• 제목/요약/키워드: Distribution pipe

검색결과 620건 처리시간 0.026초

부식 생성물 분석법을 이용한 상수도 금속관의 부식거동에 관한 연구 (Study of Drinking water pipeline Corrosion Mechanism by using Scale Analysis)

  • 황상용;송호봉
    • 환경위생공학
    • /
    • 제17권1호
    • /
    • pp.57-62
    • /
    • 2002
  • Carbon cast iron and Zinc coated steel were the most widely used portable water of supply and distribution Pipeline system. The leaching of red water in portable water could produce sericus environmental sanitary problems. Due to the red water was the most alternative to inner scale of metal pipeline. So this study was conducted the impact of red water on scale products, and was evaluated by the corrosive metal contaminants of 20 fears over. Surface tests, metal surface composition measurements of samples XRF, XRD, and SEM(EDS), analysis were used to investigate the corrosion characteristies of carbon cast iron and Zinc coated steel. As the contaminants of Fe increased the red water of carbon castiron pipe increased due to the scale products amount of $Fe_2O_3$ (Hemite).

Tandem 용접을 이용한 풍력타워 원주용접부 잔류응력 특성에 관한 연구 (A Study on Characteristic of Residual Stresses in a wind Tower Using the Tandem Circumferential Welding Process)

  • 김지선;김인주
    • 한국생산제조학회지
    • /
    • 제21권6호
    • /
    • pp.938-945
    • /
    • 2012
  • This research proposes FEM analysis for Tandem welding process used in wind tower and predicts optimal welding process to improve the stability of welded structures. Three dimensional elasto-plastic analyses are employed to evaluate thermo-mechanical behavior of residual stress and deformation during Tandem welding for different distance between two touches. To confirm the thermal distribution, Goldak's ellipse heat source model and the real size wind tower pipe model are utilized. Four different analyses are being performed, where in each case the distance between two electrode torches is being changed and residual stress and welding deformation are predicted. Depending on base material state, each case is divided into: Liquid (100mm), Austenite+Liquid (200mm), Austenite+Cementite (400mm), Pearlite+Cementite (800mm).

수직으로 매설된 이중관형 지중 열교환기에 대한 해석적인 연구 (Numerical analysis of the vertical tube-in-tube ground coil heat exchanger)

  • 유지오;금성민;신현준
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.339-348
    • /
    • 1999
  • A computer model was developed in order to predict the temperature distribution and the performance of the vertical tube-in-tube ground coil heat exchanger. This model has been validated by experimental results conducted by ORNL. The heat exchanger performance with the variation of the length is calculated and compared. As results, the heat exchanger performance is proportional to the length but the performance per unit length decreases. The minimum performance of 70m - PVC heat exchanger during cyclic operation for a week is obtained 20,054kJ/h for cooling operation and 13,915kJ/h for heating operation. And minimum temperature difference is $4.64^{\circ}C$ for cooling operation and $2.64^{\circ}C$ for heating operation. In each case, it is noted that the temperature difference between the pipe and the far-field occurs within 0.8m from the heat exchanger.

  • PDF

Retrofit Design of Damaged Prestressed Concrete Cylinder Pipes

  • Lee, Yongjei;Lee, Eun-Taik
    • International Journal of Concrete Structures and Materials
    • /
    • 제7권4호
    • /
    • pp.265-271
    • /
    • 2013
  • Prestressed concrete cylindrical pipe (PCCP) has been widely used for the distribution of water in communal, industrial, and agricultural systems for a long time. However, as it deteriorates, structural failures have been experienced. Replacing the entire existing PCCP with partial damages is not an economical method. Currently, as a cost effective repairing method, a new approach using fiber reinforced polymer (FRP) has been applied. A new design procedure of this method was proposed considering various kinds of loading condition. However, it is not easy to apply this method for design purpose due to its complex procedures. The objective of this study is to provide a new design criteria and process for PCCP rehabilitation with FRP. Through this method, the appropriate quantities of FRP layers will be decided after examining of limit states of deteriorated PCCP. For this purpose, two deterioration conditions are assumed; fully deteriorated and partially deteriorated. Different limit states for each case are applied to decide the quantities of attached FRP. The concept of "margin of safety" is used to judge whether the design results are within the optimal ranges to satisfy all limit states.

