• Title/Summary/Keyword: Dose coefficients

Search Result 151, Processing Time 0.027 seconds

Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method

  • Pamela Sung;Jeong Min Lee;Ijin Joo;Sanghyup Lee;Tae-Hyung Kim;Balaji Ganeshan
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.558-568
    • /
    • 2019
  • Objective: To evaluate whether computed tomography (CT) reconstruction algorithms affect the CT texture features of the liver parenchyma. Materials and Methods: This retrospective study comprised 58 patients (normal liver, n = 34; chronic liver disease [CLD], n = 24) who underwent liver CT scans using a single CT scanner. All CT images were reconstructed using filtered back projection (FBP), hybrid iterative reconstruction (IR) (iDOSE4), and model-based IR (IMR). On arterial phase (AP) and portal venous phase (PVP) CT imaging, quantitative texture analysis of the liver parenchyma using a single-slice region of interest was performed at the level of the hepatic hilum using a filtration-histogram statistic-based method with different filter values. Texture features were compared among the three reconstruction methods and between normal livers and those from CLD patients. Additionally, we evaluated the inter- and intra-observer reliability of the CT texture analysis by calculating intraclass correlation coefficients (ICCs). Results: IR techniques affect various CT texture features of the liver parenchyma. In particular, model-based IR frequently showed significant differences compared to FBP or hybrid IR on both AP and PVP CT imaging. Significant variation in entropy was observed between the three reconstruction algorithms on PVP imaging (p < 0.05). Comparison between normal livers and those from CLD patients revealed that AP images depend more strongly on the reconstruction method used than PVP images. For both inter- and intra-observer reliability, ICCs were acceptable (> 0.75) for CT imaging without filtration. Conclusion: CT texture features of the liver parenchyma evaluated using the filtration-histogram method were significantly affected by the CT reconstruction algorithm used.

Development of a Sandwich Enzyme Immunoassay for Salmon Gonadotropin II. (연어 생식소자극호르몬 II의 Sandwich Enzyme Immunoassay법 개발)

  • KIM Dae-Jung;HAN Chang-Hee;AIDA Katsumi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.1
    • /
    • pp.55-59
    • /
    • 2000
  • A specific and sensitive sandwich enzyme-immunoassay (EIA) using Avidin-Biotin complex was developed for the measurement of GTH II levels in pituitary content and pituitary cell culture medium of the rainbow trout-(Oncorhpchus mykiss). Biotin-salmon GTH II rabbit IgG (sefondary antibody) wai purified by a protein A sepharose affinity chromatography column and that was biotinylated by using Biotin-N-hydroxysuccinimide ofter (BNHS). Non-biotin salmon GTH II rabbit IgG (first antibody) was obtained only through a protein A sepharose affinity chromatography column. The assay was performed by the so-called 'sandwich' method using a microtiter plate, A dose-response curve was obtained between $0.12 to 125 ng/ml$ of salmon GTH II. The displacement curves for pituitary extraction and pituitary cell culture medium of testosterone-treated rainbow trout were Parallel to the standard curie. The intra-assay and inter-assay coefficients of variation (CV) were $8.2{\%} (N=5) and 12.5{\%} (N=6)$, respectively, This assay system was used to measure the amount of GTH II that accumulated in the culture medium of dispersed pituitary cells in testosterone-treated immature rainbow trout, The accumulation was increased with the amount or salmon gonadotropin-releasing hormone. GTH II values determined by the present method were well correlated with those determined by radioimmunoassay. As a result, this assay system was found to be suitable for the measurement of GTH II for pituitary extraction and pituitary culture medium in many salmonid fishes.

