• Title/Summary/Keyword: Double plate

Search Result 357, Processing Time 0.031 seconds

Development of a Torsion Joint Yoke for Motor-Driven Power Steering System Using a Double-Action Extrusion Process (더블-액션 압출공정을 적용한 전동조향장치용 토션조인트 요크 개발)

  • Kim, H.M.;Kim, Y.K.;Park, Y.B.
    • Transactions of Materials Processing
    • /
    • v.21 no.8
    • /
    • pp.473-478
    • /
    • 2012
  • The yoke, a component of conventional motor-driven power steering system, often contains welding defects from its manufacturing process. To eliminate these defects, the precision cold forging process has been tried. In this study, the double-action complex forging has been used to manufacture a torsion joint yoke. The backward extrusion proved faster than the forward extrusion in forging of the product. The double-action complex forging process utilized an upper die composed of a punch, a punch guide, a disc spring and a coil spring. The forged material pushes up the punch guide, and then the disc spring and the coil spring balances the backward extrusion force. Consequently, the flow of material was essentially in the forward direction, resulting in a successful forging operation. The forging load of Al 6061-T6 was higher than that of the automotive structural hot rolled plate.

The Effectiveness of Furlow's Double Opposing Z-plasty for Treatment of Velopharyngeal Insufficiency (비인강폐쇄기능부전의 치료에 있어서 Furlow 이중 Z-성형술의 효과)

  • Kim, Soo-Ho;Kim, Eu-Gene;Park, Hyong-Wook;Cheon, Kang-Yong;Hwang, Soon-Jung
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.15 no.2
    • /
    • pp.97-108
    • /
    • 2012
  • Velopharyngeal insufficiency (VPI) is improper closure of velopharynx during the phonation and swallowing due to various causes, especially appeared in cleft palate patients. The several surgical techniques and speech therapy can be considered in treatment of VPI. The surgical techniques such as Furlow's double opposing Z-plasty, pharyngeal flap, push-back palatoplasty, etc. have been widely used when the speech therapy is not so much effective. However, there is considerable variability in the methods for evaluation and in success criteria making difficult to compare among surgical techniques. This article reviewed the recent articles about comparing the surgical techniques in treatment of VPI. Although there is no significant difference in speech assessment by speech pathologist, Furlow's double opposing Z-plasty is a useful technique especially diminishing hypernasality and nasal emission.

  • PDF

Development of a 9as-liquid two-phase flowmeter using double orifice plates (2중판 오리피스를 이용한 기액 2상유량계의 개발)

  • 이상천;이상무;남상철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.619-629
    • /
    • 1998
  • An experimental work was conducted to investigate a feasibility of simultaneous measurement of gas-liquid two-phase flowrates with double orifice plates using air and water. The tests were carried out under the atmospheric pressure and at the ambient temperature using two different tube sizes. Qualities of an air-water flow in the present study have values less than 0.1 and thus the mixed flow showed bubbly, plug, slug flow regimes. The probability density function (PDF) and the power spectral density function (PSDF) of the instantaneous pressure drop traces for the flow regimes were obtained. It is found that some distinctive features exist in the distribution of these functions, depending upon the two-phase flow pattern. The time-averaged value of the instantaneous pressure drop increases with increasing gas and liquid flowrates, showing a single-valued function for the total mass flowrate and the quality. It is also found that the two-phase discharge coefficient exhibits a consistent trend for variation of dimensionless parameters such as the superficial velocity ratio and the gas Reynolds number. The results indicate that simultaneous measurement of two-phase flowrate may be possible based upon a statistical analysis of the instantaneous pressure drop curves monitored using double orifice plates.

  • PDF

Nonlinear Analysis of Slender Double Skin Composite Walls Subjected to Cyclic Loading (주기하중을 받는 세장한 이중강판합성벽의 비선형해석)

  • Eom, Tae Sung;Park, Hong Gun
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.505-517
    • /
    • 2008
  • A numerical analysis method was studied to predict the nonlinear behavior of slender double skin composite walls. For convenience in numerical analysis, the model for the double skin composite wall was developed as a macroscopic model that can predict nonlinear behavior with relatively simplified models. For the wall showing flexure-dominant behavior, a multiple layer model was used. Each layer was modeled with composite elements of concrete and steel plate. An X-type truss model was used for coupling beams showing shear-dominant behavior. To describe the cyclic behavior of concrete and steel elements, simplified cyclic models for the materials were proposed. The proposed analysis model was applied to isolated walls and coupled walls with rectangular or T-shaped cross-sections. The analytical results were compared with existing test results.

