• 제목/요약/키워드: Distributed Generators

검색결과 134건 처리시간 0.023초

규제가 없는 전력계통에서 대체분산전원으로서의 연료전지 (Fuel Cell as an Alternative Distributed Generation Source under Deregulated Power Systems)

  • 이광연;김세호;김일환;김호찬
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.561-569
    • /
    • 2006
  • Because of the trend of deregulation, power industry is going through an unprecedented transformation in North America and Europe, and there are a host of acquisitions and mergers by the private sector to position themselves to take advantage of new business opportunities. Deregulation has accelerated the development of smaller generators and fuel cells will gradually become more attractive to mainstream electricity users as they improve in capability and decrease in cost. Fuel Cell technology is surveyed and the potential of using fuel cell as a distributed generation source is presented. This paper recommends the fuel cell power plants as alternative energy sources for distributed generation in Jeju Island, Korea. This will help in increasing fuel efficiency, at least double the current thermal plants', increasing the reliability of power supply, reducing the dependency on the HVDC link, providing quality power to the growing infrastructure, and maintaining clean air in meeting the free-trade international island.

멀티에이전트 시스템을 이용한 마이크로그리드 분산 지능형 관리시스템 파일럿 플랜트 개발 (Development of Pilot Plant for Distributed Intelligent Management System of Microgrids)

  • 오상진;유철희;정일엽;임재봉
    • 전기학회논문지
    • /
    • 제62권3호
    • /
    • pp.322-331
    • /
    • 2013
  • This paper describes the development of the pilot plant of distributed intelligent management system for a microgrid. For optimal control and management of microgrids, intelligent agents area applied to the microgrid management system. Each agent includes intelligent algorithms to make decisions on behalf of the corresponding microgrid entity such as distributed generators, local loads, and so on. To this end, each agent has its own resources to evaluate the system conditions by collecting local information and also communicating with other agents. This paper presents key features of the data communication and management of the developed pilot plant such as the construction of mesh network using local wireless communication techniques, the autonomous agent coordination schemes using plug-and-play functions of agents and contract net protocol (CNP) for decision-making. The performance of the pilot plant and developed algorithms are verified via real-time microgrid test bench based on hardware-in-the-loop simulation systems.

Intelligent Coordination Method of Multiple Distributed Resources for Harmonic Current Compensation in a Microgrid

  • Kang, Hyun-Koo;Yoo, Choel-Hee;Chung, Il-Yop;Won, Dong-Jun;Moon, Seung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.834-844
    • /
    • 2012
  • Nonlinear electronic loads draw harmonic currents from the power grids that can cause energy loss, miss-operation of power equipment, and other serious problems in the power grids. This paper proposes a harmonic compensation method using multiple distributed resources (DRs) such as small distributed generators (DGs) and battery energy storage systems (BESSs) that are integrated to the power grids through power inverters. For harmonic compensation, DRs should inject additional apparent power to the grids so that certain DRs, especially operated in proximity to their rated power, may possibly reach their maximum current limits. Therefore, intelligent coordination methods of multiple DRs are required for efficient harmonic current compensation considering the power margins of DRs, energy cost, and the battery state-of-charge. The proposed method is based on fuzzy multi-objective optimization so that DRs can cooperate with other DRs to eliminate harmonic currents with optimizing mutually conflicting multi-objectives.

Identification and Damping of Resonances in Inverter-based Microgrids

  • Afrasiabi, Morteza;Rokrok, Esmaeel
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1235-1244
    • /
    • 2018
  • The application of shunt capacitor banks and underground cables typically induces resonance in power distribution systems. In this study, the propagation of resonance in a microgrid (MG) with inverter-based distributed generators (IBDGs) is investigated. If resonances are not properly damped, then the output current of the inverters may experience distortion via resonance propagation due to the adverse effect of resonances on MG power quality. This study presents a conceptual method for identifying resonances and related issues in multi-inverter systems. For this purpose, existing resonances are identified using modal impedance analysis. However, some resonances may be undetectable when this method is used. Thus, the resonances are investigated using the proposed method based on the frequency response of a closed-loop MG equivalent circuit. After analyzing resonance propagation in the MG, an effective virtual impedance damping method is used in the IBDG control system to damp the resonances. Results demonstrate the effectiveness of the proposed method in compensating for existing resonances.

