• 제목/요약/키워드: Dose Reduction

검색결과 1,449건 처리시간 0.024초

만성 정신분열병 환자에서 항정신병약물 감량에 관한 연구 (A Study for Dose-Reduction of Antipsychotics in Chronic Schizophrenics)

  • 황태연;이민수;김형섭
    • 생물정신의학
    • /
    • 제5권2호
    • /
    • pp.263-277
    • /
    • 1998
  • Conventional high-dose antipsychotics tend to result in more side effects, negative symptoms and dysphoria, and at the same time lower the cognitive function which is already impaired in most schizophrenics. Florid psychotic symptoms, negative symptoms and cognitive impairment greatly impede psychosocial performance and eventual reintegration into society. The reduction of symptom and the improvement of cognitive funtions and social skills are therefore central to the psychiatric rehabilitation process. The purpose of this study was to evaluate the dose-reduction effects of antipsychotics on chronic schizophrenics prescribed conventional high-dose antipsychotics more than 1,500mg equivalent of chlorpromazine. Fifty-one chronic schizophrenics who maintained high-dose antipsychotics for more than three months were randomly assigned to two groups : 20 patients comprised the dose-maintaining group and 31 patients made the dose-reduction group. Over a sixteen weekperiod Positive and Negative Syndrome Scale(PANSS), Extrapyramidal Symptom(EPS), Nurses' Observation Scale for Inpatient Evaluation(NOSIE-30), Continuous Performance Test(CPT), Quality of Life(QOL), and haloperidol/reduced haloperidol blood levels were determined at the base line and after 2, 4, 6, 8, 12, 16 weeks to evaluate the dose reduction effects of high-dose antipsychotics. The results were as follows : 1) Dose-reduction is highly effective in reducing positive and negative symptoms, and general psychopathology. Effects were most prominent at 8, 12, 16 weeks. Among the dose reduction group, positive symptoms in positive symptom group and negative symptoms in negative symptom group were more reduced. 2 Extrapyramidal symptoms showed no significant difference between two groups. But the EPS was reduced time after time within two groups. 3) Hit rates of Continuous Performance Test, which indicate attentional capacity, increased significantly after dose reduction. 4) Haloperidol and reduced haloperidol blood levels decreased until the 4th week, after which they were constant. 5) Total scores of Nurses' Observation Scale for Inpatient Evaluation were unchanged between the two groups. But among the indices, social interest and personal neatness were improved in the dose-reduction group and retardation was aggrevated in the dose-maintaining group. 6) Total quality of life scores were unchanged between two groups. But in the dose maintaining group, satisfaction scores of attention, autonomy, and interpersonal relationship decreased progressively. These findings suggest that the dose reduction of antipsychotics for chronic schizophrenics on programs of high-dose antipsychotics were effective. Dose reduction should therefore be implemanted to spread the rehabilitation and improve quality of life for chronic schizophrenics.

  • PDF

증기발생기 수실 노즐댐 설치 및 제거작업의 피폭선량 저감에 영향을 주는 관리요인에 관한 연구 (Managerial Factors Influencing Dose Reduction of the Nozzle Dam Installation and Removal Tasks Inside a Steam Generator Water Chamber)

  • 이동하
    • 대한인간공학회지
    • /
    • 제36권5호
    • /
    • pp.559-568
    • /
    • 2017
  • Objective: The aim of this study is to investigate the effective managerial factors influencing dose reduction of the nozzle dam installation and removal tasks ranking within top 3 in viewpoint of average collective dose of nuclear power plant maintenance job. Background: International Commission on Radiation Protection (ICRP) recommended to reduce unnecessary dose and to minimize the necessary dose on the participants of maintenance job in radiation fields. Method: Seven sessions of nozzle dam installation and removal task logs yielded a multiple regression model with collective dose as a dependent variable and work time, number of participants, space doses before and after shield as independent variables. From the sessions in which a significant reduction in collective dose occurred, the effective managerial factors were elicited. Results: Work time was the most important factor contributing to collective dose reduction of nozzle dam installation and removal task. Introduction of new technology in nozzle dam design or maintenance job is the most important factor for work time reduction. Conclusion: With extended task logs and big data processing technique, the more accurate prediction model illustrating the relationship between collective dose reduction and effective managerial factors would be developed. Application: The effective managerial factors will be useful to reduce collective dose of decommissioning tasks as well as regular preventive maintenance tasks for a nuclear power plant.

