• Title/Summary/Keyword: Division of working area

Search Result 116, Processing Time 0.027 seconds

A Comparative Analysis on Generated Construction Waste Quantities in a Case Study for Deconstruction of an Apartment (공동주택의 분별해체 시험시공을 통한 건설폐기물 발생량 비교 분석)

  • Kim, Hyojin;Kang, Leenseok;Kim, Changhak
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.6
    • /
    • pp.63-70
    • /
    • 2014
  • Deconstruction of the building must be applied firstly in order to improve recycling and reuse of construction wastes. In this study have done a case study for deconstruction of an apartment. All construction waste(CW) which will be generated during deconstruction was examined in each part of the building. Because drawing did not exist in most of the old building, we drew up floor plans of buildings. After analyzing these drawings, estimated quantities of CW. It was measured working time of labor and equipments for deconstruction and general demolition on each building of the apartment. In addition, it was proposed in the volume and weight per unit after analyzing detailed measurement of CW which was generated in the process of deconstruction and traditional demolition. It suggested recovery rate at a site, volume and weight conversion factors, and waste basic unit per area that based on the results of comparative analysis on the amount of CW which is calculated from drawing and generated at a site. These factors will be used fundamental materials for estimating quantities and treatment cost of CW, and scheduling of works.

Assessing the Positioning Accuracy of High density Point Clouds produced from Rotary Wing Quadrocopter Unmanned Aerial System based Imagery (회전익 UAS 영상기반 고밀도 측점자료의 위치 정확도 평가)

  • Lee, Yong Chang
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.39-48
    • /
    • 2015
  • Lately, Unmanned Aerial Vehicles(UAV), Unmanned Aerial Systems(UAS) or also often known as drones, as a data acquisition platform and as a measurement instrument are becoming attractive for many photogrammetric surveying applications, especially generation of the high density point clouds(HDPC). This paper presents the performance evaluation of a low-cost rotary wing quadrocopter UAS for generation of the HDPC in a test bed environment. Its performance was assessed by comparing the coordinates of UAS based HDPC to the results of Network RTK GNSS surveying with 62 ground check points. The results indicate that the position RMSE of the check points are ${\sigma}_H={\pm}0.102m$ in Horizonatal plane, and ${\sigma}_V={\pm}0.209m$ in vertical, and the maxium deviation of Elevation was 0.570m within block area of ortho-photo mosaic. Therefore the required level of accuracy at NGII for production of ortho-images mosaic at a scale of 1:1000 was reached, UAS based imagery was found to make use of it to update scale 1:1000 map. And also, since this results are less than or equal to the required level in working rule agreement for airborne laser scanning surveying of NGII for Digital Elevation Model generation of grids $1m{\times}1m$ and 1:1000 scale, could be applied with production of topographic map and ortho-image mosaic at a scale of 1:1000~1:2500 over small-scale areas.

Development of Dry Process Caisson Method for Maintenance of Submerged Harbor Structure (수중 항만구조물의 유지보수를 위한 건식 케이슨 공법 개발)

  • Lee Joong-Woo;Oh Dong-Hoon;Kwak Seung-Kyu;Kim Sung-Tae
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.163-170
    • /
    • 2006
  • Together with the trend of enhancement in domestic industrial development and economic progress due to import and export, the demand for construction of the roads, bridges, especially port facilities, and several coastal protection and ocean structures is increasing rapidly. MOMAF of Korean Government is driving construction of 9 new ports and renovation of the existing fishery ports. Among these structures most of bridge base, wharves, dolphins, quays, and jetties are being newly built of steel or concrete pile. As the base, supporting bulkheads, and piles are underwater after construction, it is difficult to figure out the status of structures and not enough to get maintenance and strengthen the structures. Every year, moreover, these works suck the government budget due to higher incomplete maintenance expense for protection from corrosions of structures and increased underwater construction period. For the purpose of cutting down the expense of government budget, it is necessary to extend the life cycle of the existing structures. Therefore, we developed a new method for maintenance of submerged structures near the waterline by allowing dry work environment with the floating caisson. The method shows easy to move around the working area and handle. It also showed not only a significant reduction maintenance expenses and time for anti-corrosion work but also better protection. This will be a milestone to reduce the maintenance and construction expenses for the shore and water structures.

