• 제목/요약/키워드: Dose-volumetric parameters

검색결과 30건 처리시간 0.029초

Morphological Factors and Cardiac Doses in Whole Breast Radiation for Left-sided Breast Cancer

  • Guan, Hui;Dong, Yuan-Li;Ding, Li-Jie;Zhang, Zi-Cheng;Huang, Wei;Liu, Cheng-Xin;Fu, Cheng-Rui;Zhu, Jian;Li, Hong-Sheng;Li, Miao-Miao;Li, Bao-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권7호
    • /
    • pp.2889-2894
    • /
    • 2015
  • Background: To investigate the impact of the breast size, shape, maximum heart depth (MDH), and chest wall hypotenuse (the distance connecting middle point of the sternum and the length of lung draw on the selected transverse CT slice) on the volumetric dose to heart with whole breast irradiation (WBI) of left-sided breast cancer patients. Materials and Methods: Fifty-three patients with left-sided breast cancer undergoing adjuvant intensity-modulated radiotherapy (IMRT) were enrolled in the study. The primary breast size and shape, MHD and DCWH (chest wall hypotenuse) were contoured on radiotherapy (RT) planning CT slices. The dose data of hearts were obtained from the dose-volume histograms (DVHs). Data were analyzed by one-way analysis of variance (ANOVA), Student's t-test and linear regression analysis. Results: Breast size was independent of heart dose, whereas breast shape, MHD and DCWH were correlated with heart dose. The shapes of breasts were divided into four types, as the flap type, hemisphere type, cone type and pendulous type with heart mean dose being $491.8{\pm}234.6cGy$, $752.7{\pm}219.0cGy$, $620.2{\pm}275.7cGy$, and $666.1{\pm}238.0cGy$, respectively. The flap type of breasts shows a strong statistically reduction in heart dose, compared to others (p=0.008 for V30 of heart). DCWH and MHD were found to be the most important parameters correlating with heart dose in WBI. Conclusions: More attention should be paid to the heart dose of non-flap type patients. The MHD was found to be the most important parameter to correlate with heart dose in tangential WBI, closely followed by the DCWH, which could help radiation oncologists and physicsts evaluate heart dose and design RT plan in advance.

뇌암 및 두경부암 체적변조방사선치료시 Jaw-Tracking 기법의 선량학적 유용성 평가 (Evaluation of the Jaw-Tracking Technique for Volume-Modulated Radiation Therapy in Brain Cancer and Head and Neck Cancer)

  • 김희성;문재희;김군주;서정민;이정진;최재훈;김성기;장인기
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.177-183
    • /
    • 2018
  • 목 적 : 체적변조회전방사선치료(VMAT)는 종양의 모양에 맞게 균일하면서도 정밀한 방사선 조사를 하면서 동시에 정상조직의 방사선 손상위험을 줄이는 장점이 있어 뇌암, 두경부암 및 전립선암 등의 종양과 정상장기가 가까운 암의 치료에 사용되고 있다. 본 연구의 목적은 뇌암 및 두경부암 환자의 VMAT 방사선 치료 시 Jaw-Tracking technique(JTT)의 선량학적 유용성을 평가하고자 한다. 대상 및 방법 : 본원에서 VMAT 치료기법으로 방사선치료를 받은 뇌암 및 두경부암 환자 8명을 선택하였다. 환자의 종양 및 정상 장기의 윤곽그리기(contouring) 정보를 Velocity(Varian, USA)의 deformable registration을 이용하여 Rando phantom에 fusion하였다. Varian Eclipse(ver 15.5, Varian, USA)를 사용하여 Jaw-Tracking 사용 유무를 제외하고 환자 치료 시 사용한 beam parameter와 동일하게 치료계획을 진행하였다. 평가 지표로써 target과 OAR의 최대선량, 평균선량을 사용하여 비교하였고 치료계획 검증을 위해 Portal dosimetry를 시행하였다. 결 과 : JTT를 사용했을 경우는 Static-Jaw technique(SJT)을 사용하였을 경우보다 OAR의 상대 선량이 각각 평균선량은 5.24 %, 최대선량은 7.05 % 감소한 것으로 나타났다. 다양한 OAR에서 평균선량과 최대선량의 감소의 범위는 각각 0.01~3.16 Gy, 0.12~6.27 Gy로 나타났다. Target의 경우는 JTT의 경우가 SJT보다 GTV, CTV, PTV의 최대선량이 각각 0.17 %, 0.43 %, 0.37 % 감소하였으며, 평균선량은 0.24 %, 0.47 %, 0.47% 감소하였다. 감마분석은 3 %/3 mm, 통과율 95 % 이상을 통과 기준으로 설정하였고 JTT, SJT 통과율은 각각 $98{\pm}1.73%$, $97{\pm}1.83%$이었다. 실험에 적용된 모든 OAR의 선량을 비교해 보았을 때, JTT을 사용하였을 경우가 SJT보다 MLC 외에 추가적인 jaw 차폐로 인하여 선량이 유의미하게 줄어들었다는 것을 알 수 있었다. 결 론 : VMAT 치료계획을 이용한 방사선 치료시 뇌암, 두경부암과 같이 종양과 정상 장기가 인접한 경우와 MLC를 통한 누설선량을 증가시킬 수 있는 넓은 조사야 및 높은 에너지의 사용을 필요로 하는 방사선 치료 시 JTT를 적용함으로써 종양주변 정상조직의 피폭선량을 낮추고 이로 인해 PTV의 target coverage를 높일 수 있을 것이라 판단된다.

