• Title/Summary/Keyword: Down-hole test

Search Result 34, Processing Time 0.025 seconds

Application and Analysis of Field Test and Geophysical Exploration for Dynamic Material Properties of Rockfill Dam (사력댐 동적물성 추정을 위한 현장조사기법 적용 및 분석)

  • Lee, Jong-Wook;Kim, Ki-Young;Jeon, Je-Sung;Cho, Sung-Eun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.352-359
    • /
    • 2005
  • In this study, seismic refraction survey and MASW at dam crest and down-hole test and cross hole test in the boring holes located in dam crest through the core are performed to fin out dynamic material properties, are needed to evaluate dynamic safety of rockfill dam using dynamic analysis method. From the field test and geophysical exploration, applied such as above, p-wave and s-wave velocity profile of each layer of dam body. Dynamic material properties, such as elastic modulus, shear modulus, poissong's ration, are obtained from p-wave and s-wave velocity profile and density profile from formation density logging test.

  • PDF

Study on Comparison of Methods for Estimation of Shear Wave Velocity in Core Zone of Existing Dam (기존 댐 코어죤의 전단파속도 산정기법 비교 연구)

  • Ha, Ik-Soo;Oh, Byung-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.10
    • /
    • pp.33-43
    • /
    • 2008
  • In this study, for the purpose of evaluating the shear wave velocity in core zone, cross-hole test, down-hole test, MASW (Multi-channel Analysis of Surface Wave), and seismic reflection survey were carried out on the crest of the existing 'Y' dam. The results of field tests were compared one another. Furthermore, the field test results were compared with the result by the Sawada's empirical recommendation method. The purpose of this study is to compare the results of four kinds of field tests for evaluation of shear wave velocity in core zone of existing dam, to verify applicability of the empirical method which was recommended by Sawada and Takahashi, and to recommend a reasonable method for evaluation of shear wave velocity which is needed to evaluate tile maximum shear modulus of core zone. From the results of four kinds of field tests such as cross-hole test, down-hole test, MASW, and seismic reflection survey, it was found that the shear wave velocity distributions were similar within 18 m in depth and the results obtained by MASW and seismic reflection survey were almost the same by 30 m in depth. For evaluation of shear wave velocity in core zone of the existing dam, in consideration that it is not easy to bore the hole ill the core zone of existing dam, surface surveys such as MASW and seismic reflection method are recommended as realistic methods. On condition that it is impossible to conduct the field test and it is preliminary investigation, it is recommended that Sawada's low bound empirical equation be used.

A Pilot Study of Stiffness Mesurements for Tunnel-Face Materials Using In-hole Seismic Method (인홀 시험을 이용한 터널 막장의 암반강성 측정에 대한 적용성 연구)

  • Mok, Young-Jin;Kim, Young-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.445-456
    • /
    • 2005
  • The research concentrates on improving the in-hole seismic probe, which has been developed in past five years, to be used in stiffness measurements of tunnel-face materials. The probe was down-sized to be fit in 45-mm diameter holes(or BX) drilled by a jumbo-drill, which is used to drill holes to install explosives for tunneling. Also trigger system was improved by using a down-speeding motor for operating convenience and air packing system was replaced with a set of plate-springs to eliminate supply of compressed air. These modifications are to adjust the probe for the unfavourable environment inside of tunnels and to test without any further drilling cost. The probe and testing procedure were successfully adopted with horizontal holes drilled by a jumbo-drill at a tunnel-face to evaluate the stiffness of rock mass. The measured shear wave velocities can be used to estimate deformation properties of rock mass for tunnel analyses.

