• 제목/요약/키워드: Doppler center

검색결과 269건 처리시간 0.027초

30${\sim}$40대 한국 여성의 안색과 혈행의 상관성 연구 (The correlation of the skin color to the blood circulation on the face of Korean female between the ages of 30 and 45)

  • 김은주;노호식;김수정;문은정;김덕희;김한곤;조가영
    • 대한한의정보학회지
    • /
    • 제14권2호
    • /
    • pp.73-79
    • /
    • 2008
  • Objectives : We investigated the correlation of the skin color to blood circulation on the face of Korean female by noninvasive-skin measuring devices. Methods : Korean female(37.47${\pm}$3.66 years, n=36) aged 30-45 years were participated in this study. We measured the skin color of the face with Spectrophotometer CM2600d (Minolta, Japan) and the skin blood flow with Laser Doppler Imaging-Periscan PIM II (Perimed AB, Sweden). The skin color and blood circulation of three groups (30-35 years, 36-40 years, 41-45 years) divided on age were analyzed by paired-t test and regression analysis. Results : The L* values of the skin were decreased and the a* values were increased significantly with age. This means that the more age increase, the more the skin is dark and red. But the skin blood flow was not significantly different with age and skin color. Conclusions : In the oriental medicine, It was reported that the face of the female over 35 years is changed gradually haggard and the blood circulation is decreased. In our study, the blood circulation was not changed and the skin color was dark and red with increasing the age. We think this symptom resulted from the better nutrition than the past, the change of the blood-quality and this changes were too sensitive to be measured by Laser Doppler Imaging system.

  • PDF

반복적인 실신 및 실신전환자의 기립경사 검사시 경두개 초음파 감시 (Transcranial Doppler Ultrasonography Monitoring during Head-up Tilt Test in Patients with Recurrent Syncope and Presyncope)

  • 조수진;이광호;정진상
    • Annals of Clinical Neurophysiology
    • /
    • 제1권1호
    • /
    • pp.64-69
    • /
    • 1999
  • Background : Syncope was defined as transient loss of consciousness and postural tone. The mechanisms of changes in cerebral hemodynamics during syncope have not been fully evaluated. Transcranial Doppler Ultrasonography can continuously monitor the changes in cerebral hemodynamics during head-up tilt (HUT). TCD could reveal the different patterns of changes in cerebral hemodynamics during syncope. Syncope without hypotension or bradycardia could be detected by TCD. We investigated the changes in cerebral blood flow velocity during HUT using TCD in 33 patients with a history of recurrent syncope or presyncope of unknown origin. Methods & Results : The positive responses were defined as presyncope or syncope with hypotension, bradycardia, or both. During HUT without isoproterenol infusion, there were a $86{\pm}23%$ drop in DV and a $41{\pm}34%$ drop in SV in 5 patients with positive reponses, and mean changes in those were less than 10% in patients with negative reponses (p=.00, p=.00). During HUT with isoproterenol infusion, TCD showed a $80{\pm}18%$ drop in diastolic velocity in 14 patients with positive reponses, and a $47{\pm}10%$ drop in that in patients with negative reponses (p=.00), however the change in systolic velocity did not differ. TCD showed three patterns during positive responses; loss of all flow, loss of end diastolic flow, and a decrease in diastolic velocity. Loss of consciousness occurred in the patients with loss of all flow or end-diastolic flow during positive reponses. Conclusions : TCD shows different patterns of changes in cerebral hemodynamics during HUT. TCD can be used to investigate the pathophysiology of neurocardiogenic syncope.