  • PDF

Dosimetric comparison of axilla and groin radiotherapy techniques for high-risk and locally advanced skin cancer

  • Mattes, Malcolm D.;Zhou, Ying;Berry, Sean L.;Barker, Christopher A.
    • Radiation Oncology Journal
    • /
    • 제34권2호
    • /
    • pp.145-155
    • /
    • 2016
  • Purpose: Radiation therapy targeting axilla and groin lymph nodes improves regional disease control in locally advanced and high-risk skin cancers. However, trials generally used conventional two-dimensional radiotherapy (2D-RT), contributing towards relatively high rates of side effects from treatment. The goal of this study is to determine if three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), or volumetric-modulated arc therapy (VMAT) may improve radiation delivery to the target while avoiding organs at risk in the clinical context of skin cancer regional nodal irradiation. Materials and Methods: Twenty patients with locally advanced/high-risk skin cancers underwent computed tomography simulation. The relevant axilla or groin planning target volumes and organs at risk were delineated using standard definitions. Paired t-tests were used to compare the mean values of several dose-volumetric parameters for each of the 4 techniques. Results: In the axilla, the largest improvement for 3D-CRT compared to 2D-RT was for homogeneity index (13.9 vs. 54.3), at the expense of higher lung $V_{20}$ (28.0% vs. 12.6%). In the groin, the largest improvements for 3D-CRT compared to 2D-RT were for anorectum $D_{max}$ (13.6 vs. 38.9 Gy), bowel $D_{200cc}$ (7.3 vs. 23.1 Gy), femur $D_{50}$ (34.6 vs. 57.2 Gy), and genitalia $D_{max}$ (37.6 vs. 51.1 Gy). IMRT had further improvements compared to 3D-CRT for humerus $D_{mean}$ (16.9 vs. 22.4 Gy), brachial plexus $D_5$ (57.4 vs. 61.3 Gy), bladder $D_5$ (26.8 vs. 36.5 Gy), and femur $D_{50}$ (18.7 vs. 34.6 Gy). Fewer differences were observed between IMRT and VMAT. Conclusion: Compared to 2D-RT and 3D-CRT, IMRT and VMAT had dosimetric advantages in the treatment of nodal regions of skin cancer patients.

