• Title/Summary/Keyword: Drain Orifice

Search Result 11, Processing Time 0.02 seconds

An Analysis of the Effect of a Variant Drain Orifice Damping on an Electrohydraulic Servovalve Flapper-Nozzle Stage (전기유압 서보밸브 플랩퍼-노즐에 대한 변동 배유 오리피스의 영향 해석 1)

  • Lee, Jae-Cheon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.2 s.95
    • /
    • pp.50-59
    • /
    • 1999
  • The effect of a variant drain orifice damping on the characteristics of a servovalve flapper-nozzle stage is analyzed. Steady-state characteristics of flapper-nozzle stage and the linearized dynamics of flapper-nozzle assembly with a spool valve show that the variant drain orifice damping could improve such null performance characteristics as null pressure sensitivity and linearity of gain function. Generalized design criterion and a sufficient condition for servovalve stability are also established.

  • PDF

Performance Improvement of a Nozzle/Ball Type Servovalve with Variant Drain Orifice (변동 배유 오리피스를 갖는 노즐/볼형 서보밸브의 성능 개선)

  • Nam Y.J.;Kim K.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.255-256
    • /
    • 2006
  • This paper presents the performance improvement of a Nozzle/Ball type servovalve with variant drain orifice. First of all, the configuration of the novel servovalve is proposed. Then, the static characteristics are investigated under blocked load condition, and its dynamic characteristics are analyzed by using the linearized flow-pressure relationship. Finally, the performance at the null condition of the proposed servovalve is numerically evaluated through the comparison study with the convention at counterparts.

  • PDF

A Study on Relative Stability for Poppet Valve with Drain Orifice (드레인 오리피스를 갖는 포펫 밸브의 상대 안정도에 관한 연구)

  • Yun, S.N.;Jeong, H.H.;Seo, J.K.;Ham, Y.B.
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.12-17
    • /
    • 2010
  • The poppet valve had used every field area due to high quality of leakage property and response characteristic. But this valve still has terrible disadvantage that is self-exited vibration. This problem affects stability of total system and raises noise. The researcher tries to reduce that self-exited vibration when valve was designed. The stability discriminant is the typical study to improve the performance of the poppet valve. This paper concerns about stability discriminant that uses poppet valve with a drain orifice. At the first, the mathematical model is computed from poppet valve. After that, the limitation of stability is calculated that based on Nyquist criterion. At the final, the stability discriminant is selected in each condition and the graph that shows stability in the system is drown by dimensionless quantity.

  • PDF

A Study on the Design and the Dynamic Characteristics of Electro-Hydraulic Flow Control Servo Valve (전자유압 서보 유량제어밸브의 설계 및 동특성 향상에 관한 연구)

  • 김고도;김수태
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.2
    • /
    • pp.151-160
    • /
    • 2000
  • An experimental and theoretical analysis for the improvement of dynamic characteristics and design of electro-hydraulic flow control servo valve are performed. The theoretical results are compared with the experimental step responses, and the important design parameters of an electro-hydraulic flow control servo valve are derived by using the simulation program. Simulation parameters of nozzle jet coefficient and orifice and spool valve discharge coefficient are given through experiment. The theoretical and experimental step response curves show that the valve gain depends on the fixed orifice and nozzle $ratio(R_on)$ and is maximum at $R_on=1.$ And drain orifice in the flapper - nozzle return line creates a small back pressure, which improves the performance fur the valve.

  • PDF

A Study on Characteristics of Flow Control Servo Valve with no Drain Orifice (드레인 오리피스가 없는 유랑제어 서보밸브의 특성에 관한 연구)

  • Yun, So-Nam;Gang, Bo-Sik;Seong, Baek-Ju;Kim, Hyeong-Ui
    • 연구논문집
    • /
    • s.26
    • /
    • pp.85-94
    • /
    • 1996
  • The purpose of this study is to bring out the optimal design factors which effect on dynamic characteristics in the design of proportional flow control valve with high response characteristics, and to verify the validity of the design factors. In this study, force feedback type flow control valve with nozzle-flapper is studied. And, the influences which fixed orifice, nozzle diameter, and maximum displacement between nozzle and flapper effect on dynamic characteristics are analyzed. We have done simulations using the optimal design factors and simulink(Matlab) as a simulation tool, and verified the validity of our simulations by means of comparison our simulation results with an experimental results of another similar valve.

  • PDF

Flow characteristics validation around drain hole of fan module in refrigerator (냉장고 팬 모듈의 물빠짐 구멍 주변 유동 특성 검증)

  • Jinxing, Fan;Suhwan, Lee;Heerim, Seo;Dongwoo, Kim;Eunseop, Yeom
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.102-108
    • /
    • 2022
  • In the fan module of the intercooling refrigerator, a drain hole structure was designed for stable drainage of defrost water. However, the airflow passing through the drain hole can disturb flow features around the evaporator. Since this backflow leads to an increase in flow loss, the accurate experimental and numerical analyses are important to understand the flow characteristics around the fan module. Considering the complex geometry around the fan module, three different turbulence models (Standard k-ε model, SST k-ω model, Reynolds stress model) were used in computational fluid dynamics (CFD) analysis. According to the quantitative and qualitative comparison results, the Standard k-ε model was most suitable for the research object. High-accuracy results well match with the experiment result and overcome the limitation of the experiment setup. The method used in this study can be applied to a similar research object with an orifice outflow driven by a rotating blade.

