• Title/Summary/Keyword: Distribution of electrical resistance

검색결과 299건 처리시간 0.026초

컨버터 내장형 LED 가로등 및 보안등의 전기적 특성 분석 (Electrical Characteristics Analysis of LED Lamps using Internal Converter for Road and Street Lighting)

  • 김향곤;길형준;최효상
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.238-244
    • /
    • 2010
  • In this paper, we studied electrical characteristics of internal converter type of LED lamps for road and street lighting. We surveyed electro-technical regulations and KS(Korean industrial standards) about LED luminairs. Waveforms of voltage and current, thermal distributions, insulation resistances between live parts and exposed conductive parts, and flame test of cover of LED lamps were experimented and analyzed. In regulations, insulation resistance between live conductors and exposed conductive parts should be greater than $0.2M{\Omega}$ in case nominal voltage of wiring is 220V. In KS codes, the value of insulation resistance should be greater than $2M{\Omega}$ while applying DC 500V or DC 100V. In the result of this study, waveforms of primary voltage and current were distorted. There was difference in waveforms of secondary voltage and current according to composition of converter. Mostly, insulation resistances were measured high more than regulation and code value but some measured points were measured badly($0.0M{\Omega}$). Cover of LED lamps was ignited easily. We expect that the results of this study would be helpful for revision of regulations and national codes for the electrical safety of LED road and street lighting.

A Study on Electrical and Thermal Properties of Polyimide/MWNT Nanocomposites

  • Park, Soo-Jin;Chae, Sung-Won;Rhee, John-Moon;Kang, Shin-Jae
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권8호
    • /
    • pp.2279-2282
    • /
    • 2010
  • In this work, the electrical and thermal properties of polyimide/multi-walled carbon nanotube (MWNT) nanocomposites were investigated. The polyimide/MWNT nanocomposites contained from 0 to 2.0 wt % of MWNT. The electrical properties of the polyimide films were characterized by a specific resistance measurement. The thermal properties were evaluated using thermogravimetric analysis (TGA) and a differential scanning calorimeter (DSC). It was found that the thermal properties of the polyimide nanocomposites increased with increasing MWNT content and specific resistance as well. This result indicated that the crosslinking of polyimide/MWNT nanocomposites was enhanced by good distribution of the MWNT in the polyimide resins, resulting in the increase of the electrical and thermal properties of the nanocomposites.

Aging Analysis and Reconductoring of Overhead Conductors for Radial Distribution Systems Using Genetic Algorithm

  • Legha, Mahdi Mozaffari;Mohammadi, Mohammad
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2042-2048
    • /
    • 2014
  • In medium voltage electrical distribution networks, reforming the loss reduction is important, and in line with this, the issue of system engineering and use of proper equipment Expansion of distribution systems results in higher system losses and poor voltage regulation. Therefore, an efficient and effective distribution system has become more important. So, proper selection of conductors in the distribution system is crucial as it determines the current density and the resistance of the line. Evaluation of aging conductors for losses and costs imposed in addition to the careful planning of technical and economic networks can be identified in the network design. In this paper the use of imperialist competitive algorithm; genetic algorithm; is proposed to optimal branch conductor selection and reconstruction in radial distribution systems planning. The objective is to minimize the overall cost of annual energy losses and depreciation on the cost of conductors to improve productivity given the maximum current carrying capacity and acceptable voltage levels. Simulations are carried out on 69-bus radial distribution network using genetic algorithm approaches to show the accuracy as well as the efficiency of the proposed solution technique.

지하매설물의 기하학적 특성에 따른 전기저항 변화에 대한 수치 해석 연구 (Numerical Analysis of Electrical Resistance Variation according to Geometry of Underground Structure)

  • 김태영;류희환;정성훈
    • 대한토목학회논문집
    • /
    • 제44권1호
    • /
    • pp.49-62
    • /
    • 2024
  • 급격한 도시화로 인한 지하의 무분별한 개발은 기존 지하매설물의 점검과 교체 그리고 새로운 지하시설물 설치에 지연을 일으키고 있다. 최근에는 체계화된 시스템을 도입하여 지하시설물을 관리하고 있지만, 실제 시공은 현장 여건에 따라서 설계 도면과 다르게 진행되기 때문에 기존 지하매설물의 부정확한 위치 정보로 사고가 끊임없이 발생하고 있다. 한편, 전기비저항 탐사는 전극을 지반에 관입시켜 전극 간 전위차로 지반의 전기저항을 측정하는 방식이며, 비파괴 물리탐사 기법으로서 널리 이용되고 있다. 그리고 다수의 전극 쌍을 이용하여 복잡한 지하 구조를 영상화하고, 딥러닝 알고리즘을 활용한 데이터 해석 기술들이 비약적으로 발전하였지만, 아직 지하매설물의 기하학적 조건에 따른 전기저항 변화를 정량적으로 평가한 기초적인 연구로서는 진행된 바가 없다. 본 연구에서는 전극과 지하매설물의 기하학적 매개 변수 해석을 통해서 전기저항 변화를 평가하였다. 먼저, 이론식과 수치 해석의 전기저항값 차이가 작게 나타난 정량화된 메쉬를 적용하여 3차원 전기저항 수치 해석 모듈을 개발하고, 매설물의 깊이, 크기, 그리고 전극과 매설물 간 이격거리에 따른 매개 변수 해석을 통해서 정상 직류 상태에서 전기저항 변화를 정량적으로 비교하였다. 전기저항은 매설물이 얕은 깊이에 위치하고, 크기가 크고, 전극과의 이격거리가 가까울수록 높게 측정되었다. 추가적으로 전극과 지하매설물 주변에 형성된 전위 및 전류밀도 분포를 분석하여 터미널 전극 주변에서 측정된 전기저항을 고찰하였다.

