• Title/Summary/Keyword: Door width

Search Result 41, Processing Time 0.025 seconds

Risk Factors for Delayed Hinge Fracture after Plate-Augmented Cervical Open-Door Laminoplasty

  • Hur, Junseok W.;Park, Youn-Kwan;Kim, Bum-Joon;Moon, Hong-Joo;Kim, Joo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.368-373
    • /
    • 2016
  • Objective : Delayed hinge fracture (HF) that develops after cervical open door laminoplasty can be a source of postoperative complications such as axial pain. However, risk factors related to this complication remain unclear. We performed a retrospective clinical series to determine risk factors for delayed HF following plate-only open-door cervical laminoplasty. Methods : Patients who underwent plate-only open-door laminoplasty and had available postoperative computed tomography (CT) scans (80 patients with 270 laminae) were enrolled. Hinge status, hinge gutter location, open location, hinge width, number of screws used, operation level, and open angle were observed in the CT to determine radiographic outcome. Demographic data were collected as well. Radiographic and clinical parameters were analyzed using univariate and multivariate logistic regression analysis to determine the risk factors for HF. Results : Univariate logistic regression analysis results indicated poor initial hinge status, medially placed hinge gutter, double screw fixation on the elevated lamina, upper surgical level, and wide open angle as predictors for HF (p<0.05). Initial hinge status seemed to be the most powerful risk factor for HF (p=0.000) and thus was collinear with other variables. Therefore, multivariate logistic regression analysis was performed excluding initial hinge status, and the results indicated that medially placed hinge gutter, double screw fixation on the elevated lamina, and upper surgical level were risk factors for HF after adjustment for other confounding factors. Conclusion : To prevent HF and to draw a successful postoperative outcome after cervical laminoplasty, surgical and clinical precautions should be considered.

A Study on the Facility Accessibility of the Wheelchaired Persons for the Concept of Universal Design (휠체어 사용자의 Universal Access를 위한 시설 접근성 연구)

  • Jin, Sangeun;Yoo, Youngmi;Lee, Junhee;Park, Wongu
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.54-61
    • /
    • 2018
  • Objective: The current study aimed to investigate the accessibility and usability of the disabled person while using the everyday facility. Background: The national laws regulated accommodation of persons with disabilities, but our knowledge on the practical usefulness of the laws and acceptance by the users is still far from complete. Method: Compliance with laws was checked throughout the actual measurement of 87 engineering designs in the facilities of a national university, and the practical usability of the facilities was investigated by in-depth interviews with eight disabled persons. New design solutions were developed by the anthropometric methodology for better accommodation. The target-specific anthropometry database such as sitting knee height with wheelchair was employed. Results: First, the statistic showed that 28.7% of facility designs comply with the law, 29.9% of facility designs doesn't comply with the law, and 41.4% of facility designs doesn't have related law or regulation. Second, the law of table height(71cm in current) can accommodate only 49.3% of wheelchaired population. The following test for 95% accommodation revealed that the table with 80cm high is required. Third, the current law in the door width(90cm) can only accommodate 82.6% of disabled persons, so the new design solution was calculated and suggested that 100cm in the door width is necessary for 99% accommodation of disabled persons. Conclusion: Even with the laws and regulations for the disabilities it was clear that the accessibility and usability of the disabled persons in everyday facilities was still limited. An investigation for the new solutions about a wide range of facilities is necessary for better practical accessibility and usability of the handicapped persons. Application: The results of current study can be a basement of developing a new guideline or regulation of the facility design for the disabled persons.

A Statistical Study on Doorway Flow-time for Designing Doors of Ui LRT (우이-신설 경전철 출입문 설계를 위한 승하차시간 분석 연구)

  • Oh, Suk-Mun;Jang, Hyeon-Mog;Shin, Han-Chul
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.2
    • /
    • pp.144-150
    • /
    • 2013
  • This paper presents an analysis of door design for the Ui LRT based on experiments to predict doorway flow-time and their analyses results. A similar railway vehicle (from Gimhae LRT) and operational conditions are utilized to assess the doorway flow-time through repetitive experiments. Design of the experiments consists of four scenarios, and the experiments are repeated 39 times in total. We use the results of the experiments to verify the design of doors of Ui LRT (e.g. the required number of doors and their width). Various statistical analyses are carried out for the flow-time with respect to the number of boarding/alighting passengers. We make three category levels of boarding/alighting passengers, and analyze the mean and variance for each category, and then carry out One-Way ANOVA to analyze how the number of boarding/alighting and onboard passengers impact flow-time. The results of this paper can be used for making decisions about doors of the LRT vehicle.

