• Title/Summary/Keyword: Double chamber

Search Result 134, Processing Time 0.027 seconds

Fabrication of a 18cm long YBCO coated conductor using a cylindrical tape holder in a double chamber co-evaporation system (이중 챔버를 가진 동시증발 시스템 내에서 실린더 홀더를 이용한 18cm 길이의 YBCO coated conductor의 제작)

  • Oh, Sang-Hyun;Jung, Kook-Chae;Youm, Do-Jun
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.322-325
    • /
    • 1999
  • We fabricated 18cm YBCO coated conductor comprising a YBCO superconducting film and CeO$_2$/YSZ/CeO$_2$ buffer films deposited on a biaxially textured Ni tape. For those film fabrications, we developed a new method, the cylindrical holder in a double chamber. This is alternative to the reel-to-reef method which is commonly tried to fabricate a long YBCO coated tape. We will discuss about the superconducting properties of the 18cm long YBCO coated tapes.

  • PDF

Numerical Study on Combined Heat Transfer in NIR Dryer for Agricultural and Marine Products (근적외선 농수산물 건조기의 복합열전달특성에 관한 수치적 연구)

  • Choi, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.395-402
    • /
    • 2006
  • Mixed heat transfer in an indirected NIR (Near Infrared Ray) dry chamber was investigated numerical analysis. It is Important that the miked heat transfer effects on double parameters which the Reynolds number and the position of emit lamp. Reynolds number are based on the outer diameter of the cylinder range from 103 to $30{\times}105$. Four difference heat transfer regimes of behavior are apparent: forced convection and radiation on the outer surface of the cylinder, pure conduction, pure natural convection and radiation between lamp surface and inner surface of the cylinder. The temperature and flow patterns are illustrated by iso-contour lines for the double parameters. Also presented are results on the convective heat transfer flux and the radiative heat transfer flux as increased with Reynolds number.

Measurements of Photoabsorption Cross Sections of Nitric Oxide by Using Double-Ionization Chamber

  • Chung, Yang-Soo;Kim, Hyun;Chung, Young-Min
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.4
    • /
    • pp.157-161
    • /
    • 2006
  • A synchrotron light source is useful in the vacuum ultraviolet (VUV) regime for olecular spectroscopy, such as photo absorption, photoionization, and dissociative hotoionization. In this research, we used a double-ion chamber (DIC) to measure hotoabsorption cross sections of a NO molecule in the wavelength range from 90 to 135 nm of 3B1 beam-line of the Pohang synchrotron light source with the resolution of the onochromator being 0.06 nm. The appearance wavelength for ionization was measured to be $134.19{\pm}0.09nm$ that is placed in the middle of the reported values though they don't agree with each other within the relative error limits. The auxiliary experimental works ave been done to test if there are any systematic error sources. The resultant ross-sections agree with previous results in general.

Characteristics of Heat Transmission Variation by Air Space Thickness and Injected Air Temperature in Air-Inflated Double Layers Film (공기막 이중필름의 공기막 두께와 주입공기 온도에 따른 관류전열량 변화 특성)

  • Kim, Hyung-Kweon;Jeon, Jong-Gil;Paek, Yee;Lee, Sang-Ho;Yun, Nam-Kyu;Yoo, Ju-Yeol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.6
    • /
    • pp.121-125
    • /
    • 2013
  • This study was carried out to provide a valuable reference which could reduce heating loss of air-inflated double PO film. Therefore, this study was aimed to choose the best air space thickness and injected air temperature. The characteristics of heat transmission variation at experimental materials were measured and analysed in the laboratory. The experiment was conducted of two layers of PO film, each 0.15 mm tick, sandwiching 110, 175, 225 mm of inflated air with 1 m sides. Environmental control lab was constantly controlled with $-10^{\circ}C$ and experiment chamber was constantly changed with 0, 5, 10, $15^{\circ}C$. The analysis of heat transfer showed that heat transmission does not have a direct correlation with Air Space thickness and injected air temperature. But when inside and outside temperature difference of chamber was great, supply of outside air to Air Space had an advantage at reduction of heating load. It was required to examine accurate analysis at a real greenhouse.

Effect of Chamber Configuration on Combustion Characteristic Velocity of Full-scale Combustion Chamber (실물형 연소기의 형상에 따른 연소특성속도 비교)

  • Kim, Jong-Gyu;Han, Yeoung-Min;Ahn, Kyu-Bok;Kim, Mun-Ki;Seo, Seong-Hyeon;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.149-152
    • /
    • 2008
  • Effects of chamber configuration on combustion characteristic velocity of full-scale combustion chamber for 30-tonf-class liquid rocket engine were studied. The configurations of combustion chamber are ablative and channel cooling chamber (${\varepsilon}$=3.2) which have detachable mixing head, and single body regenerative cooling chamber which has nozzle expansion ratio of 3.5 and 12, respectively. The combustion chambers have chamber pressure of 53${\sim}$60 bar and propellant mass flow rate of 89 kg/s, and the injectors of all combustion chamber have recess number 1.0 and double-swirl characteristics. The hot firing test results at design point show that the combustion characteristic velocity of the regenerative cooling chamber which has nozzle expansion ratio of 12 is higher than that of other combustion chambers. The reasons for the above result are the increases of combustion pressure and enthalpy of kerosene which is heated due to cooling of the chamber wall before injection into the combustion field.

