• Title/Summary/Keyword: Distribution power networks

검색결과 262건 처리시간 0.029초

수지상 배전계통을 단일루프로 구조 변경시 신뢰도 비교 (The Comparison of Reliability for Change Single Loop Configuration in Radial Power Distribution System)

  • 이희태;김재철;김주용
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1472-1478
    • /
    • 2009
  • The domestic power distribution system is operating in an open loop mode; however, it already has a loop structure. Power distribution systems must be changed for bi-directions power supply for smart networks due to a changing of paradigm in electric power industry. The simplest bi-directions distribution networks can make it closing of normally open switch. However, bi-directions power supply is very difficulty to be operated and there are many parts which it must study. This paper presented various models that are able to change a radial system for loop structures. Further, we compared the reliability index for each model by evaluating the amount of improvement reliability required in radial power distribution system. In addition, we calculated CIC(Customer Interruption Cost) for each model by comparing and analyzing.

3상회로의 직접해석에 의한 송배전계통 선간단락 사고 고장거리 계산 알고리즘 (A New Line to Line Fault Location Algorithm in Distribution Power Networks using 3 Phase Direct Analysis)

  • 최면송;이승재;임성일;진보건;이덕수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권9호
    • /
    • pp.467-473
    • /
    • 2002
  • In this paper, a fault location algorithm is suggested for line to line faults in distribution networks. Conventional fault location algorithms use the symmetrical component transformation, a very useful tool for transmission network analysis. However, its application is restricted to balanced network only. Distribution networks are, in general, operated in unbalanced manners, therefore, conventional methods cannot be applied directly, which is the reason why there are few research results on fault location in distribution networks. Especially, the line to line fault is considered as a more difficult subject. The proposed algorithm uses direct 3-phase circuit analysis, which means it can be applied not only to balanced networks but also to unbalanced networks like distribution a network. The comparisons of simulation results between one of conventional methods and the suggested method are presented to show its effectiveness and accuracy.

Integrated Voltage and Power Flow Management Considering the Cost of Opera in Active Distribution Networks

  • Xu, Tao;Guo, Lingxu;Wei, Wei;Wang, Xiaoxue;Wang, Chengshan;Lin, Jun;Li, Tianchu
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.274-284
    • /
    • 2016
  • The increasing penetration of distributed energy resources on the distribution networks have brought a number of technical impacts where voltage and thermal variations have been identified as the dominant effects. Active network management in distribution networks aims to integrate distributed energy resources with flexible network management so that distributed energy resources are organized to make better use of existing capacity and infrastructure. This paper propose active solutions which aims to solve the voltage and thermal issues in a distributed manner utilizing a collaborative approach. The proposed algorithms have been fully tested on a distribution network with distributed generation units.

Energy Efficient IDS Node Distribution Algorithm using Minimum Spanning Tree in MANETs

  • Ha, Sung Chul;Kim, Hyun Woo
    • 스마트미디어저널
    • /
    • 제5권4호
    • /
    • pp.41-48
    • /
    • 2016
  • In mobile ad hoc networks(MANETs), all the nodes in a network have limited resources. Therefore, communication topology which has long lifetime is suitable for nodes in MANETs. And MANETs are exposed to various threats because of a new node which can join the network at any time. There are various researches on security problems in MANETs and many researches have tried to make efficient schemes for reducing network power consumption. Power consumption is necessary to secure networks, however too much power consumption can be critical to network lifetime. This paper focuses on energy efficient monitoring node distribution for enhancing network lifetime in MANETs. Since MANETs cannot use centralized infrastructure such as security systems of wired networks, we propose an efficient IDS node distribution scheme using minimum spanning tree (MST) method to cover all the nodes in a network and enhance the network lifetime. Simulation results show that the proposed algorithm has better performance in comparison with the existing algorithms.

Development of an Adaptive Overcurrent Relaying Algorithm for Distribution Networks Embedding a Large Scaled Wind Farm

  • Jang, Sung-Il;Kim, Ji-Won;Kim, Kwang-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권4호
    • /
    • pp.198-205
    • /
    • 2003
  • This paper proposes the adaptive relaying of protective devices applied in the neighboring distribution feeders for reliable and efficient operations of a wind farm interconnected with distribution networks by dedicated lines. A wind farm connected to an electric power network is one of the greatest alternative energy sources. However, the wind turbine generators are influenced by abnormal grid conditions such as disturbances occurring in the neighboring distribution feeders as well as the dedicated power. Particularly, in cases of a fault happening in the neighboring distribution feeders, a wind farm might be accelerated until protective devices clear the fault. Therefore, the delayed operation time of protective devices for satisfying the coordination might overly expose the interconnected wind turbine generators to the fault and cause damage to them. This paper describes the proper delayed operation time of protective relay satisfying the coordination of the distribution networks as well as reducing damage on the interconnected wind farm. The simulation results for the Hoenggye substation model composed of five feeders and one dedicated line using PSCAD/EMTDC showed that the proper delayed time of protective devices reflecting the fault condition and the power output of the wind farm could improve the operational reliability, efficiency, and stability of the wind farm.

