• 제목/요약/키워드: Diurnal Deviation

검색결과 19건 처리시간 0.026초

부산 해안지역의 고농도 오존 발생 특성에 관한 연구 (Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea)

  • 전병일
    • 한국환경과학회지
    • /
    • 제9권4호
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

부산 동삼동 지역의 지표오존농도 특성 연구 (A Study on the Characteristics of Surface Ozone Concentration at Dongsamdong, Pusan)

  • 전병일
    • 환경영향평가
    • /
    • 제8권2호
    • /
    • pp.21-29
    • /
    • 1999
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone and meteorological data of 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was highest in Spring(35.4ppb) and lowest in Winter(22.2ppb). Relative standard deviation indicating clearness of observation site was 0.42 that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong showed maximum at 15~16LST and minimum 07~08LST that typical pattern of ozone concentration. In ozone episode period(May 18~23, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface.

  • PDF

풍속고도분포지수 산정 및 불확도 평가 - 제주도 사례 (Calculation of Vertical Wind Profile Exponents and Its Uncertainty Evaluation - Jeju Island Cases)

  • 김유미;김현구;강용혁;윤창열;김진영;김창기;김신영
    • 한국태양에너지학회 논문집
    • /
    • 제36권4호
    • /
    • pp.11-20
    • /
    • 2016
  • For accurate wind resource assessment and wind turbine performance test, it is essential to secure wind data covering a rotor plane of wind turbine including a hub height. In general, we can depict wind speed profile by extrapolating or interpolating the wind speed data measured from a meteorological tower where multiple anemometers are mounted at different heights using a power-law of wind speed profile. The most important parameter of a power-law equation is a vertical wind profile exponent which represents local characteristics of terrain and land cover. In this study, we calculated diurnal vertical wind profile exponents of 8 locations in Jeju Island who possesses excellent wind resource according to the GUM (Guide to the Expression of Uncertainty in Measurement) to evaluate its uncertainty. Expanded uncertainty is calculated by combined standard uncertainty, which is the result of composing type A standard uncertainty with type B standard uncertainty. Although pooled standard deviation should be considered to derive type A uncertainty, we used the standard deviation of vertical wind profile exponent of each day avoiding the difficult of uncertainty evaluation of diurnal wind profile variation. It is anticipated that the evaluated uncertainties of diurnal vertical wind profile exponents at 8 locations in Jeju Island are to be registered as a national standard reference data and widely used in the relevant areas.

목본식물 형성층 전기저항에 영향을 주는 환경 요인 (Effects of Environmental Factors on the Cambial Electrical Resistance of Woody Plants)

  • 김동욱;김민수;이부용
    • 한국조경학회지
    • /
    • 제35권3호
    • /
    • pp.105-113
    • /
    • 2007
  • This study was conducted to analyze the effects of environmental factors such as soil moisture, light intensity, temperature and humidity on changes in cambial electrical resistance. To improve data quality, cambial electrical resistance was continuously measured at fixed points by using a data logger isolated from alternating current. The relationship between environmental factors and changes in cambial electrical resistance was also analyzed. The results are as follows: 1. Cambial electrical resistance is highly correlated to the temperature of the measured area(r=-0.934). Therefore, temperature compensation is needed to analyze the effects of other environmental factors on cambial electrical resistance changes. 2. If temperature is compensated for, the change of cambial electrical resistance is highly correlated to water vapor pressure(r=-0.836). 3. If temperature and humidity are compensated for, the change of cambial electrical resistance is highly correlated to intensity of light(r=-0.738). 4. Diurnal deviation of soil water potential is not more significantly related than the change of cambial electrical resistance. However, in the long-term, soil water potential and cambial electrical resistance are highly correlated(r=-0.831). This indicates that soil moisture significantly influences the long-term change of cambial electrical resistance.