  • PDF

Xylanase Supplementation Improved Digestibility and Performance of Growing Pigs Fed Chinese Double-low Rapeseed Meal Inclusion Diets: In vitro and In vivo Studies

  • Fang, Z.F.;Peng, J.;Tang, T.J.;Liu, Z.L.;Dai, J.J.;Jin, L.Z.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.11
    • /
    • pp.1721-1728
    • /
    • 2007
  • An in vitro and a feeding trial were conducted to investigate the effect of xylanase supplementation on the feeding value of growing pig diets containing high proportions of Chinese double-low rapeseed meals (DLRM). Seven diets were formulated to meet NRC (1998) nutrient requirements. Diet 1 based on corn-soybean meal was used as positive control 1, and diet 2, a practical diet which incorporated a conventional level of Chinese DLRM (60 g/kg diet), as positive control 2. Diet 3 contained a higher level of DLRM (100 g/kg diet) as the negative control. Diet 3 plus xylanase at 0.10, 0.25, 0.50 and 0.70 g/kg diet created diets 4, 5, 6 and 7, respectively. The seven diets were incubated in triplicate with the in vitro two-stage enzyme incubation method to predict responses of diets to xylanase in terms of digestibility of dry matter (DM), crude protein (CP) and neutral detergent fibre (NDF). In vitro, the negative control had the lowest CP and NDF digestibility. Both DM and CP digestibility were increased (p<0.05) owing to xylanase supplementation either at 0.50 or 0.70 g/kg diet, and NDF digestibility was improved following xylanase addition at all of the test levels. There was a high linear correlation ($r^2>90$, p<0.05) between the activity concentration of the enzyme when transformed into its logarithmic value and in vitro digestibility coefficients of DM, CP or NDF. In the feeding trial, 112 crossbred pigs were randomly assigned to seven dietary treatments with 16 replicate pens of one pig each. An obvious dose effect on growth rate was observed ($r^2=0.79$, p<0.05) within the inclusion levels of xylanase. Compared with the negative control, xylanase addition at 0.70 g/kg diet resulted in significantly increased ADG (878 g/d vs. 828 g/d, p<0.05), and a tendency towards improved growth rate (868 g/d vs. 828 g/d, p = 0.10) was also observed following the inclusion of xylanase at 0.50 g/kg diet. It would appear that the nutrient utilization of corn and Chinese DLRM diets by pigs could be enhanced by an appropriate amount of xylanase addition. The in vitro and in vivo results suggested that the in vitro incubation method is feasible for predicting responses of pigs to exogenous enzymes and identifying those preparations that possess potential for improvement of the nutritive values of feedstuffs.

Rapid and Simple Method for the Determination of Pregabalin in Human Plasma using Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS): Application to a Bioequivalence Study of Daewoong Pregabalin Capsule To Lyrica® Capsule (Pregabalin 150 mg)

  • Jang, Ki-Ho;Seo, Ji-Hyung;Yim, Sung-Vin;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.4
    • /
    • pp.255-262
    • /
    • 2011
  • Method using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the determination of pregabalin in plasma samples. Acquisition was performed by monitoring the transitions: m/z 160.1${\rightarrow}$142.2 for pregabalin and m/z 423.2${\rightarrow}$207.1 for losartan (as an internal standard). After cold acetonitrileinduced protein precipitation of the plasma samples, separation was performed with C18 column by isocratic mobile phase consisted of 10 mM ammonium acetate and acetonitrile (15:85, v/v). Results were linear over the concentration ranged from 0.1 to $10{\mu}g$/mL and the correlation coefficients (r) were $\geq0.99$. Intra- and inter-day precisions were $\leq6.02$ and $\leq11.04%$, respectively, and intra- and inter-day accuracies were 96.60-101.09 and 98.10-102.60%, respectively. This validated method was successfully applied to a bioequivalence study of two formulations of pregabalin, Daewoong pregabalin capsule (Daewoong Pharm. Co., Ltd.) and Lyrica$^{(R)}$ capsule (Pfizer Korea Ltd.) in twenty eight healthy Korean volunteers. The subjects received a single oral dose of each formulation (150 mg as pregabalin) in a randomized $2{\times}2$ crossover study and plasma samples were obtained from each subject at predetermined time intervals. Then, the pharmacokinetic parameters ($AUC_{0-t}$, $C_{max}$ and $T_{max}$) were calculated and statistically analyzed to assess the differences between two formulations. The 90% confidence intervals for the log-transformed data were acceptable range of log 0.8-log 1.25 (e.g., log 1.0048-log 1.0692 for AUC0-t, log 0.9142-log 1.0421 for $C_{max}$). Thus, $AUC_{0-t}$ and $C_{max}$ met the criteria of the Korea Food and Drug Administration (KFDA) for bioequivalence test indicating that Daewoong pregabalin capsule was bioequivalent to Lyrica$^{(R)}$ capsule.

