• 제목/요약/키워드: Dose rate effect

검색결과 1,015건 처리시간 0.029초

Insights from an OKMC simulation of dose rate effects on the irradiated microstructure of RPV model alloys

  • Jianyang Li;Chonghong Zhang;Ignacio Martin-Bragado;Yitao Yang;Tieshan Wang
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.958-967
    • /
    • 2023
  • This work studies the defect features in a dilute FeMnNi alloy by an Object Kinetic Monte Carlo (OKMC) model based on the "grey-alloy" method. The dose rate effect is studied at 573 K in a wide range of dose rates from 10-8 to 10-4 displacement per atom (dpa)/s and demonstrates that the density of defect clusters rises while the average size of defect clusters decreases with increasing dose rate. However, the dose-rate effect decreases with increasing irradiation dose. The model considered two realistic mechanisms for producing <100>-type self-interstitial atom (SIA) loops and gave reasonable production ratios compared with experimental results. Our simulation shows that the proportion of <100>-type SIA loops could change obviously with the dose rate, influencing hardening prediction for various dose rates irradiation. We also investigated ways to compensate for the dose rate effect. The simulation results verified that about a 100 K temperature shift at a high dose rate of 1×10-4 dpa/s could produce similar irradiation microstructures to a lower dose rate of 1×10-7 dpa/s irradiation, including matrix defects and deduced solute migration events. The work brings new insight into the OKMC modeling and the dose rate effect of the Fe-based alloys.

Indirect assessment of internal irradiation from tritium decay on Lemna Minor duckweed

  • Ifayefunmi, O.S.;Mirseabasov, O.A.;Synzynys, B.I.
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1991-1999
    • /
    • 2021
  • The response changes of the specific growth rate of Lemna minor duckweed was modeled using the logarithms of frond numbers on tritium activity concentration and gamma radiation dose from cobalt 60. The concept of average specific growth rate depends on the general exponential growth pattern, where toxicity is estimated based on the effect on the growth rate. One of the main questions of the effect of the radiation dose on duckweed is how to correlate the effect of beta radiation with the effect of any other radiation for modeling radiation on Lemna minor. Experimental data were extrapolated by utilizing the OECD guidelines. A linear relationship of absorbed dose and activity concentration was obtained for the average dependency growth rate of Lemna minor as D = (0.1257)·A0.585. The dose rate of gamma irradiation from 60Co increases with tritium activity dependence, on the specific growth rate of the Lemna minor duckweed. An increase in the tritium activity causes a decrease in the specific growth rate of the Lemna minor duckweed. It indicates that as the quantity of the beta radiation dose increase in Lemna minor duckweed, a higher quantity of gamma radiation will be required to cause the same effect in the specific growth rate of Lemna minor duckweed. The relation between the inhibition of the Lemna minor seedling growth and gamma and beta radiation dosage agrees roughly with that between the decrease of survival rate or fertility and dosage.

영광 원자력 발전소 주변 환경 방사능 측정에 관한 연구 (The study on Measuring of Environmental Radioactivity in the Vicinity of Yonggwang Nuclear Power Plant)

  • 박종섭
    • 자원환경지질
    • /
    • 제32권3호
    • /
    • pp.273-280
    • /
    • 1999
  • In order to protect inhabitans' health and to collect data for prediction of the effcts from accidental emission of rasioactive materials from nuclear power plant, exposed dose rate be monitored within the limit dose rate. This research was carried out to investigate the accumulation of environmental radioactivity around Younggwang Nuclear Power Plant, and to infer and in infer and assay the additional exposed dose rate of inhabitants in Younggwang site from the operation of nuclear plant operation. External radiation dose rate, radiation environmental samples, and exposed dose rate of inhabitants in Younggwang site were investigated for estimaing environment activity in the vicinity of the nuclear power plant area. For the external radiation dose rate, the result showed that range of normal variation was found and any artificial radioisotope was not deteted in the analysis of environmental samples. Exposed dose rate of inhabitants was lower than 0.4% of the limit value of ICRP and it may be concluded that there was no effect on inhabitants and environment from the operation of nuclear power plant.

