A study on membrane technology for surface water treatment: Synthesis, characterization and performance test

  • Haan, Teow Yeit;Shah, Mubassir;Chun, Ho Kah;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • v.9 no.2
    • /
    • pp.69-77
    • /
    • 2018
  • The use of membrane as an innovative technology for water treatment process has now widely been accepted and adopted to replace the conventional water treatment process in increasing fresh water production for various domestic and industrial purposes. In this study, ultrafiltration (UF) membranes with different formulation were fabricated via phase inversion method. The membranes were fabricated by varying the polymer concentration (16 wt%, 18 wt%, 20 wt%, and 21 wt%). A series of tests, such as field emission scanning electron microscope (FESEM), pore size and porosity, contact angle, and zeta potential were performed to characterize the membranes. The membrane performance in terms of permeation flux and rejection were evaluated using a laboratory bench-scale test unit with mine water, lake water and tube well as model feed solution. Long hour filtration study of the membranes provides the information on its fouling property. Few pore blocking mechanism models were proposed to examine the behaviour of flux reduction and to estimate the fouling parameters based on different degree of fouling. 21 wt% PVDF membrane with smaller membrane pore size showed an excellent performance for surface water treatment in which the treated water complied with NWQS class II standard.

Water Allocation by Estimation of Damage Function in a Water-Deficit Situation (피해함수 산정을 통한 물 부족 상황에서의 용수배분 방안)

  • Yi, Choong-Sung;Park, Kyo;Choi, Seung-An;Shim, Myung-Pil
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.5 s.166
    • /
    • pp.431-440
    • /
    • 2006
  • Recently, water conflicts are rapidly increasing and more serious. So, it needs to establish the reasonable water allocation rules and criteria. This study aims at performing inter-sectoral water allocation with a focus on economic effciency and social utility. To allocate water among the sectoral water uses, water shortage damage functions were estimated and then converged to the utility functions. Finally, each sectoral water uses are allocated by applying 'law equimarginal utility' to maximize social utility. Also weighting factor which reflects scale and characteristic of water demand in a region was estimated to perform the inter-regional water allocation. The water allocation rule was applied to the future water-deficit situation in Han-river basin. As a result, domestic water use was allocated more sufficient agricultural and industrial water use. Also, the water shortage occurs severely in the rural area like Gangwon-do because of its low urbanization and industrialization. This study suggests a alternative view of the economic water allocation which have difficulty under water supply mechanism in Korea.

A Study on Interferences of Monochloramine in the Measurement of Ammonia by Phenate Method (Phenate 법으로 암모니아 분석시 염화아민의 방해 작용에 관한 연구)

  • Yoon, Je-Yong;Lee, Sang-Duck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.1
    • /
    • pp.45-51
    • /
    • 1998
  • The determinations of ammonia in water for drinking purpose served as one basis of judging the sanitary quality of water for a great many years. However, presently ammonia regulation varies depending on countries. In USA and Canada, ammonia is added to water for chloramination process. However, for korea, there is ammonia regulation of treated water in Korea which should not exceed 0.5mg/l as $NH_3-N$. There was a report exceeding 0.5mg/l of ammonia in chlorinated water when the famous drinking water contamination episode happened in the downstream of Nadong River, 1994. With lack of sewer distribution system and treatment plants of domestic wastes, many water treatment plants have a difficulty of complying with ammonia regulation in treated water. Breakpoint chlorination is usually performed to get rid of ammonia. The method which is allowed to measure ammonia in Korea is Phenate method. However, it would be undesirable to use Phenate method for measuring ammonia in chlorinated water if Phenate method would not differentiate ammonia from chloramine. A good possibility of interferences in measurement of ammonia exists because Phenate method include the step of the formation of chlorine and would not differentiate chloramine which is formed as a result of reaction between chlorine and ammonia. This study was on inaccuracy of Phenate method for measuring ammonia of chlorinated water when chloramine and ammonia coexist. This study found that Phenate method measured all chlormaine as ammonia. Ammonia measurement by ion chromatography confirmed this results. Finally, the result from this study suggests that ammonia measurement by Phenate method in chlorinated water should be revised accordingly.

  • PDF

Current Status of Applied Korean Patents Regarding the Deep Sea Water (해양심층수 관련 국내 특허출원 동향)