  • PDF

Analysis of an internal flow with multi-perforated tube geometry in an integrated Urea-SCR muffler (다공튜브 형상변화에 따른 촉매 삽입형 Urea-SCR 머플러 내부유동 해석)

  • Moon, Namsoo;Lee, Sangkyoo;Lee, Jeekeun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.500-509
    • /
    • 2013
  • This study reports a numerical analysis of the internal flow characteristics of the integrated urea-SCR muffler system with the various geometries of the multi-perforated tube which is set up between the muffler inlet and in front of SCR catalysts. The multi-perforated tube is generally used to disperse uniformly the urea-water solution spray and to make better use of the SCR catalyst, resulting in the increased $NO_x$ reduction and decreased ammonia slip. The effects of the multi-perforated tube orifice area ratios on the velocity distributions in front of the SCR catalyst, which is ultimately quantified as the uniformity index, were investigated for the optimal muffler system design. The steady flow model was applied by using a general-purpose commercial software package. The air at the room temperature was used as a working fluid, instead of the exhaust gas and urea-water solution spray mixture. From the analysis results, it was clarified that the multi-perforated tube geometry sensitively affected to the formation of the bulk swirling motion inside the plenum chamber set in front of the SCR catalyst and to the uniformity index of the velocity distribution produced at the inlet of the catalyst.

Development of Dry Process Caisson Method for Maintenance of Submerged Harbor Structure (수중 항만구조물의 유지보수를 위한 건식 케이슨 공법 개발)

  • Lee Joong-Woo;Oh Dong-Hoon;Kwak Seung-Kyu;Kim Sung-Tae
    • Journal of Navigation and Port Research
    • /
    • v.30 no.6 s.112
    • /
    • pp.447-455
    • /
    • 2006
  • Together with the trend of enhancement in domestic industrial development and economic progress due to import and export, the demand for construction of the roads, bridges, especially port facilities, and several coastal protection and ocean structures is increasing rapidly. MOMAF of Korean Government is driving construction cf 9 new ports and renovation cf the existing fishery ports. Among these structures most of bridge base, wharves, dolphins, quays, and jetties are being newly built cf steel or concrete pile. As the base, supporting bulkheads, and piles are underwater after construction, it is difficult to figure out the status of structures and not enough to get maintenance and strengthen the structures. Every year, moreover, these works suck the government budget due to higher incomplete maintenance expense for protection from corrosions cf structures and increased underwater construction period. For the purpose cf cutting down the expense cf government budget, it is necessary to extend the life cycle of the existing structures. Therefore, we developed a new method for maintenance of submerged structures near the waterline by allowing dry work environment with the floating caisson. The method shows easy to move around the working area and handle. It also showed not only a significant reduction of maintenance expenses and time for anti-corrosion work but also better protection This will be a milestone to reduce the maintenance and construction expenses for the shore and water structures.

A Vibration Evaluation and Improvement Scheme for Open Test Blasting (노천시험발파의 진동평가와 개선방안)

