• 제목/요약/키워드: Dose uniformity

검색결과 96건 처리시간 0.037초

Bi-material Bolus for Minimizing the Non-uniformity of Proton Dose Distribution

  • Takada, Yoshihisa;Kohno, Syunsuke
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.214-215
    • /
    • 2002
  • Generally uniform dose distribution is assumed to be formed in a target region when a conventional dose formation method using a broad proton beam, a fixed modulation technique, a bolus and an aperture is employed. However, actual situations differ. We usually find non-uniformity in the target region. This is due to the insertion of a range-compensating bolus before the patient. Since the range-compensating bolus has an irregular shape, the scattering in the bolus depends on the lateral position. Dose distribution is overlapping results of dose distribution of pencil-proton beams traversing different lateral positions of the bolus. The lateral extent of dose distribution of each pencil beam traversing the different position differs each other at the same depth in the target object. This is a cause of the non-uniformity of the dose distribution. Therefore the same lateral extent of dose distribution should be attained for different pencil beams at the same depth to obtain a uniform dose distribution. For that purpose, we propose here a bi-material bolus. The bi-material bolus consists of a low-Z material determining mainly the range loss and a high-Z material defining mainly the scattering in the bolus. After passing through the bi-material bolus, protons traversing different lateral positions will have different residual range yet with the same lateral spread at a certain depth. Using the optimized bi-material bolus, we can obtain a more uniform dose distribution in the target region as expected.

  • PDF

두부 CT의 노출 파라메타에 따른 화질과 선량의 변화 (Changes in Image Quality and Dose according to Exposure Parameters of Brain CT)

  • 최석윤;임인철
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.705-711
    • /
    • 2019
  • 현재 최신 장비의 두부 CT검사에서 파라메타의 변화와 선량변화에 대한 연구가 부족하고 특히 노이즈, 균일도 해석 및 선량변화에 대한 연구가 부족하다고 생각된다. 따라서 높은 사양 두부 CT 사용 시 노출 파라메타 중 관전압, 슬라이스 두께, 피치변화에 대해 분석하여 이때 발생하는 현상에 대해서 연구하고자 하였다. 실험을 통해서 균일도는 고관전압과 두꺼운 슬라이스 선택 및 최저 피치를 사용할 때 균일도가 좋음을 알 수 있었다. 모두 조합한 결과 균일도가 가장 조건은 140 kVp, 10 mm, pitch 0.5로 나타났다. 노이즈는 관전압과 슬라이스 두께를 높이면 피치에 관계없이 개선되는 것을 알 수 있었고, 선량은 관전압과 피치의 증가에 따라 선형적으로 증가하는 것으로 나타났다. 따라서 본 연구결과는 고 사양의 두부 CT 사용에서 참고자료가 될 것이다.

광자선을 이용한 전신 및 반신조사의 선량분포에 관한 고찰 (A study on the dose distribution for total-body & hemibody irradiation using clinical photon beams)

  • 김진기;권형철;김정수;오영기;김기환;신교철;김정홍;박충기;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제12권2호
    • /
    • pp.147-153
    • /
    • 2001
  • 방사선 전신 및 반신 조사방법을 방사선치료에 적용하여 균일한 선량 분포를 유도하고자 조사거리에서 선량측정, 조직결손에 따른 보상과 선량 보정 방법을 논의하였다. 의료용 선형가속기에서 발생된 6MV 광자선을 이용한 전신 조사시의 흡수선량을 결정하는, 선원과 조사면사이의 거리 변화에 따른 계산자료를 조사면의 중심축에서 고체 팬톰, RFA-7 물팬톰(Scanditronix, Sweden)에 대해 UNIDOS 전리함(PTW, Germany), THERADOS 전리함(Scanditronix, Sweden)을 이용한 측정으로 그 크기를 결정하였다. 조직보상체는 연판과 아크릴판을 이용하였다. 전신조사의 조건은 선원으로부터 380 cm의 거리에서 120 $\times$ 120 $cm^2$ ~ 152 $\times$ 152 $cm^2$ 의 조사면을 대상으로 하였다. 전신조사를 위한 기본 자료 측정에서 선원과 조사면의 거리 변화에 따른 흡수 선량 분포는 거리가 멀수록 더 증가하는 현상을 보였고, 조사면의 모서리부분은 약 10-20% 의 선량이 감소되었으나 굴곡좌위형 체위를 취함으로서 선량분포를 보완할 수 있었다. 연판과 아크릴판을 이용한 조직결손에 따른 보상체 제작으로 중심축 선량비를 $\pm$ 8% 이내로 감소시킬 수 있었다. 조직결손의 보상에 따른 선량계산을 고찰하여 임상 적용시 선량분포의 불균일성을 줄일 수 있었다.

