• 제목/요약/키워드: Door

검색결과 1,921건 처리시간 0.029초

ADAMS를 이용한 Door Damper 동적거동 해석 (Door Damper Simulation using ADAMS)

  • 황재업;권용철;배재성;황재혁;홍예선
    • 항공우주시스템공학회지
    • /
    • 제6권2호
    • /
    • pp.13-17
    • /
    • 2012
  • In this study the flow rate-to-pressure difference characteristics of short-tube type damping orifices for a aircraft door damper were investigated by CFD analyses. For the verification of the CFD analysis results the actual performance of a door damper was measured and compared with them. and The dynamic response of door damper is Simulated using ADAMS. it's performance is evaluated comparing to the experiment result of door damper.

전동차 소음저감을 위한 슬라이딩플러그 출입문 개발 (Development of a Sliding-Plug Entrance Door System for Urban Electric Transit Unit to Reduce Inside Noise Level)

  • 서승일;임영호;신동국
    • 한국철도학회논문집
    • /
    • 제5권2호
    • /
    • pp.112-117
    • /
    • 2002
  • Reduction of noise level in the cabin of urban transit unit is an important issue to enhance the comfortability of passengers. It is made clear that a cause of increased noise level in cabin is the imperfect airtightness of entrance doors. In this study, the sliding-plug door system is developed to reduce the noise level of cabins by securing the airtightness of entrance door. The sliding-plug door system is composed of air-driven engine, swing arms, guide rails, guide rollers and locking devices. It is economical owing to using the previous door engine system. It is also adequate for the platform system of our subway station. It was tested to prove the reliability of system and was applied to standard urban transit unit. The effectiveness of noise reduction in cabin resulting form the sliding-plug door system was confirmed by test results.

동해석을 이용한 전자레인지 도어 프레임의 비틀림 변형 저감 구조설계 (Structural Design of the Door Frame of a Microwave Oven to Decrease Its Twisting Deformation Using Dynamic Analysis)

  • 이부윤;구진영;김원진
    • 한국정밀공학회지
    • /
    • 제23권8호
    • /
    • pp.145-153
    • /
    • 2006
  • To minimize the possible leakage of microwave when one opens the door of a microwave oven during its operation, a structural design of the reinforcing brackets for the door frame is presented. Twisting deformation of the door frame resulting from a dynamic pulling force is analyzed by harmonic and transient response analyses. Several types of the reinforcing brackets weldable to the right flange of the door frame is taken into consideration, and their effects to the twisting deformation of the door frame are compared and evaluated. As a conclusion, a thick step-shaped bracket, which is welded to whole length of the right flange, is favorable.

방화문의 현장품질관리 개선방안에 관한 연구 (A Study on Improvement of the Quality Management for Fire Doors)

  • 최동호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.93-94
    • /
    • 2019
  • When the fire door is recently installed in the field, there are frequent cases where the fire door is manufactured with fire door having low quality or different structure compared to the performance that the fire door producer has confirmed in the performance test or the construction specification. In order to improve the on-site quality management of the fire door, we comprehensively classify the quality management items of the fire door according to the management subject and the step by stage and set the field quality management procedure, the field quality management inspection item, regulations and standardized checklists were presented.

  • PDF

벡터제어를 적용한 엘리베이터 도어용 유도전동기 구동 시스템 개발 (Development of Induction Motor Drive system for the Elevator door using Vector control)

  • 김상훈;박내춘
    • 산업기술연구
    • /
    • 제29권A호
    • /
    • pp.155-159
    • /
    • 2009
  • Recently, a Elevator system is specially important in human life. Also a elevator door is important to a elevator system. In this paper, induction motor drive system using vector control was developed with high performance for elevator door system. For this, velocity pattern generation method was proposed. The proposed system is verified by experimental result with 400[w] induction motor drive system for the elevator door.

  • PDF

전기식 도어시스템의 고장건수 및 지연시간을 활용한 열차운행장애 분석 (Analysis of Train Operation Obstacle Using Number of Failures and Delay Time of Electric Door System)

  • 이본형;김두현;김성철
    • 한국안전학회지
    • /
    • 제35권1호
    • /
    • pp.12-17
    • /
    • 2020
  • This paper analyzes functions of component parts of D-Urban Railway's door system along with operation obstacle risks on frequency(the number of occurrences/year) and severity(delay time/the number of occurrences). Based on this, the paper presents improvements and current system's problems after obstacle risks of EMU and door system are appled. The obstacle of door system causes corrosion of main parts such as DCU due to heat problem of operation environment, problems of maintenance methods and deterioration. DCUs on PCBs with more than 50% pattern corrosion cause problems. Even though the number of door system's obstacle occurrences for the last 5 years is 42, along with 104 minutes of operation obstacle, EMU operation obstacle risk is low(Level 1), which indicates there is limit in matrix of railway risks presented by the standard of railway safety management system. Therefore, it is necessary to have railway risk matrix suitable for the field. Finally, the paper deducts the obstacle risks through frequency and severity. Since 2017 when the risks of EMU and door system's obstacle, that of EMU has been 24(47% reduced) and that of door system has been average 9.5 per year(23% reduced).

