• 제목/요약/키워드: Dosimetric

검색결과 335건 처리시간 0.02초

Dosimetric Evaluation of Low-Dose Spillage Volumes for Head and Neck Cancer Using Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Treatment Techniques

  • Kumar, Gourav;Bhushan, Manindra;Kumar, Lalit;Kishore, Vimal;Raman, Kothanda;Kumar, Pawan;Barik, Soumitra;Purohit, Sandeep
    • 한국의학물리학회지:의학물리
    • /
    • 제32권3호
    • /
    • pp.70-81
    • /
    • 2021
  • Purpose: This study was designed to investigate the dosimetric difference between intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) in head and neck cancer (HNC). The study primarily focuses on low-dose spillage evaluation between these two techniques. Methods: This retrospective study involved 45 patients with HNC. The treatment plans were generated using the IMRT and VMAT techniques for all patients. Dosimetric comparisons were performed in terms of target coverage, organ-at-risk (OAR) sparing, and various parameters, including conformity index, uniformity index, homogeneity index, conformation number, low-dose volumes, and normal tissue integral dose (NTID). Results: No significant (P>0.05) difference in planning target volume coverage (D95%) was observed between IMRT and VMAT plans for supraglottic larynx, hard palate, and tongue cancers. A decrease in dose volumes ranging from 1 Gy to 30 Gy was observed for VMAT plans compared with those for IMRT plans, except for V1Gy and V30Gy for supraglottic larynx cancer and V1Gy for tongue cancer. Moreover, decreases (P<0.05) in NTID were observed for VMAT plans compared with that for IMRT plans in supraglottic larynx (4.50%), hard palate (12.80%), and tongue (7.76%) cancers. In contrast, a slight increase in monitor units for VMAT compared with those for IMRT in supraglottic larynx (0.46%), hard palate (2.54%), and tongue (7.56%) cancers. Conclusions: For advanced-stage HNC, both IMRT and VMAT offer satisfactory clinical plans. VMAT offers a conformal and homogeneous dose distribution with comparable OAR sparing and higher dose falloff outside the target volume than IMRT, which provides an edge to reduce the risk of secondary malignancies for HNC over IMRT.

Dosimetric Evaluation of 3-D Conformal and Intensity-modulated Radiotherapy for Breast Cancer after Conservative Surgery

  • Mansouri, Safae;Naim, Asmaa;Glaria, Luis;Marsiglia, Hugo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권11호
    • /
    • pp.4727-4732
    • /
    • 2014
  • Background: Breast cancers are becoming more frequently diagnosed at early stages with improved long term outcomes. Late normal tissue complications induced by radiotherapy must be avoided with new breast radiotherapy techniques being developed. The aim of the study was to compare dosimetric parameters of planning target volume (PTV) and organs at risk between conformal (CRT) and intensity-modulated radiation therapy (IMRT) after breast-conserving surgery. Materials and Methods: A total of 20 patients with early stage left breast cancer received adjuvant radiotherapy after conservative surgery, 10 by 3D-CRT and 10 by IMRT, with a dose of 50 Gy in 25 sessions. Plans were compared according to dose-volume histogram analyses in terms of PTV homogeneity and conformity indices as well as organs at risk dose and volume parameters. Results: The HI and CI of PTV showed no difference between 3D-CRT and IMRT, V95 gave 9.8% coverage for 3D-CRT versus 99% for IMRT, V107 volumes were recorded 11% and 1.3%, respectively. Tangential beam IMRT increased volume of ipsilateral lung V5 average of 90%, ipsilateral V20 lung volume was 13%, 19% with IMRT and 3D-CRT respectively. Patients treated with IMRT, heart volume encompassed by 60% isodose (30 Gy) reduced by average 42% (4% versus 7% with 3D-CRT), mean heart dose by average 35% (495cGy versus 1400 cGy with 3D-CRT). In IMRT minimal heart dose average is 356 cGy versus 90cGy in 3D-CRT. Conclusions: IMRT reduces irradiated volumes of heart and ipsilateral lung in high-dose areas but increases irradiated volumes in low-dose areas in breast cancer patients treated on the left side.

인체 착용형 휴대 단말기에 대한 노출량 해석 연구 (Dosimetric Analysis for Human Exposure to Body-Mounted Wireless Devices)

  • 박민영;고채옥;김정란;백정기
    • 한국전자파학회논문지
    • /
    • 제17권2호
    • /
    • pp.207-212
    • /
    • 2006
  • 현재 다양한 종류의 무선 단말기가 상용화 되어 있다. 그러나 연구의 대부분이 휴대폰에 의한 생체 영향에만 국한되어 있는 실정이다. 본 논문에서는 두부 착용형과 손목 착용형 같은 인체 착용형 단말기에 대한 인체 영향을 분석하였다. 외국인 성인 모델과 한국인 성인 모델 그리고 외국인 청소년 모델을 대상으로 FDTD 기법을 적용하여 SAR을 계산하였다. 또한 시뮬레이션 결과를 검증하기 위해 간단한 구조의 head-mounted display 장치에 대한 노출량을 SAM 팬텀을 이용하여 측정하였다. 노출량 평가 결과 인체 착용형 단말기 노출에 대해 어린이가 더 취약한 것으로 나타났으며 이러한 기기가 휴대폰에 비해 출력이 상대적으로 낮음에도 불구하고 인체에 영향을 미칠 수도 있는 것으로 평가되었다.