  • PDF

An Elemental Study for construction elevation of a Underground Columns in Top-Down construction Method (TOP-DOWN공법에 의한 지하기둥의 시공성 향상을 위한 기초적 연구)

  • 임형일;박희곤;백민수;조상영;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1059-1064
    • /
    • 2001
  • This study is about accurate steel column position method in the Top down method's delicate part. When the concrete is placing, it is required that complementary measures to the transformation due to concrete pressure, column buckling, the trouble due to bar net inserting and so on. To solve the problem of exist method, the concrete is placed at the bottom of excavated hole in advance. then, the steel column is inserted into the excavated hole. With a new method try, the problem due to placing pressure and others is could be prevented. In this study, the concrete is examined with test-slump, slump flow, and compressive strength to do quantitative analysis of concrete. The factors of the experiment is plasticizer, retarder addition rate, fly ash substitution rate to cement. Considering of the new method try, the retarder added concrete properties-fluidity, viscosity, strength-is investigated as time lapsing.

  • PDF

Disturbance Effects of Field $V_S$ Probe (현장 전단파 속도 프로브의 교란효과)

  • Yoon, Hyung-Koo;Lee, Chang-Ho;Lee, Woo-Jin;Lee, Jong-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.605-612
    • /
    • 2008
  • The shear wave velocity ($V_s$) has been commonly used to evaluate the dynamic properties of soil. The field $V_s$ probe (FVP) was already developed to assess the shear stiffness of a soft clay. The objective of this study is to investigate the disturbance effects of the FVP due to the penetration. The laboratory tests are conducted in a large-scale consolidometer (calibration chamber). The reconstituted clay is mixed at the water content of 110% using a slurry mixer. The FVP and down-hole test are carried out every 1cm interval to compare the data. In addition, two square rods with transducers are also implemented to get the reference value. The shear waves evaluated by the FVP, dow-hole tests, and reference rods are closely matched. This study suggests that the disturbance effect of the FVP due to the penetration into the soft clay soils is small enough and the $V_s$ evaluated by the FVP reflects well the in-situ characteristics. Furthermore, the combination of the FVP and down-hole test shows the possibility of hybrid equipment.

  • PDF

Stress Change Varying with Hole Place of RC Column (유공위치 변경에 따른 RC기둥의 내력변화에 관한 실험적 연구)

  • Son, Ki-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.70-79
    • /
    • 2006
  • many plumbing system are needed in the ceiling of the building as it becomes advanced more and more. This leads to make effective space between ceiling level and slab less. Also, piping system is not suitably arranged and operated if it is bent around the columns which they are a lot. But this system can be more effective if it passes through the columns directly. Most people think that those columns should not be damaged with such as holes. But actually this is existed in a hotel building in switzerland. This study is to fing out how much capacity the columns become damaged and low using model size of $20cm{\times}30cm$ rectangular section, and 160cm long, in the structural test. it's compressive strength is focused on $240kg/cm^{2}$ design strength, commonly used in korea. Compressive test for them was done at Hanyang University using UTM one thousand tone(1000t) capacity. Variable numbers for the study are one hole of dia 3cm with distance 20cm or 40cm, two holes of dia 3cm with 20cm and 40cm distance, one hole of dia 5cm with distance 20cm and 40cm, two holes of dia 5cm with 20cm and 40cm distance, me eccentric hole with 20cm and 40cm distance, Normal(without hole). two test specimens of each variable are made for the test. ED5H20 capacity was 16.7% decreased, compared to normal one. While ED5H40 distant 40cm from the end of column top showed 19.5% capacity decrease, compared to normal one. Strain of ED5H20 diameter 5cm, in distance of 20cm form the top of the column was less 5% than the one of diameter 3cm. Finally, conclusions are that in case of hole diameter 3cm, located at 20cm from the end of the column top, capacity was decreased down to 3, percent only compared to the same diameter hole with 20cm distant from the end of it.

Comparison of S-wave Yelocity Profiles Obtained by Down-hole Seismic Survey, MASW and SCPT with a Drilling Log in Unconsolidated Sediments (비고결 퇴적물에서 다운홀 탄성파 탐사, MASW, SCPT로 구한 횡과 속도 단면과 시추결과 비교 연구)

  • Kim, Hyun-Do;Kim, Jin-Hoo
    • Journal of the Korean earth science society
    • /
    • v.25 no.4
    • /
    • pp.270-276
    • /
    • 2004
  • Multi-channel Analysis of Surface Waves (MASW) and Seismic Cone Penetration Test (SCPT) have been recently developed to obtain S-wave velocity profiles which were conventionally investigated by a down-hole seismic survey. For unconsolidated sedimentary sites, we studied these three methods, and compared the results with a drilling log. All the methods showed that the changes in the S-wave velocities were consistent with the changes in the sedimentary facies. In addition, the SCPT was most sensitive to changes in sedimentary facies among the three profiles. The results of the SCPT showed that there exists a low velocity zone, which is mainly composed of clayey sand, at the depth of 8${\sim}$12m in the sediments.