  • PDF

위상 샘플방식 DRFM을 이용한 VGPO/VGPI 속도기만 재밍기법 구현 (Implementation of VGPO/VGPI Velocity Deception Jamming Technique using Phase Sampled DRFM)

  • 김요한;문병진;홍상근;성기민;전영일;나인석
    • 한국정보통신학회논문지
    • /
    • 제25권7호
    • /
    • pp.955-961
    • /
    • 2021
  • 현대전에서는 전파를 이용하여 적의 정보를 알아내거나, 적이 탐지하려는 아군 정보를 보호하는 임무를 수행하는 전자전 분야의 중요성이 증가하고 있다. 전자전 분야의 대표적인 전자공격 방법 중 하나인 레이다 재밍기법은 적 레이다를 교란 및 기만하여 아군의 위치 정보가 노출되는 것을 방지한다. 레이다 재밍기법 중 하나인 속도기만 재밍기법은 도플러효과를 이용하여 표적의 속도와 위치를 추적하는 펄스 도플러 레이다를 대상으로 사용된다. 속도기만 재밍기법은 DRFM (Digital Radio Frequency Memory)을 이용하여 수신신호를 주파수 변조해서 송신하는 방법으로 구현할 수 있다. 본 논문은 위상 샘플방식 DRFM을 이용하여 속도기만 재밍기법 중 하나인 VGPO/VGPI 재밍기법을 구현하는 방안을 기술하고, 제작한 보드를 통해서 주입신호 환경 하에서 VGPO/VGPI 재밍기법의 동작을 검증하였다.

정상인의 한냉자극에 대한 심박변이도 및 도플러 초음파 혈류계를 이용한 말초 혈류관찰 (Clinical Observation on Heart Rate Variability and Peripheral Blood Flow by Doppler Ultrasound in Healthy Subjects Stimulated by Cold Stress)

  • 임성근;이상훈;배영민
    • 대한한의학회지
    • /
    • 제31권2호
    • /
    • pp.114-123
    • /
    • 2010
  • Objectives: This study was performed to investigate the effect of cold stress on heart rate variability and peripheral blood flow by Doppler ultrasound in healthy subjects. Methods: We classified the subjects by their Yin or Yang tendency using a Yin-Yang questionnaire. Cold stress was taken on the left hand of subjects for 10 seconds. Heart rate variability and peripheral blood flow were measured on the right radial artery before and after cold stress. Results: The Yang tendency group showed a significant decrease of heart rate after cold stress which was not seen in the Yin tendency group. The Yang tendency group showed a decrease of LF, total power, and increase of HF after cold stress, while the Yin tendency group showed the opposite. However, there were no statistically significant differences of heart rate variability analysis between the results of the two groups before and after cold stress. Recovery time of blood flow velocity by ultrasound Doppler was significantly different between the Yin and Yang tendency groups after cold stress. Conclusion: These results suggest that people with Yin or Yang tendency may show different responses in the autonomic nervous system. Further modified studies may include the responses to various manipulation techniques in acupuncture treatment and the individual responses according to pattern identification in traditional Korean medicine.

무선통신 도플러 주파수를 이용한고속열차 위치 추정에 관한 연구 (A Study on the High Speed Train Localization Using Doppler Frequency in the Wireless Communication)

  • 김정태
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.826-833
    • /
    • 2017
  • 열차의 위치를 정확하게 추정하는 것은 열차제어를 위해 필수적이며 선로변에 시스템을 설치하지 않고 열차의 위치를 추정하기 많은 연구가 있었다. 열차는 선로 위를 움직이므로 위치 추정을 일차원적으로 검색이 가능하며 그 선로 또한 위치 정보를 미리 알 수 있다는 특징이 있다. 특히 고속열차의 경우 속도가 커서 도플러 주파수가 비교적 크며 선로 모양도 직선 혹은 반경이 큰 곡선으로 되어 있다. 본 연구에서는이를 활용하여 두 지점(기지국)에서 송신한 신호의 도플러 주파수를 이용하여 열차의 위치를 추정하는 방안에 대하여 제안한다. 직선과 곡선, 직곡선 혼합 선로 구간에 대하여 위치를 추정하는 수식을 도출한다. 일반적으로 도플러 레이더는 속도를 측정하는데 사용되나 여기에서는 속도와 위치를 모르는 상태에서 두 신호의 도플러 주파수 비율을 이용하여 위치와 속도를 순차적으로 구한다. 시뮬레이션을 통해 열차 위치 및 측정 오차 수준에 따른 추정 오차의 변화를 구한다. 제안하는 방안과 기존 방안에서의 목표 추정 오차 수준을 얻기 위한 조건과 측정 오차가 커짐에 따른 오차의 증가량을 비교함으로써 성능과 강인성 면에서 제안하는 방안의 우수성을 보인다.