  • PDF

Silicon P-N Junction Diode에 대한 X-Ray 및 Gamma-Ray 의 Dose Ratec 측정 (Measurements of X-Ray and Gamma Ray Dosse Rate by the Silicon P-N Junction Diode)

  • 정만영;김덕진
    • 전기의세계
    • /
    • 제13권3호
    • /
    • pp.13-20
    • /
    • 1964
  • The measurements of X-ray and Gamma-ray Dose Rate have been successfully made by measuring the short circuit current of the Silicon P-N Junction Diode being irradiated. The short circuit current flows when a silicon P-N Junction Diode is irradiated by X-ray of Gammaray radiations due to photovoltaic effect. A brief analysis is given in order to verify the proportionality of a short circuit current to the Dose Rate. Using this method, measurements of X-ray Dose Rate were carried out in the range of 0.05-1600 r/m successfully. The calibration was made by comparing with Victoreen condenser r-meter. Some advantages in this Dose Rate meter over a condenser r-meter were found. One can measure a continous variation of X-ray Dose Rate with this rate meter at the control console of X-ray device.

  • PDF

고 선량 감마선 조사에 따른 고휘도 LED의 가시광 무선 데이터 전송 (VLC Wireless Data Transmission of High Luminance LED Irradiated by the High Dose-Rate Gamma-Ray)

  • 조재완;최영수;홍석붕
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.996-1000
    • /
    • 2010
  • In order to apply VLC (visible light communication) in harsh environment of nuclear power plant in-containment building, the high luminance LEDs, which are key components of the VLC system, have been gamma irradiated at the dose rate of 4 kGy/h during 72 hours up to a total dose of 288 kGy. The radiation induced coloration effect in the high luminance LED bulb made of acryl or plastic material was observed. In the VLC wireless data transmission experiment using the high luminance LEDs irradiated by high dose rate gamma-ray, the radiation induced coloration effect of the high luminance LED bulb extended the communication distance compared to non-irradiated LEDs.

Effects of Sperm Number and Semen Type on Sow Reproductive Performance in Subtropical Area

  • Kuo, Y.H.;Hnang, S.Y.;Lee, K.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권1호
    • /
    • pp.6-9
    • /
    • 2000
  • The purpose of this study was to evaluate the effect of lower numbers of sperm $(3{\times}10^9)$ per dose liquid semen and type of semen used in artificial insemination (AI) on sow reproductive performance in subtropical area. Semen was supplied by two commercial AI centers. A total of 671 female pigs from seven farms were inseminated with either $3{\times}10^9$ or $5{\times}10^9$ sperm per dose. Two types of semen were used: heterospermic semen from two boars of the same breed and homospermic semen from a single boar. After insemination, conception rate, farrowing rate, total litter size, and number of dead piglets were recorded. The analysis of variance indicated that there was no significant effect of interactions between pig farm, type of semen, or number of sperm on any of the traits measured. There were significant differences in conception rate, farrowing rate, and total litter size among pig farms (p<0.05). The effect of number of sperm per dose liquid semen ($3{\times}10^9$ or $5{\times}10^9$) was not significant. Sows inseminated with homospermic semen showed significantly higher conception and farrowing rates but significantly lower total litter size (p<0.05). In conclusion, the number of sperm per dose liquid semen for AI could be lowered to $3{\times}10^9 $ without affecting reproductive performance in subtropical areas like Taiwan.

광섬유 브래그 격자 센서를 이용한 국내외 상용 단일모드 광섬유의 감마선 영향 연구 (A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber using Fiber Bragg Grating Sensor Systems)

  • 김종열;이남호
    • 한국정보통신학회논문지
    • /
    • 제16권10호
    • /
    • pp.2287-2292
    • /
    • 2012
  • 본 논문에서는 Ge가 함유된 일반 단일모드 광섬유의 감마선 유입손실을 측정하였다. 방사선 선원은 $Co^{60}$ 감마선 선원을 이용하였으며, 총 4시간동안 0.5 kGy/hr, 2 kGy/hr, 8 kGy/hr의 선량률로 조사하였다. 그 결과 감마선 조사에 의한 단일모드 광섬유의 전송손실이 뚜렷하게 나타났으며, 동일 누적선량에서 선량률이 클수록 전송손실이 증가하는 선량률 효과가 나타났다. 또한 감마선 조사 종료 후 광섬유의 전송손실이 클수록 유입손실의 회복률이 증가하는 어닐링 특성을 보였다. 본 실험결과는 향후 광섬유의 내방사화 연구의 기초자료로 활용할 것이다.