The Properties of Beam Intensity Scanner(BInS) in IMRT with Phantom for Three Dimensional Dose Verification

  • Young W. Vahc;Park, Kwangyl;Byung Y. Yi;Park, Kyung R.;Lee, Jong Y.;Ohyun Kwon;Park, Kwangyl;Kim, Keun M.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.64-64
    • /
    • 2003
  • Objectives: Patient dose verification is clinically the most important parts in the treatment delivery of radiation therapy. The three dimensional(3D) reconstruction of dose distribution delivered to target volume helps to verify patient dose and determine the physical characteristics of beams used in intensity modulated radiation therapy(IMRT). We present Beam Intensity Scanner(BInS) system for the pre treatment dosimetric verification of two dimensional photon intensity. The BInS is a radiation detector with a custom made software for relative dose conversion of fluorescence signals from scintillator. Methods: This scintillator is fabricated by phosphor Gadolinium Oxysulphide and is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The digitized fluoroscopic signals obtained by digital video camera will be processed by our custom made software to reproduce 3D relative dose distribution. For the intensity modulated beam(IMB), the BInS calculates absorbed dose in absolute beam fluence, which are used for the patient dose distribution. Results: Using BInS, we performed various measurements related to IMRT and found the followings: (1) The 3D dose profiles of the IMBs measured by the BInS demonstrate good agreement with radiographic film, pin type ionization chamber and Monte Carlo simulation. (2) The delivered beam intensity is altered by the mechanical and dosimetric properties of the collimating of dynamic and/or static MLC system. This is mostly due to leaf transmission, leaf penumbra, scattered photons from the round edges of leaves, and geometry of leaf. (3) The delivered dose depends on the operational detail of how to make multileaf opening. Conclusions: These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planing for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

Proposal on Guideline for Quality Assurance of Radiation Treatment Planning System

  • Oh, Yoonjin;Shin, Dong Oh;Kim, Juhye;Kwon, Nahye;Lee, Soon Sung;Choi, Sang Hyoun;Ahn, Sohyun;Park, Dong-wook;Kim, Dong Wook
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.197-206
    • /
    • 2017
  • We develop guidelines for the quality assurance of radiation treatment planning systems (TPS) by comparing and reviewing recommendations from major countries and organizations, as well as by analyzing the AAPM, ESTRO, and IAEA TPS quality assurance guidelines. We establish quality assurance items for acceptance testing, commissioning, periodic testing, system management, and security, and propose methods to perform each item within acceptable standards. Acceptance includes tests of hardware and network environments, data transmission, software, and benchmarking as specified by the system supplier, and apply the IAEA classification criteria. Commissioning includes dosimetric and non-dosimetric items for assessing TPS performance by applying the AAPM classification criteria and the latest technical items from the IAEA. Periodic quality assurance tests include daily, weekly, monthly, yearly, and occasional items by applying the AAPM classification criteria. System management and security items include the state and network connectivity of TPS, periodic data backup, and data access security. The guidelines for TPS quality assurance proposed in this study will help to improve the safety and quality of radiotherapy by preventing incidents related to radiotherapy.

Novel Dosimeter for Low-Dose Radiation Using Escherichia coli PQ37

  • Park, Seo-Hyoung;Kim, Tae-Hwan;Cho, Chul-Koo;Lee, Yeon-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권3호
    • /
    • pp.524-528
    • /
    • 2001
  • The measurement of radiation response using simple and informative techniques would be of great value in studying the genetic risk following occupational, therapeutic, or accidental exposure to radiation. When patients receive radiation therapy, many suffer from side effects. Since each patient receives a different dose due to different physical conditions, it is important to measure the exact dose of radiation received by each patient to lessen the side effects. Even though several biological dosimetric systems have already been developed, there is no ideal system that can satisfy all the criteria for an idean dosimetric system, especially for low-dose radiation as used in radiation therapy. In this study, an SOS Chromotest of E. coli PQ37 was evaluated as a novel dosimeter for low-dose gamma-rays. E. coli PQ37 was originally developed to screen chemical mutagens using the SOS Chromotest-a colorimtric assay, based on the induction of ${\beta}$-galactosidase ue to DNA damage. The survival fraction of E. coli PQ37 decreased dose-dependently with an increasing dose of cobalt-60 gamma-rays. Also, a good linear correlation was found between the biological damage revealed by the ${\beta}$-galactosidase expression and the doses of gamma-rays. The expression of ${\beta}$-galactosidase activity that responded to low-dose radiation under 1 Gy was $Y=0.404+(0.089{\pm}0.3)D+(-0.018{\pm}0.16)D^2$ (Y, absorbance at 420 nm; D, Dose of irradiation) as calculated using Graph Pad In Plot and Excel. When a rabbit was fed with capsules containing an agar block embdded with E. coli PQ37 showed a linear response to the radiation doses. Accordingly, the results confirm that E. coli PQ37 can be used as a sensitive biological dosimeter fro cobalt-60 gamma-rays. To the best of our knowledge, this is the first time that a bacterium has been used as a biological dosimeter, especially for low-dose radiation.

  • PDF