• 제목/요약/키워드: Door width

검색결과 41건 처리시간 0.022초

하부틈새 크기에 따른 도어의 음향감쇠계수 분석 (Sound Reduction Index of Interior Door by Aperture Sizes at Door's Bottom)

  • 김명준
    • 한국소음진동공학회논문집
    • /
    • 제20권9호
    • /
    • pp.834-840
    • /
    • 2010
  • The Sound reduction indices(SRIs) of interior door with 13 different size apertures are measured in acoustic chamber. Also, as a theoretical approach, the SRIs are estimated using Gomperts' theory. In this study, the aperture of interior door is focused on the lower part of door leaf which is well known as a main cause to deteriorate the sound insulation performance of door. The results show that the SRI of door strongly depends on the aperture width and the dip in the measured sound reduction index curve by the resonance effect within aperture is observed at high-frequency. On the whole, the values calculated by theory are in good agreement with the measured values including the position of resonance dip. The average difference between the measured and the calculated values is 0.9 dB for 13 doors with different size aperture in terms of the weighted SRI.

형태 제약과 출입구를 고려한 설비 배치 및 복도 구조 디자인 (Factory Layout and Aisle Structure Design Considering Dimension Constraints and Door Locations)

  • Chae-Bogk Kim
    • 산업경영시스템학회지
    • /
    • 제26권3호
    • /
    • pp.58-66
    • /
    • 2003
  • The cut tree approach of Montreuil and Ratliff [16] and eigenvector approach [10] are used to automatically draw a feasible facility layout with aisle structure. The department arrangement can minimize an aisle distance criterion considering door locations and dimension constraints. The aisle distance is measured by the door to door distance between departments. An eigenvector and cut tree approaches [1] are implemented based on the branch and bound technique in Kim et al. [2] in order to obtain feasible layouts. Then, the algorithm to fix the door location of each department is developed. After the door locations are determined, the factory layout is evaluated in terms of aisle distance. The aisle structure is obtained by expanding the original layout. The solution is kept until we will find better factory layout. The proposed approach based on the branch and bound technique, in theory, will provide the optimal solution. If the runs are time and/or node limited, the proposed method is a strong heuristic. The technique is made further practical by the fact that the solution is constrained such that the rectangular shape dimensions length(l) and width(w) are fixed and a perfect fit is generated if a fit is possible.

교육공간에 대한 유니버설 디자인 관점에서의 평가 사례연구(2) - 중·고등학교 사례를 중심으로 - (A Case Study on Evaluation of Educational Space in point of Universal Design - Focused on a Middle and High School -)

  • 오찬옥;김선영
    • 한국실내디자인학회논문집
    • /
    • 제21권5호
    • /
    • pp.23-33
    • /
    • 2012
  • This study evaluated two educational spaces, one middle school and one high school in point of universal design. The survey method with an observation and measuring method was used. The subject were 238 students of a middle and a high school. They evaluated their schools according to 53 universal design related items which consisted of 5 principles. Findings were as follows ; 1) The width of passage between desk and desk was very narrow and there is the threshold at the door of classroom. The students evaluated them negatively, too. Also, they indicated that the size of individual locker was small and the corner of furniture was sharp. 2) The width of door and passage was narrow and the floor was not flat in restroom. The design quality such as color and finishes was not good. Also, the students evaluated all these items negatively. 3) The dining space was too big. That is, so many students takes meals in one big space. The dining tables were arranged in a long rows and the width between them was also so narrow to pass through. 4) The student of high school evaluated their educational environments more negatively than ones of middle high school. This means that the high school students were more dissatisfied with their school environment. The educational environment should be designed on the base of their students' needs.

  • PDF

불연속면이 존재하는 지반에서 터널굴착에 의한 하중전이 (Load-transfer mechanism in the ground with discontinuity planes during tunnel excavation)

  • 이상덕;변광욱;유건선
    • 한국터널지하공간학회 논문집
    • /
    • 제4권1호
    • /
    • pp.71-78
    • /
    • 2002
  • 본 연구에서는 지반내에 뚜렷한 불연속면의 존재로 인한 하중의 비대칭 전이특성과 이완영역의 형상을 실내실험에 기초하여 고찰하였다. 가동판(trap-door)과 바닥판(reaction plates)을 토조바닥에 설치하고, 건조한 모래지반에 연직의 불연속면을 설치하여 불연속성 지반을 형성하였다. 다양한 토피고와 불연속면의 위치를 실험변수로 적용하였다. 연구결과, 토층비(=토피고/가동판의 폭)가 1.5 이상이 되면, 토압비(전이응력/초기지반응력)는 일정한 값에 수렴되는 것으로 나타났다. 불연속면이 터널 폭 내에 위치하면 불연속면의 영향이 상대적으로 커져서 비대칭성 하중집중이 두드러지게 나타났으며, 터널폭 외부에 존재하면 비대칭성 하중집중이 상당히 감소하는 것으로 타나났다.

