• 제목/요약/키워드: Double resonance

검색결과 250건 처리시간 0.036초

A Wide-band Multi-layer Antenna Design using Double Resonance (이중공진을 사용한 적층기판용 광대역 안테나 설계)

  • Lee, Kook-Joo;Zhang, Mei-Shan;Lee, Jung-Aun;Han, Myeong-Woo;Kim, Moon-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제60권2호
    • /
    • pp.431-434
    • /
    • 2011
  • In this paper, bandwidth enhanced design of dielectric resonator antenna fabricated in multi-layer substrate is introduced. The proposed dielectric resonator antenna is operating with fundamental TE101 mode and higher-order TM111 mode. Each resonance frequency is dependent on resonator dimensions. As increasing the height of radiating aperture, the higher-order TM111 mode resonance frequency approach the fundamental TE101 mode resonance frequency and the antenna bandwidth increase by double resonance. Three different aperture height size antennas that operated at 7GHz are fabricated in FR4 multi-layer substrate. Measured 10 dB matching bandwidth is 8 percent for single resonace antenna and 18 percent for double resonance antenna.

Magnetic Resonance Imaging with Intermolecular Double Quantum Coherences

  • Ahn, Sang-Doo
    • Journal of the Korean Magnetic Resonance Society
    • /
    • 제8권2호
    • /
    • pp.108-114
    • /
    • 2004
  • Recently a new method for magnetic resonance imaging based on the detection of relatively strong signal from intermolecular multiple quantum coherences (iMQCs) is reported. Such a signal would not be observable in the conventional framework of magnetic resonance; it originates in long-range dipolar couplings that are traditionally ignored. In this paper, we present the results of experimental studies to assess the feasibility of intermolecular double quantum coherences (iDQCs) imaging in humans. We show that the iDQC images are readily observable at 4T and that they do indeed provide different contrast than appears in conventional images.

  • PDF

Double Resonance Characteristics of Crossed Planar Monopole Antenna by L-Shaped Slit (L형 슬릿에 의한 십자형 평판 모노폴 안테나의 이중공진 특성)

  • Shim, Jae-Ruen
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제8권3호
    • /
    • pp.508-512
    • /
    • 2007
  • In this paper, a novel wideband crossed planar monopole antenna with the double resonance characteristics is proposed. The proposed monopole antenna consists of a wideband crossed planar monopole antenna and L-shaped slits. In order to generate double resonance characteristics on the proposed monopole antenna, the length of L-shaped slit on the antenna surface is obtained from the quarter-wavelength of the second resonance frequency The double resonance characteristics of the proposed antenna can be easily designed by the control of length of L shaped slit at an interesting frequency. The proposed antenna having an omnidirectional radiation pattern and a high gain over the double resonance frequency bands, respectively, is suitable for mobile multiband antenna.

  • PDF

Double Resonance Spectra Involving Torsional Excited Levels and CO Stretch Band Transitions of $CD_3OH$

  • Choi, Sung-Eul
    • Korean Journal of Optics and Photonics
    • /
    • 제6권2호
    • /
    • pp.165-171
    • /
    • 1995
  • Infrared-Radio frequency double resonance (IRRFDR) and Infrared-Microwave double resonance (IRMWDR) spectroscopy have been used to probe a level of A symmetry for $CD_{3}$OH. Double resonance spectra of $CD_{3}$OH have been investigated over the range of 940 to 1020 $cm ^{-1}$ . Twenty K-type doublet transitions have been observed in both the radio frequency region, which covers 50 MHz to 1 GHz, and the microwave region, which covers 8 GHz to 12 GHz. The results propose new assignments of infrared (IR) absorption transitions and far-infrared (FIR) laser emission lines. These involve torsional excited levels and CO stretch states. Measurements of the A state splitting have permitted the determination of the asymmetry splitting parameters $S^{o}$(n, K) and $^{co}$ (n, K) for (n, K)=(0.3) and (1.3)

  • PDF

Mode Identification in the Design of Wideband Cylindrical Monopole Antenna

  • Chun, Joong-Chang;Kim, Sang-Youl;Jeung, Deuk-Soo
    • Journal of information and communication convergence engineering
    • /
    • 제7권3호
    • /
    • pp.263-267
    • /
    • 2009
  • Cylindrical monopole antenna is one of most promising candidates for multi-band applications such as PCS, WLAN, DMB, and UWB wireless services. In this research, we demonstrate that there exist two types of current distributions according to the exciting frequency in a double band cylindrical monopole antenna, in which double resonance is achieved by adjusting the coupling structure of the antenna base. The operating modes of current distributions are identified from CST software simulations, the standing wave mode in a lower band and the traveling wave mode in a higher band. Also it is noticed that the mode behavior is quite similar to a helical antenna, a standing-wave (resonance) mode and a traveling-wave (non-resonance) mode according to the electrical dimensions of antenna. The effective ranges for operating modes and design formulas of the double band antenna are derived from simulation and measured results.