Biomechanical Characteristic on Lower Extremity with or without Chronic Ankle Instability during Double Leg Drop Landing (양발 드롭랜딩 시 만성적인 발목 불안정성 유무에 따른 하지주요관절의 역학적 특성)

  • Jeon, Kyoungkyu;Park, Jinhee
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.2
    • /
    • pp.113-118
    • /
    • 2021
  • Objective: The purpose of this study was to investigate differences of landing strategy between people with or without chronic ankle instability (CAI) during double-leg drop landing. Method: 34 male adults participated in this study (CAI = 16, Normal = 18). Participants performed double-leg drop landing task on a 30 cm height and 20 cm horizontal distance away from the force plate. Lower Extremities Kinetic and Kinematic data were obtained using 8 motion capture cameras and 2 force plates and loading rate was calculated. Independent samples t-test were used to identify differences between groups. Results: Compared with normal group, CAI group exhibits significantly less hip internal rotation angle (CAI = 1.52±8.12, Normal = 10.63±8.44, p = 0.003), greater knee valgus angle (CAI = -6.78±5.03, Normal = -12.38 ±6.78, p = 0.011), greater ankle eversion moment (CAI = 0.0001±0.02, Normal = -0.03±0.05, p = 0.043), greater loading Rate (CAI = 32.65±15.52, Normal = 18.43±10.87, p = 0.003) on their affected limb during maximum vertical Ground Reaction Force moment. Conclusion: Our results demonstrated that CAI group exhibits compensatory movement to avoid ankle inversion during double-leg drop landing compared with normal group. Further study about how changed kinetic and kinematic affect shock absorption ability and injury risk in participants with CAI is needed.

An Experimental Study of Buckling Behavior in Built-up Compression Member with Unsymmetric Connectors II - Effect of Type of Connection Members - (비대칭 연결재를 갖는 조립식 압축부재의 좌굴 거동에 관한 실험 연구 II - 연결재 종류의 영향 -)

  • Kang, Sanghoon;Han, Manyop;Cho, Byeongdu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4A
    • /
    • pp.217-225
    • /
    • 2012
  • Structural behavior of built-up compression members with unsymmetric connectors under buckling status has been studied through these experiments. When the distance between adjacent H-300 beams of built-up compression member is 2 m in length, and the H-300 beams are lengthened up to 30 m in length with three-10 m-H-beams by bolts and double arrayed, three specimen having each connector plate, single channel, double channel are experimented for evaluating buckling loads. The buckling loads from the experiments are compared with buckling loads of structural analysis using FEM and buckling loads of Timoshenko Eq. in order to figure out how the connectors' type affects on longitudinal and lateral displacements, also strain of the built-up compression members as well. The result from the experiments show that the buckling loads 4.2% decreases in double channel connectors and 36.6% decreases in single channel connectors than plate connectors.

Performance Analysis of Double-Glazed Flat Plate Solar Collector with Cu-based Solar Thermal Absorber Surfaces

  • Lee, Jeong-Heon;Jeong, Da-Sol;Nam, Yeong-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.157.1-157.1
    • /
    • 2016
  • In this work, we experimentally investigated the solar absorption performance of Cu-based scalable nanostructured surfaces and compared their performance with the conventional TiNOX. We fabricated Cu-based nanostructured surfaces with a controlled chemical oxidation process applicable to a large area or complex geometry. We optimized the process parameters including the chemical compounds, dipping time and process temperature. We conducted both lab-scale and outdoor experiments to characterize the conversion efficiency of each absorber surfaces with single and double glazing setup. Lab-scale experiment was conducted with $50mm{\times}50mm$ absorber sample with 1-sun condition (1kW/m2) using a solar simulator (PEC-L01) with measuring the temperature at the absorber plate, cover glass, air gap and ambient. From the lab-scale experiment, we obtained ${\sim}91^{\circ}C$ and $94^{\circ}C$ for CuO and TiNOX surfaces after 1 hr of solar illumination at single glazing, respectively. To measure the absorber performance at actual operating condition, outdoor experiment was also conducted using $110mm{\times}110mm$ absorber sample. We measured the solar flux with thermopile detector (919P-040-50). From outdoor experiment, we observed ${\sim}123^{\circ}C$ and $131^{\circ}C$ for CuO and TiNOX with 0.6 kW/m2 insolation at double glazing, respectively. We showed that the suggested nanostructured CuO solar absorber has near-equivalent collection efficiency compared with the state-of-the-art TiNOX surfaces even with much simpler manufacturing process that does not require an expensive equipment.