Bioequivalence Study of Toriem® Tablet to Motilium-M® Tablet (Domperidone Maleate 12.72 mg) Evaluated by Liquid Chromatography/Tandem Mass Spectrometry

  • Ryu, Ju-Hee;Choi, Sang-Jun;Lee, Myung-Jae;Lee, Jin-Sung;Kang, Jong-Min;Tak, Sung-Kwon;Seo, Ji-Hyung;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.65-71
    • /
    • 2009
  • The aim of the present study was to evaluate the bioequivalence of two domperidone maleate tablets, Motilium-$M^{(R)}$ Tablet (Janssen Korea Ltd., reference product) and $Toriem^{(R)}$ Tablet (Daewon Pharm. Co., Ltd., test product). Domperidone was extracted by liquid-liquid extraction using tert-butyl methyl ether and separated in less than 3 min on $C_{18}$ reverse-phase column using an isocratic elution. A tandem mass spectrometer, as detector, was used for quantitative analysis in positive mode by a multiple reaction monitoring mode to monitor the m/z $426.1{\rightarrow}119.1$ and the m/z $837.4{\rightarrow}158.2$ transitions for domperidone and the internal standard (roxithromycin), respectively. Calibration curves, from $0.05{\sim}50$ ng/mL of domperidone, showed correlation coefficients (r) higher than 0.9941. Intra day and inter day precision (C.V. %) for quality control were ranged from 10.04 to 16.09% and from 10.87 to 18.69%, respectively. The lower limit of quantification (LLOQ) of domperidone was 0.05 ng/mL. The method described is precise and sensitive and has been successfully applied to the study of bioequivalence of domperidone in 24 healthy Korean volunteers. Twenty-four healthy male Korean volunteers received a single dose of each medicine ($2{\times}12.72\;mg$ domperidone maleate) in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of domperidone were monitored for over a period of 24 hr after the administration. $AUC_{0-t}$ (the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. The 90% confidence intervals for the log transformed data were within acceptable range of log 0.8 to log 1.25 (e.g., $log\;0.92{\sim}log\;1.05$ for $AUC_{0-t}$, $log\;0.81{\sim}log\;1.05$ for $C_{max}$). The major parameters, $AUC_{0-t}$ and $C_{max}$ met the criteria of KFDA for bioequivalence indicating that $Toriem^{(R)}$ tablet is bioequivalent to Motilium-$M^{(R)}$ tablet.

Relationship between Plasma Concentrations of Haloperidol and Its Metabolite, Reduced Haloperidol, and Clinical Response in Schizophrenia (정신분열증 환자에서의 Haloperidol 및 Reduced Haloperidol의 혈장농도와 임상반응과의 상관성)

