Pulmonary adenocarcinoma in a slaughtered female Hanwoo

  • Yang, Hyoung-Seok;Kim, Jae-Hoon
    • Korean Journal of Veterinary Research
    • /
    • v.59 no.1
    • /
    • pp.51-54
    • /
    • 2019
  • Pulmonary masses were observed in the thoracic cavity of a 9-year-old female Korean native cattle (Hanwoo) encountered at a Jeju, Korea slaughterhouse. Grossly, the thoracic cavity was filled with pulmonary masses. Histologically, the neoplastic masses were composed of many abnormal papillary structures lined by single to double columnar neoplastic cells and formed arborizing fronds supported by significant fibrovascular stroma. The neoplastic cells showed strong destructive and infiltrative growth to adjacent tissues and were strongly positive for pan-cytokeratin (CK), CK 7 and sporadically positive for CK MNF116. The masses in the female Hanwoo were diagnosed as a papillary pattern of pulmonary adenocarcinoma.

Double Processing Obturator for the Hemi-maxillectomy Treated Patient (Hemi-Maxillectomy 환자에서 이중온성법을 이용한 폐색장치의 제작)

  • Hong, Jun-won;Song, Kwang-yeob;Park, Mi-hee;Jeong, Soo-yang;Kim, Kyoung-il;Ahn, Seung-geun;Park, Ju-mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.329-336
    • /
    • 2009
  • In the case of congenital malformation, acquired trauma, or maxillectomy by neoplasm, the defect in maxilla is combined with nasal cavity, maxillary sinus and oral cavity. This results in abnormal function in pronunciation, mastication, and swallowing. In this situation, the purposes of prosthodontics are also applied. The purposes of obturator for acquired maxillary deficiency patients are restoring pronunciation, mastication, and swallowing, and make patients comfortable and esthetic satisfaction. Reducing weight of the obturator makes edentulous ridge heathy and functional. It also improves patients' comfort. Hollow obturator also reduces unnecessary stress because improves physiologic function, as it weights less than 6.55-33.06% compare to usual one. This case presents the double-processing method for maxillary obturator in the patient treated hemi-maxillectomy due to malignancy neoplasm. We report this case because the patient acquired functional and esthetic satisfaction from double-processing obturator.

Double Paddle Pectoralis Major Myocutaneous Flap for Simultaneous Reconstruction of Oro-or Pharyngocutaneous Fistula (구강 혹은 인두피부루의 동시재건을 위한 양면 대흉근피판술)

  • Lim Young-Chang;Son Eun-Jin;Shin Woo-Chul;Kim Sang-Cheol;Lee Wook-Jin;Choi Eun-Chang
    • Korean Journal of Head & Neck Oncology
    • /
    • v.19 no.1
    • /
    • pp.47-51
    • /
    • 2003
  • Background and Objectives: Oro-and pharyngocutaneous fistula after irradiation can lead to extensive wound necrosis and fetal complication such as carotid rutpure. So, there is a need to clean and cover the wound rapidly in these compromised patients. Pectoralis major myocutaneous (PMMC) flap has been presented for reconstruction of complex defects in these irradiated patients. We applied the double paddle PMMC flap for the simultaneous reconstruction of above complex defects and evaluated the it's clinical efficacy. Material and Methods: Retrospective chart review of three cases of simultaneous head and neck reconstruction after irradiation with double paddle PMMC. All patients received prior radiotherpy before development of complications. The double paddle PMMC flap was used for mucosal lining of the oral cavity and epithelial lining of external skin in 2 cases, for mucosal lining of the pharynx and epithelial lining of external skin in 1 case. Results: Considerable complications such as major flap necrosis or fistula did not occur in any of the cases, and simultaneous reconstruction was achieved in all cases without reoperations. Conclusion: Many extended defects such as oro-and pharyngocutaneous fistula involving cover and lining about the head and neck after irradiation can be rehabilitated by the double paddle pectoralis major myocutaneous flap.

Anal Extrusion of Distal V-P Shunt Catheter after Double Perforation of Large Intestine

  • Jang, Hyun-Dong;Kim, Min-Su;Lee, Nam-Hyuk;Kim, Seong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.3
    • /
    • pp.232-234
    • /
    • 2007
  • We describe the extrusion of a ventriculoperitoneal shunt catheter from the anus after double perforation of the large bowel in a 3-year-old girl with hydrocephalus. She was admitted because the tip of the peritoneal catheter protruded 10 cm from the anus and clear cerebrospinal fluid dripped from the tip. Emergency laparotomy was performed. The distal peritoneal catheter perforated and penetrated the sigmoid colon and re-perforated into the rectal cavity. The distal peritoneal catheter was removed, the proximal catheter was exposed for external drainage, and intravenous broad-spectrum antibiotics were administered for 2 weeks. After control of infection, the shunt system was completely removed. Bowel perforation by a peritoneal catheter is a rare complication. Diagnosis is often difficult, delayed, and its incidence is likely underestimated. Most bowel perforation is the result of infection as opposed to technical errors.

