• Title/Summary/Keyword: Dose Rate

Search Result 3,201, Processing Time 0.032 seconds

The Estimation of the Coagulant on Method of Lime Input in the Water Treatment Plant at High Turbidity (고탁도시 소석회 투입방법에 따른 정수장 응집제의 효율 평가)

  • Bang, Mi Ran;Lim, Bong Su;Bae, Byung Uk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.107-117
    • /
    • 1998
  • In order to removal turbidity at high turbidity, this study was carried to evaluate the coagulants(Alum, PACl, PACS) that was suited the characteristics of raw water in water treatment plants and to determinate the optimum method of lime feed. When the optimum coagulant was selected the organic matter removal was also investigated as $UV_{254}$. PACl, lime first feed had the highest turbidity removal efficiency rate as above 99.1% and then $UV_{254}$ removal rate was obtained over than 88.0%. If you had the necessary of the lime feed, among the method of lime feed time interval feed largely was improved than simultaneous feed. Also, lime feed dose had about 1/5 of coagulants dose in case of Alum and PACl, but always PACS should be considerated lime dose.

  • PDF

A Study on the Controlled Release of Naproxen from Hydrophilic Polymer Matrix (친수성고분자 매트릭스의 Naproxen 제어방출에 관한 연구)

  • 김종국;조은실
    • YAKHAK HOEJI
    • /
    • v.31 no.1
    • /
    • pp.25-32
    • /
    • 1987
  • The effect of loading dose, plasticiser and PVA molecular weight on naproxen release from hydrophilic polymer matrix was examined. Hydrophilic polymer matrix was prepared with PVA and PVP by adding glycerine as plasticiser. The release of naproxen from polymer matrix was determined in phosphate buffer medium. The release rate of naproxen from the polymer matrix increased as drug loading dose and plasticiser percentage increased. Raproxen released from the polymer matrix showed the time square root kinetics. Without changing the release-pattern, the release rate of naproxen could not be changed by varying molecular weight of PVA. Linearly released time range increased as drug loading dose increased, whereas decreased as plasticiser percentage increased up to 30%.

  • PDF

A High Dose-rate Gamma Irradiation of the High Brightness Power LED (고휘도 Power LED 의 고선량 감마선 조사 특성)

  • Cho, Jai-Wan;Choi, Young-Soo;Shin, Jung-Cheol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.243-247
    • /
    • 2009
  • A Radioactive constraint of the nuclear fuel assembly irradiated by neutron during normal operation cycle of the nuclear power plant is typically on the order of about 3 kGy/h. In order to inspect nuclear fuel assembly using a VT (vision technology) system, the light such as halogen lamp is used. As the halogen lamp has lower color temperature than the sun light, the objects under halogen lamp illumination are seemed to be tinted with red. In this paper, high brightness LED is considered to be used as the light source of VT system. The high brightness LED, which is a key light source of the VT system, have been gamma irradiated at the dose rate of 4 kGy/h during two hours up to a total dose of 8 kGy. The radiation induced color-center in the LED housing cap made of plastics materials is observed.

  • PDF

Study on the Thermal Properties of the Gamma-ray Irradiated EVA/MWCNT Nanocomposites

  • Lee, Kyoung-Yong;Kim, Ki-Yup;Hwang, In-Ra
    • Journal of Radiation Industry
    • /
    • v.3 no.1
    • /
    • pp.31-37
    • /
    • 2009
  • This paper describes the preparation of manufacturing a new nanocomposite material, which involves adding a multi walled carbon nanotube (MWCNT) to improve thermal characteristics of poly (ethylene-co-vinyl acetate) (EVA). We irradiated the prepared nanocomposites with doses of 50 kGy, 100 kGy and 200 kGy at a dose rate of $5kGy\;hr^{-1}$ and examined their thermal stability, activation energy and crosslink level by using a thermogravimetric analyzer (TGA) and gel fraction experiments. TGA results indicated that the samples with a MWCNT had higher Derivative Thermo Gravimetry (DTG) 2nd peak temperatures than those without a MWCNT. And activation energy of the samples reduced as the absorption dose and the MWCNT content increased. Finally, the gel fraction increased rapidly up to 100 kGy as total absorption dose increased, and then the growth rate of all samples was slowly increased from 100 kGy.

Characteristics of Specific Absorption Rate (SAR) in Electromagnetic (EM) Dosimetry

  • Hwang, Sun-Tae;Choi, Kil-Oung
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.2
    • /
    • pp.109-114
    • /
    • 2000
  • The SI unit of specific absorption rate (SAR) in W/kg in the electromagnetic (EM) field as non-ionizing radiation is exactly same as the SI unit of absorbed dose rate in Gy/s in the ionizing radiation field. The SI unit of both physical quantities can be expressed in $[m^{\cdot}s^{-3}]$. Where, the unit of absorbed dose, Gy stands for Gray. In EM biological interactions, the SAR equations are derived and the characteristics of EM field energy absorption in terms of the SAR are discussed and described on the mathematical basis.

  • PDF

Studies on the Antihypertensive Effect of Clonidine Administered Concurrently with Labetalol or Metoprolol in SHR (SHR에 Clonidine을 Labetalol 또는 Metoprolol과 병용투여후의 혈압강하에 관한 연구)

  • 허인회;김동섭;이종흔
    • YAKHAK HOEJI
    • /
    • v.26 no.2
    • /
    • pp.105-110
    • /
    • 1982
  • The antihypertensive effect of clonidine administered concurrently with labetalol or metoprolol were studied with spontaneously hypertensive rats (SHR). The changes of heart rate were also observed in the same rats. Every drug was orally administered single dose after prechecking the systolic blood pressure and heart rate of SHR. The blood pressure of SHR in concurrently administered group was more significantly decreased than in alone administered group. The effective and stable decrease of blood pressure was maintained at the group of clonidine with labetalol (0.05+50mg/kg) for 9 hours. The group of clonidine with metoprolol (0.05+100mg/kg) manifested more marked decrease of blood pressure than the group of metoprolol (100mg/kg) alone for 9 hours. The diminishing effect of heart rate was enhanced in group of administering clonidine with labetalol, decreasing the dose of labetalol from 50mg/kg via 25mg/kg to 12.5mg/kg. On the other hand, in the group that clonidine was administered concurrently with metoprolol, the diminishing effect of heart rate was decreased with decreasing doses of metoprolol from 100mg/kg via 50mg/kg to 25mg/kg.