  • Chung, Kap-Taeck;Lee, Sang-Hyun
    • The Korean Journal of Food And Nutrition
    • /
    • v.22 no.2
    • /
    • pp.261-271
    • /
    • 2009
  • Deep sea water exists at depths of over 200m under the sea. As no sunlight reaches it, photosynthesis does not take place within it, and it contains no organic matter. In addition, its temperature is maintained at a stable low level throughout the year, so it does not get mixed with the sea water on the surface. It contains a large amount of nutritious salts, whose cleanness is maintained. It is a marine resource that has matured for a long period of time. Research into deep sea water, which started in the 1970s, has been made around the whole world, including the USA and Japan. In Korea, research has been active in this area since 2000. As there has been a good amount of research into industrial applications for deep sea water, since 1993, patents for the relevant technologies have been applied. This paper intends to provide a resource to researchers of deep sea water, by summarizing of all domestic deep sea water-related patents applied with Korean Intellectual Property Office from 1993 to 2008. This research was conducted using a computer and KIPRIS Database owned by the Korea Institute of Patent Information. 'Deep sea water' was used as the search keyword. A total of 222 Korean patents relating to deep sea water have been registered on the basis of IPC. Of these, 126 patents relate to the manufacturing and the treatment of foods, foodstuffs, or non-alcoholic beverages(A23L), while 50 patents relate to the production for medical, dental, or cosmetic purposes(A61K). 38 patents relate to water purification, treatment of wastewater, sewage and sludge (C02F), while 8 patents relate to fishery and farming(A01K). In summary, it was found that studies for the practical use of deep sea water have been conducted in relation to the manufacturing and the treatment of foods, foodstuffs, beverages, and cosmetics.

An Analysis of Housing and Domestic Living of ChoSun-Tribe in China - Focusing on Housing Plans for Immigrant Workers in Korea - (중국 길림성(吉林省)에 거주하는 조선족(朝鮮族)의 주거 및 주생활 - 재한(在韓) 조선족 이주 노동자의 주거 계획을 위한 기초 연구 -)

  • Lee, Young-Shim;Choi, Jung-Shin
    • Journal of the Korean Home Economics Association
    • /
    • v.45 no.7
    • /
    • pp.1-15
    • /
    • 2007
  • The purpose of this study is getting information for making a plan of immigrant workers in Korea. As a first step to suggest plans for immigrant workers who have multi-cultural background, this study investigated to the domestic living of Koreans(ChoSun-Tribe) of Gillim province in China. For this, usage of domestic space questionnaire were used. Results of the research were as follows. 1. The most popular LDK type was the one which kitchen was separated from living room and dining room. Most of them thought that kitchen and living room have to be separated. 2. There was no plan for laundry room specially and most houses have a washing machine in the bathroom. Most houses didn't install a bathtub in the bathroom and they didn't think that it was indispensable. 3. It was estimated that they used a living room as a multi-purpose room for the family but used a master bedroom for its own purpose. 4. They used a table and chair for meals normally but they took meals sitting on the floor with a large family or guest. 5.All of them took off the shoes inside of the house for hygienic reason. There was no plan for the space to take on-off shoes in most houses and they just put the mat on the floor for it. 6. Modified Ondol system which use water pipe under the floor was popular in apartment while most detached houses had traditional Ondol system. The satisfaction about Ondol system was very high compared to other ones and also Ondol system was the most desirable one for ChoSun-Tribe.

A Study on Properties of Domestic Fly Ash and Utilization as an Insulation material (국산 Fly Ash의 특성 및 단열재로의 이용에 관한 연구)

  • 박금철;임태영
    • Journal of the Korean Ceramic Society
    • /
    • v.20 no.2
    • /
    • pp.135-146
    • /
    • 1983
  • This study is to investigate the properties of domestic fly ash for utilization as data in regard to fly ash which is by-product of domestic coal powder plants and the possibility of utilization as insulation material of domestic fly ash. Composition refractoriness size distribution density contents of hollow particles and crystalline phase were examined as the properties of domestic fly ash. As to the fired test pieces of fly ash by itself that varied contents of hollow particles with four kinds and of the fly ash-clay-saw dust system linear shrinkage bulk density app. porosity compressive strength thermal conductivity and structures were investigated for the possibility of utilization as an insulation material. The results are as follows : 1. The properties of the fly ash I) The constituent particle of the fly ash is spherical and it contains not a few hollow particles (floats by water 0.30-0.50 floats by $ZnCl_2$ aq.(SpG=1.71) 6.97-16.72%). ii) The chemical compositions of fly ash are $SiO_243.9-54.1%$ , $Al_2O_321.0-30.7%$ Ig loss is 7.4-24.1% and the principal of Ig loss is unburned carbon. iii) Fly ash was not suitable to use for mortar and concrete mixture because Ig. loss value is higher than 5% 2. Utilization as insulation material I) The test pieces of original fly ash floats by water floats by ZnCl2 aq(SpG=1.71) p, p t by ZnCl2 aq.(SpG=1.71) that were fired at 110$0^{\circ}C$ represented 0.11-0.18 kcal/mh$^{\circ}$ C as thermal conductivity value. ii) The test pieces which (76.5-85.5) wt% fly ash-(8.5, 9.5) wt% clay-(5.0-15.0) wt% saw dust system(68.0-72.0) wt% fly ash -(17.0-18.0)wt% clay-(10.0-15.0) wt% saw dust system and 59.5 wt% fly ash-25.5 wt% clay-15.0wt% saw dust system were fired at 110$0^{\circ}C$ the thermal conductivity was less than 0.1Kcal/mh$^{\circ}$ C. iii) In view of thermal conductivity and economic aspect insulation materials which added saw dust as blowing agent and clay as inorganic binder are better than that of fly ash as it is or separated hollow fly ash particles. iv) When the saw dust contents increased in the (59.5-90.0) wt% saw dust system and when amount of clay de-creased and firing temperature decreased under the condition of equal addition of saw dust app. porosity increased but bulk density compressive strength and thermal conductivity decreased.

