drainage flume, 16 drainage inverted siphons and 6 drainage culverts in the 3 lines of irrigation channel under Chong-Won Irrigation Association, author abtained the following results. 1. It is presumed that design drainage discharge should be determined with some additional reserves, on the basis of the maximum rainfall intensity in local area and the size of drainage area on the topographical map, avoiding the way of eye measure. 2. Location of drainage inlet should be kept away from the place where topography can make lots of wash load, but when unavoidably allowing the inflow into irrigation channel, wash load outlet with even the purpose of drainage, or drainage flume in stead of drainage inlet should be taken account of. 3. It is presumed that drainage flume may be the structure which can perform its function from a structural point of view as far as topography permits. 4. Drainage inverted siphon should be avoided at any place as much as possible; a) In case that location of the siphon would be permitted only at paddy field, drainage area hauing the amount of discharge which requires more than 90cm in diameter could only be allowed. b) In this case, crest elevation of the tank of both inlet and outlet, at least, should not be lower than the surface level of paddy field. c) As far as topography and stratum permit, ratio of depth of outlet tank to head drop should be decreased as much as possible so that discharging efficiency of wash load could increase. d) In case of avoiding the setting of the siphon, irrigation aqueduct, irrigation inverted siphon, or drainage flume should be recommended in accordance with topography. 5. Discharging capability of wash load by drainage culvert appeared to depend hardly upon the diameter of the culvert, but greatly upon the location, specially near village, for there stones and dirts dumped may considerably be piled up. So, a counter plan for that is required.

  • PDF

저수지의 퇴사에 관한 연구 (Study on Sedimentation in Reservoir)

  • 류희정;김치원
    • 물과 미래
    • /
    • 제9권2호
    • /
    • pp.67-75
    • /
    • 1976
  • With 9 existng reservoirs selected in the Sab-Gyo River Basin, the sedimentation of the reservoirs has been calculated by comparing the present capacity with the original value, which revealed its reduced reservoirs capacity. The reservoirs has a total drainage area of 6,792 ha, with a total capacity of 1,204.09 ha-m, and are short of water supply due to reduction of reservoirs capacity. Annual sedimention in the reservcire is relation to the drainage area, the mean of annual rain fall, and the slop of drainage area. The results of obtained from the investigation are summarized as follow; (1) A sediment deposition rate is very high, being about $9.19{m}^3/ha$ of drainage area, and resulting in the average decrease of reservoir capacity by 19.1%. This high rate of deposition could be mainly attributed to the serve denvdation of forests due to disor derly cuttings of tree. (2) An average unit storage of 415.8mm as the time of initial construation is decreesed to 315.59mm at present, as resultting, we could'nt supply water at 566.24ha. (3) A sediment deposition rate as a relation to the capacity of unit drainage area is as follow; $Qs=1.43 (c/a)^{0.531}$ (4) A sediment deposition rate as a relation to the mean of annval rainfall is as follow; $Qs=672.61 p^{0.024}$ (5) A sediment deposition rate as a relation to the mean slop of drainage area is follow; $Qs=267.21 S^{0.597}$

  • PDF

도시 녹지기반 특성에 따른 강우 유출수 비교 분석 - 성남시 분당신도시를 사례로 - (A Comparative Analysis of Stormwater Runoff with Regard to Urban Green Infrastructure - A Case Study for Bundang Newtown, SungNam -)

  • 박은진;강규이;이현정
    • 한국환경복원기술학회지
    • /
    • 제11권6호
    • /
    • pp.1-10
    • /
    • 2008
  • The study was aimed at analyzing the relationship between the characteristics of urban green infrastructure and stormwater runoff in a small urban watershed composed of 22 drainage basins. The green areas of which soils are not sealed and allow water infiltrate, were examined for different types of green spaces. In a comparative study for drainage basins of which green spaces are 15.5% and 34.4%, respectively, runoffs were not different with the size of green space. It was attributed to that the increase of runoff by greater road area offset the advantage of greater green area. Another comparative measurement of runoff for drainage basins with similar green area size showed that runoff decreased with greater permeable area (school ground area) and smaller road area. The runoff measurements could address that runoff rates are affected not only by green area size but also by the type of green area and other land covers related to permeability and flow into drainage. It implicated that the improvement of urban green infrastructure as a functional unit for water infiltration and interception is important for stormwater runoff management.

