The Statistical Technique for Dosimetric Meta-Analysis at in-vivo and in-vitro Papers about Bioeffects of RF Electromagnetic Field (RF 전자기장 생체 영향 연구 문헌에서 노출량 메타분석을 위한 통계적 기법)

  • Choi, Sung-Ho;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.12
    • /
    • pp.1311-1320
    • /
    • 2003
  • This paper proposed the estimating method of electromagnetic dosimetric reliability at in-vivo and in-vitro experiments. For more accurate consequences of these researches, we have tried to find out any correlations among output power, power density and specific absorption rate(SAR) with the results of in-vivo, in-vitro tests and SAR reports of cellular phone and PDA. In the case of in-vivo tests, the power density has close statistical correlations with SAR value and in the event of in-vitro tests, the output power has considerable statistical correlations with SAR containing duty factor. We analysed the coefficient of determination to estimate the dosimeoic uncertainty. If we use this method before evaluating techniques of measurement and analysis at both in-vivo and in-vitro experiments, we will conduct more accurate reliability test.

Evaluations of a Commercial CLEANBOLUS-WHITE for Clinical Application

  • Geum Bong Yu;Jung-in Kim;Jaeman Son
    • Progress in Medical Physics
    • /
    • v.35 no.1
    • /
    • pp.10-15
    • /
    • 2024
  • Purpose: This study aimed to comprehensively investigate the diverse characteristics of a novel commercial bolus, CLEANBOLUS-WHITE (CBW), to ascertain its suitability for clinical application. Methods: The evaluation of CBW encompassed both physical and biological assessments. Physical parameters such as mass density and shore hardness were measured alongside analyses of element composition. Biological evaluations included assessments for skin irritation and cytotoxicity. Dosimetric properties were examined by calculating surface dose and beam quality using a treatment planning system (TPS). Additionally, doses were measured at maximum and reference depths, and the results were compared with those obtained using a solid water phantom. The effect of air gap on dose measurement was also investigated by comparing measured doses on the RANDO phantom, under the bolus, with doses calculated from the TPS. Results: Biological evaluation confirmed that CBW is non-cytotoxic, nonirritant, and non-sensitizing. The bolus exhibited a mass density of 1.02 g/cm3 and 14 shore 00. Dosimetric evaluations revealed that using the 0.5 cm CBW resulted in less than a 1% difference compared to using the solid water phantom. Furthermore, beam quality calculations in the TPS indicated increased surface dose with the bolus. The air gap effect on dose measurement was deemed negligible, with a difference of approximately 1% between calculated and measured doses, aligning with measurement uncertainty. Conclusions: CBW demonstrates outstanding properties for clinical utilization. The dosimetric evaluation underscores a strong agreement between calculated and measured doses, validating its reliability in both planning and clinical settings.

Dosimetric Characteristics of a Thermal Neutron Beam Facility for Neutron Capture Therapy at HANARO Reactor (하나로 원자로 BNCT 열중성자 조사장치에 대한 선량특성연구)

  • Lee, Dong-Han;Suh, So-Heigh;Ji, Young-Hoon;Choi, Moon-Sik;Park, Jae-Hong;Kim, Kum-Bae;Yoo, Seung-Yul;Kim, Myong-Seop;Lee, Byung-Chul;Chun, Ki-Jung;Cho, Jae-Won;Kim, Mi-Sook
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.87-92
    • /
    • 2007
  • A thermal neutron beam facility utilizing a typical tangential beam port for Neutron Capture Therapy was installed at the HANARO, 30 MW multi-purpose research reactor. Mixed beams with different physical characteristics and relative biological effectiveness would be emitted from the BNCT irradiation facility, so a quantitative analysis of each component of the mixed beams should be performed to determine the accurate delivered dose. Thus, various techniques were applied including the use of activation foils, TLDs and ionization chambers. All the dose measurements were perform ed with the water phantom filled with distilled water. The results of the measurement were compared with MCNP4B calculation. The thermal neutron fluxes were $1.02E9n/cm^2{\cdot}s\;and\;6.07E8n/cm^2{\cdot}s$ at 10 and 20 mm depth respectively, and the fast neutron dose rate was insignificant as 0.11 Gy/hr at 10 mm depth in water The gamma-ray dose rate was 5.10 Gy/hr at 20 mm depth in water Good agreement within 5%, has been obtained between the measured dose and the calculated dose using MCNP for neutron and gamma component and discrepancy with 14% for fast neutron flux Considering the difficulty of neutron detection, the current study support the reliability of these results and confirmed the suitability of the thermal neutron beam as a dosimetric data for BNCT clinical trials.

  • PDF

Suggestion for a New Grading Scale for Radiation Induced Pneumonitis Based on Radiological Findings of Computerized Tomography: Correlation with Clinical and Radiotherapeutic Parameters in Lung Cancer Patients

  • Kouloulias, Vassilios;Zygogianni, Anna;Efstathopoulos, Efstathios;Victoria, Oikonomopoulou;Christos, Antypas;Pantelis, Karaiskos;Koutoulidis, Vassilios;Kouvaris, John;Sandilos, Panagiotis;Varela, Maria;Aytas, Ilknur;Gouliamos, Athanasios;Kelekis, Nikolaos
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.2717-2722
    • /
    • 2013
  • Background: The objective of this research is the computed axial tomography (CT) imaging grading of radiation induced pneumonitis (RP) and its correlation with clinical and radiotherapeutic parameters. Materials and Methods: The chest CT films of 20 patients with non-small cell lung cancer who have undergone threedimensional conformal radiation therapy were reviewed. The proposed CT grading of RP is supported on solely radiological diagnosis criteria and distinguishes five grades. The manifestation of RP was also correlated with any positive pre-existing chronic obstructive pulmonary disease (COPD) history, smoking history, the FEV1 value, and the dosimetric variable V20. Results: The CT grading of RP was as follows: 3 patients (15%) presented with ground glass opacity (grade 1), 9 patients (45%) were classified as grade 2, 7 patients (35%) presented with focal consolidation, with or without elements of fibrosis (grade 3), and only one patient (5%) presented with opacity with accompanying atelectasis and loss of pulmonary volume (grade 4). Both univariate and multivariate analysis revealed as prognostic factors for the radiological grading of RP the reduction of FEV1 and the V20 (P=0.026 and P=0.003, respectively). There was also a significant (P<0.001) correlation of radiological grading of RP with FEV1 and V20 (spearman rho 0.92 and 0.93, respectively). Conclusions: The high correlation of the proposed radiological grading with the FEV1 and the V20 is giving a satisfactory clinical validity. Although the proposed grading scale seems relevant to clinical practice, further studies are needed for the confirmation of its validity and reliability.