• Title/Summary/Keyword: Drainage Area

Search Result 1,005, Processing Time 0.026 seconds

Optimum Drainage Time for Rice Quality in Tidal Reclaimed Area (간척지 토양에서 벼 재배시 염농도별 완전 낙수시기)

  • Choi Weon-Young;Lee Kyu-Seong;Ko Jong-Cheol;Moon Sang-Hoon;Kim Chung-Kon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.spc1
    • /
    • pp.85-87
    • /
    • 2005
  • This study was conducted to identify the effective dyainage-time influencing rice yield and grain quality on a reclaimed saline soil, the experiment conducted at the Gyehwado substation of the Honam Agricultural Research Institute from 2002 to 2003. The experimental field contained $0.1\%\;and\;0.3\~0.4\%$ NaCl in soil solution, respectively. The experiment involved salinity levels as main plot and sub-plot where consisted of 6 treatments in a split plot design with three replicates. Rice yield performance showed a maximum at drainage-time for 35 days after flowering under medium salinity level, but indicated only $64\%$ of yield level compare to low soil salinity. Percentage of well-shaped rice was high in low soil salinity indicating there aye severe affection for grain quality in medium soil salinity regardless water drainage-time.

Application of the Fuzzy Models for the Efficient Operation of Pumping Station (배수펌프장의 효율적인 운영을 위한 퍼지모형의 적용)

  • Kim, Yun-Tae;Shim, Jae-Hyun;Chung, Jae-Hak;Ahn, Jae-Chan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.3 s.14
    • /
    • pp.51-60
    • /
    • 2004
  • Urban flood damage has been caused by drainage deficiency. One of the methods to solve this problem is to construct detention basin and Pumping station and to pump out the water to the river. However, because of rapid urbanization, the capacity of drainage pipelines is sometimes not sufficient enough during the rainy season. Therefore, even though we have enough pumping stations, the inflow of surface water never reaches to the detention area, causing floods in urban area. This research is to find improvement of urban drainage system, estimating drainage pipeline risk. Also, eight models for a computer program were developed for practical use. The models were verified changing precipitation duration, intensity, design period, time distribution model, and etc. This verification was processed focusing that the model can regulate the water level in the detention basin and minimize the effect downstream. As a result Fuzzy models were found to be efficient to lower the water level in detention basin, and decreased about 8 cm in water level of downstream.

A Runoff Simulation Using SWAT Model Depending on Changes to Land Use in Jeju Island (SWAT 모형에 의한 제주도 외도유역의 토지이용변화에 따른 유출량 산정)

  • Han, Woong-Ku;Yang, Sung-Kee
    • Journal of Environmental Science International
    • /
    • v.18 no.9
    • /
    • pp.1057-1063
    • /
    • 2009
  • Since Jeju island has depended a water resource on the underground water because of a poor development of the surface flow, Jeju island is in need of the surface resource development to prevent the future shortage of the underground water due to excessive development and use of it. The study shows that the SWAT model(continuous rainfall-runoff model) is applied to estimate the outflow in the drainage watershed area, where it has been urbanized through the change of the land, such as a tourism development, cultivation, housing, and impervious layer road development. Near Oaedo watershed area in Jeju island, weather and topographical SWAT input data were collected, and compared the outflow change of past and present.

A study on the fluid noise in the pipe (파이프 내부의 유동소음에 관한 연구)

  • Hwang, Ki-Soo;Choi, Myung-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1435-1439
    • /
    • 2009
  • Drainage noise with making think about what they do disturbs neighborhoods live under source of noise. elbow pipe built in the house. the general elbow pipe has a rectangular elbow because of easiness when the plan set up or executing. therefore, free falling fluid impacts on the wall of the elbow pipe almost at one point. in this paper, to disperse the potential energy, the shock decentralizes from tiny area to large area. And It is considered how the characteristics change according to the noise of transformed shape of pipe, then researched the effectiveness of transformed pipe configuration.

  • PDF

Comparative Study on Evaluating Low-Flow in Ungauged Watershed (미계측 유역에서 저수량 산정 방법 비교 연구)

  • Baek, Kyong Oh
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • In this study, the methodologies for evaluating the low-flow at the ungauged watershed are reviewed and assessed. The ungauged watershed can be classified into different situations such as the partially recorded watershed and the completely ungauged watershed. The extension method and the percentile method are used to evaluated the low-flow at the partially recorded watershed. The drainage-area ratio method and the regional regression method are used at the completely ungauged watershed. These four methods are applied and validated based on the hydrological and geometric data acquired from unit watersheds in Han River basin for TMDLs. In case of partially recorded watershed, the values of low-flow evaluated by the extension method are in better agreement with measured flow-rate rather than those by the percentile method. In case of completely ungauged watershed, the drainage-area method is broadly used to estimate the low-flow. It must be paid attention to consider the treated sewage discharge produced at watersheds when applying the method.