개인하수처리시설의 제도개선에 관한 연구 (The System Improvement of the Individual Sewage Treatment System)

  • 장효주;이장훈;강선홍
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.33-40
    • /
    • 2010
  • Individual sewage treatment system is classified into a sewage treatment system which treats all the domestic sewage and a water-purifier tank which treats only effluent flushing from the toilet. The number of registered manufacturers has increased rapidly since 2001. As a result, price competition has increased among the manufacturers and has caused the problems such as the inappropriate production of individual sewage treatment system, the unreasonable permit for building completion and the shortage of the professional technology of the community's public officials in charge. This study collected the problem cases that are related with existing individual sewage treatment system and operation. Efficient improvement plan for the stable supply, installation, maintenance of individual sewage treatment system were suggested.

추진시스템 냉각유로의 주행풍 유동에 대한 수치해석적 연구 (Study on Numerical Analysis for Ram-Air flow of Cooling Duct on the Propulsion System)

  • 유성열;조정래;조태식;김철주
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.507-513
    • /
    • 2009
  • The cooling technology of power conversion semiconductors in the propulsion system for the HEMU(High Electrical Multi Unit) are applied in water cooling method and phase change method such as the immersed type and the heat pipe type. Both of cooling systems need a condenser and a fan through forced wind to emit that is radiated heat from electric power conversion semiconductor(IGBT) stack effectively, now in the case of Japanese Fastec 360S, is using ram-air that is flowed in establishing cooling passage to propulsion system for cooling of condenser. In this research, it is that achieved the computing numerical analysis using ADINA of commertial program to examine flow characteristics and pressure distribution of ram-air for a condenser in cooling passage.

  • PDF

지중 금속구조물 부식감시를 위한 영구매설용 기준전극 개발 (Development of Permanent Reference Electrode for Corrosion Monitoring of Underground Metallic Structures)

  • 하윤철;배정효;하태현;이현구;이재덕;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.532-534
    • /
    • 2004
  • The advancement of electronics and telecommunication technologies has forced the risk management system for underground metallic structures to evolve into the remote monitoring and control system. Especially, facilities such as gas pipelines, oil pipelines and water distribution lines might make hazardous effect on human safety without continuous monitoring and control. As a result, pipeline engineers have applied cathodic protection system to prevent the degradation of their facilities by corrosion and carried out a periodic monitoring of the pipe-to-soil (P/S) potentials at numberous test boxes along their pipelines. The latter action on a road in downtowns, however, is so much dangerous that the inspectors should be ready to suffer the threatening of their lives and maintenance. In order to minimize these social costs and hazards, a stand-alone type corrosion monitoring equipment which can be installed in test box, store the P/S data for given Belied and send the data by wired/wireless telecommunications is under development. In order to obtain the exact P/S data, however, a reference electrode should be located as close to the pipeline as possible. Actually, the measured potential by a conventional portable reference electrode contain inevitably an IR drop portion caused by the current flow from the cathodic protection rectifier or the subway railroad. To minimize this error, it is recommended that the reference electrode should be buried within 10 cm from the pipeline. In this paper, we describe the design parameters for fabricating the permanent type reference electrode and the characteristics of the developed reference electrode.

  • PDF

적외선 열화상 기술을 이용한 원자력 배관의 온도측정과 보정에 관한 연구 (A Study on Measuring the Temperature and Revising the Result When Measuring the Temperature of NPP Pipes Using Infrared Thermography)

