• Title/Summary/Keyword: Distributed Power Control

Search Result 646, Processing Time 0.027 seconds

Reducing Flooding Latency in Power Save Mode of IEEE 802.11-based Mobile Ad hoc Networks (IEEE 802.11 기반 이동 애드혹 망의 전력 절감 모드에서 플러딩 지연의 개선)

  • 윤현주;서명환;마중수
    • Journal of KIISE:Information Networking
    • /
    • v.31 no.5
    • /
    • pp.532-543
    • /
    • 2004
  • Mobile Ad hoc NETworks (MANET) consist of mobile nodes which are usually powered by battery Approaches for minimizing power consumption have been proposed for all network layers and devices. IEEE 802.11 DCF (Distributed Coordination Function), a well-known medium access control protocol for MANETS, also defines a power save mode operation. The nodes in power save mode periodically repeat the awake state and the doze state in synchronized fashion. When all nodes are in the awake state, the exchange the announcements for the subsequent message transmission with neighbors. The nodes that send or receive the announcements stay awake for data transmission, and others go into the dole state. The previous works for enhancing the power save mode operation have focused on shortening the duration of the awake state. We observed that the longer sleeping period results in seriously long delivery latency and the consequent unnecessary power consumption as well, because the packets can move forward only one hop for a fixed interval. In this paper, we propose an improved protocol for the power save mode of IEEE 802.11 DCF, which allows the flooding packets to be forwarded several hops in a transmission period. Our approach does not reduce the duration of compulsory awake period, but maximizes its utilization. Each node propagates the announcements for next flooding to nodes of several hops away, thus the packets can travel multiple hops during one interval. Simulation results of comparison between our scheme and the standard show a reduction in flooding delay maximum 80%, and the unicasting latency with accompanying flooding flows near 50%, with slight increase of energy consumption.

Mechanical Properties of a High-temperature Superconductor Bearing Rotor in a 10 kWh Class Superconductor Flywheel Energy Storage System (10 kWh급 초전도 베어링 회전자의 기계적 특성 평가)

  • Park, B.J.;Jung, S.Y.;Kim, C.H.;Han, S.C.;Park, B.C.;Han, S.J.;Doo, S.G.;Han, Y.H.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.58-63
    • /
    • 2011
  • Recently, superconductor flywheel energy storage systems (SFESs) have been developed for application to a regenerative power of train, a power quality improvement, the storage of distributed power sources such as solar and wind power, and a load leveling. As the high temperature superconductor (HTS) bearings offer dynamic stability without the use of active control, accurate analysis of the HTS bearing is very important for application to SFESs. Mechanical property of a HTS bearing is the main index for evaluating the capacity of an HTS bearing and is determined by the interaction between the HTS bulks and the permanent magnet (PM) rotor. HTS bearing rotor consists of PM and iron collector and the proper dimension design of them is very important to determine a supporting characteristics. In this study, we have optimized a rotor magnet array, which depends on the limited bulk size and performed various dimension layouts for thickness of the pole pitch and iron collector. HTS bearing rotor was installed into a single axis universal test machine for a stiffness test. A hydraulic pump was used to control the amplitude and frequency of the rotor vibration. As a result, the stiffness result showed a large difference more than 30 % according to the thickness of permanent magnet and iron collector. This is closely related to the bulk stiffness controlled by flux pining area, which is limited by the total bulk dimension. Finally, the optimized HTS bearing rotor was installed into a flywheel system for a dynamic stability test. We discussed the dynamic properties of the superconductor bearing rotor and these results can be used for the optimal design of HTS bearings of the 10kWh SFESs.

Efficient Correlation Channel Modeling for Transform Domain Wyner-Ziv Video Coding (Transform Domain Wyner-Ziv 비디오 부호를 위한 효과적인 상관 채널 모델링)

  • Oh, Ji-Eun;Jung, Chun-Sung;Kim, Dong-Yoon;Park, Hyun-Wook;Ha, Jeong-Seok
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.3
    • /
    • pp.23-31
    • /
    • 2010
  • The increasing demands on low-power, and low-complexity video encoder have been motivating extensive research activities on distributed video coding (DVC) in which the encoder compresses frames without utilizing inter-frame statistical correlation. In DVC encoder, contrary to the conventional video encoder, an error control code compresses the video frames by representing the frames in the form of syndrome bits. In the meantime, the DVC decoder generates side information which is modeled as a noisy version of the original video frames, and a decoder of the error-control code corrects the errors in the side information with the syndrome bits. The noisy observation, i.e., the side information can be understood as the output of a virtual channel corresponding to the orignal video frames, and the conditional probability of the virtual channel model is assumed to follow a Laplacian distribution. Thus, performance improvement of DVC systems depends on performances of the error-control code and the optimal reconstruction step in the DVC decoder. In turn, the performances of two constituent blocks are directly related to a better estimation of the parameter of the correlation channel. In this paper, we propose an algorithm to estimate the parameter of the correlation channel and also a low-complexity version of the proposed algorithm. In particular, the proposed algorithm minimizes squared-error of the Laplacian probability distribution and the empirical observations. Finally, we show that the conventional algorithm can be improved by adopting a confidential window. The proposed algorithm results in PSNR gain up to 1.8 dB and 1.1 dB on Mother and Foreman video sequences, respectively.

