• Title/Summary/Keyword: Downlight

Search Result 12, Processing Time 0.015 seconds

Thermal Analysis of a Radial Heat Sink with Radiation and Natural Convection (복사 열전달을 고려한 자연대류 원형 히트싱크 열전달 해석)

  • Yu, Seung-Hwan;Jang, Dae-Seok;Lee, Kwan-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.385-390
    • /
    • 2012
  • A radial heat sink, adopted to LED(light emitting diode) downlight, was optimized. Discrete transfer radiation model (DTRM) was used to calculate radiation heat transfer, and numerical model was verified with experimental results. The effects of number of fin, long fin length and middle fin length on overall thermal resistance and radiation heat transfer were analyzed. As the emissivity increased, thermal resistance decreased due to the increment of radiation heat transfer. The radial heat sink was optimized and optimum number of long fins is 19~28, optimum length of long fin is about half of radius of heat fink and optimum fin ratio is 0.4~0.7.

Performance Analysis of Heat Sink for LED Downlight Using Lumped Parameter Model (집중변수모델을 이용한 LED조명등 방열기구의 성능분석)

  • Kim, Euikwang;Jo, Youngchul;Yi, Seungshin;An, Younghoon
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.64-72
    • /
    • 2017
  • The performance analysis of the 70 W class LED lighting system suitable for the Middle East environment was performed using the lumped parameter model. The LED light is composed of a heating substrate, a heat pipe, and a heat sink. We divided the LED lights into four objects and applied energy equilibrium to each of them to establish four lumped nonlinear differential equations. The solution of the simultaneous equations was obtained by the Runge-Kutta method. Convective heat transfer coefficients of the lumped model were obtained by multidimensional CFD analysis. As a result of comparison with experiment, it was found that the heating substrate had an error of $1.5^{\circ}C$ and the upper heat sink had an error of $1.8^{\circ}C$ and the relative error was about 0.6 %. Using this model, temperature distribution analysis was performed for normal operating conditions with an ambient temperature of $55^{\circ}C$, with sunlight only, with abnormal operating conditions with sunlight, and without an upper heat sink.