Long-term Radiation Dose Reduction Plan of KHNP

  • Kim, Saeng-Ki;Shin, Sang-Woon;Lim, Byoung-Chan
    • Journal of Radiation Protection and Research
    • /
    • 제28권2호
    • /
    • pp.137-143
    • /
    • 2003
  • Annual radiation dose limit to radiation worker was substantially lowered in Korea by the adoption of 1990 recommendations of the International Commission on Radiation Protection (ICRP 60) in its legislation. On the other hand, radiation management environment in nuclear power plants is getting more worse because of the accumulation of radiation sources inside the system and the frequent need for maintenance according as the operation years of nuclear power plants increase. Therefore, Korea Hydro & Nuclear power Co., Ltd. (KHNP) has established a long-term 10 years plan from 2001 to 2010 for the reduction of radiation dose to workers. The plan is aimed for the reduction of annual dose per unit averaged over 5 years from 0.9 man-Sv in 2001 to 0.75 man-Sv in 2010 by radiation source reduction, equipment/tool improvement or new equipment development for easy maintenance, and the improvement of administration and system.

안와 전산화단층촬영검사 시 수정체 선량감소 방법과 영상 평가 (Lens Dose Reduction Methods and Image Quality in Orbital Computed Tomography Scan)

  • 문세영;홍상우;서지숙;김영범;곽완신;이성영;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.343-351
    • /
    • 2020
  • This study analyzed dose reduction and quality of images through dose reduction tools and shielding board to protect sensitive eye lens in radiation during orbit CT examinations for clinical data use. During CT scans of the phantom, surface dose (CT scanner dosimetry phantom, ion chamber-3 times) and quality of image (radiosurgery head phantom, visual assessment-2 times, HU standard deviation) were evaluated using X-care which is dose reduction tools and bismuth shielding board. The results of experiments of eight conditions showed a relatively reduced dose in all other conditions compared to when no conditions were set. In particular, the area corresponding to the ophthalmic part reduced the surface dose by up to 45.7 %. The visual evaluation of images by specialists and the quality evaluation of images analyzed by HU standard deviation were clinically closest to the use of X-care and shielding board (1 cm in height). Therefore, it is believed that the use of shielding board in a suitable location with dose reduction tools while investigating the optimal radiation dose will reduce the exposure dose of sensitive lens at radiation while maintaining the quality of the images with high diagnostic value.

C-arm을 이용한 EVAR(Endovascular Aneurysm Repair) 시술시 Lead Curtain 설치에 따른 Staff의 피폭선량 감소에 대한 연구 (The investigation of the exposure dose reduction of the Staff according to the Lead Curtain installation in EVAR(Endovascular Aneurysm Repair) surgical operation using C-arm)

  • 유인웅;정재연;이관섭
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.33-38
    • /
    • 2012
  • In EVAR procedure using long time C-arm, we studied exposure dose reduction and effeciency through measuring surgical staff's ESD by installing lead curtain operating table next to. The height 3 the spot (50cm, 100cm, 150cm) dose was measured on 2 locations for 600sec in the X-ray radiation considering the surgical staff's movement. To install the curtains, we compared before and after the dose. As a result, it can confirm that dose of the installation former of 50cm height and after is reduced about 75% and 91% in 2 locations. In 100cm height, the reduction of the dose was a bit confirmed. There as to dose value, measured on 150cm height the installation former and after was nearly no change. This research examined the exposure dose about the radiation of the surgical staff during EVAR procedure in which the operation time is the long time. It was implemented in the object that it reduces the radiation exposure. It could confirm the certain effect of the experimental result exposure dose reduction In EVAR procedure using long time C-arm, we studied exposure dose reduction and effeciency through measuring surgical staff's ESD by installing lead curtain operating table next to. The height 3 the spot (50cm, 100cm, 150cm) dose was measured on 2 locations for 600sec in the X-ray radiation considering the surgical staff's movement. To install the curtains, we compared before and after the dose. As a result, it can confirm that dose of the installation former of 50cm height and after is reduced about 75% and 91% in 2 locations. In 100cm height, the reduction of the dose was a bit confirmed. There as to dose value, measured on 150cm height the installation former and after was nearly no change. This research examined the exposure dose about the radiation of the surgical staff during EVAR procedure in which the operation time is the long time. It was implemented in the object that it reduces the radiation exposure. It could confirm the certain effect of the experimental result exposure dose reduction.