2회선 배전계통에서 피뢰기 설치방법에 따른 차폐 효과 분석 (Analysis of Shielding Effect with Installation Methods of Arresters in Double Circuits Distribution Systems)

  • 정채균;김상국;이종범;정영호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권2호
    • /
    • pp.104-110
    • /
    • 2004
  • This paper describes the lightning overvoltage occurred differently according to installation methods of arresters and overhead grounding wire in case of double circuits distribution systems. First, the analysis models are established considering the severe case between upper and lower distribution line, when the direct lightning surge strikes to the overhead grounding wire. The lightning overvoltage is variously analyzed with the change of grounding interval and resistance, arrester installation interval as well as the magnitude of surge using EMTP. After simulation results are compared with the BIL which is now used at field, the authors propose the methods for suitable shielding in domestic distribution systems.

신뢰도 지수를 고려한 배전계통의 최적 전력전송경로 결정 (Optimal Routing of Distribution Network Considering Reliability Indices)

  • 신동환;노병권;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권9호
    • /
    • pp.1073-1080
    • /
    • 1999
  • Optimal routing of distribution networks can be attained by keeping the line power capacity limit to handle load requirements, acceptable voltage at customer loads, and the reliability indices such as SAIFI, SAIDI, CAIDI, and ASAI limits. This method is composed of optimal loss reduction and optimal reliability cost reduction. The former is solved relating to the conductor resistance of all alternative routes, and the latter is solved relating to the failure rate and duration of each alternative route. The routing considering optimal loss only and both optimal loss and optimal reliability cost are compared in this paper. The case studies with 10 and 24 bus distribution networks showed that reliability cost should be considered as well as loss reduction to achieve the optimal routing in the distribution networks.

  • PDF

현장시험에 의한 접지전극의 년간 변화 특성 (Characteristics of Seasonal Variations of Ground Electrodes by Field Test)

  • 심건보;김경철;이형수;박재덕;박상만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.500-501
    • /
    • 2006
  • Ground resistance is very important element in distribution line of multi-grounded system. Therefore, use several kind of ground electrode materials to get ground resistance. In this study, examine about characteristics of seasonal variations of ground resistance by several kind of ground electrode material that is used to ground electrode of distribution line, and compares and evaluated characteristics of each ground electrode material.

  • PDF

배전계통 접지전극의 접지효과 분석 연구 (Comparison the grounding effect of a grounding rods and a grounding copper band in the Distribution System)

  • 강문호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.509-511
    • /
    • 2004
  • Grounding rods as a discharge path are normally used to ensure the safety of human beings and facilities from the over-voltages and the over·current. Each grounding mode class 1, class 2, class 3, special class 4- has prescribed ground resistance values which are kept by the utilities. However, in the distribution system, it is very difficult for grounding rods to obtain the prescribed ground resistance values because of the limits of installation space. Therefore, in this paper, the grounding effects of the grounding copper bands which are recently developed to use efficiently in small area and the grounding rods are compared by testing the ground resistance values, ground potential rise(GPR), and step voltage in various cases.

  • PDF

22.9kV-Y 다중접지 배전계통 접지극의 임펄스 응답 특성 실증연구 (A Study On the Impulse Response Behavior of Ground Rods in Power Distribution System)

  • 강문호;장상옥;박상만;하동혁;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1858-1860
    • /
    • 2003
  • Ground rods as the discharge path are commonly installed to ensure the safety of human beings and facilities from the surge. Accordingly, proper grounding resistance are specified by the grounding types, and the specified resistance are also required to install the lightning protective facilities. it is needed to analyze the difference between these two resistance through the field test. Therefore, in this paper, the impulse response behavior of the ground rods is analyzed by constructing the test facilities and by testing the ground rods in multi-ground power distribution systems. The impulse responses were analyzed, in transient state, by testing the concrete poles as well since the grounding wires are installed in the concrete poles.