• 제목/요약/키워드: Dosimetric

검색결과 338건 처리시간 0.024초

Determination of dosimetric dependence for effective atomic number of LDR brachytherapy seed capsule by Monte Carlo simulation

  • Berkay Camgoz;Dilara Tarim
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2734-2741
    • /
    • 2023
  • Brachytherapy is a special case of radiotherapy. It should be arranged according to some principles in medical radiation applications and radiation physics. The primary principle is to use as low as reasonably achievable dose in all ionizing radiation applications for diagnostic and therapeutic treatments. Dosimetric distributions are dependent on radioactive source properties and radiation-matter interactions in an absorber medium such as phantom or tissue. In this consideration, the geometrical structure and material of the seed capsule, which surrounds a radioactive material, are directly responsible for isodose profiles and dosimetric functions. In this study, the radiometric properties of capsule material were investigated on dose distribution in a water phantom by changing its nuclear properties using the EGSnrc Monte Carlo (MC) simulation code. Effective atomic numbers of hypothetic mixtures were calculated by using different elements with several fractions for capsule material. Model 6711 brachytherapy seed was modeled by EGSnrc/Dosrcnrc Code and dosimetric functions were calculated. As a result, dosimetric parameters of hypothetic sources have been acquired in large-scale atomic number. Dosimetric deviations between the data of hypothetic seeds and the original one were analyzed. Unit dose (Gy/Particle) distributions belonging to different types of material in seed capsule have remarkably differed from the original capsule's data. Capsule type is major variable to manage the expected dose profile and isodose distribution around a seed. This study shows us systematically varied scale of material type (cross section or effective atomic number dependent) offers selective material usage in production of seed capsules for the expected isodose profile of a specific source.

Dosimetric Verification for Primary Focal Hypermetabolism of Nasopharyngeal Carcinoma Patients Treated with Dynamic Intensity-modulated Radiation Therapy

  • Xin, Yong;Wang, Jia-Yang;Li, Liang;Tang, Tian-You;Liu, Gui-Hong;Wang, Jian-She;Xu, Yu-Mei;Chen, Yong;Zhang, Long-Zhen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권3호
    • /
    • pp.985-989
    • /
    • 2012
  • Objective: To make sure the feasibility with $^{18F}FDG$ PET/CT to guided dynamic intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma patients, by dosimetric verification before treatment. Methods: Chose 11 patients in III~IVA nasopharyngeal carcinoma treated with functional image-guided IMRT and absolute and relative dosimetric verification by Varian 23EX LA, ionization chamber, 2DICA of I'mRT Matrixx and IBA detachable phantom. Drawing outline and making treatment plan were by different imaging techniques (CT and $^{18F}FDG$ PET/CT). The dose distributions of the various regional were realized by SMART. Results: The absolute mean errors of interest area were $2.39%{\pm}0.66$ using 0.6cc ice chamber. Results using DTA method, the average relative dose measurements within our protocol (3%, 3 mm) were 87.64% at 300 MU/min in all filed. Conclusions: Dosimetric verification before IMRT is obligatory and necessary. Ionization chamber and 2DICA of I'mRT Matrixx was the effective dosimetric verification tool for primary focal hyper metabolism in functional image-guided dynamic IMRT for nasopharyngeal carcinoma. Our preliminary evidence indicates that functional image-guided dynamic IMRT is feasible.

Mantle Field에서 Lung Block의 선량분포 고려 (Dosimetric Consideration of the Lung Block in the Mantle Field)

  • 유명진;신병철;문창우;정태식;염하용
    • Radiation Oncology Journal
    • /
    • 제13권2호
    • /
    • pp.199-203
    • /
    • 1995
  • Purpose: To evaluate the dose under lung block as a function of depth and the effectiveness of a block as a function of block width. Materials and Methods : Field size of mantle field was $22.8{\times}32.4cm^2.$ Dose distribution of the mantle field was measured with two dimensional water phantom system. To analyze the effectiveness of the lung block. central axis plane, 5cm off-axis plane, and 10cm off-axis plane were studied. Results: The dose under the lung block was recorded with maximum at the depth between 5cm and 10cm. In the central axis plane, dosimetric block width was $10-15\%$ less than physical block width. In the 5cm off-axis plane, dosimetric block width was $4-9\%$ less than physical block width. In the 10cm off-axis plane, dosimetric block width was $2\%$ less than physical block width. Conclusion: Depth dependence of the dose under the lung block was founded. Also, block width dependence of the lung block was founded. To induce the accurate relation between the physical block width and the 'effective' block width, it needs more detailed understanding of the variables involved.