  • PDF

제조사별 다중 검출기 컴퓨터단층촬영 장비의 관전류 자동노출조절 기법의 방사선량 감소 평가 (Evaluation of Radiation Dose Reduction from the Automatic Exposure Control Technique in Different Manufactures Multi-Detector Computed Tomography)

  • 김영옥;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 추계학술대회
    • /
    • pp.563-571
    • /
    • 2011
  • The purpose of the study was to evaluation of the radiation dose reduction using various automatic exposure control (AEC) systems in different manufactures multi-detector computed tomography (MDCT). We used three different manufacturers for the study: General Electric Healthcare, Philips Medical systems and Siemens Medical Solutions. The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using body phantom. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the GE, 58.2% in the Philips, and 48.6% in the Siemens. This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.

  • PDF

INSTORE : A PC-Based Database Program for Occupational Radiation Exposure of a Nuclear Power Plant

  • Cho, Yeong-Ho;Kang, Chang-Sun;Mun, Ju-Hyung;Kim, Hak-Su
    • Nuclear Engineering and Technology
    • /
    • 제30권4호
    • /
    • pp.308-317
    • /
    • 1998
  • Ensuring occupational radiation exposure(ORE) as low as is reasonably achievable(ALARA) has been one of very important requirements in a nuclear power plant. It is well known that about 70 percent of occupational dose has incurred from maintenance jobs in the outage period. To reduce occupational dose effectively, the high-dose jobs in the outage period should be identified with their dose reduction potentials and methods. In this study, a PC-based ORE database program, INSTORE, is developed to evaluate ORE doses in individual jobs, and the ORE data of Kori Units 3 and 4 are assembled to the database. Based on customary job classification, radiation work is classified into 26 main jobs which comprise 61 detailed jobs, and occupational doses are assessed according to each detailed job. As a result, high-dose jobs are identified with dose reduction priority in terms of collective ORE dose. It is recommended that adeqaute dose reduction methods for these jobs should be prepared to improve their working conditions and procedures.

  • PDF

전산화 단층검사 시 Bismuth와 CARE kV System을 이용한 선량 저감화에 대한 연구 (Research on Dose Reduction During Computed Tomography Scanning by CARE kV System and Bismuth)

  • 곽영곤;김종일;정성표
    • 한국콘텐츠학회논문지
    • /
    • 제14권8호
    • /
    • pp.233-242
    • /
    • 2014
  • 본 논문에서는 전산화 단층검사 시 방사선 투과 물질로 방사선량을 흡수하여 피폭 선량을 감소시키는 물질로 알려진 차폐용 Bismuth(비스무스)와 CARE kV(Automated Dose-Optimized Selection of X-ray Tube Voltage)을 사용하여 유용성을 평가하였다. 방사선 감수성이 높은 기관인 수정체(안와), 갑상선, 가슴(유방), 생식기의 선량 감소 효과와 각 기관의 심부선량 차폐 효과를 평가하기 위해 Rando Phantom과 유리 선량계를 이용하여 Bismuth 사용 전 후와, CARE kV의 적용에 따른 선량 감소 효과를 비교해 보았다. 그 결과, 뇌혈관 검사 시 CARE kV을 단독 설정한 검사 방법의 선량이 가장 적었으며, CARE kV 사용여부에 따라 63%의 선량 감소 효과가 있었다. 경동맥 검사 시 CARE kV+Bismuth의 설정 방법에서 선량이 13% 증가하였다. 심혈관 검사 시 CARE kV+Bismuth의 설정 방법이 31% 선량 감소 효과가 있었다. 하지 혈관 검사 시 Bismuth 전체의 설정 방법이 가장 선량이 적게 측정되었지만, 영상 평가 기준에 부적합 하였다. CARE kV을 설정한 검사 방법과는 약 9%의 선량 감소 효과가 있었다.

