• Title/Summary/Keyword: Doppler Effect

Search Result 467, Processing Time 0.031 seconds

A Study on Ultrasound Pulsed Doppler Systems for Sending the Blood Flow (혈류 진단을 위한 초음파 펄스 도플러 시스템에 관한 연구)

  • Kim, Seong-Ryul;Kim, Jin-Ha;Park, Song-Bae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.5
    • /
    • pp.33-40
    • /
    • 1984
  • In the conventional pulsed doppler system, gated CW is used to excite a ultrasonic transducer so that a group of linear RF amplifiers are required to excite a ultrasonic array transducer in the scanning pulsed doppler system. A pulsed doppler system without linear high voltage RF amplifiers, which excites the transducer impulsively, is studied theoretically and experimentally. In this paper, an experimental 8-channel pulsed doppler system is implemented, which uses quadrature defection to detect the direction of motion and can compensate the attenuation effect. The designed pulsed doppler system shows the possibility of real time multichannel doppler flow meter.

  • PDF

A Study on the accuracy of speed measuring system by the Doppler effect -The error of speed single beam Doppler log over the ground by various trim- (Doppler 효과(效果)에 의한 속도계측장치(速力計測裝置)의 정도(精度)에 관(關)한 연구(硏究) -Single beam Doppler log의 트림 변화에 따른 대지속력(對地速力) 오차(誤差)-)

  • Kim, Koang-Hong
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.9 no.2
    • /
    • pp.179-187
    • /
    • 1997
  • Doppler log and current meter are based on the measurment of the doppler effect. Ship's speed over the ground measured by means of doppler log effect of underwater ultrasonic intends to get infulence by the difference of sound velocity, the ship's course, the sea bottom inclination, the trim and tranducer installation etc. This paper investigated on the error of speed over the ground by change of the trim comparing the real speed obtained by the mile post with the speed of single beam type doppler log on the trainning ship Kyeongyangho. The results are as follows ; 1. Indicating speed of doppler log is very much greatly influenced on variation of trim, but the real speed is less affected variation by trim. 2. The range of variation and error of speed over ground are smallest when ship's trim is 2.15m trim by the stern.

  • PDF

Assessment of a Phase Doppler Anemometry Technique in Dense Droplet Laden Jet

  • Koo, Ja-Ye;Kim, Jong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.7
    • /
    • pp.1083-1094
    • /
    • 2003
  • This study represents an assessment of the phase-Doppler technique to the measurements of dense droplet laden jet. High-pressure injection fuel sprays have been investigated to evaluate the use of the Phase-Doppler anemometry (PDA) technique. The critical issue is the stability of the phase-Doppler anemometry technique for dense droplet laden jet such as Diesel fuel spray in order to insure the results from the drop size and velocity measurements are repeatable, consistent, and physically realistic because the validation rate of experimental data is very low due to the thick optical density. The effect of shift frequency is minor, however, the photomultiplier tube (PMT) voltage setting is very sensitive to the data acquisition and noise in dense droplet laden jet. The optimum PMT voltage and shift frequency should be chosen so that the data such as volume flux and drop diameter do not change rapidly.

Noninvasive Estimation of Moxibustion Effect on Peripheral Blood Flow by Doppler Ultrasound in Stroke Patients with Hemiplegia: Case Series (뜸치료가 뇌졸중 편마비의 요골동맥 혈류변화에 대해 미치는 영향)

  • Yoon, Seung-Kyou;Lee, Sang-Hoon;Jung, Woo-Sang;Bae, Young-Min
    • The Journal of Korean Medicine
    • /
    • v.31 no.4
    • /
    • pp.178-186
    • /
    • 2010
  • Objectives: This study was to investigate the effect of moxibustion on peripheral blood flow by Doppler ultrasound in post-stroke hemiplegia patients. Methods: Moxibustion was applied on the points of LI4, TE3, TE5 and LI11 on the affected side, and blood flow of the radial artery was measured using the Minimax-Doppler-K device. Blood flow velocity and pulsation index were analyzed before, during, and after moxibustion. Results: The mean value of blood flow velocity in 13 patients showed a tendency of increase during moxibustion, but there was no significant difference in blood flow velocity before and after moxibustion, or pulsation index during and after moxibustion. In addition, among the five patients who showed marked increase tendency on the blood velocity graph, there was significant increase in blood velocity during, and after moxibustion compared with before moxibustion. Conclusions: This study suggests that moxibustion has an effect on peripheral blood flow in stroke patients with hemiplegia. Further validity tests with a larger scale sample are needed for the evidence of its practical use.

Doppler effect on Matched Field Processing in Ocean Acoustics

  • Song, Hee-Chun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.1E
    • /
    • pp.39-44
    • /
    • 1996
  • Matched field localization schemes often show a high sensitivity to acoustic variabilities due to mismatch between assumed and actual environments. In this paper, we focus on the effect of source motion or Doppler on matched field processing (MEP). to accomplish this, MFP is extended to treat a moving source problem with normal mode description of the sound field. the extension involves both the temporally nonstationary and spatially inhomogeneous nature of the sound field generated by a time-harmonic point source moving uniformly in a stratified oceanic waveguide. It is demonstrated that the impact of source motion can be significant to MEP although the velocity of a moving source is much smaller than the sound velocity of the oceanic waveguide. In addition, a criteria for minimizing the effect of Doppler on MFP is discussed.

