• Title/Summary/Keyword: Dose verification

Search Result 224, Processing Time 0.021 seconds

A study on the accuracy of source position in HDR brachytherapy according to the curvature of Universal applicator transfer tube and applicator type (원격 후 장전치료기를 사용한 고선량률 근접치료시 기구의 형태와 선원 전달 도관의 곡률 변화에 따른 선원위치 정확성에 관한 고찰)

  • Shin, Hyeon Kyung;Lee, Sang Kyoo;Kim, Joo Ho;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • Purpose : The goal of this study was to verify and analyze the source position according to the curvature of the universal applicator and 4 different angle applicators when using RALS(Remote After Loading System). Materials and Methods : An interval of 1 cm and 15 second dwell times in each source position were applied for plan. To verify the accuracy of source position, we narrowed the distance between MultiSource container and GAFCHROMIC$^{(R)}$ EBT3 film by 5 cm, 10 cm, 20 cm so that the universal applicator transfer tube had some curvature. Also 4 applicators(Intrauterine tube: $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, Ovoid tube: $65^{\circ}$) were used in the same condition. The differences between desired and actual source position were measured by using Image J. Results : In case of using 4 different angles of applicator with the straight universal applicator transfer tube, the average error was the lowest for $0^{\circ}$ applicator, greatest for $65^{\circ}$ applicator. However, All average errors were within ${\pm}2mm$ recommended in TG-56. When MultiSource container was moved 5 cm, 10 cm, 20 cm towards the EBT3 film, the average errors were beyond ${\pm}2mm$. The first dwell position was relatively located in accuracy, while the second and third dwells were displaced by an increasing magnitude with increasing curvature of the transfer tube. Furthermore, with increasing the angle of applicators, the error of all other dwell positioning was increased. Conclusion : The results of this study showed that both the curvature of universal applicator transfer tube and the angle of applicators affect the source dwell position. It is recommended that using straight universal applicator transfer tubes is followed in all cases, in order to avoid deviations in the delivered source dwell position. Also, It is advisable to verify the actual dwell position, using video camera quality control tool prior to all treatments.

  • PDF

Effects of Crormakalim on the Release of Mediators in Hypersensitivity of Guinea pig (Cromakalim이 해명의 과민반응 매개체 유리에 미치는 영향)

  • Ro, Jai-Youl;Kim, Kyung-Hwan
    • The Korean Journal of Pharmacology
    • /
    • v.29 no.2
    • /
    • pp.263-274
    • /
    • 1993
  • Potassium $(K^+)$ channels are present in airway smooth muscle cells, and their activation results in hyperpolarization and relaxation. Because these effects may have therapeutic relevance to hypersensitivity and asthma, we examined the effect of a potassium channel activator, cromakalim (BRL 34915, CK) on the release of mediators from superfused tracheal and parenchymal strips after passive sensitization with $IgG_1$ antibody. Both tissues were superfused with CK $(2{\times}10^{-6}\;M)$ for 30 min and challenged with CK and antigen (Ox-HSA). Using monodispersed, partially purified, highly purified guinea pig lung mast cells, we also examined the effect of CK on mediator release from these cells after passive sensitization with $IgG_{1}$ antibody $({\alpha}-OA)$. Guinea pig lung mast cells were purified using enzyme digestion method, count current elutriation, and discontinuous Percoll density gradient. After CK pretreatment, passively sensitized mast cells were challenged with varying concentration of antigen (OA, immunological stimuli) or with varying concentration of calcium ionophore (CaI, non-immunological stimuli). Histamine (Hist) release was determined by spectrophotofluorometry, and leukotrienes (LT) by radioimmunoassy. CK pretreatment decreased Hist by 35% and LT release by 40% in the antigen-induced tracheal tissue after $IgG_1$ sensitization but did not decrease the contractile response. In the antigen-induced parenchymal tissue CK decreased Hist release by 25% but poorly decreased LT. Both immunologic and non-immunologic stimuli caused a dose-dependent release of Hist and LT from monodispersed, partially purified and highly purified lung mast cells. Verification of LT release was obtained by the use of 5-lipoxygenase inhibitor, A64077 (Zileuton). CK decreased Hist and LT release by 20% respectively in the OA-induced guinea pig lung mast cells after $IgG_1$ sensitization. The inhibitory effects of CK on the Hist and LT release in the Ox-HSA-induced airway smooth muscle tissues or in the OA-induced and CaI-induced mast cells after $IgG_1$ sensitization were completely blocked by TEA and GBC. These studies show that guinea pig lung mast cells seem to be an important contributor to LT release, and that CK (which has been known as an airway smooth muscle relaxant) can in part act to inhibit mediator release in the antigen-induced airway smooth muscle, and that CK may also act to inhibit mediator release in the OA-induced and CaI-induced highly purified mast cells. These results suggest that Hist and LT release evoked by mast cell activation might in part be associated with $K{^+}4 channel activity.