  • Kim, Eung-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.310-315
    • /
    • 2017
  • Although studies evaluating the effects of the blasting vibration on the adjacent structures from various angles have continued, cases of securing the safety of the adjacent buildings and researching the proper blasting method for the field condition by analyzing the vibration waveform of the measuring field while performing the open pit blasting are poor. Therefore, it is necessary to present a remedy for blasting pattern selection through test blasting that is appropriate for field conditions, and is economical and efficient. In this study, open pit blasting work was conducted based on the separation distance applied according to the standard blasting method by test blasting and the vibration regulation standard in the road expansion construction site to measure the blasting vibration value, and the vibration prediction equation by blasting methods was examined using a regression analysis computer program to calculate K, N, and R of the confidence level 95%. By setting the blasting allowed vibration standard of the test blasting target area to 0.3cm/sec, and the charring weight and blasting method by the separation distances according to the blasting vibration estimation equation of the open pit blasting guideline and the blasting vibration estimation equation of the test blasting were compared/analyzed, it was possible to identify the factors that increased the working expenses. In addition, the measurement and analysis of the adjacent structures during open pit blasting and the blasting vibration were performed after selecting the most adjacent structure to the open pit blasting spot to analyze the problems on the test blasting procedure and analysis method in the open pit blasting design/construction guidelines, which appeared in the process of completing open pit blasting construction, and a remedy is presented.

A Study on the Librarian's Recognition of the National Library of Korea about YALSA's Competencies for Librarians Serving Youth (청소년 담당 사서의 역량에 대한 국립중앙도서관 사서의 인식에 관한 연구)

  • Noh, Dong-Jo
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.44 no.3
    • /
    • pp.199-218
    • /
    • 2010
  • This study evaluates YALSA's Competencies for Librarians Serving Youth: Young Adults Deserve the Best announced at the Young Adult Library Services Association(YALSA), a division of the American Library Association(ALA) on January 2010. For this study, we investigated fifth librarians working at the National Library of Korea to find out the requirements, effectiveness, and difficulties regarding seven areas and forth-eight detailed qualifications indicated by YALSA's Competencies for Librarians Serving Youth through survey. The results show that the more important areas required for youth services librarians were identified as knowledge of materials, administration, leadership and professionalism. Difficult areas of competencies are communication, marketing and outreach. Analysis of forty-eight detailed qualifications according to their importance and the level of difficulty shows that the more important areas are A4(encourage young adults to become lifelong library users by helping them to discover what libraries offer, how to use library resources, and how libraries can assist them in actualizing their overall growth and development) and A1(develop and demonstrate leadership skills in identifying the unique needs of young adults and advocating for service excellence, including equitable funding and staffing levels relative to those provided for adults and children), while the most difficult area of competencies is C4(Design, implement, and evaluate a strategic marketing plan for promoting young adult services in the library, schools, youth-serving agencies and the community at large).

Nutrition Teachers (Dietitians)' Perceptions of Barriers to Implementation of HACCP System in School Foodservices in the Gyeongnam Area (경남지역 학교급식 HACCP 시스템 적용 장애요인에 대한 영양(교)사의 인지도 분석)

  • Hwang, Hye-Ok;Kim, Hyun-Ah
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.10
    • /
    • pp.1475-1485
    • /
    • 2012
  • This study was conducted in order to understand nutrition teachers (dietitians)' perceptions of barriers to implementation of HACCP system in school foodservices in Gyeongnam, Korea. Questionnaires were distributed to 350 nutrition teachers (dietitians) from November to December of 2009, and 214 were collected and analyzed. The results of this study were as follows. First, nutrition teachers (dietitians) recognized the following as barriers in implementing the HACCP system: 'the status of facilities and utilities'> 'monitoring'> 'work satisfaction'> 'foodservice employees'> 'cooperation of HACCP team'> 'cooperation of persons concerned besides foodservice employees'> 'understanding the HACCP system'. Second, total working experience was found to be the factor most affecting 'cooperation of HACCP team (p<0.01)', 'cooperation of persons concerned besides foodservice employees (p<0.01)', 'foodservice employees (p<0.05)', and 'work satisfaction (p<0.05)'. Further, 'the status of facilities and utilities' was significantly affected by 'construction/reconstruction of kitchen (p<0.01)', 'division of kitchen area (p<0.01)', 'existence of preliminary preparation room (p<0.01)', and 'existence of dishwashing room (p<0.01)'. Third, dietitians perceived the following concerning hindrance factors of the HACCP system according to CCP stage: 'CCP 1'> 'CCP 3'> 'CCP 2, 'CCP 6'> 'CCP 4'> 'CCP 8'> 'CCP 7'> 'CCP 5'. In conclusion, this study showed that nutrition teachers (dietitians) in the Gyeongnam area recognized 'the status of facilities and utilities' from HACCP areas and 'CCP 1 (menu planning)' from CCP stages as the greatest barriers to implementing the HACCP system in school foodservices. To implement the HACCP system successfully in school foodservices, facilities and utilities should be properly equipped, and menu planning training for nutrition teachers (dietitian) should be conducted.