Data Acquisition System Applying TMO for GIS Preventive Diagnostic System (GIS 예방진단시스템을 위한 TMO 응용 데이터 수집 시스템)

  • Kim, Tae-Wan;Kim, Yun-Gwan;Jang, Cheon-Hyeon
    • The KIPS Transactions:PartA
    • /
    • v.16A no.6
    • /
    • pp.481-488
    • /
    • 2009
  • GIS is used to isolate large power electrical equipment using SF6 gas. While GIS has simple structure, it has few break down, relatively high reliability. But it is hard to check up faults for reason of pressure. Faults of GIS should have a ripple effect on community and be hard to recovery. Consequently, GIS imports a preventive diagnostic system to find internal faults in advance. It is most important that reliability on the GIS preventive diagnostic system, because it estimates abnormality of system by analysis result of collected data. But, exist system which used central data management is low efficiency, and hard to guarantee timeliness and accuracy of data. To guarantee timeliness and accuracy, the GIS preventive diagnostic system needs accordingly to use a real-time middleware. So, in this paper, to improve reliability of the GIS preventive diagnostic system, we use a middleware based on TMO for guaranteeing timeliness of real-time distributed computing. And we propose an improved GIS preventive diagnostic system applying data acquisition, monitoring and control methods based on the TMO model. The presented system uses the Communication Control Unit(CCU) for distributed data handling which is supported by TMO. CCU can improve performance of the GIS preventive diagnostic system by guaranteeing timeliness of data handling process and increasing reliability of data through the TMO middleware. And, it has designed to take full charge of overload on a data acquisition task had been processed in an exist server. So, it could reduce overload of the server and apply distribution environment from now. Therefore, the proposed system can improve performance and reliability of the GIS preventive diagnostic system and contribute to stable operation of GIS.

Emission Characteristics of Fine Particles, Vanadium and Nickel from Heavy Oil Combustion (중유 연소 시 발생하는 미세입자 및 니켈과 바나듐의 대기 중 배출특성)

  • Jang, Ha-Na;Kim, Sung-Heon;Lee, Ju-Hyung;Hwang, Kyu-Won;Yoo, Jong-Ik;Sok, Chong-Hui;Seo, Yong-Chil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.3
    • /
    • pp.353-360
    • /
    • 2006
  • This study identified a particle size distribution (PSD) of fine particulate matter and emission characteristics of V and Ni by the comparison between anthropogenic sources of oil combustion (industrial boiler, oil power plant, etc.) and lab-scale combustion using a drop-tube furnace. In oil combustion source, the mass fraction of fine particles (less than 2.5 micrometers in diameter) was higher than that of coarse particles (larger than 2.5 micrometers in diameter) in $PM_{10}$ (less than 10 micrometers in diameter) as like in lab-scale oil combustion. In addition to this, it was identified that ultra-fine particles (less than 0.1 micrometers in diameter) had a large distribution in fine particles. Toxic metals like V and Ni had large mass fractions in fine particles, and most of all was distributed in ultra-fine particles. Most of ultra-fine particles containing toxic metals have been emitted into ambient by combustion source because it is hard to control by the existing air pollution control device. Hence, we must be careful on these pollutants because it is obvious that these are associated with adverse health and environmental effect.

Gyeongnam Inhabitants' Effects of COVID-19 Infection Prevention Behavior: Focus on Anxiety and Health Belief (경남도민의 COVID-19 감염예방행위에 미치는 영향요인: 불안, 건강신념을 중심으로)

  • Kim, Sun Joo;Kim, Eun Young;Yang, Hye Ryun;Chae, Yeo Joo
    • Journal of Korean Public Health Nursing
    • /
    • v.35 no.1
    • /
    • pp.19-32
    • /
    • 2021
  • Purpose: This study was aimed to identify the influencing factors on the COVID-19 infection prevention behavior of adults residing in Gyeongsangnam-do by examining relationships between anxiety, health belief and COVID-19 infection prevention behavior. Methods: The participants of this study were recruited from a website, and the total number of participants was 186. The self-report questionnaires were distributed during July 2020. Results: Multiple regression analysis revealed the significant factors affecting the COVID-19 infection prevention behavior of adult residing in Gyeongsangnam-do were perceived barriers(��=-3.68, p<.001), perceived benefits(��=3.39, p=.001), perceived susceptibility(��=2.83, p=.005), sex(��=2.59, p=.010). The total explanatory power of the study variables for COVID-19 infection prevention behavior was 35.0%(F=17.61, p<.001). Conclusions: Based on these findings, in order to promote COVID-19 infection prevention behavior, there is needed to reduce obstacles for carrying out infection prevention behaviors, and develop multi-faceted promotional strategies for infection prevention behaviors.