중합체 겔 선량측정법을 위한 최적의 자기공명영상 변수에 관한 연구 (A Study of Optimized MRI Parameters for Polymer Gel Dosimetry)

  • 조삼주;정영립;이상훈;허현도;최진호;박성일;심수정;권수일
    • 한국의학물리학회지:의학물리
    • /
    • 제23권2호
    • /
    • pp.71-80
    • /
    • 2012
  • 최신 방사선 치료 및 수술 기법에는 복잡한 3차원적 선량분포를 정확히 측정하는 실용적 선량분석 기기 및 기술이 필요하다. 본 연구에서는 실험실에서 제작한 겔을 방사선 치료 영역에서 선량계로 활용하기 위해 최적화된 자기공명영상 변수 조건에 대해 연구하였다. 이를 위해 각 자기공명영상 획득 조건에서 TE 시간 TR 시간, 영상 두께, 코일 등을 달리하여 조건 별로 획득한 영상을 이용하여 비교 평가하였고, 선량불확도 및 선량 분해능을 도입하여 본 연구에서 찾은 조건에 대해 평가하였다. 8% 젤라틴(300 bloom, Sigma-Aldrich, USA), 8% MAA (Metaacrylic acid, Sigma-Aldrich, USA), 10 mM THPC (tetrakis hydroxymethyl phosphonium, Sigma-Aldrich, USA), 그리고 0.05 mM HQ (Hydroquinone, Sigma-Aldrich, USA) 농도의 조성비를 가진 정상산소 중합체 겔을 실험실에서 합성하였다. 방사선 선량 전달은 Co-60 감마선 조사기 (Theratron-780; AECL, Ottawa, Canada)를 사용하였고 고체 팬텀을 사용하여 중합체 겔에 각각 0, 2, 4, 6, 8, 10, 12, 14 Gy의 선량을 전달하였다. 자기공명영상 장치의 특성상 T2 시간을 얻기 위해서는 fast spin echo 파형을 사용하였다. 일반적으로 Head Coil이 SNR이 Body coil 보다 낮아 선량 불확도가 우수할 것으로 예측하였으나, 일부 문헌에서는 Body coil이 영상 균일도가 우수하다고 하였다. 하지만 본 연구에서는 Head coil이 선량 불확도 및 선량 분해능이 모든 선량 영역에서 Body coil 보다 우수한 것을 확인하였다. TR 시간 연구에서 TR 1,500 ms와 TR 2,000 ms 간의 차이는 선량분해능에서 모두 큰 차이가 없으나 TR 1,500 ms가 조금 낮은 선량 불확도 값을 갖는 것을 보았다. MR 영상 두께가 2.5 mm일 경우 모든 TE 시간에 대해 4 Gy에서 가장 낮은 선량 불확도 값을 가졌다. 특히 TE 12 ms 경우 4 Gy 이후에는 가장 낮은값의 결과를 얻었다. 선량 불확도의 경우 6 Gy까지는 TE 시간에 따른 차이는 없으나 이후에는 TE 12 ms가 가장 나은 결과를 얻었다. 선량 불확도의 겨우 6 Gy까지는 모든 TE 시간에 대해 차이가 미미하나 8 Gy 이상에는 20 ms가 가장 우수한 선량 분해능 값을 가졌다. 선량 분해능 값 역시 NEX 3에서 가장 우수한 값을 가졌고 2 NEX일 때 가장 높은 분해능 값을 가졌다. 본 연구 결과 영상 두께와 NEX의 결과는 영상 두께가 얇은 경우 NEX가 높을수록 우수한 결과를 얻었고 영상 두께가 두꺼워 질수록 NEX가 낮아야 함을 확인했다.