A Study on the Effect of Distributed Generation of the Reconfiguration of Distribution Networks

  • Nguyen, Tung Linh;Trinh, Trong Chuong;Truong, Viet Anh
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1435-1441
    • /
    • 2017
  • Distributed generation (DG) in the future will play an important role in the electricity supply systems, in wich can provide DG capacity from a few hundred kW to tens of MW. However, it is connected to the local power grid, DG will have certain influence on the power quality of the power grid. One of the most significant effects is that they will change the configuration of the local power grid as well as affecting the operation mode of the grid. This paper presents a method of finding the optimal open loop, analyzing and selecting the appropriate mode of operation to reduce power losses of power distribution networks that includes DG.

Improved Grid Voltage Control Strategy for Wind Farms with DFIGs Connected to Distribution Networks

  • Zhang, Xueguang;Pan, Weiming;Liu, Yicheng;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.495-502
    • /
    • 2012
  • This paper presents an improved grid voltage control strategy for wind farms with doubly-fed induction generators (DFIGs) connected to distribution networks based on an analysis of the operation limits of DFIG systems. A modified reactive power limit calculation method in different operation states is proposed and a reactive power control strategy during grid voltage dips/rises is further discussed. A control strategy for compensating unbalanced grid voltage, based on DFIG systems, by injecting negative sequence current into the grid through the grid side converter (GSC) is proposed. In addition, the negative current limit of the GSC is discussed. The distribution principle of the negative sequence current among the different DFIG systems in a wind farm is also introduced. The validity of the proposed voltage control strategy is demonstrated by Matlab/Simulink simulations. It is shown that the stability of a wind farm and the power grid can be improved with the proposed strategy.

분산전원 보호용 디지털 보호계전기 개발 (Development of the digital protection relay for protecting distributed generation)

  • 조철희;이병호;오의석;고철진;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.181-183
    • /
    • 2005
  • The existing distribution networks are growing with an increase of power demand more and more. Therefore, for efficient operation of distribution networks, operators are much in need of distributed generation. This paper describes a development of the digital protection relay(HIMAP) for protecting distributed generation which is expected to play an increasing role in electric power systems in the near future. This paper particularly introduces frequency protective algorithm and reverse power protective algorithm among the relaying algorithms for protecting distributed generation in distribution networks and resents capability of a developed digital protection relay including these algorithms.

  • PDF

Artificial neural network reconstructs core power distribution

  • Li, Wenhuai;Ding, Peng;Xia, Wenqing;Chen, Shu;Yu, Fengwan;Duan, Chengjie;Cui, Dawei;Chen, Chen
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.617-626
    • /
    • 2022
  • To effectively monitor the variety of distributions of neutron flux, fuel power or temperatures in the reactor core, usually the ex-core and in-core neutron detectors are employed. The thermocouples for temperature measurement are installed in the coolant inlet or outlet of the respective fuel assemblies. It is necessary to reconstruct the measurement information of the whole reactor position. However, the reading of different types of detector in the core reflects different aspects of the 3D power distribution. The feasibility of reconstruction the core three-dimension power distribution by using different combinations of in-core, ex-core and thermocouples detectors is analyzed in this paper to synthesize the useful information of various detectors. A comparison of multilayer perceptron (MLP) network and radial basis function (RBF) network is performed. RBF results are more extreme precision but also more sensitivity to detector failure and uncertainty, compare to MLP networks. This is because that localized neural network could offer conservative regression in RBF. Adding random disturbance in training dataset is helpful to reduce the influence of detector failure and uncertainty. Some convolution neural networks seem to be helpful to get more accurate results by use more spatial layout information, though relative researches are still under way.

멀티에이전트 시스템을 이용한 배전계통 사고복구시스템에 관한 연구 (A study on Service Restoration Systems for Power Distribution Networks by Applying Multi-Agent System)

  • 정광호;최면송;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.403-405
    • /
    • 2004
  • A service restoration is one of the most important missions in distribution system operation. This paper proposes a multi-agent system approach to distribution system restoration. Every relay is developed as an agent by adding its own intelligent, self-tuning and communication ability. Relay agent calculates and corrects its restoration index by itself through communication with neighboring agents and its own intelligence. The proposed algorithm is applied to a simple network to show how to calculate restoration index. Keywords Multi-Agent System, Service Restoration, Distribution Networks

  • PDF