Doppler Shifts of the $H{\alpha}$ Line and the Ca II 854.2 nm Line in a Quiet Region of the Sun Observed with the FISS/NST

  • 채종철;박형민;양희수;박영득;조경석;안광수
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.113.1-113.1
    • /
    • 2012
  • The characteristics of Doppler shifts in a quiet region of the Sun are investigated by comparing between the $H{\alpha}$ line and the Caii infrared line at 854.2 nm. A small area of $16^{\prime\prime}{\times}40^{\prime\prime}$ was observed for about half an hour with the Fast Imaging Solar Spectrograph (FISS) of the 1.6 meter New Solar Telescope (NST) at Big Bear Solar Observatory. The observed area contains a network region and an internetwork region, and identified in the network region are $H{\alpha}$ fibrils, Caii fibrils and bright points. We infer the Doppler velocity from each line profile at a point with the lambdameter method as a function of half wavelength separation ${\Delta}{\lambda}$. It is confirmed that the bisector of the spatially-averaged Caii line profile has an inverse C-shape of with a significant peak redshift of +1.8 km/s. In contrast, the bisector of the spatially-averaged $H{\alpha}$ line profile has a different shape; it is almost vertically straight or, if not, has a C-shape with a small peak blueshift of -0.5 km/s. In both the lines, the bisectors of bright network points are much different from those of other features in that they are significantly redshifted not only at the line centers, but also at the wings. We also find that the spatio-temporal fluctuation of Doppler shift inferred from the Caii line is correlated with those of the $H{\alpha}$ line. The strongest correlation occurs in the internework region, and when the inner wings rather than the line centers are used to determine Doppler shift. In this region, the RMS value of Doppler shift fluctuation is the largest at the line center, and monotonically decreases with ${\Delta}{\lambda}$. We discuss the physical implications of our results on the formation of the $H{\alpha}$ line and Caii 854.2 nm line in the quiet region chromosphere.

  • PDF

Near-Infrared Spectroscopy versus Transcranial Doppler-Based Monitoring in Carotid Endarterectomy

  • Cho, Jun Woo;Jang, Jae Seok
    • Journal of Chest Surgery
    • /
    • 제50권6호
    • /
    • pp.448-452
    • /
    • 2017
  • Background: Proper monitoring of cerebral perfusion during carotid artery surgery is crucial for determining if a shunt is needed. We compared the safety and reliability of near-infrared spectroscopy (NIRS) w ith transcranial Doppler (TCD) for cerebral monitoring. Methods: This single-center, retrospective review was conducted on patients who underwent carotid endarterectomy (CEA) using selective shunt-based TCD or NIRS at Daegu Catholic University Medical Center from November 2009 to June 2016. Postoperative complications were the primary outcome, and the distribution of risk factors between the 2 groups was compared. Results: The medical records of 74 patients (45 TCD, 29 NIRS) were reviewed. The demographic characteristics were similar between the 2 groups. One TCD patient died within the 30-day postoperative period. Postoperative stroke (n=4, p=0.15) and neurologic complications (n=10, p=0.005) were only reported in the TCD group. Shunt usage was 44.4% and 10.3% in the TCD and NIRS groups, respectively (p=0.002). Conclusion: NIRS-based selective shunting during CEA seems to be safe and reliable for monitoring cerebral perfusion in terms of postoperative stroke and neurologic symptoms. It also reduces unnecessary shunt usage.

