• Title/Summary/Keyword: Dose reduction

Search Result 1,468, Processing Time 0.028 seconds

Analysis and Evaluation of Computed Tomography Dose Index (CTDI) of Pediatric Brain by Hospital Size (병원규모별 소아 두부 CT 검사 선량지표 분석 평가)

  • Kim, Hyeonjin;Lee, Hyoyeong;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.503-510
    • /
    • 2016
  • Even though children are exposed to the same amount of radiation, their effective dose amount is higher than those of adults. Therefore, it is very important to reduce the amount of unnecessary radiation exposure because children have a higher radiosensitivity and a smaller body size than adults. In this study, the proposal to seek ways to reduce the amount of radiation is drawn by comparing and analyzing CT Dose Index(CTDI) on the pediatric head CT which was performed at the Busan regional hospitals, to the national diagnostic reference levels. For this, the pediatric head CT scan was conducted among the CT equipments that were installed in downtown Busan. From 2,043 children 10 years old or less who were referred to the pediatric head CT scan, targeting the 28 CT equipments in the 24 hospitals that transmit dose reports to PACS, were examined retrospectively. As a result, the average value of CTDIvol, computed tomography dose index (CTDI) of infant brain, across the hospital, was 31.18 mGy, with DLP of $444.73mGy{\cdot}cm$, which exceeded the diagnostic reference level. The lower the age, the more management is needed for radiation. However, the reality is that the CT examinations are being conducted with a dose that exceeds the reference level as the age of the aged is exceeded. For this purpose, the study seeks to determine the degree of doses of doses outside the diagnostic reference level and analyze the cause of the excess dose and devise measures to reduce the dose reduction.

A Study on Dose Distribution around Fletcher-Suit Colpostat Containing Cs-137 Source by a Computer (컴퓨터 의한 Fletcher-Suit Colpostat 주변의 Cs-137의 선량분포에 관한 연구)

  • Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.305-311
    • /
    • 1989
  • Fletcher-Suit colpostat has an internal structure to reduce dose to bladder and rectum. Some programs were developed to calculate dose at any point in water in three dimension around the colpostat containing Cs-137 tube, to find the shielding effect to dose by the internal structure, and to draw isodose curves and iso-shielding effect curves. Computer was an IBM compatible AT with EGA card and language was MS-Basic V6.0, Material, shape and geometry of the strucure, tube and colpostat were considered in algorithm for calculation of dose. Dose rates per unit mg. Ra. eq. in water calculated by a program were stored in auxiliary memory devices and retrieved in another programs. Isodose curves on medial side shrinked. Dose distribution was not symmetric about a transverse axis bisecting the colpostat. Reduction of dose was more excessive on top side than on bottom. Iso-shielding effect curve showed that the shielding effect was higher on top side than on bottom, and that there was shielding effect over almost all area of medial side. Such results were related to both shifted position of tube in the colpostat and asymmetric distribution of active source in the tube. Maximum of shielding effect was $49\%$ on top side and $44\%$ on bottom side. The direction of iso-shielding effect curve was generally radial from the center of active source. In treatment planning using Fletcher-Suit colpostat, the internal structure should be considered to find precise doses to bladder and rectum, etc.

  • PDF

The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography (Digital Chest Radiography에서 방사선량에 대한 Source to Image-Receptor Distance (SID)의 영향)

  • Kwon, Soonmu;Park, Changhee;Park, Jeongkyu;Son, Woonheung;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.203-210
    • /
    • 2014
  • Chest radiography has been typically performed at SID of 180 cm. Image quality and patient dose were investigated between 180 cm and 340 cm by 20 cm intervals at 120 kVp and 320 mAs with the AEC. VGA was performed for qualitative assessment and SNR was analysed for quantitative assessment on the image of the chest phantom. Patients dose was measured by ESAK and PCXMC was used for effective dose. As a result, when using the standard of SID of 180 cm which is typically used in the clinical practice, in the case of ESAK, 240 cm, 280 cm, and 320 cm were 8.7%, 11.47%, and 13.56% respectively therefore significant reduction was confirmed. In the case of effective dose, 2.89%, 4.67%, and 6.41% in the body and 5.08%, 6.09%, and 9.6% in lung were reduced. In the case of SNR, 9.04%, 8.24%, and 11.46% were respectively decreased especially, by 8.03% between SID of 260 cm and 300 cm, but SNR was 5.24 up to 340 cm. There were no significant differences in VGA thus the image is valuable in diagnosis. It is predicted that increasing SID up to 300 cm in digital chest radiography can reduce patient dose without decreasing image quality.