Development of a standardized mucositis and osteoradionecrosis animal model using external radiation

  • Seo, Mi Hyun;Lee, Min Young;Eo, Mi Young;Lee, Suk Keun;Woo, Kyung Mi;Kim, Soung Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권4호
    • /
    • pp.240-249
    • /
    • 2020
  • Objectives: Although the side effects of radiation therapy vary from mucositis to osteomyelitis depending on the dose of radiation therapy, to date, an experimental animal model has not yet been proposed. The aim of this study was to develop an animal model for assessing complications of irradiated bone, especially to quantify the dose of radiation needed to develop a rat model. Materials and Methods: Sixteen Sprague-Dawley rats aged seven weeks with a mean weight of 267.59 g were used. Atraumatic extraction of a right mandibular first molar was performed. At one week after the extraction, the rats were randomized into four groups and received a single dose of external radiation administered to the right lower jaw at a level of 14, 16, 18, or 20 Gy, respectively. Clinical alopecia with body weight changes were compared and bony volumetric analysis with micro-computed tomography (CT), histologic analysis with H&E were performed. Results: The progression of the skin alopecia was different depending on the irradiation dose. Micro-CT parameters including bone volume, bone volume/tissue volume, bone mineral density, and trabecular spaces, showed no significant differences. The progression of osteoradionecrosis (ORN) along with that of inflammation, fibrosis, and bone resorption, was found with increased osteoclast or fibrosis in the radiated group. As the radiation dose increases, osteoclast numbers begin to decrease and osteoclast tends to increase. Osteoclasts respond more sensitively to the radiation dose, and osteoblasts are degraded at doses above 18 Gy. Conclusion: A standardized animal model clinically comparable to ORN of the jaw is a valuable tool that can be used to examine the pathophysiology of the disease and trial any potential treatment modalities. We present a methodology for the use of an experimental rat model that incorporates a guideline regarding radiation dose.

비편평화여과기 빔을 이용한 폐 정위절제방사선치료를 위한 AAA와 Acuros XB 계산 알고리즘의 치료계획 비교 (Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams)

  • 정진범;엄근용;김인아;김재성;이정우;홍세미;김연래;박병문;강상원;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제25권4호
    • /
    • pp.210-217
    • /
    • 2014
  • 이 연구는 비편평화여과기(flattening filter-free, FFF) 빔을 이용한 폐 정위절제방사선치료(stereotactic ablative radiotherapy, SABR)에 대하여 서로 다른 선량계산 알고리즘의 선량적 효과를 조사하였다. SABR를 받은 10명의 폐암 환자를 대상으로하여 평가하였다. 모든 치료계획은 Eclipse 치료계획시스템의 Acuros XB (AXB) 알고리즘을 이용하여 수립되었다. 다른 선량계산 알고리즘과 비교를 위하여, 추가적으로 anisotropic analytic algorithm (AAA) 알고리즘을 적용한 치료계획을 재 수립하였다. 두 알고리즘 평가를 위해서, 치료표적과 손상위험장기의 선량체적히스토그램(dose-volume histogrim, DVH)를 분석하였다. 그리고 기술적 인자로써 계산시간과 총 MU 값을 평가하였다. DVH 비교분석을 통해, PTV의 최대선량은 AXB이 AAA 보다 5.2% 높았으며 최소선량은 4.4% 낮게 나타났다. PTV의 $V_{105%}$에서 7.06%까지 큰 차이를 나타났다. 폐의 최대선량은 AXB 치료계획에서 약간 크게 나타났다. 동측성 폐에 5, 10과 20 Gy 선량이 조사되는 체적은 AAA 보다 AXB에서 더 크게 나타났으나 대측성 폐에 대해서는 거의 비슷하게 나타났다. 척수와 심장에서 최대선량의 차이도 크지 않았다. 계산시간의 경우, AXB가 AAA보다 13.7% 정도 소요시간이 적었고 MU 값은 AXB에서 3.47% 더 많았다. 이 연구의 결과들은 회전조절치료 기법을 포함하여 FFF 빔이 적용된 폐 SABR 치료계획에서 AXB 알고리즘은 선량계산의 정확성과 계산시간의 감소의 장점을 제공할 수 있을 것이다.

Volumetric accuracy of cone-beam computed tomography

  • Park, Cheol-Woo;Kim, Jin-ho;Seo, Yu-Kyeong;Lee, Sae-Rom;Kang, Ju-Hee;Oh, Song-Hee;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제47권3호
    • /
    • pp.165-174
    • /
    • 2017
  • Purpose: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. Materials and Methods: Four geometric objects(cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. Results: The mean VE ranged from -4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. Conclusion: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.