Characteristics of Pollution Source Structures and Temporal and Spatial Discharge from the Drainage Basin of a Reclaimed Area (간척지 담수호유역의 오염물질 배출구조 및 시공간적 유출특성)

  • 엄명철;공동수;정동일;권순국
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.739-746
    • /
    • 1999
  • Discharge characteristics of organic materials and nutrients were estimated in the catchment area of relaimed area-Saemankeum-. Discharge load of BOD5 was high in the domestic system, while nitrogen and phosphorous were discharged mainly from the livestock system and the land . Load was so dependent on the precipitation that it increased in the rainy season, particulary in nitrogen and phosphorus. Loads from nonpoint sources in this area were higher compared with others.

  • PDF

Studies on Wet Paddy Field Underdrainage Improvement in the Gum-Ho Area (I) (금호지구 저습답의 암거배수효과에 관한 연구(I))

  • 김조웅;김시원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.4
    • /
    • pp.82-95
    • /
    • 1980
  • This paper complies the results of the studies so far made on the subsoil improvement of subsurface drainage systems for wet paddy fields (those were located in the Gum-Ho area in Kyung Buk province) which had poor permeability and a high water table. In general, a drainage problem is an excess of water on the ground surface which can effect the productivity and bearing capacity of the soil. With drain pipe systems, (According to their depths and spacing) it may be possible to correct that problem. The experimentation consisted of three test plots, two of which included drain pipe systems with varing depths and width spacing of the pipes. The third plot (C) was an ordinary plot being exempt of a drain pipe system. In detail, the depth of plot A was 80 cm, and the width spacings began at 2. Om and increased by 2. Om up to 10. 0m. The depth of plot B was 60cm and the width spacing was the same as plot A. These tests were performed to research specific details; such as crop yeild, bearing capacity of the soil, the amount of underdrainage, surface cracks, root distribution, the water table level, the consumptive water depth and the soil moisture content. The test period lasted three years, from 1977 thru 1979. The results obtained were as follows: 1. During the test period, the weather conditions for the area tested were in accordance with the annual average for that area. Furthermore the precipitation factor during the spring cultivation season, the intermediate drainage period and the harvest drainage period was of optimum conditions for controling surface cracks, because of less precipitation than evaporation. 2. The difference in the level of the ground water table in plots A and B was hardly noticable, but the difference in the test plots and the ord. plot was greatly noticable. The test plots (A, B) were 30 to 40cm lower than the ordinary plot. On the whole, the ground water table of the ord. plot always stayed at a level of 15-20cm beneath the surface of the soil, the ground water table of the test plot A showed The difference in the depth of the pipe lower than the test plot B, while the test plots showed a remarkable descending effect. 3. The soil temperature in plot A was slightly core than in plot B with a difference of 0. 47$^{\circ}$C, but plot A was 1. 6$^{\circ}$C higher than the ord. plot during the flooding period, but after drainage the temperature difference climed to 2. 0$^{\circ}$C. 4. During the 3rd test year, the values of the cracks were recorded with the values of 59cm in plot A, 42cm in plot B and 15cm in the ordinary plot. Plots A and B had increased 2.5 times the value of the first year while the ordinary plot had remained the same. 5. The root weight of the rice was measured at a value of 77.2 gr. for plot A, 73.5 gr. for plot B and 65.3 gr. for the ord. plot. Therefore, the root growths in plots A and B were much more energetic than in the ord. plot. 6. The consumptive water depth measured during the 3rd year resulted in the values of 26. 0mm per day for plot A, and 24.9 mm per day for plot B, respectively. Therefore, both plot A and plot B maintained the optimum consumptive water depths, but the ordinary plot only obtained the value of 12.3 mm per day, which clearly showed less than the optimum consumptive water depth which is 20 to 30 mm/day. 7. The soil moisture content is in direct relationship to the ground water level. During drainage, test plot A decreased in its ground water level much more rapidly than the other two plots. Therefore, plot A had a much less soil moisture content. But this decreased water level could be directly effected by the weather conditions. 8. The relationship between the bearing capacity and the soil moisture content were directly inversely proportional. It can be assumed that the occurence of soil creaks is limited by the soil moisture content. Therefore, the greater the progress of the surface creaks resulted in a greater bearing capacity. So, tast plot A with a greater amount of surface cracks than the other test plots resulted in a greater bearing capacity. But, the bearing capacity at the harvest season could be effected by the drainage during the intermediate drainage period and by the weather conditions. 9. Comparing the production of the test plots to the ord. plot; there was an increased value of 840kg for plot A, 755kg for plot B and 695kg for the ord. plot in the rough rice. Therefore, plot A had an increase of 20% over the ordinary plot. The possibility of producing double crops was investigated. The effects on barley production in the test plots showed a value of 367kg per 10 acres, which substantiated the possibility of double crops because that value showed an increased value over the average yearly yield for those uplands. 10. So as a result, it can be recommended that by including a drain pipe system with the optimum conditions of an (80cm centimeter) depth and a (l0m) spacing will have a definite positive effect on the over all production capacity and quality of wetpaddy fields.