  • PDF

도시철도 열차 승하차시간 분석에 관한 연구 (An Analysis of Boarding and Alighting Times for Urban Railway Vehicles)

  • 김정태;김무선;홍재성;조용현;김태식
    • 한국철도학회논문집
    • /
    • 제17권3호
    • /
    • pp.210-215
    • /
    • 2014
  • 도시철도의 표정속도를 증대시키기 위해 여러 가지 방안이 연구되고 있는데 출입문 폭 확장을 통한 정차시간 단축은 이러한 방안 중 하나이다. 그러나, 출입문 폭을 확장하였을 때 단축되는 승객 승하차시간을 예상하기 위해 적합한 국내 모델과 수식은 아직 수립되지 않은 형편이다. 승하차 동작은 사람의 행동 방식에 영향을 많이 받고 이는 국가 별로 상이하다는 점을 고려한다면 승하차시간에 대한 외국 모델을 따른 다는 것은 적합하지 않다. 본 연구에서는 국내에서 측정 및 실험한 데이터를 바탕으로 국내 환경에 적합한 모델을 세우고 관련 수식과 변수를 유도함으로써 출입문 폭 확장 시 승하차시간 단축효과를 예상할 수 있도록 한다.

의료시설의 한국형 인명안전기준개발을 위한 피난용량 산정에 관한 연구 (A Study on the Calculation of Evacuation Capacity for the Development of Korean Life Safety Standards for Medical facilities)

  • 최윤주;김윤성;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.92-93
    • /
    • 2021
  • In the case of medical facilities, the evacuation time is delayed due to the decrease in the number of people in the hallway and exits due to the increase in the width of evacuation by using mobile beds, wheelchairs, crutches, etc. Accordingly, it is considered to secure evacuation capacity to reduce evacuation time according to corridor width and exit width. Accordingly, we would like to compare the standards related to the evacuation capacity of medical facilities in Korea and NFPA, derive differences, and use evacuation simulations to compare evacuation times according to changes in corridor width and exit width. In Korea, it is calculated based on the floor area by use, but in the case of NFPA 101, the number of evacuation routes, stair width, corridor exit width, and two-way door width was stipulated depending on the number of people. Using evacuation simulation, efficient evacuation capacity is calculated according to the reduction of evacuation time by changing the width of the hallway, changing the width of the exit, the width of the corridor, and the width of the exit. The evacuation simulation is intended to be used to secure evacuation safety of domestic medical facilities by calculating the effective evacuation time reduction by changing the width of the hallway and exit.

  • PDF

The Evaluation of Adaptability of Three Ever-green Perennial Herbaceous South Korea Native Plants under In-door Light Intensities

  • Sang Yeob Lee;Kyungtae Park;Bo Kook Jang;Cheol Hee Lee;Ju Sung Cho
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2020년도 춘계학술대회
    • /
    • pp.67-67
    • /
    • 2020
  • Though there is an on-going need for the diversity of ornamental plants for in-door environment, their growth and stress adaptability in comparatively low light intensity condition require further studies for implementation. Here investigates the growth and chlorophyll fluorescence parameters of Farfugium japonicum (L.) Kitam, Liriope muscari (Decne.) L.H.Bailey and Acorus gramineus Aiton under several light intensities which were based on common in-door environment. The growth measurement of the plants included the quantity, length, width and SPAD value of the leaves. Calculated values of Fm/Fo, Fv/Fm, Pi_Abs, ETo/RC and DIo/RC were used as the parameters of the chlorophyll fluorescence under 10, 50, 100 and 200 PPFD (μmol·m-2·s-1) light intensities. In-door plants group was put in a closed room allowing no other light sources for 10 weeks and the control group was put in glass-greenhouse for the same period. The overall in-door growth of L. muscari was not significantly different in all light intensities compared to the control group and even showed the higher SPAD values. Also, an increasing tendency of Pi_Abs value under 10 to 100 PPFD was observed implying that L.muscari could adapt well to in-door environment. Measurement of A. gramineus growth mostly showed the highest values in the control group especially in the number of the leaves. Nevertheless, chlorophyll fluorescence parameters showed no significant value difference between in-door and the control groups and thus, A. gramineus might have possibility of successful adaptation to in-door environment. F. japonicum showed deficient growth in plant height and leaf length compared to the control but, it seemed to be able to sustain ornamental value under in-door light intensities. Furthermore, Pi_Abs and DIo/RC values were increased under in-door light conditions suggesting potential adaptability of F. japonicum.