재생과 증식에 기인하는 선량률 효과 (Dose-Rate Effects Generated from Repair and Regeneration)

  • 이본녕;조관호;막스 리차드;김재호
    • Radiation Oncology Journal
    • /
    • 제7권2호
    • /
    • pp.171-183
    • /
    • 1989
  • Roesch의 생존 방정식속에 세포증식으로 일어나는 생존증가를 가장 일반적 형식으로 포함시킨 식을 유도하고 이 식으로부터 저선량률 방사선에만 적용되는 동결과선량식 (Isoeffect formula)을 유도하였다. 이 저선량률식이 파라메터 하나로 결정해주는 총선량은 Paterson과 Green에 의하여 얻어진 실험 임상결과와 일치한다. 이 파라메터와 선량률 효과 사이의 관계의 의의를 논하였다. 또한 고선량률 분절(fractionation) 치료와 동저선량률 계속치료를 연락하는 동결과 선량식을 유도 사용하여, Ellis가 잰 실험결과와 비교하였다. 그 결과, Ellis와 Paterson이 쓴 'tolerance'의 표준이 $\alpha/\beta$의 비 4Gy에 해당하는 것임이 밝혀졌다. 그러므로 이들의 'tolerance'의 표준은 'early effect'에만 두고 본 것이 아님을 알 수 있다. 개념적인 면에서도, 아래와 같은 새로운 견해가 나올 수 있다. KHT sarcoma의 생존선도 (survival curve)에 선량률 효과가 보이지 않는 이유로 $\alpha/\beta$의 비가 큰 점을 들을 수 있다. 이것은 이 survival curve에 어께 (shoulder)가 보이지 않는 것으로도 증명이 된다. Pierquin이 선량률에 무관하게 head and neck tumor치료에 같은 총선량을 쓴 것을 정당화시킬 수 있다.

  • PDF

Low LET X-ray가 췌장 ${\beta}$ 세포와 신경세포에 미치는 효과 (Effect on Pancreatic Beta Cells and Nerve Cells by Low LET X-ray)

  • 박광훈;김구환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권1호
    • /
    • pp.21-28
    • /
    • 2014
  • 배양된 췌장베타세포와 신경세포를 10% FBS (fetal bovine serum), 11.1 mM glucose의 normal 조건과 1% FBS, 30 mM glucose의 hyperglycemia 조건으로 배양하고, 저 LET X-선을 0.5 Gy/hr의 선량률로 총 선량이 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5 Gy가 되도록 저 LET 방사선을 조사한 후 MTT assay로 생존율을 측정하고 비교하였다. 분화된 췌장베타세포에 방사선을 조사하지 않았을 때는 normal 조건에 비해 hyperglycemia 조건의 생존율이 경미한 감소를 보였다. 그러나 X선의 총 선량이 점차 누적됨에 따라 normal 조건에서 생존율이 조금씩 감소하는 것에 비해 hyperglycemia 조건에서는 급격히 감소하여 시너지 효과를 나타냈다. 미분화된 신경세포에서는 방사선을 조사하지 않은 때도 normal 조건에 비해 hyperglycemia 조건의 생존율이 뚜렷하게 감소하였다. X선의 총 선량이 점차 누적됨에 따라 normal 과 hyperglycemia 조건 모두에서 비교적 급격한 세포사멸이 나타났지만 그 생존율의 감소비율이 거의 평행하게 진행되어 시너지 효과를 보이지 않았다.

A Review of Dose Rate Meters as First Responders to Ionising Radiation

  • Akber, Aqeel Ahmad;Wiggins, Matthew Benfield
    • Journal of Radiation Protection and Research
    • /
    • 제44권3호
    • /
    • pp.97-102
    • /
    • 2019
  • Background: Dose rate meters are the most widely used, and perhaps one of the most important tools for the measurement of ionising radiation. They are often the first, or only, device available to a user for an instant check of radiation dose at a certain location. Throughout the world, radiation safety practices rely strongly on the output of these dose rate meters. But how well do we know the quality of their output? Materials and Methods: This review is based on the measurements 1,158 commercially available dose rate meters of 116 different makes and models. Expected versus the displayed dose patterns and consistency was checked at various dose rates between $5{\mu}Gy{\cdot}h^{-1}$ and $2mGy{\cdot}h^{-1}$. Samples of these meters were then selected for further investigation and were exposed to radiation sources covering photon energies from 50 keV to 1.5 MeV. The effect of detector orientation on its reading was also investigated. Rather than focusing on the angular response distribution that is often reported by the manufacturer of the device, this study focussed on the design ergonomics i.e. the angles that the operator will realistically use to measure a dose rate. Results and Discussion: This review shows the scope and boundaries of the ionising radiation dose rate estimations that are made using commonly available meters. Observations showed both inter and intra make and model variations, occasional cases of instrument failure, instrument walk away, and erroneous response. Conclusion: The results indicate the significance of selecting and maintaining suitable monitors for specific applications in radiation safety.