  • Park, Kyung-Ho;Kim, Mu-Jin;Lee, Myung-Gul;Shim, Chang-Koo;Lee, Min-Hwa
    • Journal of Pharmaceutical Investigation
    • /
    • v.23 no.3
    • /
    • pp.165-177
    • /
    • 1993
  • The relationship between the plasma haloperidol (HP) concentration and clinical response, and the effects of its active metabolite, reduced haloperidol (RH) on clinical response of HP were investigated in schizophrenic patients. In clinical study I, with 17 schizophrenic patients (male 8, fermale 9) who were administered with three different fixed doses of HP (15, 30 and 50 mg/day) for 3 weeks, the concentrations of HP and RH in plasma and blood and clinical response had been checked before and every week during the study. The clinical response was evaluated by the method of brief psychiatric rating scale (BPRS), and relative improvement of clinical response based on baseline BPRS (before drug treatment) was calculated. The concentrations of HP and RH in plasma and blood were assayed by HPLC. In clinical study II, the plasma RH/HP concentration ratios were checked in 11 patients who were administered with high doses of HP, over 60 mg a day, because of the poor clinical response at usual doses of HP. Plasma HP concentration and relative improvement of BPRS at 3 week in schizophrenic patients showed a 'curvilinear' relationship, and the clinical response was improved relatively over 50% based on the baseline BPRS in the range of $5{\sim}57\;ng/ml $ of HP in plasma. Also, the plasma RH concentrations were increased nonlinearly as the plasma HP concentration increased, and in high plasma HP concentration, over 30 ng/mI, clinical response gradually decreased, while the plasma RH/HP concentration ratio increased nonlinearly. Blood partition coefficients of HP and RH were not changed according to daily HP dose and duration of drug therapy. From these results, it is noted that the higher plasma RH/HP concentration ratio, resulted from the accumulation of RH as HP concentration increased, might explain the 'curvilinear' decrease of HP clinical response.

  • PDF

Application of Viscometric Method for the Detection of Irradiated Black and White Pepper (방사선 조사된 후추가루의 검지를 위한 점도법의 적용)

  • Yi, Sang-Duk;Chang, Kyu-Seob;Yang, Jae-Seung
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.2
    • /
    • pp.114-121
    • /
    • 2000
  • A study was carried out to establish a detection method for irradiated black and white pepper. Samples were packed in polyethylene bags and irradiated with 2.5, 5, 7.5, 10 and 15 kGy using a Co-60 irradiator. The samples were suspended in water, and alkalized with sodium hydroxide solution. Apparent viscosity was determined after heat gelatinization using a Brookfield DV-III rotation viscometer at 30。C with 30, 60, 90, 120, 150, 180, and 210 rpm. Means and standard deviations of the viscosities of all samples decreased by increasing the stirring speeds. The viscosities increased in all samples by increasing the concentration. Regression expressions and coefficients of viscosity which decreased with increasing irradiation dose of 10% and 13% black pepper, and 7% and 10% white pepper were 0.9531 (y=-131.29x+1,769.0), 0.9725 (y=-351.33x+4,036.0), 0.9731 (y=2,208.0e${^-0.3546X}$), and 0.9959 (y=5,116.0e${^-0.2887X}$), respectively, at 120 rpm. This trend was similar fur all stirring speeds. These results suggest that the detection of irradiated black and white pepper at various doses is possible by the viscometric method.

  • PDF

Bioequivalence of Two Nilvadipine Tablet (닐바디핀 정제에 대한 생물학적 동등성 평가)

