• 제목/요약/키워드: Double orifice technique

검색결과 8건 처리시간 0.017초

Traumatic Tricuspid Regurgitation Treated by the Minimally Invasive Double Orifice Technique

  • Lee, Chan Kyu;Jang, Jae Hoon;Lee, Na Hyeon;Song, Seunghwan
    • Journal of Chest Surgery
    • /
    • 제54권1호
    • /
    • pp.68-71
    • /
    • 2021
  • A 37-year-old man was transferred to our level I trauma center after a road traffic accident, presenting with right acetabular fracture, multiple rib fractures, epidural hemorrhage, and liver contusion. Severe traumatic tricuspid regurgitation was also discovered during the work-up for surgery. Our initial attempt at acetabular surgery failed when the patient experienced near cardiac arrest during anesthetic induction. It was hence decided that tricuspid valve repair should precede orthopedic surgery. Minimally invasive tricuspid valve repair using the double orifice technique was successfully performed. Subsequently, acetabular surgery was performed and he was discharged 35 days post-trauma without any complications.

방실관결손증에 동반된 이중승모판 -2례 보고- (Double Mitral Valve Orifice in Atrioventricular Canal Defects)

  • 김수원;조범구
    • Journal of Chest Surgery
    • /
    • 제21권4호
    • /
    • pp.757-760
    • /
    • 1988
  • Double mitral valve orifice is an unusual congenital abnormality, and is rarely of clinical importance. That abnormality not produce hemodynamic deficits, but it has been associated with other congenital heart diseases, especially atrioventricular canal defects, and so it is surgically important condition. After the first report by M.S. Greenfield in 1876, there are only a few reported cases all over the world. We experienced two cases of double mitral valve orifice with atrioventricular canal defect. The small accessory mitral orifice was placed in anterior mitral leaflet as a hole type in both cases. The A-V canal defects are corrected with a one patch technique, but the accessory orifices are left unclosed because there were no mitral regurgitations through the orifice. On the 4th postoperative day, the patients have been performed echocardiography; both had no mitral regurgitation. Both of patients are now being follow-up and we find no specific problems. A small accessory mitral orifice may be left unclosed and rarely produce significant regurgitation, conclusively.

  • PDF

이미지 분리를 이용한 입자 속도 측정을 위한 홀로그래피 시스템의 개발 (Development of New Holography System for Measurments of Particle Velocities Using Separation of Images)

  • 강보선
    • 한국분무공학회지
    • /
    • 제2권2호
    • /
    • pp.16-23
    • /
    • 1997
  • In this research a novel two-reference-beam double pulse holographic technique for the measurments of particle sizes and velocities was developed. This holographic method features the capability of separation of the first and second particle images by using two reference beams instead of one and the change of the polarization direction of laser light. The developed holographic system was tested through the measurements of droplet sizes and velocities in the spray created by two high speed impinging jets. The overall spray pattern clearly revealed the inherent wave nature. Smaller and faster droplets were generated with larger impingement angle, higher jet velocity. and smaller orifice diameter.

  • PDF

후방 십자 인대 손상 치료의 개관(over view) (Overview of the PCL Reconstruction)

  • 정영복
    • 대한관절경학회지
    • /
    • 제2권1호
    • /
    • pp.1-3
    • /
    • 1998
  • The PCL reconstruction in chronic isolate PCL reconstruction was still controversy. 1) In isolate PCL deficient knee, functionally not so bad as like ACL deficient knee. 2) The result of the PCL reconstruction was not as good as ACL reconstruction. Therefore, isolate PCL injuries has been treated as nonoperatively. Hey Grovere, who was the first to attempt an intra-articular reconstruction of the PCL, utilized the semi-tendinous tendon other static procedures have been described in only a few cases with very limited follow-up. Dynamic procedures utilizing the medial head of the gastrocnemius has been reported by Hugston and Degenhardt, Kennedy and Grainger, and Insall and Hood. These procedures did not improve static stability. Dr Clancy, who was introduce the use of BPTB for the PCL reconstruction transtibial and femoral tunnel. From 1995, untill early 1990 PCL reconstruction was done as tend as placement of the isometric point. Physiometic placement of Anatomical placement of the femoral tunnel in PCL reconstruction were introduced in 1995. Tibial Inlay Technique was reported by Dr Berg in 1995. The main advantage of the tibial Inlay Technique was to avoid fraying of the graft at the posterior tibial tunnel orifice. In complete PCL ruptured and severely posterior unstable knee, dual femoral tunnel technique will be to get better result than one bundle technique. To achieve restoration of normal posterior laxity, it is critical to address the posterior as well as the posterolateral structures. Futher research is necessary to evaluate new surgical approches such as double-bundle reconstructions and tibial inlay techniques as well as improved techniques for capsular and collateral ligament injuries.