저수지의 퇴사에 관한 연구 -진양지구를 중심으로- (A Study for Sedimentation in Reservoir -on district of Chin Young-)

  • 류시창;민병향
    • 한국농공학회지
    • /
    • 제17권3호
    • /
    • pp.3840-3847
    • /
    • 1975
  • With 30 excisting reservoirs in the Chin-Young area, the Sedimentation of the reservoirs has been calculated by comparing the present capacity with the original value, which revealed its reduced reservoir capacity. The reservoirs has a total drainage area of 3l4l ha, with a total capacity of 43.23 ha-m, and are short of water supply due to reduction of reservoir capacity, Annual sedimentation in the reservoir is relation to the drainage area, the mean of annual rainfall, and the slop of drainage area. The results of obtained from the investigation are summarized as follows: (1) A Sediment deposition rate is high, being about 7.03㎥/ha of drainage area, and resulting in the overage decrease of reservoir capacity by 16.1%. This high rate of deposition coule be mainly attributed to the serve denudation of forests due to disorderly cuttings of tree. (2) An average unit storageof 116mm as the time of initial construction is decreased to 95.6mm at present. This phenomena cause a greater storage of irrigation water, sinceit was assumed that original storage quantity itself was already in short. (3) A sediment deposition rate as a relation to the capacity of unit drainge area is as follow: Qs=1.27(C/A)0.6 and standard deviation is 185.5㎥/$\textrm{km}^2$/year. (4) A sediment deposition rate as a relation to the mean of annual rainfall is as follow: Qs=21.9p10.5 and the standard deviation is 364.8㎥/$\textrm{km}^2$/year. (5) A sediment deposition rate as a relation to the mean slop of drainage area is follow: Qs=39.6S0.75 and the standard deviation is 190.2㎥/$\textrm{km}^2$/year (6) Asediment deposition rate as a relation to the drainage area, mean of rainfall, mean of slope of drainage area is: Log Qs=0.197+0.108LogA-6.72LogP+2.20LogS and the standard deviation is 92.4㎥/$\textrm{km}^2$/year

  • PDF

도시하수도망에 대한 유출모형의 남용과 유출해석 (Runoff Analysis and Application of Runoff Model of Urban Storm Drainage Network)

  • 박성천;이관수
    • 한국환경보건학회지
    • /
    • 제22권4호
    • /
    • pp.33-42
    • /
    • 1996
  • This research is to show the application of runoff model and runoff analysis of urban storm drainage network. the runoff models that were used for this research were RRL, ILLUDAS, and SWMM applicative object basin were Geucknak-chun and Sangmu drainage basin located in Seo-Gu, Kwangju. The runoff analysis employed the design storm that distributed the rainfall intensity according to the return period after the huff's method. The result from the comparative analysis of the three runoff models was as follows The difference of peak runoff by return period was 20-30% at Sangmu drainage area of $3.17 Km^2$, while less than 10% at Geucknak-chun drainage area of $12.7 Km^2$. The peak runoff were similar to all models. At the runoff hydrograph the times between rising and descending points were in the sequence of RRL, ILLUDAS and SWMM, but the peak times were similar to all models. The conveyance coefficient to examine the conveyance of the existing drainage network was 0.94-1.37, which means insecure, in Geucknak-chun drainage basin and 0.69-1.16, which means secure, in sangmu drainage basin.

  • PDF

일제하 양배수장형 수리조합에서의 양수기술과 단위용·배수량의 변천 (리뷰 논문) (Transition of Pumping Technology, Irrigation Water Requirement, and Unit Area Drainage Discharge at Pumping Station-based Irrigation Associations in South Korea during Japanese Colonial Period (in Review))

  • 김진수
    • 한국농공학회논문집
    • /
    • 제63권3호
    • /
    • pp.59-73
    • /
    • 2021
  • The purpose of this study is to investigate transition of pumping technology, irrigation water requirement, and unit area drainage discharge at the Pumping station-based Irrigation Associations (PIAs) in South Korea during Japanese colonial period (1910-1945). The PIAs established pumping stations and embankments along rivers for the purpose of irrigation, drainage and flood prevention until the mid-1920s. From the late 1920s after major river improvement projects, newly established PIAs did not include the flood prevention in their purpose of establishment. The design criteria of the irrigation and drainage projects, such as irrigation water requirements, design rainfall, and allowable ponding duration were decided according to the circumstances of PIAs. The gross irrigation water requirement of paddy fields increased from the 1920s to the 1940s, and reached the level of 0.0020 m3/s/ha (19 mm/d) in the 1940s for the fairly good irrigation status in the drought. The great floods of 1930, 1933, and 1934 triggered the increase in drainage discharge in the late 1930s, leading to the unit area drainage discharge of 0.9-2.6 m3/s/km2 for natural drainage and 0.3-1.1 m3/s/km2 for pump drainage. Therefore, several PIAs near the major rivers could avoid repetitive floods damage.