  • 김경석;정현철;박찬주;김동수;정덕운;장호섭
    • 비파괴검사학회지
    • /
    • 제29권5호
    • /
    • pp.421-426
    • /
    • 2009
  • 열화상 카메라와 대상물의 측정 위치에 따른 방사각도에 따라 방사율은 달라지게 된다. 이로 인해 열화상 시스템을 이용한 온도 측정시 나타나는 온도 분포는 절대적 온도로 볼 수 없다. 대상체의 실제 표면 온도가 일정하더라도 열화상 카메라로 측정된 온도는 방사율 값에 따라 오차를 가지게 된다. 본 논문에서는 동일 온도로 가열된 원통 형태를 가지는 대상체와 평면 형태를 가지는 대상체의 온도를 열화상 카메라를 이용하여 측정하였다. 측정된 표면 온도값을 통하여 화각에 의한 방사율 보정표와 방사각도의 영향에 의한 반사율 보정식을 구하였으며 이를 바탕으로 측정 온도의 오차보정을 수행하였다. 그리고 방사 각도와 화각에 따른 온도 영향을 원자력 배관의 결함 검출에 적용하여 더욱 신뢰성 있는 표면 온도값을 획득하였다.

국내(國內) 대도시(大都市) 수도관(水道管)의 파손특성(破損特性)에 관한 연구(硏究) (A Study on the Failure Characteristics about Metropolitan Pipelines in Korea)

  • 이현동;안윤주
    • 상하수도학회지
    • /
    • 제10권1호
    • /
    • pp.96-111
    • /
    • 1996
  • The failure of water pipelines is progressed by several compound factors and the collection and analysis of data about pipeline failure are inevitable for effective pipeline rehabilitation. Data analysis of pipeline failure was already performed in USA and Europe. Based on such phenomena, failure characteristics about metropolitan pipelines in Korea were analyzed: The conclusions of this study are as followings. 1. The failure cause of pipelines can be classified into natural cause and artificial cause. Artificial cause is 32% of total causes, so artificial failure as several constructions happens frequently in Korea. Although the failure by old pipe is greatest of any other causes m classtfied cause, failure cause is not classified in detail now. 2. The damaged part of pipelines is affected by cities, distribution system inventory, bedding conditions, and so on. In this study, the failure of pipeline body(67%) is greater than the failure of pipeline joint(33%) in natural failure. 3. In regard to pipe materials, failure rate of DCIP(0.8456), PEP(0.7288), and GSP(0.6643) is greater than that of CIP(0.3985) and CWSP(0.2348). 4. Usually, faIlure rate is increased in proportion to diameter of pipeline. In this study, CIP, DCIP, and CWSP have clear trends. But the trends of PEP is reverse, the case of GSP, HP is obscure due to data shortage. 5. There are no direct relationships between burial age and failure rate of pipelines. 6. Annual breaks and winter(Nov.~Feb.) breaks of pipelines are investigated. As a result, WInter breaks to annual breaks of CIP is 51.3%(Seoul), 51.1%(Taegu),38.7%(Pusan). This phenomena have direct correlation with average winter temp. of cities.

  • PDF

집중변수모델을 이용한 LED조명등 방열기구의 성능분석 (Performance Analysis of Heat Sink for LED Downlight Using Lumped Parameter Model)

  • 김의광;조영철;이승신;안영훈
    • 에너지공학
    • /
    • 제26권2호
    • /
    • pp.64-72
    • /
    • 2017
  • 중동지역 환경에 적합한 70 W급 LED 조명등의 성능분석을 집중변수모델을 이용하여 수행하였다. LED 조명등은 발열기판, 히프파이프, 방열판으로 구성된다. LED 조명등을 4개의 물체로 구분하고, 각각에 대해 에너지평형을 적용하여, 4개의 연립 비선형미분방정식 형태의 집중변수모델을 수립하였다. 연립 방정식의 해는 Runge-Kutta법을 이용하여 구하였다. 집중변수모델의 대류열전달계수는 다차원해석을 통하여 구하였으며, 실험결과와 비교한 결과, 발열기판은 $1.5^{\circ}C$, 상부방열판에서 $1.8^{\circ}C$의 오차를 가지며, 상대오차는 약 0.6 %임을 확인하였다. 이 모델을 이용하여 대기온도가 $55^{\circ}C$인 정상 운전조건, 태양광만 주어질 때의 조건, 태양광이 주어진 상태에서의 비정상 운전조건, 상부방열판이 없는 경우 등에 대한 온도분포분석을 수행하였다.