64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소 (Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols)

  • 김문찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.299-306
    • /
    • 2009
  • MDCT의 시간분해능 향상과 등방성 해상능(isotrophic resolution) 영상의 획득, 그리고 지능적인 심전도 동조를 바탕으로 하여 심혈관 질환의 효과적인 진단검사로 인정받고 있는 후향적 심전도 동조화(retrospective ECG gating) 하의 coronary CT angiography는 상대적으로 많은 환자선량을 제공함으로 인해 우수한 진단방법으로서의 장점을 반감시키고 있다. 이에 각 장치 제조사에서는 환자선량을 감소시키는 방법의 연구가 활성화되어 왔으며, 이의 일환으로 지능적인 cardiac dose modulation 기술과 전향적 심전도 동조화(prospective ECG gating)를 사용한 sequential scan이 도입되고 있다. 이에 본 연구에서는 64 채널 MDCT에서 54 kg, 163 cm인 여성 인체모형팬텀을 대상으로 하고 형광유리선량계를 사용하여 후향적 심전도 동조화 하의 coronary CT angiography 프로토콜에서 환자선량의 정량적 평가와 환자선량 감소를 위해 본원에서 선택적으로 적용하고 있는 5가지 검사 프로토콜을 적용하였을 경우의 effective dose와 중요 부위의 organ dose를 측정 비교하여 다음과 같은 결과를 얻었다. 1) Dose modulation없이 120 kVp와 210 mAs의 노출조건으로 retrospectively ECG gated helical scan으로 시행한 conventional coronary CT angiography 프로토콜의 effective dose는 17.8 mSv였으며, 심장의 organ dose는 103.8 mGy였다. 2) 관전압을 120 kVp에서 100 kVp로 낮추었을 경우 effective dose는 11.0 mSv로 conventional coronary CT에 비해 38.2%가 감소하였으며, 심장은 67.3 mGy로 45.2%가 감소하였다. 3) Cardiac dose modulation을 적용한 경우 effective dose는 13.3 mSv로 conventional coronary CT에 비해 25.3%가 감소하였으며, 심장은 80.0 mGy로 22.9%가 감소하였다. 4) 100 kVp의 저관전압과 cardiac dose modulation을 적용한 경우 effective dose는 8.1 mSv로 conventional coronary CT angiography에 비해 54.5%가 감소하였으며, 심장은 49.5 mGy로 52.3%가 감소하였다.

  • PDF

인터벤션 시술 시 환자의 선량감소를 위한 3D 프린팅 재료의 적용성 평가 (Feasibility of the 3D Printing Materials for Radiation Dose Reduction in Interventional Radiology)

  • 조용인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권3호
    • /
    • pp.169-176
    • /
    • 2020
  • Interventional radiology is performed under real-time fluoroscopy, and patients are exposed to a wide range of exposures for a long period of time depending on the examination and procedure. However, studies on radiation protection for patients during an intervention are insufficient. This study aims to evaluate the doses exposed during the intervention and the applicability of 3D printing materials. The organ dose for each intervention site was evaluated using a monte carlo simulatio. Also, the dose reduction effect of the critical organs was calculated when using a shielding device using 3D printing materials. As a result, the organ dose distribution for each intervention site showed a lower dose distribution for organs located far from the x-ray tube. It was analyzed that the influence of scattered rays was higher in the superficial organs of the back of the human body where x-rays were incident. The dose reduction effect on the critical organ using the 3D printing shield showed the highest testis among the gonads, and in the case of other organs, the dose reduction effect gradually decreased in the order of the eye, thyroid, breast, and ovary. Accordingly, it is judged that the 3D printed shield will be sufficiently usable as a shielding device for the radiation protection of critical organs.