  • PDF

Independent jaw를 이용한 비대칭조사면의 선량분포에 관한 연구 (Dosimetric characteristics of an independent collimator system using measurements performed quarter fields.)

  • 김건오;정세영;김영범;권영호
    • 대한방사선치료학회지
    • /
    • 제14권1호
    • /
    • pp.109-116
    • /
    • 2002
  • The mordem linear accelerators are equipped with X-ray collimators that can be moved independently to allow asymmetric fields with field centers positioned away from the true central axis of the beam. We have studied the dosimetric of an independent collimator system using measurements performed quarter fields. The field size factors for asymmetric fields are compared to those for symmetric fields. Dosimetric measurements include portent depth don, beam penumbra and shape of isodose curves for symmetric and quarter fields.

  • PDF

RF 전자기장 생체 영향 실험에서 통계적 방법을 통한 전자기장 노출 불확실성 분석 (The analysis of RF dosimetric uncertainties by using statistical method at in-vivo and in-vitro experiments)

  • 최성호;김남
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.74-78
    • /
    • 2003
  • This paper shows the dosimetric uncertainties of electromagnetic field at in-vivo and in-vitro experiments. For more accurate consequences of these researches, we have tried to find out any correlations among output power, power density and specific absorption rate(SAR) with the results of in-vivo, in-vitro tests and SAR reports of cellular phone and PDA. In the case of in-vivo tests, the power density has close statistical correlations with SAR value and in the event of in-vitro tests, the output power has considerable statistical correlations with SAR containing duty factor. On the other hand, we found that both power density and output power don't have any close correlations with SAR. And, we obtained fitted regression form among frequency, power density and SAR containing duty factor through multiple linear regression analysis.

  • PDF

4MV 선형가속기에서의 비대칭 콜리메이터의 선량측정 (Dosimetric Measurement for 4MV X-Ray Linear Accelerator with Asymmetric Collimator System)

  • 이병용;최은경;장혜숙
    • 한국의학물리학회지:의학물리
    • /
    • 제1권1호
    • /
    • pp.69-73
    • /
    • 1990
  • Dosimetric measurement of an asymmetric collimator system was performed, using water phantom system for 4MV X-ray linear accelerator. We have studied the system of dose calculation with those measured result. We compared the field size factor and the percent depth dose for asymmetric collimator to those factor for symmetric fields. The results show that we can use symmetric field data directly within 1% error, if we consider the off axis ratio(OAR).

  • PDF

Dosimetric comparison of volumetric modulated arc therapy with robotic stereotactic radiation therapy in hepatocellular carcinoma

  • Paik, Eun Kyung;Kim, Mi-Sook;Choi, Chul Won;Jang, Won Il;Lee, Sung Hyun;Choi, Sang Hyoun;Kim, Kum Bae;Lee, Dong Han
    • Radiation Oncology Journal
    • /
    • 제33권3호
    • /
    • pp.233-241
    • /
    • 2015
  • Purpose: To compare volumetric modulated arc therapy of RapidArc with robotic stereotactic body radiation therapy (SBRT) of CyberKnife in the planning and delivery of SBRT for hepatocellular carcinoma (HCC) treatment by analyzing dosimetric parameters. Materials and Methods: Two radiation treatment plans were generated for 29 HCC patients, one using Eclipse for the RapidArc plan and the other using Multiplan for the CyberKnife plan. The prescription dose was 60 Gy in 3 fractions. The dosimetric parameters of planning target volume (PTV) coverage and normal tissue sparing in the RapidArc and the CyberKnife plans were analyzed. Results: The conformity index was $1.05{\pm}0.02$ for the CyberKnife plan, and $1.13{\pm}0.10$ for the RapidArc plan. The homogeneity index was $1.23{\pm}0.01$ for the CyberKnife plan, and $1.10{\pm}0.03$ for the RapidArc plan. For the normal liver, there were significant differences between the two plans in the low-dose regions of $V_1$ and $V_3$. The normalized volumes of $V_{60}$ for the normal liver in the RapidArc plan were drastically increased when the mean dose of the PTVs in RapidArc plan is equivalent to the mean dose of the PTVs in the CyberKnife plan. Conclusion: CyberKnife plans show greater dose conformity, especially in small-sized tumors, while RapidArc plans show good dosimetric distribution of low dose sparing in the normal liver and body.