Diurnal Variation in Hydration of the Cervical Intervertebral Disc Assessed Using T2 Mapping of Magnetic Resonance Imaging

  • Chanyuan Liu;Jingyi Wang;Bowen Hou;Yitong Li;John N. Morelli;Peisen Zhang;Jun Ran;Xiaoming Li
    • Korean Journal of Radiology
    • /
    • 제23권6호
    • /
    • pp.638-648
    • /
    • 2022
  • Objective: The study aimed to investigate the diurnal variation in cervical disc hydration and its relationship with cervical degeneration. Materials and Methods: C3-C7 discs of 86 prospectively enrolled participants (37 males, 49 females; mean age ± standard deviation, 23.5 ± 2.5 years) were assessed using T2 mapping in the morning and evening. All discs were stratified by Miyazaki grade or C2-C7 Cobb angle and T2 values (T2). The degree of diurnal T2 variation (T2-DDV), defined as (morning T2 - evening T2)/morning T2 x 100%, was measured for the entire disc, annulus fibrosus (AF), nucleus pulposus (NP), and endplate zones. Results: T2 of the entire disc decreased significantly after the daytime load (p < 0.001), with a T2-DDV of 13.3% for all discs and 16.0%, 12.2%, and 13.0% for healthy (grade I), mild degenerative (grade II), and advanced degenerative (grade III/IV) discs, respectively. T2 of regional NPs and AFs decreased significantly from morning to evening (p ≤ 0.049) except in the healthy anterior inner AF (p = 0.092). Compared with healthy discs, mild degenerative discs displayed lower T2 and T2-DDV in regional NPs (p < 0.001). Advanced degenerative discs showed higher T2-DDV in the anterior inner AF compared with healthy discs (p = 0.050). Significant diurnal T2 changes in the endplate zones were observed only in healthy discs (p = 0.013). Cervical discs in the low Cobb angle group showed higher T2-DDV in the anterior AFs and anterior NP and lower T2-DDV in the posterior AF than those in the high Cobb angle group (p ≤ 0.041). Conclusion: This study characterized the diurnal variation in hydration of the cervical discs as assessed using T2 mapping and revealed early chemo-mechanical coupling dysfunction in degenerating discs. Cervical sagittal alignment on MRI can affect the diurnal stress patterns of the cervical discs. T2 mapping is sensitive to disc biomechanical dysfunction and offers translational potential from biomechanical research to clinical application.

Comparison of the Characteristics of Precipitable Water Vapor Measured by Global Positioning System and Microwave Radiometer

  • Sohn, Dong-Hyo;Park, Kwan-Dong;Won, Ji-Hye;Cho, Jung-Ho;Roh, Kyoung-Min
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권1호
    • /
    • pp.1-10
    • /
    • 2012
  • In this study, global positioning system (GPS)-derived precipitable water vapor (PWV) and microwave radiometer (MWR)-measured integrated water vapor (IWV) were compared and their characteristics were analyzed. Comparing those two quantities for two years from August 2009, we found that GPS PWV estimates were larger than MWR IWV. The average difference over the entire test period was 1.1 mm and the standard deviation was 1.2 mm. When the discrepancies between GPS PWV and MWR IWV were analyzed depending on season, the average difference was 0.7 mm and 1.9 mm in the winter and summer months, respectively. Thus, the average difference was about 2.5 times larger in summer than that in winter. However, MWR IWV measurements in the winter months were over-estimated than those in the summer months as the water vapor content got larger. The results of the diurnal analysis showed that MWR IWV was underestimated in the daytime, showing a difference of 0.8 mm. In the early morning hours, MWR IWV has a tendency to be over-estimated, with a difference of 1.3 mm with respect to GPS PWV.

월령 연안지역 대기경계층의 유동특성과 대기 안정성에 대한 고찰 (Estimation on The Atmospheric Stability and Flow Characteristics of Planetary Boundary Layer in Wolryong Coastal Region)

  • 정태윤;임희창;김현구;장문석
    • 한국환경과학회지
    • /
    • 제18권8호
    • /
    • pp.857-865
    • /
    • 2009
  • The physical properties of an atmospheric boundary layer in Wolryong, a west coastal region of Jeju, South Korea, in terms of the atmospheric stability and roughness length, is important and relevant to both engineers and scientists. The study is aiming to understand the atmospheric stability around this region and its effect on the roughness length. We calculate the Monin-Obukhov length(L) against 3 typical regions of the atmospheric condition - unstable regime (-5$-0.2{\leq}H/L{\leq}0.2$) and stable regime (0.2