A Study on the As-Built Leakage Diagnosis of Main Steam Drain Valves for Nuclear Power Plants by Multi-measuring Technique (다중계측기법을 이용한 원전 주증기배수밸브의 현상태 누설진단에 관한 연구)

  • Kim, Sung-Young;Kim, Young-Bum;Kim, Do-Hyeong;Lee, Sang-Gok
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2606-2611
    • /
    • 2008
  • The high energy fluid leakage from the high temperature and high differential pressure drop system of NPPs (Nuclear Power Plants) decreases efficiency and consequently leads to considerable economic loss due to less power production. Also, the leakage possibly damages critical parts of components such as valve and trim with the effect of cavitation, flashing, and erosion, etc. and deteriorates its performance. Thus, in this study, we diagnosed the as-is leakage for four (4) main steam drain valves and two (2) steam traps of Yonggwang 1,2 units during normal operation by using multi-measuring technique and observed the occurrence of fine leakage. In the course of measuring fluid leakage, the sign of fine leakage is estimated to be the leakage from orifice. By converting the leakage to energy loss, it is equivalent to the amount of several hundred thousand won per each unit, which supports the basis for the justification of fine leakage.

  • PDF

A Study On Characteristics of Nozzle/Flapper Type Flow Control Servo Valve (노즐/플래퍼형 유량제어 서보밸브의 특성에 관한 연구)

  • 윤소남;강보식;성백주;김형의
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.1
    • /
    • pp.54-62
    • /
    • 2000
  • The purpose of this study is to bring out the optimal design factors which effect on dynamic characteristics in the design of flow control servo valve with high response characteristics, and to verify the validity of the design factors. In this study, force feedback type flow control valve with nozzle/flapper and with no drain is studied. And, the effect of the parameters, such as fixed orifice, nozzle diameter, and maximum displacement between nozzle and flapper are analyzed. We have done simulations using the optimal design factors and simulink(Matlab) as a simulation tool, and verified the validity of our simulations by means of comparison our simulation results with an experimental results of another similar valve.

  • PDF

Cor triatriatum associated with partial anomalous pulmonary venous drainage: one case report (폐정맥 환류이상을 동반한 삼중방심 치험 1)

  • Kim, Yeong-Ho;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.381-388
    • /
    • 1984
  • Cor triatriatum is rare congenital cardiac anomaly first described by Church in 1868. The anomaly consists of an abnormal partitioning of the left atrium by a fibromuscular membrane that divides the atrium into an upper chamber, which receives the pulmonary veins, and a lower chamber, which contains the atrial appendage and the mitral valve. The upper and lower chambers communicate through a stenotic fenestration in the membrane, which has the hemodynamic consequence of pulmonary venous obstruction. Recently we experienced cot triatriatum associated with partial anomalous pulmonary drainage to right atrium. The upper chamber was connected to right atrium through a sinus venous type of ASD and received left superior and both inferior pulmonary vein, whereas the lower chamber so called true left atrium communicated with right atrium through foramen ovale type of ASD, left atrial appendage and mitral orifice. And the anomalous membrane has no fenestrations which permit blood flow. The operation was made right atrial approach under the CPB. We excised completely the anomalous septum and reconstructed atrial septal defect with pericardial patch to drain the right upper pulmonary vein to the left atrium. The postoperative course has been good during follow up.

  • PDF

Case Report: Intraoperative Management Using Inferior Based Rotation Flap of Sternocleidomastoid Muscle for Chyle Fistula (흉쇄유돌근의 회전피판을 이용한 수술 중 발생한 유미루의 치료 1예)

  • Kim, Seo Bin;Lee, Hyoung Shin;Lee, Kang Dae;Kim, Sung Won
    • Korean Journal of Head & Neck Oncology
    • /
    • v.32 no.2
    • /
    • pp.79-83
    • /
    • 2016
  • Chyle fistula is one of the complications of neck dissections. Although immediate surgical repair seems to be the best choice when chyle leakage is observed during the operation, some operators can be embarrassed when chyle leakage is heavy and not controlled during surgery. In this case, chyle leakage was occurred after extensive resection of lymph nodes in left level IV, and was not controlled in any way. The clavicular head of sternocleidomastoid muscle was dissected and inferior-based muscular flap was rotated to cover the suspected region of fistula orifice. Amount of drainage was checked less than 20 ml per day in the following days, and drain tube was taken out on the 3rd postoperative days. We present the technique using the inferior based sternocleidomastoid muscle flap for intraoperative management of chyle leakage not easily controlled.