표준 전자선 cone의 확장된 SSD에서의 선량평가 및 자체제작한 전자선 cone의 특성 (The Dosimetric evaluation of the standard electron cone for the extended cone for the extended SSD and The Dosimetric characteristics of the custom-made electron cone)

  • 정세영;정희영;김영범;권영호
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.73-78
    • /
    • 1999
  • In general, the patients of the head and neck cancer are treated with 4MV photon beam up to prescribed dose, but spinal cord should be excluded in the treatment field. When its absorbed dose is limited at the tolerance dose. In case of the patients who has the positive posterior neck nodes need a boost electron beam treatment to the prescribed dose. In that case, the anatomical structure of the neck and the physical structure of the standard electron cone interrupt to allow proper access to the disease site. Therefore, we extended treatment SSD for the remove of the those hindrances. In this study, we evaluated the dosimetric variation of the standard electron cone for the extended SSD, from 100cm to 120cm, 5 cm increment, and compare to the custom-made electron cone. As a result, the $\%$ depth dose, the point of maximum dose and the range of maximum were changed within the $2\%$. The penumbra width was increased from 1.0cm to 2.0cm. However, the dosimetric characteristics of the custom-made electron cone was very similar to that of the 100cm SSD standard electron cone and due to its characteristic of physical structure, patients didn't need re-positioning after photon beam treatment, therefore accurate treatment was possible, we conclude that the custom-made electron cone was very useful for the clinical practice.

  • PDF

방사선 선량의 표준 측정법(한국의학물리학회 1990) 및 TG-21, $C_{\lambda}/C_E$ 방법의 비교 (The Comparison of the KAPM Dosimetric Protocol (1990) with the TG-21 and $C_{\lambda}/C_E$ Method)

  • 이병용;최은경;장혜숙
    • Radiation Oncology Journal
    • /
    • 제9권2호
    • /
    • pp.337-342
    • /
    • 1991
  • 방사선 선량의 표준측정법 (한국의학 물리학회 1990) 및 TG-21, $C_{\lambda}/C_E$ 방법을 비교 연구하였다. 방사선 치료에서 사용되는 광자선과(4MV-l5MV) 전자선(6MeV-20MeV)을 세 종류의 전리함으로 물팬틈속에서 측정, 평가한 결과를 비교하였다. TG-21과 방사선 선량의 표준 측정법 비교에서는1$\%$ 이내의 작은 차이만을 보여주었으며 그 차이는 주로 $N_{D}-N_{gas}$ 차이에서 나오는 것으로 평가되었다. 그러나 $C_{\lambda}/C_E$ 방법과의 비교에서는 광자선의 경우 $-1.9{\pm}0.6\%$ (방사선 선량의 표준 측정에 의한 결과가 높게 나옴) 전자선의 경우 $3.3{\pm}1\%$(방사선 선량의 표준측정법에 의한 결과가 낮게 나옴)의 차이를 보였다.

  • PDF

Dosimetric Comparison of Noncoplanar and Coplanar Volumetric Modulated Arc Therapy Plans for Esophageal Cancer

  • Park, So-Yeon
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.179-188
    • /
    • 2020
  • Purpose: We compared noncoplanar volumetric modulated arc therapy (ncVMAT) plans to coplanar VMAT (cVMAT) plans by evaluating the dosimetric quality of each for esophageal cancer. Methods: Twenty patients treated for esophageal cancer with the cVMAT technique were retrospectively selected. The cVMAT plans consisted of three coplanar full arc beams. The ncVMAT plans consisted of two coplanar full arc beams and one noncoplanar partial arc beam ranging from 45° to 315° with a couch rotation angle of 315°±5°. For dosimetric evaluation, the dose-volumetric (DV) parameters of the planning target volume (PTV) and organs at risk (OARs) were calculated for all VMAT plans. Results: No clinically noticeable differences between the cVMAT and ncVMAT plans were observed in the DV parameters of the PTV. For the lungs, the V13 Gy and mean dose for ncVMAT plans were smaller than those for cVMAT plans, showing statistically significant differences. For the heart, the values of the maximum dose for cVMAT and ncVMAT plans were 53.8±2.9 and 50.9±3.3 Gy, respectively (P=0.004). For the spinal cord, the values of the maximum dose for cVMAT and ncVMAT plans were 37.1±5.1 and 34.7±5.7 Gy, respectively (P<0.001). Conclusions: The use of ncVMAT plans provides better PTV coverage and sparing of OARs compared to that of cVMAT plans for long, tube-like esophageal cancer. For esophageal cancer, the ncVMAT plans showed a more favorable plan quality than the cVMAT plans.