Effects of chloramphenicol on chemiluminescence response of leukocytes isolated from olive flounder, Paralichthys olivaceus (양식산 넙치, Paralichthys olivaceus 식세포의 식작용 활성에 미치는 chloramphenicol의 영향)

  • Seo, Jeong-Su;Jeong, So-Jeong;Lee, Sang-Hwan;Kim, Na-Yeong;Eom, Hye-Gyeong;Heo, Min-Do;Jeong, Hyeon-Do;Jeong, Jun-Gi
    • Journal of fish pathology
    • /
    • v.17 no.3
    • /
    • pp.217-222
    • /
    • 2004
  • This study was performed to investigate the immunological side effects of chloramphenicol (CAP) on olive flounder, Paralichthys olivaceus. To investigate immunological effects on olive flounder, we determined the changes of chemiluminescence (CL) response of flounder kidney-derived leucocyte after the treatment of CAP in vivo and in vitro. The CL activity was significantly decreased in a dose-dependent manner during the treatment of CAP in vitro. Similarly, a dose-dependent reduction of CL response, although not significant, were observed during the treatment of CAP in vivo. The results suggest that CAP reduced the function of flounder phagocytosis in vivo and in vitro, indicating the immunosuppressive ability of CAP.

Fetal growth retardation induced by maternal exposure to phenol in the rat (임신 랫트의 페놀 노출에 따른 태자의 발육 지연효과)

  • Chung, Moon-koo
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.3
    • /
    • pp.601-607
    • /
    • 1994
  • This study was carried out to investigate the potential of phenol to induce embryotoxicity in the Sprague-Dawley rat. Seventy mated rats were distributed among three treated troups, a vehicle control group and a negative control group. Phenol was at dose levels of 20, 60 and 180mg/kg/day adminsistered by gavage to pregnant rats three times per day from days 7 to 12 of gestation. All dams were subjected to the caesarean section on day 20 of gestation. At 120mg/kg, dams exhibited decreased locomotivity. In addition, both weight reduction and retarded ossification of fetuses were observed. There were no signs of maternal toxicity or embryotoxicity at 20 and 60mg/kg. The results show that phenol induces fetal growth retardation at maternally subtoxic dose in rats.

  • PDF

Cytotec Induced Embryotoxicity in Developing Mus musculus

  • Naeem, Khadija;Ahmad, Naveed;Asmatullah, Asmatullah
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.10
    • /
    • pp.1282-1290
    • /
    • 2010
  • The study was carried out to assess the developmental abnormalities induced by Cytotec in mice during intrauterine life. Pregnant mice were exposed to a single dose of 0, 0.02, 0.04, 0.06, 0.08 and $0.1{\mu}g$/g BW on day 8 of gestation. Fetuses were recovered on day 18 of gestation. These fetuses were subjected to morphological and morphometric studies. Morphological studies showed abnormalities like anophthalmia, microophthalmia, micromelia and syndactyly. In addition to these, resorptions were also encountered in the higher dose groups. Morphometric analysis showed an overall reduction in body weight, crown rump length, brain and eye circumference, pinna and snout size, length of fore and hind limb and tail size with a significant difference (p<0.001) compared to controls. The outcomes of histological studies revealed some brain defects like hydrocephaly, enlarged third ventricle and undifferentiated ectoneural cells and abnormalities of the heart included right auricle thrombosis and degeneration of trabecular zone.