SST 효과를 고려한 계절별 $NO_2$농도 수치모의 (Numerical Simulation of $NO_2$Concentration considering SST Effects)

  • 원경미;이화운;김유근
    • 한국환경과학회지
    • /
    • 제10권3호
    • /
    • pp.187-194
    • /
    • 2001
  • For the purpose of predicting air pollutants concentration in Pusan coastal urban, we used an Eulerian model of flow and dispersion/chemistry/deposition process considering SST effects which estimate through POM. The results of air quality model including emission from various sources show that the seasonal variation pattern of respective pollutants was affected by the seasonal SST fields and local circulation. Horizontal deviation of diurnal SST was 2.5~4K, especially large gradients in coastal region. Through numerical simulation of wind fields we predicted that local circulation prevailed during daytime in summer and nighttime in winter. So high concentration distribution showed toward inland in spring and summer seasons, while high concentration distribution showed at inland near coast in autumn and winter.

  • PDF

지자기이상을 이용한 동해 독도 및 독도주변의 구조와 성인에 관한 고찰 (A Study on the Structure and Origin of the Dokdo and it's Surroundings in the East Sea (Japan Sea) Using Magnetic Anomalies)

  • 김창환;박찬홍;민경덕;한현철;권문상;심재설;최성호;오순복
    • Ocean and Polar Research
    • /
    • 제24권4호
    • /
    • pp.491-500
    • /
    • 2002
  • Magnetic anomalies in the Dokdo and it's surroundings were investigated with respect to structure and origin of the Dokdo and surrounding seamounts. After normal and diurnal correction of measured magnetic data, crossover correction was applied to reduce errors between sets of magnetic anomalies. The errors from crossover operation result in decrease of about 51%, from 62.2 nT to 30.1 nT in standard deviation. Reduction-to-the-pole, second vertical derivative and analytic signal processing were applied to explore magnetic anomaly signatures in detail. Magnetic anomalies are most complicated in the 1st-Dok seamount, show SWW-NEE linear pattern in the 2nd-Dok seamount and lower to the 3rd-Dok seamount. Different magnetic anomaly patterns in three seamounts imply that three volcanic seamounts were formed at different times and are composed of rocks that were produced in different conditions. It seems that the 3rd-Dok seamount was first to form and followed by the 1st-Dok seamount. The complicated magnetic and second vertical derivative anomaly patterns in the 1st-Dok seamount may be due to subsidiary cones around crater or the presence of intruded magma bodies below sea surface and the Dokdo is probably a marginal subsidiary part of crater.

On the Variability of the Ionospheric F2-Layer During the Quietest Days in December 2009

  • Kim, Vitaly P.;Hegai, Valery V.
    • Journal of Astronomy and Space Sciences
    • /
    • 제33권4호
    • /
    • pp.273-278
    • /
    • 2016
  • December 2009 was one of the quietest (monthly Ap=2) months over the last eight decades. It provided an excellent opportunity to study the day-to-day variability of the F2 layer with the smallest contribution due to geomagnetic activity. With this aim, we analyze hourly values of the F2-layer critical frequency (foF2) recorded at 18 ionosonde stations during the magnetically quietest (Ap=0) days of the month. The foF2 variability is quantified as the relative standard deviation of foF2 about the mean of all the "zero-Ap" days of December 2009. This case study may contribute to a more clear vision of the F2-layer variability caused by sources not linked to geomagnetic activity. In accord with previous studies, we find that there is considerable "zero-Ap" variability of foF2 all over the world. At most locations, foF2 variability is presumably affected by the passage of the solar terminator. The patterns of foF2 variability are different at different stations. Possible causes of the observed diurnal foF2 variability may be related to "meteorological" disturbances transmitted from the lower atmosphere or/and effects of the intrinsic turbulence of the ionosphere-atmosphere system.