A Double Bi-Quad Filter with Wide-Band Resonance Suppression for Servo Systems

  • Luo, Xin;Shen, Anwen;Mao, Renchao
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1409-1420
    • /
    • 2015
  • In this paper, an algorithm using two bi-quad filters to suppress the wide-band resonance for PMSM servo systems is proposed. This algorithm is based on the double bi-quad filters structure, so it is named, "double bi-quad filter." The conventional single bi-quad filter method cannot suppress unexpected mechanical terms, which may lead to oscillations on the load side. A double bi-quad filter structure, which can cancel the effects of compliant coupling and suppress wide-band resonance, is realized by inserting a virtual filter after the motor speed output. In practical implementation, the proposed control structure is composed of two bi-quad filters on both the forward and feedback paths of the speed control loop. Both of them collectively complete the wide-band resonance suppression, and the filter on the feedback path can solve the oscillation on the load side. Meanwhile, with this approach, in certain cases, the servo system can be more robust than with the single bi-quad filter method. A step by step design procedure is provided for the proposed algorithm. Finally, its advantages are verified by theoretical analysis and experimental results.

Displaced Double-Layered Lateral Meniscus That Mimicked the Bucket-Handle Tear: a Case Report

  • Kwak, Min Jee;Kim, Sun Ki;Kim, Ki Jun;Lee, Bum-Sik;Kang, Jun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권3호
    • /
    • pp.191-195
    • /
    • 2016
  • Among the various types of congenital meniscal anomalies, the double-layered lateral meniscus is extremely rare. The double-layered meniscus consists of both the upper additional and the lower normal meniscus. As the upper additional meniscus is mobile, it can be easily displaced, while the lower lateral meniscus is usually normal in shape and volume. A 42-year-old woman suffering from pain and locking of her left knee underwent Magnetic resonance imaging (MRI) examination and an arthroscopic surgery. A rare meniscal abnormality was seen in her left knee, which presented as a double-layered lateral meniscus with displacement. It was remarkable that the upper additional meniscus was displaced over the intercondylar eminence of the tibia and it mimicked a bucket-handle tear. Even though it is rare, it is necessary to consider the possibility of displaced double-layered meniscus in the differential diagnosis of a bucket-handle tear. Here, we report the MRI and arthroscopic findings of a displaced double-layered lateral meniscus, which was similar to the bucket-handle tear.

Electron Spin Resonance and Electron Nuclear Double Resonance Studies on the Photoinduced Charge Separation of N-Methylphenothiazine in Phenyltriethoxysilane, Vinyltriethoxysilane and Methyltriethoxysilane Gel Matrices

  • Kang, Young-Soo;Park, Chan-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • 제4권2호
    • /
    • pp.91-102
    • /
    • 2000
  • The photoproduced cation radical of N-methylphenothiazine doped in the different kind of matrices of phenyltriethoxysilane (PhiTEOS), vinyltriethoxysilane (VTEOS), and methyloiethoxysilane (METOS) was comparatively studied with electron spin resonance (ESR) and electron nuclear double resonance (ENDOR). The photoinduced charge separation efficiency was determined by integration of ESR spectra which correspond to the amount of photoproduced cation radical in the matrices. This was correlatively studied with the polarity and pore size of the gel matrices. The polarity of the matrices was comparatively determined by measuring λ$\sub$max/ values of PC$_1$ in the different matrices. The relative pore size among the matrices was determined by measuring relative proton matrix ENDOR line widths of the photoproduced cation radical of PCI. The decay kinetic constants of the cation radical of PCI in the different matrices was relatively studied with fitting the biexponential decay curves after exposure into the ambient condition. This is correlatively interpreted with the polarity and pore size of the matrices.

  • PDF

Evaluation of Knee Joint after Double-Bundle ACL Reconstruction with Three-Dimensional Isotropic MRI

  • Jung, Min ju;Jeong, Yu Mi;Lee, Beom Goo;Sim, Jae Ang;Choi, Hye-Young;Kim, Jeong Ho;Lee, Sheen-Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권2호
    • /
    • pp.95-104
    • /
    • 2016
  • Purpose: To evaluate the knee joint after double-bundle anterior cruciate ligament (ACL) reconstruction with three-dimensional (3D) isotropic magnetic resonance (MR) image, and to directly compare the ACL graft findings on 3D MR with the clinical results. Materials and Methods: From January 2009 to December 2014, we retrospectively reviewed MRIs of 39 patients who had reconstructed ACL with double bundle technique. The subjects were examined using 3D isotropic proton-density sequence and routine two-dimensional (2D) sequence on 3.0T scanner. The MR images were qualitatively evaluated for the intraarticular curvature, graft tear, bony impingement, intraosseous tunnel cyst, and synovitis of anteromedial and posterolateral bundles (AMB, PLB). In addition anterior tibial translation, PCL angle, PCL ratio were quantitatively measured. KT arthrometric values were reviewed for anterior tibial translation as positive or negative. The second look arthroscopy results including tear and laxity were reviewed. Results: Significant correlations were found between an AMB tear on 3D-isotropic proton density MR images and arthroscopic proven AMB tear or laxity (P < 0.05). Also, a significant correlation was observed between increased PCL ratio on 3D isotropic MRI and the arthroscopic findings such as tear, laxities of grafts (P < 0.05). KT arthrometric results were found to be significantly correlated with AMB tears (P < 0.05) and tibial tunnel cysts (P < 0.05). Conclusion: An AMB tear on 3D-isotropic MRI was correlated with arthroscopic results qualitatively and quantitatively. 3D isotropic MRI findings can aid the evaluation of ACL grafts after double bundle reconstruction.