  • PDF

출입문 측면 활동공간 설치기준 개선에 관한 연구 (A Study on Improvement of the Standards for the Manoeuvring space at Doors)

  • 신동홍;박광재
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권4호
    • /
    • pp.71-79
    • /
    • 2019
  • Purpose: The manoeuvring space at doors must be secured for users of walking aids, wheelchair users, stroller users, luggage carriers, etc., so clear criteria must be established. The korean standards for the manoeuvring space at doors need to be improved to present clear criteria depending on the type of entrance and the direction of opening and closing. Method: Korean standard, International Standard(ISO 21542, 2011), German Standard(DIN 18040-1, 2010), Austrian Standard(OENORM B 1600, 2017) and Swiss Standard(Norm SIA 500, 2009) were investigated and analyzed. A comprehensive improvement of the criteria for the manoeuvring space at doors is proposed. Results: The manoeuvring space at doors, which is essential for the disabled to use the door, shall be installed with a comprehensive consideration of the width of doors, the Circulation space, the direction of access, and the method of opening and closing of the door. Korean standards, such as the width of doors, the Circulation space, and the manoeuvring space at doors, are different from international and international standards, which require improvement of standards. The criteria for the manoeuvring space at doors shall be clearly improved so as not to be misinterpreted during the installation of doors and the BF-certification. Implication: The criteria for the installation of doors shall be presented as a comprehensive alternative through continued study of details. In addition, improvements in standards that reflect changes in international standards should be made.

유니버설 디자인 관점에서 성당 비전례공간 평가 - 부산교구 6개 사례를 중심으로 - (Evaluation on Non-liturgical Space of Catholic Churches from the Perspective of Universal Design - Focused on 6 Cases in Busan Parish -)

  • 조연주;남경화;신경주
    • 한국실내디자인학회논문집
    • /
    • 제24권3호
    • /
    • pp.38-47
    • /
    • 2015
  • This study evaluated non-liturgical space of catholic churches based on the four principles of universal design; accessible design, supportive design, safety-oriented design, and adaptable design. To design those spaces in terms of supportive design principle, diaper exchanging station needs to be placed in the restroom. Findings of this study are as follows: In terms of accessible design, valid width of entrance door to each room(more than 800mm), installation of elevator, height of riser in the stair, and width of step board were appropriate, but there were many spaces where door sils were not removed. In terms of supportive design, notice board at teacher's room and installation of storage closet, and width of passage to office(more than 1,200mm) were also appropriate, but storage closet at a meeting and prayer room, and space for storing flowers appeared inappropriate. To design those spaces in terms of supportive design principle, diaper exchanging station needs to be placed in the restroom. In terms of safety-oriented design, installation of round-edged furniture, use of non-slip flooring material, installation of safety emergency bell at a restroom, and installation of wall handle were required. In terms of adaptable design, space for wheelchair users at each room, installation of the furniture that can adjust the height, installation of desk with different height at an office, installation of toilet and basin considering children were considered to be necessary.

낙동강변 하항취락의 주거공간구성과 변용 -밀양시 삼랑진읍 상부(上部)마을을 중심으로- (Transformation and Housing Spatial Form of the Port Settlement of Rivershore in Nakdong River -Focused on Sangbu Village of Samrangjin, Milyang city-)

  • 박중신
    • 한국농촌건축학회논문집
    • /
    • 제9권3호
    • /
    • pp.121-128
    • /
    • 2007
  • This paper aims to clarify the transformation and housing spatial form of the Port Settlement of Rivershore in Sangbu-village, Samrangjin. The form of site are many fixed forms, has the narrow width of a site and the length is long. Although built as a shop house those days, there is much what changed to the residence now. If the space composition of a residence is seen, it is one building and what goes in and out through the door is common. When a focus is applied and analyzed to the transformation of a residence, position change of formation of the door and an entrance is noticeable.

  • PDF