A Study on Measurement of Heartrate and Respiration during Sleep using Doppler Radar: Preliminary Study (도플러 레이더를 이용한 수면 중의 심박 및 호흡 측정: 예비연구)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.264-270
    • /
    • 2017
  • A Doppler radar sensor was applied to detect respirations and heartbeats of persons who were lying on a bed. This study is preliminary study aiming at non-contact and non-intrusive respiration and heart rate monitoring during sleep in daily life. For the experiments, 10GHz Doppler radar with patch-type antenna was used and installed on the upper right and the distance between the body and the antenna was 1 m. The results show that each signal of respiration and heartbeat is observed in each frequency band however the frequency band and the waveform vary according to the subjects and the posture. The results show that the heartbeats can be detected with the peak detection in some frequency band. This study shows the feasibility of applying the Doppler radar to detection of heartbeat and respiration during sleep and further studies about heartbeat detection algorithm are required.

Assessment of a Phase Doppler Anemometry Technique in Dense Droplet Laden Jet

  • Koo, Ja-Ye;Kim, Jong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.7
    • /
    • pp.1083-1094
    • /
    • 2003
  • This study represents an assessment of the phase-Doppler technique to the measurements of dense droplet laden jet. High-pressure injection fuel sprays have been investigated to evaluate the use of the Phase-Doppler anemometry (PDA) technique. The critical issue is the stability of the phase-Doppler anemometry technique for dense droplet laden jet such as Diesel fuel spray in order to insure the results from the drop size and velocity measurements are repeatable, consistent, and physically realistic because the validation rate of experimental data is very low due to the thick optical density. The effect of shift frequency is minor, however, the photomultiplier tube (PMT) voltage setting is very sensitive to the data acquisition and noise in dense droplet laden jet. The optimum PMT voltage and shift frequency should be chosen so that the data such as volume flux and drop diameter do not change rapidly.

Quantitative Doppler echocardiography during Dobutamine stress test in canine mitral regurgitant model

  • Choi, Hojung;Won, Sungjun;Lee, Kichang;Choi, Mincheol;Yoon, Junghee
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.2
    • /
    • pp.317-322
    • /
    • 2004
  • This study was performed to evaluate echocardiographic parameters in dogs with experimental mitral regurgitation subjected to dobutamine stress testing. In 8 beagle dogs, a 4-prong grasping forceps was inserted into the left ventricle through the carotid artery with fluoroscopic guidance. The disruption of chordae or mitral valve leaflet was performed. Echocardiographic protocols included quantitative Doppler echocardiography and M-mode measurement for evaluating left ventricle function. After all measurement was obtained at rest, dobutamine was infused incrementally. In stress testing, all measurement also was performed at rest as the same method. In stress Doppler echocardiography, regurgitant fraction and aortic stroke volume was increased significantly (P<0.001). Effective regurgitant orifice and regurgitant volume was not changed. In M-mode examination, fractional shortening was increased significantly at stress test (P<0.001). From the results obtained in this study, it could be suggested that dobutamine stress echocardiography increase left ventricle performance in non-functional mitral regurgitation and quantitative Doppler echocardiography is non-invasive, accurate method in valvular regurgitation.

Laser doppler velocimetry using the optogalvanic effect of $Co_2$ laser (광전류 효과를 이용한 $Co_2$ 레이저 도플러 속도 측정기)

  • 최종운;김용평;김윤명
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.6
    • /
    • pp.482-485
    • /
    • 1997
  • A new laser Doppler velocimeter employing a $CO_2$laser has been developed by using its optogalvanic effect. A change in the electric impedance of a discharge, induced by mixing of a returned wave with an originally existing wave inside the cavity, was employed to detect the Doppler frequency shift. A Doppler frequency shift as much as 60 KHz was detected, and also a good linear relationship between the velocity and the Doppler frequency shift was obtained.

  • PDF

GPS L5 Acquisition Schemes for Fast Code Detection and Improved Doppler Accuracy

  • Joo, In-One;Sin, Cheon-Sig;Lee, Sang-Uk;Kim, Jae-Hoon
    • ETRI Journal
    • /
    • v.32 no.1
    • /
    • pp.142-144
    • /
    • 2010
  • In this letter, we propose GPS L5 acquisition schemes to detect a fast code phase and improve the accuracy of the Doppler frequency. The proposed approach is based on the code-phase changes which occur during the acquisition processing time originating in the Doppler frequency. The proposed schemes detect a fast code phase within about 1 chip near the estimated code phase and improve the accuracy of the Doppler frequency by up to about 4 times in comparison with the popular Septentrio receiver. The feasibility of the proposed schemes is demonstrated through simulation.