  • PDF

Inundation simulation in a urban drainage basin considering tidal stage effect (조위의 영향을 고려한 도심지 배수유역에서의 범람모의)

  • Kim, Dae Geun;Choi, Kyung Soon;Koh, Young Chan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.711-717
    • /
    • 2009
  • In this study, SWMM model is used to reproduce the main storm sewer system located in the Nae-Hang drainage basin of the Mokpo city and keep track of flood discharge. Given the outlet of the reaches border the coastline, this paper has taken the dual-drainage approach to perform inundation simulation, considering both the overflows and inflows at the manholes of the sewer system, and at the same time, taking the impacts of tidal stage into consideration. The following conclusions are reached in this study: First, when planning lowland sewer system alongside the coastline or the riverside, the tidal stage or flood stage need to be considered in the planning and design processes. Second, an analysis that fails to consider overflow and inundation at the manholes may overestimate inundation depth of the flooded area. In other words, in order to estimate flood discharge and flood stage in a lowland storm sewer system, it is desirable to analyze the conveyance capacity of storm sewer system and simulate overflow and inundation at the manholes at the same time.

Field Test of Mitigation Methods for Stray Currents from DC Electric Railroad(2) Rapid Potential-Controlled Rectifier (직류전기철도 전식대책 실증실험(2) 속응형 정전위 정류기)

  • Ha, Yoon-Cheol;Ha, Tae-Hyun;Bae, Jeong-Hyo;Lee, Hyun-Goo;Kim, Dae-Kyeong;Choi, Jeong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.217-219
    • /
    • 2007
  • With the wide spread of direct current(DC) electric railroads in Korea, the stray current or leakage currents from negative return rails become a pending problem to the safety of nearby underground Infrastructures. The most widely used mitigation method for this interference is the stray current drainage method, which connects the underground metallic structures to the rails with diodes (polarized drainage) or thyristor (forced drainage). This method, however, inherently possesses some drawbacks such as an increase of total leakage torrents from rails, expansion of interference zone, etc. In order to resolve these drawbacks, we developed a rapid potential-controled rectifier and applied to a depot area where stray current inference is very severe. The effect of this method was analyzed from the field tell data and we suggest this method can be an excellent alternative to the drainage-bond-based mitigation methods.

  • PDF

Study on the Treatment, Utilization and Control of the Acid Mine Drainage for Colliery - An on-site test on the Applicability of a Korean-type Prototype for Mine Drainage Purification- (석탄광의 산성갱내배수 처리.이용.제어에 관한 연구 -한국형 특수갱배수 정화장치 시작품 현지적용실험-)

  • 이춘택
    • Journal of the Korean Professional Engineers Association
    • /
    • v.19 no.4
    • /
    • pp.11-21
    • /
    • 1986
  • Mine drainage from coal mines is mostly acidic, polluted and/or contaminated, even if its quantity has increased substantially during recent days. This causes two kinds of problems arising at mining districts; one is the environmental disruption and the other is insufficient water supply for living, employee's bathing and industrial purposes. In order to mitigate the aforementioned problems, a specific equipment of Korea type for mine drainage purification has been developed and its prototype manufactured, followed by its applicability tests implemented at mine site. The results of the tests indicates that the new equipment developed is much lower than and economical compared to, other existing neutralization facilities at home and abroad in capital investment at installation stage, the consumption of neutralizing chemicals at operation stage and the requirements of installation site. Whangji area where the prototype water treatment equipment is installed has been sustaining a short supply of usable water, especially in dry seasons and supplementing about 40㎥ of water brought from a location farther than 4km in distance to meet water requirements. The prototype water treatment equipment is however considered capable of providing compressor cooling water in sufficient amount from winter season In the future.

  • PDF