좌측 유방암 방사선 치료 시 치료 기법에 따른 선량적 고찰 (The dosimetric guide of treatment modalities for Left side breast irradiation after conservative surgery)

  • 김태민;문성공;김이지;김세영;박령황;김주호;조정희
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.153-160
    • /
    • 2018
  • 목 적 : 부분절제술 시행 후 좌측 유방암 환자의 방사선 치료 시 적용된 각 방사선 치료 기법 별 선량을 후향적으로 분석하여 정상장기와 종양용적의 선량적 결과를 전형적인 분할치료 선량(EQD2)을 고려한 선량 결과를 도출함으로써 임상적 참고 지표로 활용하고자 한다. 대상 및 방법 : 본원에서 시행한 좌측 유방암 환자 중 부분절제술을 시행한 40명을 대상으로 3가지의 치료기법으로 구분하여 적용하였다. 각 치료법의 총 종양용적과 임상적 표적용적에서 HI(homogeneity index), $D_{95%}$, 그리고 CI(conformity index)값, 그리고 $V_{hot}$ 수치를 도출한 후 치료계획을 평가하였다. 사이버나이프를 이용한 경우 종양용적은 타 기법에서의 고선량 용적과 동일하여 임상적 표적용적는 고려하지 않았다. 정상장기에 대한 평가는 평균선량을 비교하였다. 결 과 : 세가지 치료법의 HI는 3D-CRT, VMAT, RIMRT 모두 큰 차이를 보이지 않았다. 체적조절 호형 방사선치료(VMAT)을 이용한 치료의 경우 임상적 표적용적의 $D_{95%}$의 경우 $95.84{\pm}0.75%$로 3차원 입체조형 방사선 치료(3D-CRT) 치료법에 비해 높은 값을 나타냈다. 총 종양용적의 $D_{95%}$값은 다른 치료법들에 비해 미세하게 높은 결과를 보여줬다. 사이버나이프를 이용한 치료법은 정상장기들에 조사되는 선량이 타 치료법에 비해 현저하게 낮았다. 결 론 : 3D-CRT의 경우 DIBH를 동반하여 치료할 경우 전반적으로 심장을 보호하는데 유용한 치료 기법이며 VMAT의 경우 탁월한 TARGET COVERAGE를 나타내지만 저 선량 영역이 타 기법에 비해 넓은 것을 알 수 있다. 그러나 앞선 두 가지 치료법에서 치료계획 평가를 위한 대부분의 선량적 지표에서 비슷한 값을 보여 치료 계획 결과 및 평가에서는 큰 차이가 없는 것으로 환자의 해부학적 구조나 호흡 조절 가능 유무에 따라 치료기법 선택이 가능할 것으로 사료된다. 사이버나이프를 이용한 치료의 경우 종양용적에 정확한 고 선량을 주며 정상장기 보호에 매우 유용한 치료법이지만 국소부위 치료만 가능한 점, 치료시간이 상대적으로 긴 점, 치료 전 침습적 시술인 금침 삽입술을 해야 하는 제약이 있다.

  • PDF

비인두암 Vertical MLC VMAT plan 유용성 평가 (Evaluating efficiency of Vertical MLC VMAT plan for naso-pharyngeal carcinoma)