Implementation of a Microwave Doppler Sensor (도플러 효과를 이용한 마이크로파 센서의 구현)

  • Kim, Tae-Jin;Rhee, Young-Chul;Kim, Sun-Hyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.4 no.2
    • /
    • pp.75-81
    • /
    • 2009
  • In this paper, Microwave doppler radar sensor operated in 10.525GHz is designed by dielectric resonant oscillator. According to doppler effects, a characteristic of Microwave sensor with FMCW was analyzed. The qualities of objects velocity and distance between object and microwave sensor by sensor output frequency difference was measured. As a result of Microwave doppler radar sensor, the prototype sensor is available for indoor burglar alarms and other application through FMCW signal.

  • PDF

Photoacoustic Laser Doppler Velocimetrv Using the Self - mixing Effect of RF - excited CO2 Laser

  • Choi, Jong-Woon;You, Moon-Jong;Choi, Sung-Woong;Woo, Sam-Young
    • Journal of the Optical Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.188-191
    • /
    • 2004
  • A new laser Doppler velocimeter employing a $CO_2$ laser has been developed by using its photoacoustic effect. A change in the pressure of a discharge, induced by mixing of a returned wave with an originally existing wave inside the cavity, is employed to detect the Doppler frequency shift. We found that a Doppler frequency shift as small as 50 kHz was detected, and also a good linear relationship between the velocity and the Doppler frequency shift was obtained.

A Study On The Doppler Radar Of Range Measurement On Electro-Optical Tracking System (광학추적장비의 거리측정 도플러 레이더에 관한 연구)

  • Park, Doo-Jin;Noh, Young-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.700-702
    • /
    • 2016
  • The Doppler Radar that mounted on Electro Optical Tracking System has been operated to measure range and velocity during the initial mission of space launch vehicle at Naro space center. In this paper, we mentioned configuration of MFCW(Multi frequency Continuous Wave) and FMCW(Frequency Modulation Continuous Wave) Doppler Radar on Electro Optical Tracking System and described method of range measurement.

  • PDF

Assessment of Afterload by Doppler Aortic Flow Velocity Measurement (대동맥 혈류속도 측정에 의한 후부하 상태의 평가)

  • 손세정;한재진
    • Journal of Chest Surgery
    • /
    • v.34 no.2
    • /
    • pp.111-117
    • /
    • 2001
  • 배경: 심근 수축력과 더불어 전신저항은 개심술 후 적절한 심박출량을 유지하기 위한 매우 중요한 요인이다. 후부하의 변화를 비관혈적으로 평가할 수 있는지 알아 보고자 대동맥 혈류파형의 변화를 관찰하였다. 대상 및 방법: 개흉한 8마리의 잡견에서 연속파형 Doppler 심초음파를 이용하여 nitroprusside 단독 또는 epinephrine과의 병합투여 잔후로 상행 대동맥 혈류를 측정하였다. 결과: Nitroprusside의 투여로 동맥압과 전신저항은 약물의 투여량에 비례하여 감소함으로써(p<0.05 vs 기준치), 대동맥 혈류파형의 최고속도, 평균가속 및 분거리(속도시간적분$\times$심박동수)는 증가하였고, 가속시간은 짧아졌으며(p<0.05 vs 기준치), 가속시간/박출시간의 비는 변화가 없었다. Nitroprusside 투여로 인한 전신저항의 변화는 속도시간적분이나 Doppler 시간간격 지표보다는 최고속도(r=0.60, p=0.001)와 평균가속(r=0.52, p=0.003)과 상관관계가 있었다. Epinephrine과의 병합투여로 전신저항이 증가하지 않는 한 nitroprusside 단독투여에 비해서 최고속도, 평균가속 및 속도시간적분이 더 크게 증가했으나, 전신저항이 증가되면 이 Doppler 지표들은 감소하는 경향을 보였다. 결론: Doppler 심초음파를 이용하여 상행 대동맥 혈류파형의 최고속도와 평균가속을 연속적으로 측정함으로써 후부하의 변화를 비관혈적으로 평가할 수 있으리라 생각된다.

  • PDF

A study on the new doppler effect compensation scheme for OFDM system (OFDM system에서 새로운 Doppler effect 보정 기법에 대한 연구)

  • Lee, Sim-Seok;Jeong, Chang-Ho;Gang, Du-Lee;Lee, Byeong-Seop
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.2
    • /
    • pp.89-94
    • /
    • 2006
  • ODFM(Orthogonal Frequency Division Multiplexing) technique is suitable for high speed data transfer both in wired/wireless channels, and is actively studied recently. Among them, WiBro based on IEEE 802.16 uses ODFM as its core technology, and is currently trying to expand market through commercialization. Therefore, if it's used for high speed moving object(KTX, airplane..etc) in near future, there is a possibility of ICI(inter-carrier interference) to occur due to DFS(Doppler Frequency Shift), a critical weak point of ODFM System. This study suggests 3 compensation techniques for Doppler effects in ODFM system operating through satellite, and confirms improved performance through constellation and BER curve.

  • PDF