• Title/Summary/Keyword: Doppler Center Frequency

Search Result 58, Processing Time 0.026 seconds

A Study On The Doppler Radar Of Range Measurement On Electro-Optical Tracking System (광학추적장비의 거리측정 도플러 레이더에 관한 연구)

  • Park, Doo-Jin;Noh, Young-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.700-702
    • /
    • 2016
  • The Doppler Radar that mounted on Electro Optical Tracking System has been operated to measure range and velocity during the initial mission of space launch vehicle at Naro space center. In this paper, we mentioned configuration of MFCW(Multi frequency Continuous Wave) and FMCW(Frequency Modulation Continuous Wave) Doppler Radar on Electro Optical Tracking System and described method of range measurement.

  • PDF

The Relation of Time Resolution and Radial Velocity Accuracy of a CW Doppler Radar (CW 도플러 레이더의 시각 분해능과 시선 속도 정확도의 관계)

  • Ryu, Chung-Ho;Jang, Yong-Sik;Choi, Ik-Hwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.7
    • /
    • pp.815-821
    • /
    • 2012
  • A CW Doppler radar can measure radial velocity of an object. It detects a Doppler frequency shift that is proportioned to radial velocity of a moving object. To detect a Doppler frequency shift, FFT(Fast Fourier Transform) is conducted. In this process, the time domain received signal is transformed to a frequency domain. A number of FFT affects not only the time resolution but also signal to noise ratio of received signal. So finally it is related with a radial velocity accuracy. Therefore in this paper, it is described the relation of time resolution and the radial velocity accuracy.

Volumetric Blood Velocity Measurement on Multigate Pulsed Doppler System based on the Single Channel RF Sampling using the Optimized Sampling Factor (최적화된 샘플링 인수를 갖는 단일 채널 RF 샘플링 방식의 다중점 펄스 도플러 시스템을 사용한 혈류 속도분포 측정)

  • 임춘성;민경선
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.143-152
    • /
    • 1998
  • In this paper, we present the performances of a Doppler system using single channel RF(Radio Frequency) sampling. This technique consists of undersampling the ultrasonic blood backscattered RF signal on a single channel. Conventional undersampling method in Doppler imaging system have to use a minimum of two identical parallel demodulation channels to reconstruct the multigate analytic Doppler signal. However, this system suffers from hardware complexity and problem of unbalance(gain and phase) between the channels. In order to reduce these problems, we have realized a multigate pulsed Doppler system using undersampling on a single channel, It requires sampling frequency at $4f_o$(where $f_o$ is the center frequency of the transducer) and 12bits A/D converter. The proposed " single-Channel RF Sampling" method aims to decrease the required sampling frequency proportionally to $4f_o$/(2k+1). To show the influence of the factor k on the measurements, we have compared the velocity profiles obtained in vitro and in vivo for different intersequence delays time (k=0 to 10). We have used a 4MHz center frequency transducer and a Phantom Doppler system with a laminar stationary flow. The axial and volumetric velocity profiles in the vessel have been computed according to factor k and have been compared. The influence of the angle between the ultrasonic beam and the flow axis direction, and the fluid viscosity on the velocity profiles obtained for different values of k factor is presented. For experiment in vivo on the carotid, we have used a data acquisition system with a sampling frequency of 20MHz and a dynamic range of 12bits. We have compared the axial velocity profiles in systole and diastole phase obtained for single channel RF sampling factor.ng factor.

  • PDF

Interference Analysis Among Waveforms and Modulation Methods of Concurrently Operated Pulse Doppler Radars (단일 플랫폼에서 동시 운용되는 펄스 도플러 레이다의 파형 및 변조 방식간의 간섭 분석)

  • Kim, Eun Hee;Ryu, Seong Hyun;Kim, Han Saeng;Lee, Ki Won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.23-29
    • /
    • 2022
  • As the application field of radar is expanded and the bandwidth increases, the number of radar sensors operating at the same frequency is continuously increasing. In this paper, we propose a method of analyzing interference when two pulse doppler radars are operated at the same frequency with different waveform which are designed independently. In addition, we show that even for a previously designed LFM waveforms, the interference can be suppressed without affecting the performance by changing the sign of the frequency slope by increasing/decreasing, or by modulating the pulses by the different codes. The interference suppression by different slopes is more effective for similar waveform and the suppression by the codes increases as the number of pulses increases. We expect this result can be extended to the cases where multiple radars are operated at the same frequency.

The Effect of Sampling Frequency and Pulse Bandwidth on Estimating Mean Frequencies in an Ultrasonic Doppler System using the Second-Order Sampling (2차 샘플링을 이용한 초음파 도플러 시스템에서 샘플링 주파수 펄스 대역폭이 평균 주파수 측정에 미치는 영향)

  • Ahn, Young-Bok;Park, Song-Bai
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.3
    • /
    • pp.48-55
    • /
    • 1990
  • We analyze the effect of second-order sampling on estimating the mean frequency of the Doppler signal. In order to reduce the sampling frequency of analogue-to-digital converter, it is possible to obtain the Doppler signal by sampling the radio frequency echo signal with the low frequence of $4f_0$/5 or $4f_0$/9 instead of $4f_0$, where $f_0$ is the center frequency of the transmitted signal. The computer simulation and experiments show that if the narrowband signal is transmitted as is usual in the Doppler system, the error of the mean frequency estimates due to the low sampling frequency is negligible.