  • PDF

방사선방어용앞치마(Apron)의 차폐율과 균일성 측정을 통한 성능평가 연구 (A study on performance evaluation of Apron by shielding rate and uniformity)

  • 유세종;임창선;심규란
    • 대한안전경영과학회지
    • /
    • 제17권1호
    • /
    • pp.103-109
    • /
    • 2015
  • In this study, we quantitatively analyzed the data by measuring the radiation shielding rate and uniformity in order to evaluate the performance of an Apron. In addition, storage conditions were also evaluated. The uniformity measurement was performed by evaluating the Apron DICOM images using a PACS program. The experiment was intended for 51 Aprons being used in three hospitals in the Daejeon area. The radiation shielding rate and uniformity were measured per lead equivalent for 0.25 mmPb, 0.35 mmPb, and 0.5 mmPb. As a result, the higher lead equivalents were, the greater differences in the non-uniformity between the top part and the bottom part became (p=0.020). In all hospitals, regarding the non-uniformity of four places in Aprons, all showed statistically significant differences (p<0.01). The average value of the transmitted radiation dose showed less difference (p=0.005) in the bottom right than in the upper right but was statistically significant. There have been no marks of manufacturing date or the date of purchase in the Apron.

Development of a Wide Dose-Rate Range Electron Beam Irradiation System for Pre-Clinical Studies and Multi-Purpose Applications Using a Research Linear Accelerator

  • Jang, Kyoung Won;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Jung Kee;Moon, Young Min;Kim, Jin Young;Jeong, Dong Hyeok
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.9-19
    • /
    • 2020
  • Purpose: This study aims to develop a multi-purpose electron beam irradiation device for preclinical research and material testing using the research electron linear accelerator installed at the Dongnam Institute of Radiological and Medical Sciences. Methods: The fabricated irradiation device comprises a dual scattering foil and collimator. The correct scattering foil thickness, in terms of the energy loss and beam profile uniformity, was determined using Monte Carlo calculations. The ion-chamber and radiochromic films were used to determine the reference dose-rate (Gy/s) and beam profiles as functions of the source to surface distance (SSD) and pulse frequency. Results: The dose-rates for the electron beams were evaluated for the range from 59.16 Gy/s to 5.22 cGy/s at SSDs of 40-120 cm, by controlling the pulse frequency. Furthermore, uniform dose distributions in the electron fields were achieved up to approximately 10 cm in diameter. An empirical formula for the systematic dose-rate calculation for the irradiation system was established using the measured data. Conclusions: A wide dose-rate range electron beam irradiation device was successfully developed in this study. The pre-clinical studies relating to FLASH radiotherapy to the conventional level were made available. Additionally, material studies were made available using a quantified irradiation system. Future studies are required to improve the energy, dose-rate, and field uniformity of the irradiation system.