  • 김종국;이사원;최한곤;고종호;이미경;김인숙
    • Biomolecules & Therapeutics
    • /
    • v.6 no.3
    • /
    • pp.289-295
    • /
    • 1998
  • The bioequivalence of two nilvadipine products was evaluated in 16 normal male volunteers (age 22-32 yr, body weight 57-80 kg) following sidle oral dose. Test product was Overca $l_{R}$ tablet (Choong-Wae Pharm. Corp., Korea) and reference product was Nivadi $l_{R}$ tablet (Hyundai Pharm. Corp., Korea). Both products contain 4 mg of nilvadipine. One tablet of the test or the reference product was administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). The determination of nilvadipine was accomplished using a validated capillary column GC with electron-capture detection. As a result of the assay validation, the quantiflcation of nilvadipine in human plasma by this technique was possible down to 0.5 ng/ml using 1 ml of plasma. Absolute overall recovery from five replicate analyses of nilvadipine-spiked sample were 88.4$\pm$ 10.24% (mean$\pm$ 5.D.) for human plasma of 10 ng/ml. The coefficients of variation (C.V.) were less than 20% and the actual concentration of nilvadipine measured by GC ranged from 80 to 99% in all plasma. Average drug concentrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products (p>0.05); the area under the curve from time zero to 8 hr (AUCo-$_{8 hr}$) (22.8$\pm$5.90 vs 22.2$\pm$6.10 ng . hr/ml), maximum plasma concentration ( $C_{max}$) (10.0$\pm$2.85 vs 9.3$\pm$3.28 ng/ml) and time to reach maximum plasma concentration ( $T_{max}$) (1.2$\pm$0.31 vs 1.3 $\pm$0.47 hr). The differences of mean AU $Co_{8hr}$ $C_{max}$, and $T_{max}$ between the two products (2.25, 7.65, and 10.30%, respectively) were less than 20%. The power (1-$\beta$) and treaeent difference (7) for AU $Co_{8hr}$, and $C_{max}$ were more than 0.8 and less than 0.2, respectively. Although the power for Tmax was under 0.8, Tm\ulcorner of the two products was not significantly different from each other (p>0. 05). These results suggest that the bioavailability of Overeat tablet is not significantly different from that of Nivadil tablet. Therefore, two products are bioequivalent based on the current results.sults.lts.lts.lts.

  • PDF

Detection of Irradiated Agricultural Products by Thermoluminescence(TL) (Thermoluminescence(TL)를 이용한 농산물의 방사선 조사유무 확인)

  • Woo, Si-Ho;Yi, Sang-Duk;Yang, Jae-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.525-530
    • /
    • 2000
  • A study was carried out to establish the detection method of irradiated agricultural products cultivated in Korea by Thermoluminscece(TL). Samples were irradiated using Co-60 gamma rays at various doses(0.05, 0.1, 0.2, 0.3 and 0.5 kGy). After irradiation, separated minerals of the samples measured by TL. TL intensity increased with increasing doses and the irradiated samples were higher than the non-irradiated samples. TL first and second glow curves showed maximum TL temperature point at $176.16{\sim}190.08^{\circ}C$ and $143.84{\sim}146.56^{\circ}C$, respectively. All the irradiated samples can be classified correctly by the shape of the glow curve and the glow curve ratio. Correlation coefficients of ginger, carrot, potato and sweet potato were 0.9968, 0.8522, 0.9612 and 0.9071, respectively, that showed very high correlation between irradiation dose and TL intensity. Therefore, these results suggest that TL measurement is an useful detection method for irradiated agricultural products.

  • PDF

A Feasibility study on the Simplified Two Source Model for Relative Electron Output Factor of Irregular Block Shape (단순화 이선원 모델을 이용한 전자선 선량율 계산 알고리듬에 관한 예비적 연구)

  • 고영은;이병용;조병철;안승도;김종훈;이상욱;최은경
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.21-26
    • /
    • 2002
  • A practical calculation algorithm which calculates the relative output factor(ROF) for irregular shaped electron field has been developed and evaluated the accuracy of the algorithm. The algorithm adapted two-source model, which assumes that the electron dose can be express as sum of the primary source component and the scattered component from the shielding block. Original two-source model has been modified in order to make the algorithm simpler and to reduce the number of parameters needed in the calculation, while the calculation error remains within clinical tolerance range. The primary source is assumed to have Gaussian distribution, while the scattered component follows the inverse square law. Depth and angular dependency of the primary and the scattered are ignored ROF can be calculated with three parameters such as, the effective source distance, the variance of primary source, and the scattering power of the block. The coefficients are obtained from the square shaped-block measurements and the algorithm is confirmed from the rectangular or irregular shaped-fields used in the clinic. The results showed less than 1.0 % difference between the calculation and measurements for most cases. None of cases which have bigger than 2.1 % have been found. By improving the algorithm for the aperture region which shows the largest error, the algorithm could be practically used in the clinic, since one can acquire the 1011 parameter's with minimum measurements(5∼6 measurements per cones) and generates accurate results within the clinically acceptable range.

  • PDF