  • PDF

Radarsat-1 Doppler Information Extraction Technique Using Both Received Echo Data and Orbital and Attitude Information of Satellite (신호자료 및 궤도정보를 이용한 Radarsat-1 도플러 정보 추출기법 연구)

  • 고보연;나원상;이용웅
    • Korean Journal of Remote Sensing
    • /
    • v.19 no.6
    • /
    • pp.421-430
    • /
    • 2003
  • The extraction technique for Doppler information(Doppler centroid frequency(f$_{dc}$) and it's rate(f$_{r}$) is very important to make an image from the radar echo signal data. Clutterlock and auto-focusing techniques have been widely used to extract accurate Doppler information. But both techniques are not easy to implement in SAR processor and need quite lots of time to calculate accurate f$_{dc}$ and f$_{r}$ because they are generally based on echo signal data only. In this paper we suggest hybrid method for Doppler extraction using both of echo signal data and orbital and attitude information of satellite. In this method CDE(Correlation Doppler Estimation) technique is only used to estimate exact modular f$_{dc}$ using received echo signal data and rest of other algorithms are based on simple mathematical model of geometry between satellite and ground targets as well as the Doppler frequency ambiguity resolving problem. The experimental results using Radarsat-1 signal data shows that the proposed method can be effectively used for the extraction of Doppler information.

Speckle Noise Reduction for 3D Power Doppler Ventricle Image Restoration Using Wavelet Packet Transform

  • Jung, Eun-sug;Ryu, Conan K.R.;Hur, Chang Wu;Sun, Mingui
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.156-159
    • /
    • 2009
  • Speckle noise reduction for 3D power doppler ventricle coherent image for restoration and enhancement using wavelet packet transform with separated thresholding is presented. Wavelet Packet Transform divide into low frequency component image to high frequency component image to be multi-resolved. speckle noise is located on high frequency component in multiresolution image mainly. A ventricle image is transformed and inversed with separated threshold function from low to high resolved images for restoration to be utilize visualization for ventricle diagnosis. The experimental result shows that the proposed method has better performance in comparison with the conventional method.

  • PDF

A Study of Frequency variable Ultrasonic Transducer for the Variation of Echo Characteristics in Reflecte Wave (반사파의 주파수 성분변화에 대응한 주파수 가변 초음파 트랜스듀서)

  • 김무준
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.40-43
    • /
    • 1997
  • It is known tat the echoes from the most objects differ from the incident pulses in amplitude and frequency .Especially, the frequency in echoes from moving target is shiftby the Doppler effect. it causes to reduce the receiving sensitivity of piezoelectric transducers that have definite band width. The electric impedance, whichis connected to the electrical terminals, notably changes the resonant frequency of a thickeness mode piezoelectric vibrator with high electromechanical doupling due to the electroelastic effect. Using this effect, we have developed a frequency controllable ultrasonic transducer which is mad eof multi-layered PZT disks to adjust to frequency shifted by Doppler effect. The characteristics of transducer can be obtained by using the equivalent circuit of transmission line model. It was confirmed experimentally that the center frequency and band width of the trasducer could be controlled by the conditions of the electrical terminals. These results coincided with theoretical results.

  • PDF

Analysis of Slant Range Accuracy Using The Transponder of Doppler Radar (도플러 레이다의 트랜스폰더를 이용한 사거리 정확도 분석)

  • Park, Doo-jin;Noh, Young-hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.484-486
    • /
    • 2018
  • MF-CW(Multi-Frequency Continuous Wave)operated on Electro-Optical Tracking System to measure slant range of space launch vehicle and aircraft at Naro Space Center. In this paper, we compared and analyzed the difference exactly measured slant range using the laser lightwave range measuring equipment with measured on the transponder and described the accuracy of slant range.

  • PDF

IN-CYLINDER FLOW ANALYSIS USING WAVELET ANALYSIS

  • Park, D.;Sullivan, P.E.;Wallace, J.S.
    • International Journal of Automotive Technology
    • /
    • v.7 no.3
    • /
    • pp.289-294
    • /
    • 2006
  • Better fundamental understanding of the interactions between the in-cylinder flows and combustion process is an important requirement for further improvement in the fuel economy and emissions of internal combustion(IC) engines. Flow near a spark plug at the time of ignition plays an important role for early flame kernel development(EFKD). Velocity data measurements in this study were made with a two-component laser Doppler velocimetry(LDV) near a spark plug in a single cylinder optical spark ignition(SI) engine with a heart-shaped combustion chamber. LDV velocity data were collected on an individual cycle basis under wide-open motored conditions with an engine speed of 1,000rpm. This study examines and compares the flow fields as interpreted through ensemble, cyclic and discrete wavelet transformation(DWT) analysis. The energy distributions in the non-stationary engine flows are also investigated over crank angle phase and frequency through continuous wavelet transformation(CWT) for a position near a spark plug. Wavelet analysis is appropriate for analyzing the flow fields in engines because it gives information about the transient events in a time and frequency plane. The results of CWT analysis are provided and compared with the mean flows of DWT first decomposition level for all cycles at a position. Low frequency high energy found with CWT corresponds well with the peak locations of the mean velocity. The high frequency flows caused by the intake jet gradually decay as the piston approaches the bottom dead center(BDC).