고선량율 질강 근접조사를 위한 새로운 적용구의 제작 (Design of a New Applicator for High-Dose Rate Vaginal Brachytherapy)

  • 신세원
    • Journal of Yeungnam Medical Science
    • /
    • 제17권2호
    • /
    • pp.123-128
    • /
    • 2000
  • 본 연구에서 인체공학적으로 개선된 새로운 2-채널 고선량을 근접치료용 적용구(Shin's Applicator)를 개발하였으며, 기존의 단일 선원 근접치료 적용구와 비교하여 질벽에 더 균등한 방사선치료가 가능하고 방광과 직장선량이 적어 근접치료 후 발생할 수 있는 부작용이 감소될 가능성을 확인하였다. 임상적으로 Shin's Applicator는 자궁 경부암이나 자궁 체부암의 수술 후 국소재발이나, 절강에 발생한 다발설 악성종양을 효과적으로 치료하는 데 유용하게 사용될 수 있을 뿐 만 아니라, 방사선 치료 후 흔히 나타나는 질강의 협착을 예방할 수 있는 질 확장기(vaginal dilator)로도 사용 가능하였다. 이상의 결과에서 Shin's Applicator는 부인과 종양환자들의 방사선치료 뿐만 아니라 치료 후 삶의 질의 개선에도 크게 기여할 것으로 생각되었다.

  • PDF

MDCT 관상동맥 조영 검사에서 전향적 동조화 및 후향적 동조화 기법의 화질과 선량 관계 (An Estimate of Image Quality and Radiation Doses of Coronary Artery in MDCT Using Prospective and Retrospective ECG Gating Scan Mode)

  • 오종갑
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권4호
    • /
    • pp.315-321
    • /
    • 2011
  • 본 연구는 검사 기법에 따른 영상의 질과 방사선 피폭의 정도를 제시하여 검사자가 받는 방사선 피폭을 저감시키는 데 목적이 있다. 관상동맥 전산화 단층 혈관조영(Coronary CTA, coronary computed tomography angiography) 검사자를 대상으로 SnapShot Pulse의 전향적 동조화 기법과 SnapShot Segment의 후향적 동조화 기법으로 coronary CTA 검사에서 검사자가 받는 단면 피폭선량(CTDIvol, volume computed tomography dose index), 총 피폭선량(dose-length product; DLP)을 각각 측정하였다. 또한, Coronary CTA 촬영조건을 동일하게 팬텀을 이용하여 CT감약계수, 노이즈 및 균일도, 공간분해능을 측정하였다. 연구 결과 두기법에서 CT감약계수, 노이즈 및 균일도, 공간분해능의 질적 수준이 비슷하게 나타났으며, CTDIvol, DLP는 SnapShot Segment의 후향적 동조화 기법에 비해 피폭선량이 약 37.5%, 40.3% 감소되었다. 임상에서 coronary CTA 검사 시 SnapShot Pulse의 전향적 동조화 기법을 적극 채택하여 검사자가 받는 방사선 피폭을 감소시키기 위한 노력이 절실히 요구된다.

Leaf width가 다른 다엽 콜리메터에 의한 치료계획 비교 (Comparison of Treatment Plans with Multileaf Collimators of different Leaf Width)