빌트인 양문형 냉장고의 캐비닛 구조해석 및 도어 상하단차와 앞뒤단차의 평가 (Structural Analysis of Cabinet in Built-in Side-by-Side Refrigerator and Evaluation of Door Height Difference and Door Flatness Difference)

  • 이부윤
    • 한국기계가공학회지
    • /
    • 제17권2호
    • /
    • pp.30-36
    • /
    • 2018
  • Since the freezer compartment and the refrigerating compartment are located side by side in a side-by-side refrigerator, the problems of the door height difference (DHD) and door flatness difference (DFD) have been constantly raised. Deformation of the cabinet of a built-in side-by-side refrigerator under food and thermal loads was analyzed by the finite element software ANSYS. The DHD and DFD, occurring due to the deformation of the cabinet, evaluated. From the results of the analysis of the cabinet, the 3D CAD software CATIA was used to geometrically translate and rotate the freezing and refrigerating compartment doors, in consideration of the displacement of the hinge fastening point. Then, the coordinates of two points on the upper corner of the doors were determined, and the DHD and DFD were obtained. It found that the thermal load, occurring under normal operation conditions, decreases the door height difference, but increases the door flatness difference. Values of the analyzed DHD and DFD appear smaller than the acceptance criteria used by the refrigerator manufacturer.

자동차 도어의 충돌 시 파손에 대한 안전성 연구 (Study of Safety on Damage of Automotive Door at Impact)

  • 조재웅;민병상;김기선
    • 한국산학기술학회논문지
    • /
    • 제11권12호
    • /
    • pp.4677-4684
    • /
    • 2010
  • 본 연구에서는 자동차 도어에 대한 충격을 흡수하기 위한 차체의 해석을 함으로서 승차자의 안전을 조사할 수 있었다. 차체의 충돌이나 운전자의 부주의로 인한 주차 사고 때문에 자동차 도어의 손상이 일어난다. 이러한 도어는 CATIA 프로그램으로 모델링하였고, ANSYS 프로그램을 통하여 충돌에 의한 도어 모델의 파손과정을 해석하고 조사하였다. 등가응력과 변형율의 등고선들을 구하였고 충돌 하에서 도어가 어떻게 파손이 일어나는지를 확인하였다. 본 연구 결과로서 충돌안전을 고려한 도어 설계에 기여 할 것이라 사료된다.

철도차량시스템과 PSD간 인터페이스 방안 및 적용 현황 (The Interface Scheme and Application Between Rolling Stock System and PSD)

  • 이종성;민영기;김경식;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1510-1512
    • /
    • 2004
  • Platform Screen Door System is a facility on platform to separate platform from track, having automatic sliding door structures interlocked to opening and closing of train door with integrated control unit. When a train comes to a stop at a designed position at a station, onboard ATC/ATO system transmits train berth signal to wayside signaling system. In case of automatic/driverless operation, opening and closing of the Platform Screen Door will be controlled by wayside signaling system. Unfortunately, we often see the case in news that passengers fall into track and their contact with train lead to critical accidents. However, passengers will be free from such accidents on the platform with the Platform Screen Door System. Especially during the rush hours, to ensure passenger's safety and smooth getting on & off, it is necessary to arrange. some station staffs on the platform without the Platform Screen Door System. On the other hand, the Platform Screen Door System will realize such operation by fewer staffs. Due to the above reasons, the Platform Screen Door System is becoming more popular in subway system recently.

  • PDF

Blower Door Test를 이용한 공동주택 자연환기시스템의 환기성능 분석 (Analysis on Ventilation Performance of Natural Ventilation Systems in Multi-Family Housing Using Blower Door Test)

  • 김민석;어진선;홍구표;김병선
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.129-134
    • /
    • 2016
  • Today, natural ventilation systems are widely applied in multi-family housing. However, studies using the wind data trend line of the blower door test are insufficient. Purpose: Through this study, we will propose a computational method about ventilation performance of natural ventilation systems by conducting blower door test. Method: First, we sealed the gaps between the main systems including the natural ventilation system and conducted the blower door test. Next, the natural ventilation system was opened, the blower door test was conducted, and the difference in air flow rate between when closed and when opened was checked. Blower door test was carried out with a pressure difference of 50 Pa. Result: Therefore, the ventilation performance of the natural ventilation system was checked by drawing a trend line using the data to calculate the air flow rate at 2 Pa of the natural ventilation equipment standard pressure difference.