  • PDF

액체로켓용 FOOF와 FOF 인젝터의 분무특성 비교 (The Comparison of Spray Characteristics between FOOF and FOF Injectors used in Liquid Rockets)

  • 임병직;정기훈;윤영빈
    • 한국추진공학회지
    • /
    • 제7권2호
    • /
    • pp.1-6
    • /
    • 2003
  • 액체 산소와 탄화수소계 연료를 사용하는 로켓에서 삼중 충돌형(FOF, OFO) 인젝터가 흔히 사용된다. 일반적으로 FOF 형태가 OFO에 비해 낮은 성능을 보인다는 것이 알려져 있지만, 벽면 열전달에 있어서 보다 효율적인 방식이다. 한편, 산화제와 연료 분사구 직경 차가 큰 FOF 형태에서 산화제 분사구가 분리된 분리 삼중 충돌형 FOOF 인젝터(이하 FOOF 인젝터)가 제안된 바 있다. 본 연구에서는 비반응 분무 실험을 통해 FOOF 인젝터의 분무 특성을 FOF와 비교하였다. PLLIF 기법을 이용하여 산화제와 연료의 질량 분포를 측정하였고, 순간사진을 이용하여 액적의 크기를 측정하였다. 실험결과를 통해 FOOF 형태의 인젝터가 FOF에 비해 보다 안정적인 혼합 효율을 나타내며 액적 크기는 두 형태의 인젝터가 큰 차이 없이 비슷한 경향을 보임을 알 수 있었다.

인공심장판막의 개발과 동물실험 -인공심장판막의 2차 동물실험- (The Second Animal Tests of Artificial Heart Valves)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • 제23권4호
    • /
    • pp.617-621
    • /
    • 1990
  • A heart supplies blood of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to accomplish these enormous work of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of blood. In an attempt to eliminate the affliction of heart valves, the operative method to replace with artificial heart valves has developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. New artificial heart valves have been developed in Korea Advanced Institute of Science and Technology since early 1980`s. The first developed valve was designed with a free-floating pyrolytic carbon disk that is suspended in a titanium cage. The design of the valve was tested in vitro, and in animals in 1987. The results from this study was that the eccentrically placed struts creates a major and minor orifice when the disc opens and stagnation of flow in the area of the minor orifice has led to valve thrombosis. In this work, the design of the valve was changed from a single - leaflet valve to double - leaflet one in order to resolve the problems observed in the first - year tests. Morphological and hemodynamic studies were made for the newly designed valves through the in vitro and in vivo tests. The design and partial materials of the artificial heart valve was improved comparing with first - year`s model. The disc in the valve was modified from single - leaflet to bi - leaflet, and the material of the cage was changed from titanium metal to silicon - alloyed pyrolytic carbon. A test was made for the valve in order to examine its mechanical performance and stability. Morphological and hemodynamic studies were made for the valve that had been implanted in tricuspid position of mongrel dogs. All the test animals were observed just before the deaths. A new artificial heart valve was designed and fabricated in order to resolve the problems observed in the old model. The new valve was verified to have good stability and high resistance to wear through the performance tests. The hemodynamic properties of the valve after implantation were also estimated to be good in animal tests. Therefore, the results suggest that the newly designed valve in this work has a good quality in view of the biocompatibility. However, valve thrombosis on valve leaflets and annulus were found. This morphological findings were in accordance with results of surface polishing status studies, indicating that a technique of fine polishing of the surface is necessary to develop a valve with higher quality and performance.

  • PDF

변형술식에 의한 완전방실중격결손의 교정 (Repair of Complete Atrioventricular Septal Defect with Surgical Modification)

  • 김웅한;김수철;이택연;한미영;정철현;박영관;김종환
    • Journal of Chest Surgery
    • /
    • 제32권7호
    • /
    • pp.628-636
    • /
    • 1999
  • 배경: 최근에 완전방실중격결손의 해부학적 구조에 대한 이해가 증가됨에 따라서 본원에서는 수술방법에 있 어서 여러 가지 변형을 시도하게 되었다. 대상 및 방법: 1997년 5월부터 1998년 7월까지 8명의 완전방실중 격결손 환자를 수술하였다. 남녀 각각 3명, 5명이었으며 나이는 2개월에서 28개월까지 분포하였고 평균 몸무 게는 6.0$\pm$2.2 Kg이었다. 심장의 해부학적 구조에 따라서 3명의 환아에서는 심실중격결손을 일차적으로 봉합 하여 수술을 단순화하였다(Group I). 좌심실유출로 협착의 가능성이 있는 2명의 경우에는 통상적인 방법대로 2개의 포편을 이용하였다(Group II). 그리고 불균형 완전방실중격결손의 경우에는 심실중격결손을 막는 포편 을 우심실에 치우쳐서 막고 심방중격을 새로 만들거나 좌측 방실판막의 부족한 판막부위를 자가 심낭막으로 메꾸어 주거나 좌측 방실판막이 parachute valve 인 경우에는 2개의 판막입구를 만들어 주었다(Group III). 결과: 모든 환자가 수술후 만족스러운 혈류역학을 보였으며 7명에서는 평균 3$\pm$1 일만에 인공호흡기 이탈이 가능하였으며 1명의 환자는 심장의 문제없이 폐질환으로 24일만에 인공호흡기를 이탈하였다. 수술후 합병증 으로 III군에서 판막성형을 시행한 좌측 판막이 찢어지면서 판막역류가 점진적으로 심해진 1명에서 2주만에 재수술을 하였다. 조기 및 만기사망은 없었으며 수술후 심장초음파검사에서 약간의 좌측 방실판막협착이 III 군에서 1명 있었으며(평균압력차 6.5 mmHg), 좌측 방실판막역류가 7명(87.5 %)의 환아에서 Grade I 이하였으 며, 우측 방실판막역류는 모든 환아에서 Grade I 이하였다. 결론: 완전방실중격결손의 수술시 해부학적인 구 조에 따라서 선택적으로 일부 환아에서는 심실중격결손을 일차적으로 봉합함으로써 수술을 단순화할 수 있 으며 우심실이 발달된 불균형 완전방실중격결손에서도 변형수술방법을 통하여 양심실성 교정을 하여 좋은 결과를 얻을 수 있었다.