  • PDF

A Role of Trial Radiation Therapy in the Pineal Region Tumors (송과체부 종양에서 시험적 방사선치료의 역할)

  • Kim, Yeon-Shil;Ryu, Mi-Ryung;Chung, Su-Mi;Kim, Moon-Chan;Yoon, Sei-Chul
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.100-107
    • /
    • 2002
  • Purpose : The aim of this retrospective study was to assess the treatment results of 30 patients with pineal region tumors who were underwent radiation therapy under the diagnosis by either CT or MRI. There was no histological verification. We analyzed the prognostic factors that have a significant effect on the overall survival (OS) and disease free survival (DFS) rates. Materials and Methods : A total 30 patients with pineal region tumors were treated between March 1983 and August 1995. After a trial radiation therapy of $20\~30\;Gy/2\~3$ weeks, the patients were evaluated for their clinical response and radiological response by either CT or MRI and the final treatment direction was then decided. According to their response to the trial radiation therapy and the involved site, radiation treatment was given in various fields i.e., local, ventricle, whole brain and craniospinal field. The radiation dose ranged from 40.8 to 59.4 Gy (Median 50.4 Gy). The median follow up was 36.5 months $(4\~172\;months)$. Results : An improvement or stability in the clinical symptoms was observed in 28 patients $(93.3\%)$ after the trial RT. Nineteen patients $(63.3\%)$ showed a partial or complete response by CT or MRI. The two-year and five-year survival rates of the patients were $66.7\%$ and $55.1\%$, respectively. No significant difference in the survival rates according to the degree of the radiological response was abserved after the trial RT. The results of univariate analysis showed that age, the primary site, the performance status $(KPS\geq70)$, the degree of response after completing RT and the RT field were significant prognostic factors affecting the survival and disease free survival rates (p<0.05). Conclusion : The clinical and histological characteristics of pineal region tumors are quite complex and diverse. Therefore, it is difficult to predict the histological diagnosis and the possibility of radiocurability only with the initial response to RT. We think that the development of less invasive histological diagnostic techniques and tailored treatment to the histological type of each tumor are needed.

Evaluation of Combine IGRT using ExacTrac and CBCT In SBRT (정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가)

  • Ahn, Min Woo;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Lee, Doo Sang;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.201-208
    • /
    • 2018
  • Purpose : The purpose of this study is to compare and analyze the set-up errors using the Combine IGRT with ExacTrac and CBCT phased in the treatment of Stereotatic Body Radiotherapy. Methods and materials : Patient who were treated Stereotatic Body Radiotherapy in the ulsan university hospital from May 2014 to november 2017 were classified as treatment area three brain, nine spine, three pelvis. First using ExacTrac Set-up error calibrated direction of Lateral(Lat), Longitudinal(Lng), Vertical(Vrt), Roll, Pitch, Yaw, after applied ExacTrac moving data in addition to use CBCT and set-up error calibrated direction of Lat, Lng, Vrt, Rotation(Rtn). Results : When using ExacTrac, the error in the brain region is Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, spine Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, pelvis Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$ When CBCT is performed after the couch movement, the error in brain region is Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, spine Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, pelvis Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$. Conclusion : Combine IGRT with ExacTrac in addition to CBCT during Stereotatic Body Radiotherapy showed that it was possible to reduce the set-up error of patients compared to single ExacTrac. However, the application of Combine IGRT increases patient set-up verification time and absorption dose in the body for image acquisition. Therefore, depending on the patient's situation that using Combine IGRT to reduce the patient's set-up error can increase the radiation treatment effectiveness.

  • PDF