내.외향류 방사형 압밀/투수 특성에 관한 연구 (The characteristics of radial consolidation & permeability on the inflow & outflow condition)

  • 천홍래;김지용;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.109-116
    • /
    • 1999
  • This study is to make clear for the characteristics of radial drainage consolidation/permeability At the result of the radial drainage consolidation / permeability test, the permeability of outflow drainage condition is higher than Inflow drainage condition and the time for the end of consolidation, outflow drainage condition is shorter than inflow drainage condition. So drainage area ratio test and control of hydraulic gradient test are carry out to analysis this result. Finally, compared with the characteristics on the condition of inflow and outflow permeability and consolidation.

  • PDF

DEM을 이용한 수로망 산정 기법에 따른 유역의 배수구조 평가 (Evaluation of DEM-based Channel Network Delineation Methods on Watershed Drainage System)

  • 이기하;윤의혁;김주철;정관수
    • 대한토목학회논문집
    • /
    • 제31권1B호
    • /
    • pp.1-11
    • /
    • 2011
  • DEM을 이용한 수로망의 생성은 수문해석모형의 적용을 위한 전처리 과정으로써 실제 유역시스템의 배수구조를 결정하는 중요한 인자로 활용된다. 본 연구에서는 DEM으로부터 합리적인 수로망 추출과정 수립을 목적으로 보편적으로 사용되고 있는 면적한계기준과 국부경사와 기여면적사이의 특성에 근거한 경사-면적한계기준 기법을 이용하여 수로망을 생성하고 지형법칙에 의거하여 각 기법에 따른 소규모 유역(진안천 유역; $18.28km^2$) 배수구조의 신뢰성을 평가하였다. 그 결과, 면적한계 기준 기법은 수원유역의 크기의 인위적 결정에 의해 지형법칙을 만족시키지 못하고 유역전체의 배수구조를 왜곡되게 묘사한 반면, 경사-면적한계기준 기법의 경우 물리적인 지형법칙을 만족시키는 우수한 결과를 나타냈다. 따라서 경사-면적한계기준 기법은 DEM 기반의 수문모형을 적용 시 효율적이고 객관적인 수로망 생성을 위한 방법론으로서 활용이 가능하리라 판단된다.

Analysis of Urban Flood Damage Using SWMM5 and FLUMEN Model of Sadang Area in Korea

  • Li, Heng;Kim, Yeonsu;Lee, Seungsoo;Song, Miyeon;Jung, Kwansue
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.396-396
    • /
    • 2015
  • Frequent urban floods affect the human safety and economic properties due to a lack of the capacity of drainage system and the increased frequency of torrential rainfall. The drainage system has played an important role in flooding control, so it is necessary to establish the effective countermeasures considering the connection between drainage system and surface flow. To consider the connection, we selected SWMM5 model for analyzing transportation capacity of drainage system and FLUMEN model for calculating inundation depth and time variation of inundation area. First, Thiessen method is used to delineate the sub-catchments effectively base on drainage network data in SWMM5. Then, the output data of SWMM5, hydrograph of each manhole, were used to simulate FLUMEN to obtain inundation depth and time variation of inundation area. The proposed method is applied to Sadang area for the event occurred in $27^{th}$ of July, 2011. A total of 11 manholes, we could check the overflow from the manholes during that event as a result of the SWMM5 simulation. After that, FLUMEN was utilized to simulate overland flow using the overflow discharge to calculate inundation depth and area on ground surface. The simulated results showed reasonable agreements with observed data. Through the simulations, we confirmed that the main reason of the inundation was the insufficient transportation capacities of drainage system. Therefore cooperation of both models can be used for not only estimating inundation damages in urban areas but also for providing the theoretical supports of the urban network reconstruction. As a future works, it is recommended to decide optimized pipe diameters for efficient urban inundation simulations.

  • PDF