A Study on Improvement According to Korea and China Evacuation Laws in Office Building (오피스 빌딩의 한국과 중국 피난관련 법 검토에 따른 개선 연구)

  • Lee, Byung-Hyun;Lee, Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.51-56
    • /
    • 2017
  • In the case of office buildings, domestic and Chinese evacuation laws were compared regarding the evacuation of horizontal and vertical buildings and evacuation to refuge safety areas. A simulation was conducted based on a refuge safety area in China. In the case of evacuating 1 floor, there was no significant difference in the flow of occupants to an ancillary room area in a domestic or Chinese building, but in China, the corridor width was narrower and the occupants have saw a long. In the case of evacuating 15 floors, the flow of occupants to an ancillary room area was different. In the case of China, it was possible for occupants to enter the ancillary room more quickly because the ancillary room area was wider than those found in domestic buildings, allowing quickly passage the ancillary room door. The results of this study found that if corridor width and ancillary room area were wider, evacuation times could be reduced.

A Study on Evaluation of Residential Environments and Residential Alterations for Physically Disabled Women (여성지체장애인 가정의 주택 개조 실태 및 거주자의 물리적 주거환경 평가에 관한 연구)

  • 최재순;권오정;이의정
    • Journal of the Korean Home Economics Association
    • /
    • v.39 no.11
    • /
    • pp.1-14
    • /
    • 2001
  • In order to develop a manual of residential alterations for the physically disabled, this case study was accomplished to analyze and evaluate residential environments and residential alterations for physically disabled women. Twenty-nine physically disabled women in Seoul and Kyunggi areas were the subjects of this study. With the evaluation checklist on physical environments of their housing, data on general characteristics of wall, floor, and all features and equipments and spaces of bedroom, kitchen, bathroom, living mom, entrance and balcony were gathered. Also, data on residential alterations were gathered through personal interviews. The data were collected from July 18th to July 25th in 2000. Frequency, percentage, and mean were used to analyze the data. In kitchen, small space, hee space under the sink and heights of the lower cabinets were not properly provided. In bathroom, door width, direction of opening door, adjustable height of shower, level difference, clear space for wheelchair user, and storage place were not appropriate to the disabled. Kitchen and bathroom showed high frequencies of alteration. But most of the subjects were not satisfied with the alterations of their housing. They also wanted to alter these two spaces in the future. In order to after their housing effectively appropriate information of the residential alterations was needed. If a guide or manual book for residential alterations was provided, the physically disabled people will more easily after their housing for safe and independent life.

  • PDF

A Study on Improvement of Barrier Free Door Standard (Barrier Free 출입문 규격기준 개선에 관한 연구)

  • Kim, In-Bae;Kim, Won-pil
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.4
    • /
    • pp.7-15
    • /
    • 2017
  • Purpose: The Korean government has implemented a Barrier Free Certification System since 2008 to create a secure and convenient environment for the socially disadvantaged. The drastic increase in the number of BF-certification facilities is expected due to the revision of the system and increasing the number of certification institutions. An analysis of individual evaluation items needs to be made for the BF-Certification with public confidence. Method: Korean standard, International Standard(ISO/FDIS 21542, 2011), German Standard(DIN 18040-1, 2010), Austrian Standard(${\ddot{O}}NORM$ B 1600, 2017) and Swiss Standard(Norm SIA 500 / SN 521 500, 2009) were investigated and analyzed. A comprehensive improvement plan is proposed by comparing details of the aforementioned standards and the evaluation items of BF-Certification. Results: Many problems arise in applying existing Barrier-free standards due to changes in population structure, environmental change and the use of powered wheelchairs. International standards are being improved to solve these problems. The korean standards also require improving of the Barrier Free Law and Certification System, which reflect these trends. In korean cases, standards such as the size of the doors (width and height), the Unobstructed Manoeuvring Space and Clear Space at the Latch side of the Door are required to improve standards in accordance with international standards. In addition, the expression of laws and evaluation items of BF-Certification should be clearly defined. And the application of visual contrast standards for the enhancement of perceptions presented in international standards should be considered. Implication: Barrier Free related legal standards and evaluation items of BF-Certification that are used in Korea are required to be revised in consideration of social and environmental changes. Comprehensive improvements should be made through detailed review.

Installation Standards of Urban Deep Road Tunnel Fire Safety Facilities (도심부 대심도 터널의 방재시설 설치 기준에 관한 연구(부산 승학터널 사례를 중심으로))