  • PDF

A Study on Application of LID Technology for Improvement of Drainage Capacity of Sewer Network in Urban Watershed (도시 유역의 우수관망 통수능 개선을 위한 LID 기술 적용 연구)

  • Baek, Jongseok;Kim, Baekjoong;Lee, Sangjin;Kim, Hyungsan
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.617-625
    • /
    • 2017
  • Both domestic and overseas urban drainage systems have been actively researched to solve the problems of urban flash floods and the flood damage that is caused by local downpours. Recent urban planning has been designed to better manage the floods of decentralized rainfall-management systems, and the installation of green infrastructure and low-impact development (LID) facilities at national ministries has been recommended. In this study, we use the EPA SWMM model to construct a decentralized rainfall-management network for each small watershed, and we analyze the effect of the drainage-capacity improvement from the installation of the LID technologies in vulnerable areas that replaces the network-expansion process. In the design of the existing urban piping systems, it is common to increase the pipe size due to the increment of the impervious area, the steep terrain, and the sensitive entrance-ramp junction; however, the installation of green infrastructure and LID facilities will be sufficient for the construction of a safe urban drainage system. The applications of LID facilities and green infrastructure in urban areas can positively affect the recovery of the corresponding water cycles to a healthy standard, and it is expected that further research will occur in the future.

Management of water quality by estimated the point source in Mokpo inner bay (점 오염원 조사를 통한 목포 내항의 수질관리)

  • Kim, Do-Hee;Lee, Ha-Ju
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.121-128
    • /
    • 2006
  • The results of COD researched on August of 2004 were 6.8 ppm in North Mokpo inner Bay, 4.4 ppm in front of YongSang Bank and 4.6 ppm in front of ShinAn Beach Hotel which is over III level Marine-Environmental Standard. The other five stations sea water quality of Mokpo inner bay were reached II-III level. Concentration of total nitrogen range from 1.23 ppm to 3.56 ppm and total phosphorous was range from 0.07 ppm to 0.12 ppm which were II-III level. This results show that the Mokpo inner bay is unsuitable for aquaculture and growth of fish and for use of marine resort, it can be only available for industrial and harbour use. In results of estimated point source flow into Mokpo inner bay, the occupation ratio from YoungSang river in total inflow of TN and TP were up to 49-89 % respectively. It is indicate that in order to improve the water quality of MokPo inner bay have to control the discharge from YoungSang river first of all, then control the discharge from North Harbour domestic wastewater treatment, InAm river and NamHae domestic wastewater treatment.

  • PDF

Management of Water Quality by the Point Source in Mokpo Inner Bay (점 오염원 조사를 통한 목포 내항의 수질관리)

  • Kim, Do-Hee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.273-283
    • /
    • 2006
  • The results of COD concentration on August of 2004 were 6.80 ppm in North Mokpo Inner Bay, 4.42 ppm un front of YongSang Bank and 4.60 ppm in front of ShinAn Beach Hotel which is over III level Marine Environmental Standard. The others researched five stations sea water quality of Mokpo inner bay are reached II-III level. The concentration of total nitrogen range from 1.23 ppm to 3.56 ppm and total phosphorous concentration was range from 0.07 ppm to 0.12 ppm which are to be II-III level. This results show that the Mokpo inner bay is unsuitable for aquaculture and for use of marine resort, it can be only avaliable for industrial and harbour port use. In this study, we researched 12 point source flow into Mokpo Inner bay. The rate from YoungSang river in total inflow of TN was up to 70-93 % and rate of TP was up to 31-91 % respectively. In this results, we have to control the discharge from YoungSang river first of all then control the discharge from North Harbour domestic wastewater treatment, InAm river and NamHae domestic wastewater treatment in order to improve the water quality of Mokpo Inner bay.

  • PDF

Assessment of EFDC Model for Water Quality Analysis in Nakdong River (EFDC 모형의 낙동강 수질해석 적용성 평가)

  • Choi, Hyun-Gu;Kim, Dong-Il;Na, Chang-Hwan;Han, Kun-Yeun
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.7
    • /
    • pp.685-696
    • /
    • 2012
  • EFDC model, which is capable of handling both hydrodynamic and water quality analysis has come to use for many recent studies. In order to assess the applicability of the EFDC model, it was applied to Nakdong river. Hydrodynamic and water quality analysis were carried out for Nakbon GH and HI sections chosen as the area of study with gaged data from 2008 to 2009. The comparison was made between water quality simulation results and observed data over water temperature, COD, TOC, DO, TN and TP. On the contrary, a conversion formula was derived to calculate BOD which the EFDC model cannot directly calculates and it was compared to measured data. In this study, it was determined that the EFDC model well represents the behavior of both hydrodynamics and water quality. However, further research on COD, TOC and accurate conversion of BOD needs to be conducted for efficient application to domestic water quality analysis.