  • PDF

Experimental Study on Double Skin Composite Walls Subjected to Cyclic Loading (주기하중을 받는 이중강판합성벽의 실험연구)

  • Eom, Tae Sung;Park, Hong Gun;Kim, Jin Ho;Chang, In Hwa
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.289-301
    • /
    • 2008
  • Double skin composite (DSC) wall is a structural wall that is filed with concrete between two steel plate skins connected by tie bars. This type of wall was developed to enhance the structural performance of wall, to reduce wall thickness, and to enhance constructibility, eliminating the use of formwork and re-bars. In this study, cyclic tests were performed to investigate the inelastic behavior and earthquake resistance of isolated and coupled DSC walls with rectangular and T-shapedcross-sections. The DSC walls showed stable cyclic behaviors, exhibiting excellent energy dissipation capacity. The te st specimens failed by the tensile fracture of welded joints at the wall base and coupling beam and by the severe local buckling of the steel plate. The deformation capacity of the walls varied with the connection details at the wall base and their cross-sectional shapes. The specimens with well-detailed connections at the wall base showed relatively god deformation capacity ranging from 2.0% to 3.7% drift ratio. The load-carrying capacities of the isolated and coupled wall specimens were evaluated considering their inelastic behavior. The results were compared with the test results.

Development of Mandibular Movements Measuring System Using Double Stereo-Cameras

  • Park, Soon-Yong;Park, Sung-Kee;Cho, Chang-Hyun;Kim, Mun-Sang;Park, Mi-Gnon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1183-1188
    • /
    • 2005
  • In this paper, we propose a 3D automated measuring system which measures the mandibular movements and the reference plane of the jaw movements. In diagnosis and treatment of the malocclusions, it is necessary to estimate the mandibular movements and the reference plane of the jaw movements. The proposed system is configured with double stereo-cameras, PC, two moving pattern plates(MPPs), two fixed pattern plates(FPPs) and one orbital marker. The virtual pattern plate is applied to calculate the homogeneous transformation matrices which describe the coordinates systems of the FPP and MPP with respect to the world coordinates system. To estimate the parameters of the hinge axis, the Euler's theorem is applied. The hinge axis points are intersections between the FPPs and the hinge axis. The coordinates of a hinge axis point with respect to the MPP coordinates system are set up to fixed value. And then, the paths of the jaw movement can be calculated by applying the homogeneous transformation matrix to fixed hinge axis point. To examine the accuracy of the measurements, experiments of measuring the hinge axis points and floating paths of them are performed using the jaw motion simulator. As results, the measurement errors of the hinge axis points are within reasonable boundary, and the floating paths are very similar to the simulator's moving path.

  • PDF

Research on Improvement of Efficiency in Flat Plate Solar Collector by Using Double-Wall Glazing and VIP Insulation (이중투과체 및 VIP복합 단열재 적용 평판 집열기의 성능 향상에 대한 연구)

  • Lee, Doo Ho;Jang, Han Bin;Kim, Young Hak;Do, Kyu Hyung;Lee, Kwang Seob;Lyu, Nam Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.11
    • /
    • pp.458-465
    • /
    • 2016
  • The purpose of this research is to improve the thermal effiency of solar collector and to quantitatively analyze its performance. Solar thermal systems have been limited to water heating systems mainly using low-temperature range. However, through diverse developments, the application has been extended to medium- and high-temperature fields such as solar heating, solar air conditioning, and solar thermal industrial process. Among the diverse research, this research is specially focusing on enhancement of the thermal performance by minimizing the heat loss coefficient of flat plate solar collectors. In order to do it, a front-side glazing material and a back-side insulation material with high insulated structure is proposed and based on computational analysis, the performance of energy collecting volume of the proposed solar collector is analyzed. The research shows that the proposed structure has the excellent performance at medium- and high-temperature range. therefore, it is expected that the proposed structure can easily replace existing technologies.