Modelling and Test of Down-the-Hole Hammer (다운더홀(DTH) 해머의 모델링 및 실험)

  • Hwang, U.K.
    • Journal of Drive and Control
    • /
    • v.12 no.2
    • /
    • pp.34-38
    • /
    • 2015
  • Research and development of mineral resource related products has progressed with the increased need to develop mineral resources. The DTH hammer is one a resultant product. However, due to particular work conditions of underground drilling, it is difficult to obtain direct data on the DTH Hammer. A DTH drill rig requires a lot of money and time for actual testing. This thesis aimed to resolve this problem by using CAE. First, the structure of the DTH hammer and the movement was analyzed. Next, a standard model based on simulation was proposed and then experimentation and comparison verification was conducted. In addition, the verified models were applied to products of various sizes, and the models used in simulation were compared by conducting field tests.

BEHAVIOR OF LIQUID LPG SPRAY INJECTING FROM A SINGLE HOLE NOZZLE

  • PARK K.
    • International Journal of Automotive Technology
    • /
    • v.6 no.3
    • /
    • pp.215-219
    • /
    • 2005
  • Liquefied petroleum gas (LPG) has been used as motor fuel due to its low emissions and low cost. A liquid direct injection system into a cylinder was suggested as a next generation system to maximize a fuel economy as well as a power. This study addresses the analysis of the LPG spray injecting from single hole injector. Two different test conditions are given, which are a fully developed spray case with various injection pressures and a developing spray case with ambient pressure variation. The LPG spray photographs are compared with the sprays of gasoline and diesel fuel at the same conditions, and the spray angles and penetration lengths are also compared, and then the spray behavior is analyzed. The LPG spray photos show that the dispersion characteristic depends very sensitively on the ambient pressure soon after injection. The spray angle is very wide in a low ambient pressure condition until the saturated pressure, but the angle is quickly reduced at the condition over the pressure. However, the down stream of the LPG spray shows much wider dispersion and less penetration than those of gasoline and diesel sprays regardless ambient pressure condition.

A Validation Study on the Reinforcement Effect of Reservoir Grouting by Surface Wave Survey (표면파탐사를 이용한 저수지 제체 그라우팅 보강효과 검증 연구)

  • Bae, Hyungseop;Lee, Yeong-Dong;Won, Kyoung-Sik
    • The Journal of Engineering Geology
    • /
    • v.28 no.2
    • /
    • pp.297-312
    • /
    • 2018
  • In order to assess the safety diagnosis and grouting reinforcement effect of old reservoir facility, local governments and public offices mainly use electrical resistivity survey. However, electrical resistivity survey is a qualitative evaluation that varies the resistivity value by various exploration conditions. It is also difficult to grasp the stiffness change directly related to the stability of reservoir, thus an electrical resistivity survey is not applicable to continuous stability monitoring after grouting. The purpose of this study is to investigate and validate the quantitative evaluation of reinforcement effect of reservoir with cement grouting through shear velocity (Vs), which is closely related to the stiffness (${\mu}$) of the ground. This study was carried out on two reservoir facilities. The reinforcement effect was evaluated by comparing the permeability test, standard penetration test, down-hole test and MASW(Multi-channel Analysis of Surface wave) survey before and after cement grouting. Shear wave velocity changes before and after grouting were analyzed by phase velocity difference and inversion analysis, respectively, and the reliability of the analytical results was evaluated by comparing with field test results. Shear wave velocity increases to 5~10% in case of the D levee, and 10~20% in the levee of H reservoir. These results are showed similar pattern to the field test results.