• Title/Summary/Keyword: Double Operation

Search Result 827, Processing Time 0.027 seconds

Correction of Small Eye Opening with Combined Method (복합 안검 성형술을 이용한 작은 눈의 교정)

  • Joh, Se Heum;Lee, Han Earl;Lee, Hae Min
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.187-192
    • /
    • 2008
  • Purpose: Generally speaking, most of Korean have smaller eyes than those of Caucasian and they have epicanthus with narrow palpebral fissure. It makes external appearance looking dull because the length of the palpebral fissure is short and there is a epicanthus. In case the function of the levator muscle is weak, their eyes look much smaller. Epicanthus and weak levator muscle function make the eyes look dull. The above mentioned, authors want to introduce double eyelid operation, epicanthoplasty, levator plication to extend and lengthen the palpebral fissure. Methods: From August 2001 to August 2004, there were 138 cases that had double eyelid operation with epicanthoplasty or levator plication. the 69 cases of them had double eyelid operation and epicanthoplasty, the 33 cases of them had double eyelid operation and levator plication and the 36 cases of them had double eyelid operation and epicanthoplasty and levator plication. Results: After the operation, the length and height of the eyelid are improved remarkably, and most of the patients were satisfied. The length of the eyelid is improved 3 to 5mm($3.4{\pm}0.5mm$) in case of the epicanthoplasty, the width of the eyelid is improved 3 to 4mm($3.1{\pm}0.3mm$) by the levator plication. The length of the eyelid is improved 3 to 5($3.4{\pm}0.4mm$) and the width is improved 2 to 4mm($2.9{\pm}0.5mm$) by the epicanthoplasty used levator plication. Conclusion: The improvement of the eyelid length is almost the same as epicanthoplasty and levator plication are done simultaneously. But the improvement of the eyelid width is less shorter when epicanthoplasty and levator plication are done simultaneously than the case of levator plication alone. This is because there is a tension influencing on the limitation of widening palpebral fissure to fix the epicanthal tendon. This method is recommendable for the patients who want to have much bigger eyes.

Output Waveform Improvement of Double-Connected 3-Phase Voltage Source Inverter by Single-Phase Inverter (단상 인버터의 동작에 의한 이중접속 3상 전압원 인버터의 출력파형 개선)

  • 최세완
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.330-334
    • /
    • 2000
  • This paper proposes a new double-connected 3-phase voltage source inverter with improved output voltage waveform. An auxiliary single-phase inverter injects a ripple voltage into the double- connected inverter to convert 12-step operation to 36-step operation. The KVA rating of the output phase-shifting transformer is reduced by employing a harmonic canceling reactor. The whole rectifier-inverter system including the proposed technique is introduced and the experimental results are provided.

  • PDF

Characteristics of DC Plasma Display Panel with Double Pulse Memory (Double Pulse Memory 방식을 이용한 DC Plasma Display Panel의 특성 연구)

  • 최경철;신범재;왕기웅
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.29B no.1
    • /
    • pp.67-75
    • /
    • 1992
  • A new method of driving the PDP(Plasma Display Panel) was proposed and its characteristics were investigated. Applying high frequency non-discharge pulses to an auxiliary anode resulted an increased region of stable operation, decreased delay time and increased light intensity. It is suggested that PDP with DPM (Double Pulse Memory) drive technique improves the delay time, luminance, region of stable operation and luminous efficacy compared to PDP with PPM(Planar Pulse Memory) drive technique developed by NHK Lab. in Japan.

  • PDF

Double Encryption of Binary Image using a Random Phase Mask and Two-step Phase-shifting Digital Holography (랜덤 위상 마스크와 2-단계 위상 천이 디지털 홀로그래피를 이용한 이진 영상 이중 암호화)

  • Kim, Cheolsu
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.6
    • /
    • pp.1043-1051
    • /
    • 2016
  • In this paper, double encryption technique of binary image using random phase mask and 2-step phase-shifting digital holography is proposed. After phase modulating of binary image, firstly, random phase mask to be used as key image is generated through the XOR operation with the binary phase image. And the first encrypted image is encrypted again through the fresnel transform and 2-step phase-shifting digital holography. In the decryption, simple arithmetic operation and inverse Fresnel transform are used to get the first decryption image, and second decryption image is generated through XOR operation between first decryption image and key image. Finally, the original binary image is recovered through phase modulation.

Correction of High Fold without Skin Excision (피부 제거 없이 시행한 높은 쌍꺼풀의 교정)

  • Oh, Heung Chan;Yoon, Dong Ju;Kang, Cheol Uk;Choi, Chi Won;Choi, Soo Jong;Bae, Yong Chan
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.649-653
    • /
    • 2009
  • Purpose: Double - eyelid operation is one of the most common cosmetic operations among Korean patients. In such operations, however, the complexity of and individual differences in the patients' anatomical structures may cause various complications, such as asymmetry, retraction of the eyelid, and the occurrence of a high fold. A high fold occurs frequently, and its correction is not very simple. Many methods have been developed to correct it, and among these, the operation involving the excision of the skin between the previous double - eyelid line and the new double - eyelid line is usually selected by plastic surgeons. In many cases, however, patients have insufficient eyelid skins for this operation. In this study, the authors introduce an operation procedure for high - fold correction that does not involve skin excision Methods: From June 2005 to June 2009, 246 cases were treated with this procedure. After the incision of the new double - eyelid line, dissection was done between the previous scar tissue and the levator aponeurosis. Then the orbital septum, orbital fat or the retro - orbicularis oculi fat was slid down and sutured with a tarsal plate. Such sutures were repeated at four to five points, including the lateral and medial limbus, to prevent the reattachment of the previous scar and to create a new double - eyelid line at the end of the orbital septum. Results: Most of the high - fold patients were satisfied with the procedure described above. Their previous scar was hidden under the new double - eyelid line after the operation. In the six cases, the scar was visible in the patients who had a very high and deep inner line. As such, scar revision was undertaken three months after the operation. It is known that scar revision is also required after an operation involving skin excision in the case of a very high inner - eyelid line. Conclusion: This method is an appropriative procedure for high - fold correction for patients who have insufficient upper - eyelid skin.