  • PDF

Effect of Low-Dose Gamma Radiation to Enhance Germination Rate in Bottle Gourd and Pumpkin Seeds (참박과 호박 종자의 발아촉진을 위한 저선량 감마선의 효과)

  • Kim, Jae-Sung;Baek, Myung-Hwa;Lee, Young-Keun;Lee, Hae-Youn;Yoo, Jun-Cheol
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.3
    • /
    • pp.202-207
    • /
    • 2002
  • To establish the seed treatment method of the gamma radiation for germination enhancement of bottle gourd(Lagenaria siceraria Standl.) and pumpkin(Cucurbita ficifolia Bouche), seeds were irradiated with the dose of 1$\sim$20 Gy of the gamma radiation. The germination rate in irradiated group was higher than that of the control, depending on seed condition. In the case of bottle gourd, the germination rate of 70$\sim$80% germinative seed was increased at 4$\sim$20 Gy irradiated groups. Especially, it was the highest at 4 Gy irradiated group. The germination rate of 80$\sim$90% germinative seed was the highest at 4 Gy irradiated group. The germination rate of 70$\sim$80% and 80$\sim$90% germinative seed at 4 days after sowing was increased 66% and 26% at 4 Gy irradiated group, respectively. In the case of pumpkin, the germination rate of 70$\sim$80% and 80$\sim$90% germinative seed was increased at 2 Gy and 8 Gy irradiated group, respectively. Effect of the low-dose gamma radiation on the early growth was enhanced depending on their germination enhancement. Especially, it was the highest at 2 Gy irradiated group of 70$\sim$80% germinative seed of pumpkin. Catalase activity of bottle gourd was increased at 4 Gy irradiated group. Catalase and peroxidase activity of pumpkin were increased at 2 Gy and 8 Gy irradiated group. These results suggest that the germination, early growth and physiological activity of bottle gourd and pumpkin seeds could be promoted by the low dose gamma radiation.

Improvement of Mutation Rate and Reduction of Somatic Effects by Double Treatment of Chemical Mutagens in Barley (화학 돌연변이제 이중처리에 의한 돌연변이율 향상 및 생장저해 경감)

  • 구본철
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.3
    • /
    • pp.348-353
    • /
    • 1996
  • Mutation tachniques inducing more useful mutations and reducing somatic effects need to be improved for crop breeding. Seeds of barley varieties ; Dema, Grosso were treated with two types of mutagens ; 1) chemical treatment: single treatment or double treatment of two mutagens (N-nitroso-N-methylurea ; MNH, Sodium Azide; NaN$_3$) 2) gamma ray irradiation treatment. After treatment, half of seeds were used for germination test and half of seeds were sown to the field. With the higher dose of mutagen both chemical and gamma ray were plants treated, the higher rate of growth reduction rate was in M$_1$ seedling. In chemical treatment, germination rate of seeds, growth rate of coleoptile and root in double treatment of chemical mutagens were better than single treatments, especially in same dose. Growth inhibition rate of plant in double treatment of 1.0mM MNH(0.5mM MNH + 0.5mM MNH), for example, were less than one of plants of single treatment of 1.0mM MNH in pot and petri dish test. Growth reduction rate of culm and fertility rate in M$_1$ plants double treated in same dose of single treatment were also less than single one. With the higher dose of mutagen both chemical and gamma ray were plants treated, the higher frequency of chlorophyll mutants was in M$_2$ seedling. The rate of chlorophyll mutants in double treatment of chemical mutagens were higher than single treatment. Double treatment methods can be a improved method for induction of new good mutants, which were induced more useful mutations and reduced harmful somatic effects.

  • PDF

Variation of Dose due to the Wound Electrode of Ionization Chamber (굴곡이 있는 전리함 집전극에 기인한 선량 변화)

  • Lee, Byung-Koo;Kim, Jung-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.203-209
    • /
    • 2008
  • Nowadays the risk of radiation is getting more serious, so we must know the exact dose that was irradiated, Because very high radiation dose is used in radiation therapy field. We used the ionization chamber which measure the radiation dose in this study. We tried to know the incorrect result from the distortion of geometric structure of ionization chamber and we studied how to find the distortion of geometric structure of ionization chamber. We used a radio fluoroscopy to find the wound degree of electrode of ionization chamber and a reconstructed 3D CT image to analyze the wound degree of electrode quantitatively. we measured degree of distortion by comparing with absorbed dose of normal electrode and wound electrode. The comparative result is not absolute dosimetry at specific point but relative dosimetry between thats. We measured 4 MV, 10MV photon with same absorbed dose and dose rate. The degree of distortion of wound electrode was totally $5.5{\sim}7.2%$, and there was no difference between two energies. The variation induced from radiation dose to be irradiated and dose rate, and the degree of distortion from wound direction also was almost similar value. We could find that the geometric structure of ionization chamber that can influence a basic measurement of radiation dose can be changed by old usage and inattention of management in this study, especially winding of electrode can be happened, in radiation therapy field, It is very important to keep precise radiation dose quantitatively.