Biological Activities of the Root of Cichorium intybus

  • Ki, Chang-Geun;Yim, Dong-Sool;Lee, Sook-Youn
    • Natural Product Sciences
    • /
    • v.5 no.4
    • /
    • pp.155-158
    • /
    • 1999
  • Several biological activities of extracts from roots of Cichorium intybus Linne (Compositae) were studied in this paper. The antiinflammatory activity of the methanol extract of this root was investigated against carrageenin induced edema in rat‘s hind paw. Significant inhibitory effects were observed at the dose of 1,000 mg/kg and were compared with aspirin as a control. The hepatoprotective activities of the methanol extract, ethylacetate and butanol fraction were studied on mice whose livers are damaged by $CCl_4$. The serum transaminase activities (ALT, AST) were reduced at the dose of 1,000 mg/kg of the methanol extract, 500 mg/kg of ethylacetate and butanol fraction, respectively. The bile juice secretion was also increased significantly from each fraction. The antidiabetic activity was examined on strepto-zotocin-induced diabetic rats with methanol extract. Methanol extract gave a significant reduction of blood glucose levels in 1 week and 3 weeks.

  • PDF

Effects of Gamma-Irradiation on the Water Absorption Property of Black Soybeans (감마선 조사가 검정콩의 수분흡수 특성에 미치는 영향)

  • 김종군
    • Journal of the Korean Home Economics Association
    • /
    • v.30 no.3
    • /
    • pp.101-117
    • /
    • 1992
  • Effects of gamma irradiation(2.5∼20kGy) on water absorption property was studied for a local variety of black soybeans. In water absorption patterns of black soybeans, the time to reach a fixed moisture content was reduced depending on the increment of water soaking temperature and irradiation dose. Irradiation at 2.5∼10kGy resulted in the reduction of soaking time of black soybeans by about 1∼3 hours and the increase of hydration capacity by 10∼20%, respectively, compared to the nonirradiated control black soybean. The water uptake rate constant of the irradiated black soybean difinitely increased with the increase of dose levels and water soaking temperature. The activation energy for water absorption and z-value were lower in the irradiated black soybeans than in the nonirradiated control black soybean. The efficacy of water absorption property in the irradiated black soybeans was also recognized after one year of storage at room temperature.

  • PDF

Physical Dependence on DA-5018, a Non-narcotic Analgesic Agent (비 마약성 진통제 DA-5018의 신체의존성)

  • 강경구;김동환;백남기;김원배;양중익
    • Biomolecules & Therapeutics
    • /
    • v.4 no.3
    • /
    • pp.232-238
    • /
    • 1996
  • The physical dependence potency of DA-5018, a non-narcotic analgesic agent, was tested in mice dosed with 0.5 and 4 mg/kg/day for 2 months and daily increasing doses of 1, 2, 4, 6, 8 and 10 mg/kg over 10 days. Physical dependence was assessed taking natural withdrawal induced morphine-type abstinence (jumping, falling, biting or backward locomotion, rearing etc.) as well as barbiturates-type abstinence (body weight reduction, convulsion, ataxia etc.) into consideration. The results were compared with those after the same daily increasing doses of morphine. DA-5018 did not show evidence of physical dependence liability or abuse potential as measured by morphine-type or barbiturate-type abstinence signs following daily increasing or 2-month repeated administration. On the other hand, daily increasing doses of morphine produced physical dependence and the dependent state disappeared about 6 hours after the start of withdrawal signs. In the single dose suppression test, a single dose of morphine completely suppressed natural withdrawal signs that appeared in morphine-dependent animals. Therefore, these results indicate that DA-5018 does not have abuse potential and physical dependence liability.

  • PDF

The Effect on Patient Dose Reduction with Improvement of the Output Characteristics for Inverter Type X-ray Generator (인버터식 X선발생장치의 출력특성개선이 환자피폭선량 경감에 미치는 효과)

  • Roh, Mo-Eun;Lee, Seong-Kil;Kim, Young-Keun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.27-32
    • /
    • 2011
  • The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple. In this paper, the newly developed x-ray generator in a low cost using duty modulation PWM inverter. This system verify improved performance by stabilize ripple of X-ray tube voltage and compared the reproducibility, linearity and dose in single phase, three phase and PSU.

  • PDF