  • PDF

Traffic Accident Analysis using Doppler Effect of the Horn (경적음의 도플러 효과를 이용한 교통사고분석)

  • Choi, Youngsoo;Kim, Jonghyuk;Yun, Yongmun;Park, Jongchan;Park, Hasun
    • Journal of Auto-vehicle Safety Association
    • /
    • v.12 no.4
    • /
    • pp.70-77
    • /
    • 2020
  • In this study, we estimate the vehicle speed by analyzing the acoustic data recorded in a single microphone of a surveillance camera. The frequency analysis of the acoustic data corrects the Doppler effect, which is a characteristic of the moving sound source, and reflects the geometric relationship according to the location of the sound source and the microphone on the two-dimensional plane. The acoustic data is selected from the horn sound that is mainly observed in an urgent situation among various sound sources that may occur in a traffic accident, and the characteristics of the monotone source are considered. We verified the reliability of the proposed method by time domain acoustic analysis and actual vehicle evaluation. This method is effective and can be used for traffic accident analysis in the blind spot of the camera using a single microphone built into the existing surveillance camera.

A study on the measurement of vibration using Laser Doppler Interferometer (레이저 도플러 간섭계를 이용한 진동 측정에 관한연구)

  • Kim, Chang-Hyun;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1738-1740
    • /
    • 1996
  • Laser Doppler Vibrometer using heterodyne method with a 632.8 nm He-Ne laser, has been developed for the measurement of small displacement and velocity. The measurement uses heterodyne method can be made insensitive to undesired vibration effect acting the system and can yield the sign of Doppler shift at the expense of increased complexity. A Bragg cell gives a frequency shift of 40MHz for heterodyne method. Frequency Modulated output is detected by spectrum analyzer.

  • PDF

Tricuspid Valve Repair in the Patients with Mitral Valve Replacement - Preoperative and Postoperative Evaluation by Doppler Echocardiography - (승모판 질환시 동반되는 삼첨판 폐쇄븟전증의 비침습적 치료판정 및 그 결과: 도플러 심에코에 의한 수술전후 판정)

  • Choe, Jong-Beom;Yun, Jae-Do;Jeong, Jin-Won
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.323-330
    • /
    • 1991
  • Residual significant tricuspid regurgitation after mitral valve operation may significantly increase postoperative morbidity and mortality. However, routine techniques to detect tricuspid regurgitation preoperatively and postoperatively are not accurate. Doppler echocardiography was performed preoperatively and postoperatively to assess its ability to evaluate and quantify the severity of tricuspid regurgitation. In 34 patients with tricuspid regurgitation secondary to mitral valvular disease the tricuspid regurgitations were semiquantified on a scale of 1 to 3+. The 34 patients were divided into two groups on the basis of severity of tricuspid regurgitation as assessed by preoperative Doppler echocardiography. Group I [8 patients] had mild[1+] regurgitation, and group II [26 patients] had moderate to severe[2 ~ 3%] tricuspid regurgitation. In all studied patients, preoperative Doppler echocardiographic studies for the degree of tricuspid regurgitation were correlated with clinical symptoms[including NYHA class] and hemodynamics[JVP and right ventricular systolic pressure], and used as the indicator to determine whether tricuspid annuloplasty should be performed or not. Patients with significant tricuspid regurgitation[group II ] had greater preoperative right ventricular systolic pressures and NYHA classes, although there was no correlation between them. The 8 patients with mild[1+] tricuspid regurgitation[group I ] didn`t undergo any procedure for the tricuspid regurgitation and their postoperative Doppler echocardiographic studies showed the less than mild[0 ~ 1+] tricuspid regurgitation, and the 26 patients with significant[>2+] tricuspid regurgitation, and the 26 patients with significant[>2+] tricuspid regurgitation[group II ] underwent tricuspid annuloplasty for the tricuspid regurgitation and the postoperative Doppler echocardiographic studies showed the findings similar to group I except 1 patient who underwent Carpentier`s ring annuloplasty and had severe right ventricular failure. Therefore, preoperative Doppler echocardiography can accurately assess the relative severity of tricuspid regurgitation. Importantly, postoperative Doppler echocardiography could conveniently determine the effect of tricuspid annuloplasty for the patients with significant tricuspid regurgitation. Doppler echocardiography may be an important diagnostic method both for evaluating the degree of residual tricuspid regurgitation after left heart operation as well as for determining which patients should undergo tricuspid valve repair.

  • PDF

Design and implementation of a X-band Doppler radar sensor using the homodyne detection (호모다인 검파방식을 이용한 X-밴드 도플러 레이더 센서의 설계 및 제작)

  • 장남영;최평석;은재정
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.2
    • /
    • pp.75-82
    • /
    • 2001
  • In this paper, a transmitter and a receiver using a Gunn diode and SBD was designed and fabricated in X-band. This system detects Doppler shift signal reflected by moving target through the homodyne detection, which is Doppler radar sensor for the measurement of the velocity of moving target. By the experimental results, the oscillating condition of the transmitter was satisfied at about the half wavelength between the supporting post of the Gunn diode in the waveguide and the waveguide short. And using the fabricated Doppler radar sensor, the velocity measurement deviation of moving target was 1.24%.

  • PDF

A Study on A New Two-Dimensional Pulsed Doppler System Using Second-Order Sampling Method. (2차 샘플링을 이용한 새로운 초음파 2차원 펄스 도플러 시스템에 관한 연구)

  • Park, Se-Hyeon;Im, Chun-Seong;Kim, Yeong-Gil
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.33-42
    • /
    • 1989
  • The doppler effect is used for measuring the velocity of the blood flow in artery. Because of the range information, the pulsed doppler system is most commonly used. In this paper, we propose a new two-dimensional(2-D) pulsed Doppler system. Which uses second-order sampling method and serial processing. The proposed system using second-order sampling method eliminates in-phase, quadrature-phase balancing problem at demodulator of quadrature detection method. In addition, the new pulsed 2-D doppler system eliminates balancing problem of channels of 2-D doppler system because of serial processing.

  • PDF