  • PDF

A prediction of indoor pollutant concentration using method mass transfer coefficient in multi-layered building materials (복합 건축자재의 물질전달계수를 이용한 실내 오염물질 농도 예측방법)

  • Kim, Chang Nam;Lee, Yun Gyu;Leigh, Seung Bok;Kim, Tae Yeon
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.53-58
    • /
    • 2007
  • In order to predict the indoor air pollutant, the VOCs emission rate is used through small chamber in the design process. However, the small chamber method has limitations as the convective mass transfer coefficient, the most important factor when predicting VOCs contamination of indoor air, is different between the small chamber result and the measured data in the actual building. Furthermore, the existing studies which analyzed mass transfer coefficient in the small chamber were directed on the small chambers developed at the time and FLEC(Field and Laboratory Emission Cell), thus, are different from the current small chamber which has been changed with improvements. The purpose of this study is to determine the emission rate of pollutant in multi-layered building materials, and predict the indoor pollutant concentration through the CFD(Computational of Fluid Dynamics) and CRIAQ2 based on the mass transfer coefficient on singled-layered building material by using the current small chamber widely used in Korea. Futhermore, this study used the new convective mass transfer coefficient(hm') which indicates the existing convective mass transfer coefficient(hm) including VOC partition coefficient(k). Also, formaldehyde was selected as target pollutant.

A Comparative Experimental Study on Thermal Performance of Box-typed Double Skin and Curtain Wall in Cooling Period (박스형 이중외피와 커튼월의 냉방기 열적성능에 관한 비교실험 연구)

  • Park, Chang-Young;Lee, Keon-Ho;Yoon, Yong-Sang;Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.111-119
    • /
    • 2007
  • The annual mean temperature of South Korea has risen by $1.3^{\circ}C$ for last 100 years by urbanization and industrialization. Especially, the frequency of unusual hot weather in summer increases for a long time and the frequency of unusual cold weather in winter clearly decreases. In recently, The considerable portion of curtain wall system is appled to building skin in domestic. As related to this, the Korea Institute of Construction Technology devised the box typed double skin facade(It is occasionally called as FDFS : Functional Double Facade System) as an alternative that reflects the distinctive local climate and saves cooling energy. Two mock-ups($49m^*4.9m$) applied to single skin(curtain wall) and double skin each were monitored under the outdoor condition. Therefore, the characteristics of natural ventilation and cooling energy consumption of each window had been analyzed in real time. The results of this study are summarized as follow, Analysis of the experiment on an air conditioner: the indoor temperature of the chamber with FDFS is lower than that of the chamber with single skin facades by $3{\sim}6$ degrees(C). A temperature variation of about $1{\sim}2$ degrees between the 0.2m and 1.7m height of the mock-up occurs in FDFS, while that of about maximum 7 degrees occurs in single skin facade at noon with abundant intensity of solar accident. Also, 67 percent of energy consumption for air conditioning has been saved.

Empirical Research for the Sound Insertion Loss of Panels (다중 페널의 차음성능에 대한 실험적 연구)

  • Ko, Kang-Ho;Kook, Hyung-Seok;Kim, Young-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.198-203
    • /
    • 2001
  • This paper discusses an experimental method for measuring the insertion loss (IL) performance of a double panel that are used in vehicles. Instead of two adjacent reverberation chambers which are generally used to measure the transmission loss (TL) of the large sound isolation materials, air-borne sound insulation tester was utilized to determine the IL and articulation index (AI) of standardized deadening materials. In comparison to reverberation chamber method, air-borne sound insulation tester method is more space-saving, more time-saving and more simple to the automotive acoustics. From the empirical results, it is verified that the performance of deadening materials is closely connected with thickness of panels, type of filling material that is filled into a double panel, and area ratio of double panel.

  • PDF

The Flow Analysis and Evaluation of the Peristaltic Micropump (마이크로 정량펌프의 유동해석과 작동성능 평가)

  • 박대섭;최종필;김병희;장인배;김헌영
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.2
    • /
    • pp.195-202
    • /
    • 2004
  • This paper presents the fabrication and evaluation of mechanical behavior for a peristaltic micropump by flow simulation. The valve-less micropump using the diffuser/nozzle is consists of the lower plate, the middle plate, the upper plate and the tube that connects inlet and outlet of the pump. The lower plate includes the channel and the chamber, and the plain middle plate are made of glass and actuated by the piezoelectric translator. Channels and a chamber on the lower plate are fabricated on high processability silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The upper plate does the roll of a pump cover and has inlet/outlet/electric holes. Three plates are laminated by the aligner and bonded by the anodic bonding process. Flow simulation is performed using error-reduced finite volume method (FVM). As results of the flow simulation and experiments, the single chamber pump has severe flow problems, such as a backflow and large fluctuation of a flow rate. It is proved that the double-chamber micropump proposed in this paper can reduce the drawback of the single-chamber one.

Combustion Characteristics of High Pressure Thrust Chamber with Single Coaxial Swirl Injector (이중와류 분사기를 적용한 고압 모델 연소기의 연소 특성 연구)

  • Seo, Seong-Hyeon;Lee, Kwang-Jin;Han, Yeoung-Min;Kim, Seung-Han;Kim, Jong-Gyu;Seol, Woo-Seok
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.131-136
    • /
    • 2003
  • Experimental study on combustion characteristics of double swirl coaxial injectors has been conducted for the assessment of critical design parameters of injectors. A subscale thrust chamber has been fabricated with a water-cooled copper nozzle, which allows a chamber to be reused without replacing parts. Two different designs of injectors have been tested for the understanding of the effects of recess length on combustion. Clearly, the recess length drastically affects the combustion efficiency and hydraulic characteristics of the injector. Internal mixing of propellants in the injector with the recess number of two increases a combustion efficiency and reveals sound combustion although a pressure drop required for the similar amount of mass flow rates increases compared with the injector of the recess number of one.

  • PDF