Study on Warm Precision Forging of Half Axle Gears

  • Jie Zhou;Yong Zhang
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10b
    • /
    • pp.152-157
    • /
    • 2003
  • A typical die-set for enclosed-die forging of half axle gears in double action hydraulic press is presented, the important factors those influence on precision forming of half axle gears are analyzed, warm forming process of half axle gears is simulated by FEM software $DEFORM\_3D$. The results show, that proper die structure and dimension, suitable web thickness and position can improve material filling, ensure full filling of tooth cavity.

  • PDF

A study on the generating plasma by microwave (마이크로파를 이용한 플라즈마 발생에 관한 연구)

  • Whang, Ki-Woong;Lee, Jeong-Hae
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.300-303
    • /
    • 1987
  • A microwave plasma generating system has been designed to study the properties of plasma. A microwave(2.45GHz) generated by the magnetron is transmitted to the cylindrical cavity through the the rectangular wave guide to generate hydrogen plasma. The electron temperature and the plasma density are measured by the Double Langmuir probe. A dilectric such as alumina is heated by the microwave add plasma. The surface temperature varies with the neutral gas pressure.

  • PDF

Double-Fused 1.5 $\mu\textrm{M}$ Vertical Cavity Surface Emitting Lasers (이중 기판용융접합된 장파장 수직 공진 표면광 레이저)

  • 송대성;김창규;이용희
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.144-145
    • /
    • 2001
  • 장파장 수직 공진 표면광 레이저는 편리성, 경제성 및 확장성 때문에 많은 주목을 받아 왔다. 이것은 2차원 행렬로 기판에 제작되어 기판 상에서 테스트가 가능하고 기판 표면으로 광 출력이 되는 장점이 있어 모듈 제작비용을 낮출 수 있다. 또한 출력광의 모양을 원형으로 하면 광섬유 연결 효율이 좋아서 광 연결에 필요한 광학부품을 최소화할 수 있다. 특히 1.3-1.55$mu extrm{m}$ 수직 공진 표면광 레이저는 광섬유에서의 분산과 손실이 가장 낮아서 광통신용 광원으로 많은 연구가 진행되고 있다. (중략)

  • PDF

Double-Diffusive Convection in a Salt-Stratified Fluid Heated From Below (농도 성층화된 유체의 아랫면 가열에 의한 이중확산대류에 관한 연구)

  • 강신형;김무현;이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3297-3304
    • /
    • 1994
  • Experimental investigation have been made to study the double-diffusive nature of convection of an initially stratified salt-water solution heated from below in a cylindrical cavity. The objective is to examine the process of mixed-layer formation, the flow phenomena, the heat transfer characteristics, and temperature and concentration distribution according to the changes in the effective Rayleigh number based on the reference height which represents the relation of temperature and concentration gradient. The types of initially formed flow pattern are categorized in three regimes depending on the effective Rayleigh number ; stagnant flow regime, single mixed-layer flow regime and successively formed multiple mixed-layer flow regime. The temperature and concentration profiles are both uniform in each layer due to convective mixing in the layered flow regime, but both linear in stagnant flow regime and single mixed-layer flow regime. At the interface between adjacent layers, the temperature changes smoothly but the concentration changes rapidly. The layers expand by diffusion of concentration through the interface along with its random fluctuation.

Vortex Cavitation from Baffle Plate and Pump Vibration in a Double-Suction Volute Pump

  • Sato, Toshiyuki;Nagahara, Takahide;Tanaka, Kazuhiro;Fuchiwaki, Masaki;Shimizu, Fumio;Inoue, Akira
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.76-83
    • /
    • 2011
  • This study highlights especially the mechanism of vortex cavitation occurrence from the end of the suction duct in a double-suction volute pump and pump oscillation which causes cavitation noise from the pump. In this study, full 3D numerical simulations have been performed using a commercial code inside the pump from the inlet of suction duct to the outlet of delivery duct. The numerical model is based on a combination of multiphase flow equations with the truncated version of the Rayleigh-Plesset model predicting the complicated growth and collapse process of cavity bubbles. The experimental investigations have also been performed on the cavitating flow with flow visualization to evaluate the numerical results.

Calibration of Double-skin Simulation Model Depending on Configuration And Impact of Local Weather Information (이중외피 형상에 따른 모델 보정과 local 기상 정보의 필요성)

  • Yoon, Kyeong-Soo;Kim, Deuk-Woo;Lee, Keon-Ho;Park, Cheol-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.142-147
    • /
    • 2009
  • In order to achieve performance assessment and optimal control of a double-skin system, an accurate simulation model is required. In the previous study, a lumped simulation model of such system was developed. As a follow-up of the previous research, the first objective of this paper is to investigate how the mathematical model should be calibrated according to system configuration(cavity width, depth, height, airflow pattern, local environment, etc.). And the second objective of this study is to discuss the effect of local weather information. In conclusion, this paper describes that the model should be recalibrated according to configuration. And it is necessary to have local weather information for accurate prediction and optimal control of the system.

  • PDF