  • Lee, Soobeom;Kim, JeongHyun;Kim, Jungsik;Kim, Dohoon;Lim, Joonbum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.727-736
    • /
    • 2021
  • Road tunnel lengths are increasing. Some 1,300 tunnels with 1,102 km in length had been increased till 2019 from 2010. There are 64 tunnels over 3,000 m in length, with their total length adding up to 276.7 km. Safety facilities in the event of a tunnel fire are critical so as to prevent large-scale casualties. Standards for installing disaster prevention facilities are being proposed based on the guidelines of the Ministry of Land, Infrastructure and Transport, but they may be limited to deep underground tunnels. This study was undertaken to provide guidelines for the spacing of evacuation connection passages and the widths of evacuation connection doors. Evacuation with various spacing and widths was simulated in regards to evacuation time, which is the measure of safety, using the evacuation analysis simulation software EXODUS Ver.6.3 and the fire/smoke analysis software SMARTFIRE Ver.4.1. Evacuation connection gates with widths of 0.9 m and 1.2 m, and spacings of 150 m to 250 m, were set to every 20 m. In addition, longitudinal slopes of 6 % and 0 % were considered. It was determined to be safe when the evacuation completion time was shorter than the delay diffusion time. According to the simulation results, all occupants could complete evacuation before smoke spread regardless of the width of the evacuation connection door when the longitudinal slope was 6 % and the interval of evacuation connection passage was 150 m. When the evacuation connection passage spacing was 200 m and the evacuation connection gate width was 1.2 m, all occupants could evacuate when the longitudinal slope was 0 %. Due to difference in evacuation speed according to the longitudinal slope, the evacuation time with a 6 % slope was 114 seconds shorter (with the 190 m connection passage) than with a 0 % slope. A shorter spacing of evacuation connection passages may reduce the evacuation time, but this is difficult to implement in practice because of economic and structural limitations. If the width of the evacuation junction is 1.2 m, occupants could evacuate faster than with a 0.9 m width. When the width of a connection door is 1.2 m with appropriate connection passage spacing, it might provide a means to increase economic efficiency and resolve structural limitations while securing evacuation safety.

Characteristics of Interior Space in Huizhou Traditional Houses (중국 휘주지역 전통주택의 공간구성 특성)

  • Park, Sunhee
    • Journal of the Korean housing association
    • /
    • v.26 no.6
    • /
    • pp.147-155
    • /
    • 2015
  • The purpose of this study is to understand the characteristic elements of interior space which effects the basic floor plan of traditional houses, in Huizhou, CHINA. The field study for the content analysis of a interior space of traditional houses were conducted from August 16 to 21, 2015, in Xidicun & Hongcun village. The major characteristics of 'tang' interior were as follows; Firstly, all of traditional houses in a skylight that front of 'tang'. Several types of floor plan were fixed by a combination of the space layout and numbers between 'tang' and skylights. Secondly, 'Tang' is from 3,250 to 6,000 mm in width, from 3,800 to 7,800 mm in depth. All skylights are more length than 'tang' in width. So all of spacious 'tang' were very bright without any lighting fixtutes. Thirdly, the patterns of woodcuts were the major settings of interior decorations. All of a window and door, capital has a detail woodcuts that are flowers, animals, plants, peoples, vases, and geometric patterns. In the last analysis, the traditional housing designs in Huizhoui old villages were planned for family that everlasting life, made a functional and rational decision.

A Study on the Wall Components of Sarang-taechong in the Upper Class houses of Chosun Dynasty (조선시대 상류주택 사랑대청의 실내입면구성요소에 관한 연구)

  • 오혜경;홍이경
    • Journal of Families and Better Life
    • /
    • v.18 no.2
    • /
    • pp.191-202
    • /
    • 2000
  • The purpose of this study was to clarify the wall components of Sarang-taechong in the upper class houses of Chosun dynasty. Physical trace method was used for this study. The samples were taken from the Sarang-taechong of 6 traditional Korean houses; Yunkyungdang, the ancient Chusa estate, Sunkyojang, Chunghyodang, Yangjindant, Unjorn. The makor findings were summarized as follows; 1) The common components of each wall were pillars, sanginbangs(upper horizontal beams), hainbangs (lower horizontal beams), door and windows. Changbangs(wood eave pieces that suported decoration blocks), changyos(a pice of wood fitted between the tops of pillars and upper tori cross beams), and morums(the top wainscot board laid horizontally between the bottom beam and the bottom portion of a window frame) were additional. 2) The composition of every south wall was symmetrical and the other threes were mixed symmetrical and asymmetrical. 3) The image of wall was classified-fine, strong, and modera e, according to the symmetry or asymmetry of wall composition, the width of each components, the kind of window.

  • PDF

Study on the Basic Properties of Platanus occidentalis L. for Its End-use Development (양버즘나무의 용도개발(用途開發)을 위(爲)한 기초재질시험(基礎材質試驗))

  • Lim, Kie-Pyo;So, Won-Tek
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.8-15
    • /
    • 1990
  • This study was carried out to investigate the wood qualities for the end-use development of sycamore (Platanus occidentalis L.) grown in Korea. The results obtained were as follows: 1. The average length of wood fibers was l.56mm and the average width of annual rings was 9.5mm. It had very fast growth rate. 2. The specific gravity in air-dry was 0.66. The shrinkage and water absorption were relatively large. The shear and impact strengthes were very strong, while the compressive, tensile, and bending strengthes were weak in comparison to it's specific gravity. 3. The contents of ash, holocellulose, lignin were relatively high 0.74%, 83.08%, 28.79%, but that of pentosan was low 18.53%. 4. The expected uses of sycamore wood are plywood. fancy veneer, small furniture, musical instrument, door and window frame, tool handels, boxes, etc.

  • PDF