  • 채승훈;손상준;이제희
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.127-135
    • /
    • 2021
  • 목 적 : 비인두암 VMAT 치료 시 콜리메이터 각도 273°와 350°를 사용한 2회전 치료계획(Vertical MLC VMAT plan, 이하 VMV plan)과 콜리메이터 각도 20°와 340°를 사용한 2회전 치료계획(Complemental MLC VMAT plan, 이하 CMV plan)과의 비교 분석을 통해 유용성을 평가해 보고자 한다. 대상 및 방법 : 본원에서 VMAT 치료를 받은 비인두암 환자 30명을 대상으로 하였다. 전산화치료계획은 Eclipse, PO, AcurosXB 알고리즘을 이용하였으며, 치료기는 Vital-beam을 사용하였다. 치료계획은 갠트리 회전반경이 각각 360°인 두 개의 회전(Arc)을 6MV를 이용하여 생성하고, 콜리메이터 각도 변화에 의한 영향을 확인하기 위해 273°와 350°로 설정한 VMV plan과 20°와 340°로 설정한 CMV plan을 수립하였다. 선량용적 히스토그램에서 확인 및 산출된 계획표적용적(PTV)과 결정장기(OAR)들의 선량지표들과 변조복잡성지수(MCSv), MU, 치료시간에 대해 기술통계 및 대응표본 t-검정을 실시하였다. 그리고 대상별로 두 치료계획의 MCSv의 차이와 각각의 평가지표들의 차이 간 상관관계가 있는지 확인하기 위해 피어슨의 상관관계 분석을 실시하였다. 결 과 : PTV 평가 지표의 경우, VMV Plan에서 PTV_67.5의 CI가 3.76% 개선되었으며, OAR의 경우 척수(-14.05%)와 뇌 줄기(-9.34%)의 선량감소 효과가 두드러지게 나타났다. 그리고 귀밑샘들(왼쪽 : -5.38%, 오른쪽 : -5.97%)과, 시각기관들(왼쪽 시신경 : -4.88%, 오른쪽 시신경 : -5.80%, 시신경교차 : -6.12%, 왼쪽 수정체 : -6.12%, 오른쪽 수정체 : -5.26%), 청각기관(왼쪽 : -11.74%, 오른쪽 : -12.31%)과 갑상샘(-2.02%)에서의 선량감소효과도 확인할 수가 있었다. 또한 MCSv가 VMV Plan에서 5.31% 높게 나왔으며, MU의 경우에 6.11% 낮은 것으로 나타났다. 그리고 두 치료계획의 MCSv의 차이는 PTV_54의 CI(r=-0.55)의 차이, PTV_48의 CI(r=-0.43)의 차이와 유의한 음(-)의 상관관계를 보였고, 척수(r=0.40), 뇌줄기(r=0.34), 양쪽 침샘들(왼쪽 : r=0.36, 오른쪽 : r=0.37)의 차이와 양(+)의 상관관계를 보였다. 이는 VMV plan의 moluation 복잡성이 CMV plan에 비해 상대적으로 높아 질 때, PTV_54, 48의 CI 개선 및 척수, 뇌줄기, 양쪽침샘들의 선량 감소 효과가 커지는 것을 의미하며, 이러한 분석결과들을 바탕으로 VMV plan의 modulation에 대한 효율성이 CMV plan 보다 크다는 것을 확인할 수 있었다. (위 모든 값에 대해 유의수준은 p<.05) 결 론 : VMV Plan은 CMV plan과 비교하여 MLC가 더 효율적으로 modulation할 수 있도록 함으로써, 치료계획의 질을 향상 시키는데 도움이 될 것이라 사료된다.

직장암 치료 시 치료계획에 따른 선량평가 연구 (A study of the plan dosimetic evaluation on the rectal cancer treatment)