  • 김주영;박성용;이두현;이석호;김태현;조관호
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.173-178
    • /
    • 2004
  • 목적: Leaf width가 다른 다엽 콜리메터(MLCs)를 이용, 두개내 병변에 관하여 각각의 세기조절방사선치료(IMRT) 계획을 수립하여, 이를 선량학적으로 비교하였다. 재료 및 방법: BrainSCAN ver. 5.2. 소프트웨어를 사용하여 micro-MLC로 이미 치료가 수행된 12명의 환자를 Varian사의 120 MLC와 80 MLC로 다시 치료계획하였으며 이 다엽 콜리메터들은 중심에서의 leaf width가 각각 3 mm, 5 mm, 10 mm이다. 이 때, 계획용 표적체적은 3.3~339.2 cc였고, 조사된 빔의 수는 3~7개이다. 이들을 uniformity Index, conformity index, 결정장기와 정상조직 내 선량으로 서로 비교하였다. 결과: 계획용 표적체적의 uniformity Index경우, mMLCs와 120 MLCs 사이에서 (p=0.057) 120 MLCs와 80 MLCs 사이에서(p=0.388) 통계적으로 차이가 없었다. 그러나 mMLCs와 80 MLCs 사이에서 차이를 보였다(p<0.001). 계획용 표적체적에 대한 최대 목표선량은 leaf width와 연관성이 없었다. 반면에, conformity Index의 경우는 mMLCs와 120 MLCs (p=0.003), mMLCs와 80 MLCs (p=0.003), 50 MLCs와 120 MLCs (p=0.003) 사이에서 통계적인 차이를 보였다. 처방선량의 70%와 50% 이상 조사되는 뇌간의 부피는 다엽 콜리메터의 leaf width가 증가함에 따라 증가하였다. 특히, leaf width의 변화에 따라 방사선에 조사되는 정상 뇌조직의 부피가 분명하게 변하였다. Leaf width가 3 mm인 다엽 콜리메터와 비교하였을 때, leaf width가 5 mm, 10 mm인 다엽 콜리메터의 부피 증가는 처방선량의 50% 이상 조사되는 정상조직의 경우, 각각 6.3%, 23.2%였고, 처방선량의 70% 이상 조사되는 정상조직의 경우, 각각 8.7%, 32.7%였다. 결론: 계획용 표적체적의 uniformity Index와 최대 목표선량은 leaf width와 연관성이 없었다. 그렇지만 conformity Index 는 leaf width가 감소함에 따라 향상되었다. 두개내 병변 치료시, 정상 뇌조직의 보존에 있어 leaf width 5 mm, 10 mm인 다엽 콜리메터를 이용한 치료계획보다 leaf width 3 mm인 다엽 콜리메터를 이용한 치료계획이 보다 효과적임을 알 수 있었다.

  • PDF

Standardization of uniformity of dosage unit for oral dosage forms

  • Kang, Shin-Jung;Yun, Mi-Ok;Choi, Hyun-Cheol;Kim, Ho-Jeong;Kim, Ji-Sun;Kim, Gil-Su
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.414.2-414.2
    • /
    • 2002
  • To secure the safety of drugs without compromising drug efficacy, it can not be more important to administer the exact intended amount of active ingredients to patients. Even if the correct amount of drugs are taken in the correct manner, drug can be overdosed or less-dosed without intention unless the content uniformity of the unit dose were secured. Especially, it can be a serious problem when it comes to drugs with narrow therapeutic windows or a strong pharmacological activity at a small dose. (omitted)

  • PDF

Leaf width가 다른 다엽 콜리메터에 의한 치료계획 비교 (Comparison of Treatment Plans with Multileaf Collimators of Different Leaf Widths)

  • 김주영;이두현;이석호;조관호;박성용
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.126-129
    • /
    • 2004
  • Leaf width가 다른 다엽 콜리메터 (MLCs)를 이용한 강도변조 방사선 치료 (IMRT)계획을 비교하였다. micro-MLCs를 사용하여 이미 시행된 12 case를 Varian사의 120 MLC와 80 MLC를 사용하여 다시 치료계획 하였다. 이들 콜리메터는 중심에서의 leaf width가 각각 3 mm, 5 mm, 10 mm이다. 이 치료계획들을 uniformity index, conformity Index, 정상조직 내선량으로 서로 비교하였다. PTV의 uniformity Index경우, mMLCs와 120 MLCs가 통계적으로 차이가 없었다 (p = 0.06). 그러나 mMLCs와80 MLCs는 통계적으로 약간의 차이를 보였다 (p = 0.001). PTV에 대한 최대목표선량은 leaf width와 연관성이 없었다. conformity index의 경우, mMLCs와 120 MLCs (p = 0.003)에서, mMLCs와 80 MLCs (p = 0.003)에서 통계적인 차이를 보였다. leaf width의 변화에 따라 방사선에 조사되는 정상조직의 부피를 비교하였고, leaf width가 3mm인 경우 정상조직 보존에 보다 적합함을 확인하였다.

  • PDF