Need Assessment for Enlargement of Oriental Medical Care Service Room in Rural Community Health Center (농촌지역 보건소 한방진료실 확대설치 요구도 및 관련요인 - 일개 군 보건소 한방진료실 내소자를 대상으로 -)

  • Kim, Dae-Feel;Song, Mi-Sook;Song, Hyun-Jong
    • Journal of agricultural medicine and community health
    • /
    • v.28 no.1
    • /
    • pp.39-51
    • /
    • 2003
  • Objectives: The oriental medical care has been getting popular in community health centers because of uniqueness, changing of disease patterns, and increasing of elderly population. From 1998, oriental medical doctors has been working in several rural community health centers for their military obligations. At this point of time, it is necessary to evaluate the oriental public health doctors system. This study was performed to investigate the utilization patterns, the degree of satisfactions, needs of oriental medical care service provided by community health center in a designated Gun area. This study focused on the need for extending over Myun area of community health center's oriental medical care services. Methods: Person-to-person interview survey method through a structured questionnaire was done by a personnel at a oriental medical care service room in a Gun community health center. The major statistical method used for the analysis were the t-test, ANOVA, and logistic analysis. Results: The total number of responded subjects in this study was 163 residents. Among these 65.0% were aged 61 or over, and only 13.5% recognized themselves were healthy. 73.7% of the respondents demanded establishment of more oriental medical care services provided by community health center to other Myun area. Factors affecting the need for enlargement of oriental medical care service room were education level, subjective awareness of access to community health center, and cost satisfaction of oriental medical service provided by community health center. Thus, a resident who had graduation of middle school achievement or above(OR=3.35), had a long way to center(OR=2.47), satisfied with oriental medical service cost(OR=2.78) had demonstrated increased chance of need by logistic regression analysis.

  • PDF

Determination of Optimized Operational Parameters for Photocatalytic Oxidation Reactors Using Factorial Design (요인분석법을 이용한 광촉매 산화반응조의 최적 운영인자 도출)

  • Hur, Joon-Moo;Cheon, Seung-Yul;Rhee, In-Hyoung;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.2
    • /
    • pp.85-91
    • /
    • 2004
  • The objective of this study is to determine the optimum conditions of operational parameters using factorial design for phenol degradation in photocatalytic oxidation reactors. Factorial design is widely used to select the dominant factors and their ranges in experiments involving several factors where it is necessary to study the effect of factors on a response. The effects of initial concentration of phenol, intensity of UV light and surface area of catalyst on phenol degradation were investigated. Two levels were considered in this study so that the experiment was a $2^3$ factorial design with three replicates. The experimental results show that an increase in initial concentration of phenol from 5 to 50 mg/L intensity of UV light from 5,000 to $20,000\;{\mu}W/cm^2$, and surface area of catalyst from 740 to $2,105\;cm^2$ enhanced the phenol degradation rate by an average of 1.86, 1.79, and 2.10 mg/L hr, respectively. Interaction effects do not appear to be as large on the phenol degradation rate as the main effects of single factors. The optimum working condition for photocatalytic oxidation reactors, despite the higher three factors the better removal rate, is the highest surface area or catalyst.