IN-CYLINDER FLOW ANALYSIS USING WAVELET ANALYSIS

  • Park, D.;Sullivan, P.E.;Wallace, J.S.
    • International Journal of Automotive Technology
    • /
    • 제7권3호
    • /
    • pp.289-294
    • /
    • 2006
  • Better fundamental understanding of the interactions between the in-cylinder flows and combustion process is an important requirement for further improvement in the fuel economy and emissions of internal combustion(IC) engines. Flow near a spark plug at the time of ignition plays an important role for early flame kernel development(EFKD). Velocity data measurements in this study were made with a two-component laser Doppler velocimetry(LDV) near a spark plug in a single cylinder optical spark ignition(SI) engine with a heart-shaped combustion chamber. LDV velocity data were collected on an individual cycle basis under wide-open motored conditions with an engine speed of 1,000rpm. This study examines and compares the flow fields as interpreted through ensemble, cyclic and discrete wavelet transformation(DWT) analysis. The energy distributions in the non-stationary engine flows are also investigated over crank angle phase and frequency through continuous wavelet transformation(CWT) for a position near a spark plug. Wavelet analysis is appropriate for analyzing the flow fields in engines because it gives information about the transient events in a time and frequency plane. The results of CWT analysis are provided and compared with the mean flows of DWT first decomposition level for all cycles at a position. Low frequency high energy found with CWT corresponds well with the peak locations of the mean velocity. The high frequency flows caused by the intake jet gradually decay as the piston approaches the bottom dead center(BDC).

수술중 경두개 초음파 집중감시 (Intraoperative Transcranial Doppler Monitoring)

  • 서대원
    • Annals of Clinical Neurophysiology
    • /
    • 제1권1호
    • /
    • pp.70-75
    • /
    • 1999
  • Trancranial Doppler(TCD) monitoring is a new application of ultrasonography which allows the nonivasive detection of blood flow velocity in the horizontal (M1) segment of the middle cerebral artery (MCA) and detects microembolic phenomena in the cerebral circulation. Recent studies emphasized the potential of using this technique in vascular surgery (carotid endarterectomy, cardiopulmonary bypass), interventional and intensive care setting. Although the disparity between CBF and blood flow velocity and number of microemboli could be used to prevent cerebral ischemic and embolism based on clinical studies. A reduction of more than 60% of MCA can reflex hemodynamic ischemic state and acoustic feedback of high intensity transient signals(HITS) from the TCD monitoring unit has a direct influence on surgical technique. TCD monitoring can immediately provide information about thromboembolism and hemodynamic changes, which may be a useful tool in the study and prevention of stroke.

  • PDF

반사파의 주파수 성분변화에 대응한 주파수 가변 초음파 트랜스듀서 (A Study of Frequency variable Ultrasonic Transducer for the Variation of Echo Characteristics in Reflecte Wave)

  • 김무준
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1997년도 영남지회 학술발표회 논문집 Acoustic Society of Korean Youngnam Chapter Symposium Proceedings
    • /
    • pp.40-43
    • /
    • 1997
  • It is known tat the echoes from the most objects differ from the incident pulses in amplitude and frequency .Especially, the frequency in echoes from moving target is shiftby the Doppler effect. it causes to reduce the receiving sensitivity of piezoelectric transducers that have definite band width. The electric impedance, whichis connected to the electrical terminals, notably changes the resonant frequency of a thickeness mode piezoelectric vibrator with high electromechanical doupling due to the electroelastic effect. Using this effect, we have developed a frequency controllable ultrasonic transducer which is mad eof multi-layered PZT disks to adjust to frequency shifted by Doppler effect. The characteristics of transducer can be obtained by using the equivalent circuit of transmission line model. It was confirmed experimentally that the center frequency and band width of the trasducer could be controlled by the conditions of the electrical terminals. These results coincided with theoretical results.

  • PDF