Design and Feasibility Study of Double Gerotor (이중 제로터의 설계 및 응용 가능성에 대한 연구)

  • Lee, Sung-chul
    • Tribology and Lubricants
    • /
    • v.35 no.4
    • /
    • pp.215-221
    • /
    • 2019
  • A gerotor set consists of two elements, an inner rotor and an outer rotor. The outer rotor has one more tooth than the inner rotor and has its centerline positioned at a fixed eccentricity from the centerline of the inner rotor. Although gerotors come in a variety of geometric configurations, all gerotor sets share the basic principle of having generated tooth profiles that provide continuous tight sealing during operation. The size of the gerotor is proportional to the number of teeth and the amount of eccentricity. The interior of an inner rotor with a large number of teeth has an enough space to include other machine elements. In this paper, the double gerotor mechanism, constructed by putting a small gerotor in the interior of a large inner rotor, is conceptualized. The double gerotor set is composed of an inner rotor, a planetary rotor, and an outer rotor. The inside profile of the planetary rotor corresponds to the outer rotor profile of the small gerotor, and the outside profile is the inner rotor profile of the large gerotor. In the double gerotor, the centers of the inner and the outer rotor are coincident because the eccentricities of two gerotors are balanced. The operation of a double gerotor is examined by analyzing the planetary motion, and a feasibility study for application of the double gerotor for hydraulic motors and pumps is performed. The double gerotor set has much application potential as a component of hydraulic systems.

Study on the Structure Optimization and the Operation Scheme Design of a Double-Tube Once-Through Steam Generator

  • Wei, Xinyu;Wu, Shifa;Wang, Pengfei;Zhao, Fuyu
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.1022-1035
    • /
    • 2016
  • A double-tube once-through steam generator (DOTSG) consisting of an outer straight tube and an inner helical tube is studied in this work. First, the structure of the DOTSG is optimized by considering two different objective functions. The tube length and the total pressure drop are considered as the first and second objective functions, respectively. Because the DOTSG is divided into the subcooled, boiling, and superheated sections according to the different secondary fluid states, the pitches in the three sections are defined as the optimization variables. A multi-objective optimization model is established and solved by particle swarm optimization. The optimization pitch is small in the subcooled region and superheated region, and large in the boiling region. Considering the availability of the optimum structure at power levels below 100% full power, we propose a new operating scheme that can fix the boundaries between the three heat-transfer sections. The operation scheme is proposed on the basis of data for full power, and the operation parameters are calculated at low power level. The primary inlet and outlet temperatures, as well as flow rate and secondary outlet temperature are changed according to the operation procedure.

Point Quadruple Operation on Elliptic Curve Cryptography Algorithm (타원 곡선 암호 알고리즘의 네배점 스칼라 연산)

  • 문상국;허창우;유광열
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.784-787
    • /
    • 2004
  • The most time-consuming back-bone operation in an elliptic curve cryptosystem is scalar multiplication. In this paper, we propose a method of inducing a GF operation named point quadruple operation to be used in the quad-and-add algorithm, whith was achieved by refining the traditional double-and-add algorithm. Induced expression of the algorithm was verified and proven by C program in a real model of calculation. The point quadruple operation can be used in fast and efficient implementation of scalar multiplication operation.

  • PDF

Sub-Synchronous Range of Operation for a Wind Driven Double-Fed Induction Generator

  • Saleh, Mahmoud Abdel Halim;Eskander, Mona Naguib
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.72-78
    • /
    • 2010
  • In this paper the operation of a double-fed wound-rotor induction machine, coupled to a wind turbine, as a generator at sub-synchronous speeds is investigated. A novel approach is used in the analysis, namely, the rotor power flow approach. The conditions necessary for operating the machine as a double-fed induction generator (DFIG) are deduced. Formulae describing the factors affecting the range of sub-synchronous speeds within which generation occurs are deduced. The variations in the magnitude and phase angle of the voltage injected to the rotor circuit as the speed of the machine changes to achieve generation at the widest possible sub-synchronous speed range is presented. Also, the effect of the rotor parameters on the generation range is presented. The analysis proved that the generation range could increase from sub-synchronous to super-synchronous speeds, which increases the amount of energy captured by the wind energy conversion system (WECS) as result of utilizing the power available in the wind at low wind speeds.

Output Waveform Improvement of Double-Connected 3-Phase Voltage Source Inverter by Single-Phase Inverter (단상 인버터의 동작에 의한 이중접속 3상 전압원 인버터의 출력파형 개선)

  • 최세완;양승욱
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.21-26
    • /
    • 2001
  • This paper proposes a new double-connected 3-phase voltage source inverter with improved output voltage waveform. An auxiliary single-phase inverter injects a ripple voltage into the double-connected inverter to converter 12-step operation to 36-step operation. The KVA rating of the output phase-shifting transformer is reduced by employing a harmonic canceling reactor. The whole rectifier-inverter system including the proposed technique is introduced, and the experimental results are provided.

  • PDF