  • 정현학;안범석;김대일;이양훈;이제희
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.171-178
    • /
    • 2016
  • 목 적 : 직장암 방사선 치료 시 대퇴골두의 선량을 최소화하기 위해, 보편적인 치료방법인 3문 입체조형치료계획(3D Conformal radiation therapy)과 5문 입체조형치료계획 그리고 용적변조방사선치료(Volumetric Modulated Arc Therapy, 이하 VMAT) 계획의 유용성을 비교, 평가하고자 한다. 대상 및 방법 : 본원에서 21EX(Varian Medical Systems, USA)를 이용하여 치료 받은 직장암 환자 10명을 대상으로 3문, 5문 입체조형치료계획과 VMAT 전산화치료계획을 각각 세우고 이에 대한 선량분포를 비교분석하였다. 전산화 치료계획은 Eclipse(Ver 10.0.42, Varian, USA)를 이용하였으며, 선량계산을 위해 PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver 10.0.28) 알고리즘을 사용하였다. 3문 치료계획은 6MV POST field 와 15MV LT, RT field를 갠트리 각도 $0^{\circ}$, $270^{\circ}$, $90^{\circ}$로 구성하였고, 5문 치료계획은 6MV POST field와 15MV RAO, RPO, LAO, LPO field를 갠트리 각도 $0^{\circ}$, $95^{\circ}$, $45^{\circ}$, $315^{\circ}$, $265^{\circ}$ 로 환자 체표면을 감싸는 형태로 구성하였다. VMAT 치료계획은 갠트리 회전반경이 $360^{\circ}$인 1개의 ARC를 이용하여 수립하였다. 처방선량은 30회에 걸쳐 직장에 총 선량이 54Gy가 되도록 하였다. VMAT 치료계획시 최적화(Optimization) 과정에서 나타나는 선량 차이의 무작위성을 최소화하기 위하여 2회의 최적화와 선량계산과정을 거쳤으며 처방선량의 100%가 표적용적의 95%를 포함할 수 있도록 Plan normalization을 조절하였다. 각 치료 계획의 Total MU, 대퇴골두와 acetabular fossa의 최대선량, PTV의 H.I. (Homogeneity Index), C.I.(Conformity Index)를 평가 지표로 설정하였고, 전자영상유도장치를 이용하여 임상 적용 가능 여부 확인을 위한 IMRT verification Q.A. (Gamma test)를 실시하였다. 결 과 : Rt. femoral head 최대선량은 3문, 5문, VMAT 치료계획 순으로 평균 53.08 Gy, 50.27 Gy, 30.92 Gy를 나타냈다. 마찬가지로 Lt. femoral head 에서도 같은 순으로 평균 53.68 Gy, 51.01 Gy, 평균 29.23 Gy를 나타냈다. Rt. Aceta fossa 의 최대선량은 3문, 5문, VMAT 치료계획 순으로 평균 54.86 Gy, 52.40 Gy, 30.37 Gy의 값을 보였다. Lt. Aceta fossa에서 또한 같은 순으로 평균 54.90 Gy, 52.77 Gy, 평균 31.79 Gy를 나타내어, both femoral head 와 aceta fossa의 최대선량이 3문, 5문, VMAT 치료계획 순으로 높았다. PTV에 대한 H.I.는 모두 서로 비슷한 결과를 나타냈고, C.I.는 3문, 5문, VMAT 치료계획 순으로 평균 1.64, 1.48, 평균 0.99로 VMAT 치료계획이 가장 낮은 것으로 나타났다. Total MU는 VMAT 치료계획이 3문과 5문 치료계획에 비해 각각 평균 124.4MU, 299MU 더 많이 사용하는 것으로 나타났다. VMAT 치료계획에 대한 IMRT verification Q.A. 결과 2mm / 2%, Gamma pass rate 90.0% 기준을 모두 초과하여 통과하였다. 결 론 : VMAT 치료계획은 3D 치료계획과 비교하여 대부분의 평가지표에서 우수한 것으로 나타났다. 특히 대퇴골두의 선량을 크게 감소 시켰으며, 저선량 영역에서는 소장이 받는 선량이 증가 하였으나 오히려 고선량 영역에서는 우수한 선량분포를 보였다. 하지만 VMAT을 지원하지 않는 장비와 치료계획 시 추가되는 Contouring, 그리고 정도관리에 관한 수고 등의 현실적인 제약 때문에 VMAT 치료계획을 선택하기 어려운 경우가 있을 수 있다. 5문 치료계획은 기존 3문 치료계획에 비해, 추가적인 문제에 구애받지 않고 대퇴골두의 선량을 줄일 수 있는 장점이 있다. 따라서 각 병원 상황에 맞게 치료계획을 선택하여 방사선 치료 효과를 높인다면, 직장암 환자의 효율적인 방사선치료 및 생존 기간의 연장뿐만 아니라 삶의 질 향상에도 도움이 될 것으로 판단한다.

  • PDF