  • PDF

승모판폐쇄부전증를 가진 소아 환자에서 승모판성형술의 임상적 고찰 (Mitral Valve Repair for Mitral Regurgitation in Pediatric Patients)

  • 심형태;윤태진;박정준;정성호;엄주연;장원경;김영휘;고재곤;박인숙;서동만
    • Journal of Chest Surgery
    • /
    • 제40권8호
    • /
    • pp.536-545
    • /
    • 2007
  • 배경: 소아 환자에서의 승모판폐쇄부전은 성인에 비해 상대적으로 드물고 다양한 형태의 병변을 보인다. 또한 수술 기법도 덜 정형화되어 있으며 그 결과에 대한보고는 드물다. 본 연구는 이러한 다양한 원인에 의한 승모판페쇄부전이 있었던 소아 환자에 대해 시행된 승모판성형술의 결과를 후향적으로 분석하고자 하였다. 대상 및 방법: 1993년 12월부터 2006년 8월까지 승모판폐쇄부전으로 수술 받은 18세 이하의 환자 35명을 대상으로 하였다. 수술 당시 평균 연령은 $5.3{\pm}5.3$세였고 평균 체중은 $20.0{\pm}16.3kg$이었다. 술 전 승모판폐쇄부전의 정도는 Grade II가 9예, III, IV가 각각 16예, 10예였다. 18예에서 심장 기형을 동반하고 있었으며 심실중격결손이 9예로 가장 많았고, 주관상동맥-폐동맥 이상 연결증, 좌측 주관상동맥기시부 폐쇄 등도 각각 2예, 1예 있었다. 승모판의 병리적 소견은 판막엽의 탈출증이 17예로 가장 많았고, 판막에 열이 있는 경우가 7예, 짧은 건삭을 보인 경우가 6예, 판막륜의 확장을 보인 경우가 5예, 허혈성유두상근을 보인 경우가 2예, 유두상근형성부전이 1예 있었고, 심내막염에 의한 건삭파열이 1예 있었다. 승모판성형술은 이중입구성형술이 15예로 가장 많이 시행되었고, 봉합판막륜성형술 14예, 판막열 봉합술 7예, 유두상근 분리술 5예, 링을 이용한 판막륜 성형술 4예, 판막엽 절제술 4예, 신건삭 형성술 2예 각각 시행되었다. 술 후 평균 추적 관찰 기간은 $47.5{\pm}39.0$개월($2{\sim}138$개월)이었다. 결과: 수술 후 조기 사망은 없었다. 술 후 승모판폐쇄부전의 정도는 1명의 환자를 제외하고 모두 의미 있는 감소를 보였다. 8명(24.2%)이 재수술을 시행 받았고 이 중 5명은 승모판치환술을 받았다. 재수술의 원인으로는 승모판 협착이 3예, 잔류 승모판폐쇄부전이 5예였다. 승모판협착은 링을 이용하여 수술한 4명의 환자 중에서 2명이 발생하였고, 폐쇄부전은 이중입구성형술을 시행 받은 환자 14명중에서 4명에서 발생하였다. 재수술 후 조기 사망 1명, 만기 사망 1 명이 있었다. 환자들의 5년 생존율은 $93.3{\pm}4.6%$, 5년 재수술의 회피율은 $76.1{\pm}8.2%$, 5년 승모판치환술의 회피율은 $83.6{\pm}6.7%$였다. 통계학적으로 의미 있는 재수술의 위험인자는 발견할 수 없었다. 결론: 승모판폐쇄부전이 있는 소아 환자에서 시행된 승모판 성형술은 양호한 중단기 성적을 보였으나 비교적 높은 재수술의 가능성은 남아 있어 향후 재수술의 원인과 대책에 대한 좀더 깊이 있는 연구가 필요하다고 생각한다.