Autonomous Control for AC Microgrid Connected with Distributed Generation and Energy Storage System (분산전원 및 ESS가 연계된 AC 마이크로그리드의 자율적 제어기법)

  • Jang, Myeong-Jun;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.451-452
    • /
    • 2016
  • 최근 풍력 및 태양광 발전과 같은 분산전원 시스템의 설비가 증가함에 따라 전력 생산자가 늘어나고 있으며 발전량이 불규칙적인 신재생에너지 자원을 전력 수요에 따라 효율적으로 운용하고 관리하기 위한 에너지 저장장치(Energy storage system : ESS)의 필요성이 증가하고 있다. 최근에는 기존의 중앙집중 방식의 전력 시스템이 가지는 여러 문제를 해결하기 위해 여러 분산 발전 요소들과 에너지 저장장치, 부하 및 계통을 상호 연결한 마이크로그리드의 개념이 제안되고 있다. 마이크로그리드 내에서 분산전원과 계통에 ESS가 연계 되면 전력수급 상황에 따라 잉여전력이 발생할 때 전력을 저장할 수 있으며 전력수요가 클 때 저장된 전력을 부하에 공급하여 전력설비를 보다 안정적이고 효율적으로 운용할 수 있다. 본 논문에서는 풍력발전 시스템, 양방향 충/방전이 가능한 ESS, 부하 및 계통이 연계된 마이크로그리드를 대상으로 이를 효율적으로 운용하고 계통전력 사용을 최소화 할 수 있는 독립형 마이크로그리드의 자율적 제어기법에 대한 연구를 수행한다. 전력수급 상황에 따라 각 요소들의 운전 모드를 결정하는 기법이 제시되고 각 동작 모드에서의 분석 및 시뮬레이션에 의한 검증을 통하여 본 제어기법의 효용성을 입증한다.

  • PDF

Impedance Characteristics of an Expansion-Resonator Type Pulsation Attenuator(Attenuation on Flow and Pressure Ripple form a Hydraulic Piston Pump) (팽창 공명기형 맥동 감쇠기의 임피던스 특성(유압용 피스톤 펌프의 유량.압력맥동 감쇠))

  • 이상기
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.1
    • /
    • pp.88-95
    • /
    • 2000
  • In this paper, an expansion-resonator type pulsation attenuator is proposed to absorb and attenuate flow an pressure ripple with high frequencies generated from hydraulic control systems. The basic principle of a pulsation attenuator proposed here is applied to propagation, reflection, absorption of pressure waves at the cross section of discontinuity and resonance in the pipeline. It has advantage of the compact size and high degree fo freedom for installation in hydraulic systems. The design scheme based on distributed parameter pipeline system with dissipative viscous compressible model is developed. To investigate the reduction of flow and pressure ripple with high frequencies produced by swash plate type axial piston pump, two kinds of attenuators are manufactured. It is experimently confirmed that the spectral intensity of flow and pressure ripple with high frequencies from the pump are reduced up to about 20$^{\circ}$~30dB by using attenuators proposed here. The calculated results were in good agreement with the measured values. From there sults of this study, it is shown that an expansion-resonator type pulsation attenuator is effective in a wide frequency ranges to attenuate the flow and pressure ripple from hydraulic components.

  • PDF

Development of Wireless Base Station Re4mote Monitoring System Using IoT Based on Cloud Server (클라우드 서버 기반 IoT를 이용한 무선기지국 원격 감시시스템 개발)

  • Lee, Yang-Weon;Kim, Chul-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.491-494
    • /
    • 2018
  • Radio base stations, which are widely distributed across large areas, have many difficulties in managing them. Unmanned radio base stations in remote mountains are having a hard time accessing them in case of emergencies. Major telephone service providers only remotely control incoming and outgoing information and local small business partners responsible for maintaining actual facilities do not possess such technologies, so they are each checked during field visits. In this study, in order to monitor temperature, humidity, fire condition, and power operation at a wide range of radio base stations, real-time monitoring is carried out at the office of Klaus server through real-time monitoring.

  • PDF

A Detection Method of Grid Voltage for Grid Support Operation of an Inverter-based Renewable Energy Generation System (인버터 기반 신재생 에너지 발전 시스템의 계통 지원 운전을 위한 계통 전압 검출 방법)

  • Ahn, Hyun-Chul;Song, Seung-Ho
    • New & Renewable Energy
    • /
    • v.9 no.2
    • /
    • pp.51-57
    • /
    • 2013
  • The Grid code is being strengthen as increase of renewable energy ratio. Especially, the grid connection regulations are continuously being updated for stable operation of power grids. Static grid support and Dynamic grid support must make an accurate measure at Grid connected point because they needs control algorithm individually. It has to exactly measure voltage including switching ripple at the output of the inverter generating system. In addition, it is necessary to have an accurate voltage measurement when the situation rapidly changing the grid impedance is caused by the input of serial impedance of transformer and line impedance as well as Grid Fault Device. In this paper, We propose a new detection method of grid voltage to calculate accurately the r.m.s voltage of the grid connection point along the standard required by the low voltage regulation. We verified performance through simulation grid fault device.