Analytical and sensitivity approaches for the sizing and placement of single DG in radial system

  • Bindumol, E.K.;Babu, C.A.
    • Advances in Energy Research
    • /
    • 제4권2호
    • /
    • pp.163-176
    • /
    • 2016
  • Rapid depletion of fossil based oil, coal and gas reserves and its greater demand day by day necessitates the search for other alternatives. Severe environmental impacts caused by the fossil fire based power plants and the escalating fuel costs are the major challenges faced by the electricity supply industry. Integration of Distributed Generators (DG) especially, wind and solar systems to the grid has been steadily increasing due to the concern of clean environment. This paper focuses on a new simple and fast load flow algorithm named Backward Forward Sweep Algorithm (BFSA) for finding the voltage profile and power losses with the integration of various sizes of DG at different locations. Genetic Algorithm (GA) based BFSA is adopted in finding the optimal location and sizing of DG to attain an improved voltage profile and considerable reduced power loss. Simulation results show that the proposed algorithm is more efficient in finding the optimal location and sizing of DG in 15-bus radial distribution system (RDS).The authenticity of the placement of optimized DG is assured with other DG placement techniques.

분산전원의 Anti-islanding용 수정된 zero-crossing 방식 주파수 검출기법 (A frequency measurement based on modified zero-crossing method for anti-islanding detection of distributed generation)

  • 배병열;백승택;이진희;서인영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.634-636
    • /
    • 2008
  • This paper proposes a frequency detection method based on an advanced zero-crossing technique. Zero-crossing method for detecting frequency is one of the most widely used methods today. Although it is simple to apply, it requires extra hardware in implementation due to its limitations in accuracy. The proposed method models the error generated during zero crossing linearization and compensated for it in real time which makes it simple and accurate. The validity of the method and its applicability in anti-islanding detection of distributed generators was confirmed through simulation.

  • PDF

원자력발전소 증기발생기 수위제어를 위한 퍼지제어기법의 현장 제어기계에의 적용 (Implementation of Fuzzy Control Algorithm For Nuclear Power Plant Steam Generator Level Control At Field Controller)

  • 박기용;허우성;성풍현
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.111-121
    • /
    • 1995
  • A fuzzy control algorithm of bell-type membership functions and 9 rules is constructed for narrow range level control of steam generators in nuclear power plants. It is implemented at a field digital distributed controller, a Westinghouse-made controller called Westinghouse Distributed Processing Family(WDPF). Performance for level control of the developed fuzzy controller is compared with that of conventional controller, both at the field controller. For these comparisons, both the fuzzy control algorithm and the conventional PI control algorithm were carefully tuned. Also the sampling time for optimal performance was investigated. The results show that the fuzzy control algorithm is not only better in performance than the conventional algorithm but also much easier to be tuned by operators in the field.

배전선 보호기기 선정 시 계통 연계 분산전원의 용량 고려 (Consideration of the Distributed Generator's Capacity in Determining the Protective Devices)

  • 박인기;장성일;박용업;김세근;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.331-333
    • /
    • 2003
  • This paper describes the effect of the interconnected wind turbine generators on fault current level of distribution networks. Distributed generator(DG) interconnected with grid can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the distribution power line with DG, the fault current level measured in a relaying point might be higher than that of distribution network without wind turbine generator due to the contribution of wind farm. Consequently, it may destroy the conventional protective devices applied in the distribution network with DG. Simulation results shows that the current level of fault happened in the power line with DG depends on the power output of DG.

  • PDF

분산전원 연계 배전계통의 보호협조 정정 프로그램 개발 (A Simulation Program for Protection Coordination in the Power Distribution System with Distributed Generators)

  • 김상옥;서인용;이흥호;노대석
    • 한국시뮬레이션학회논문지
    • /
    • 제22권1호
    • /
    • pp.1-8
    • /
    • 2013
  • 신재생에너지원의 확대 보급 정책과 신재생에너지 공급 의무화 제도(RPS)의 도입으로 배전계통에 연계되는 분산전원이 증가되고 있다. 분산전원이 연계된 배전계통에서는 고장전류의 크기와 방향이 변화하게 되며, 이러한 고장전류의 변화는 기존 보호협조 체계에 대한 재검토를 요구한다. 전력연구원에서는 이러한 고장전류의 변화를 고려할 수 있는 보호협조 정정 알고리즘을 탑재한 시뮬레이션 프로그램을 개발하였다. 본 논문에서는 분산전원 연계 전, 후의 고장전류 변화를 분석하고, 시뮬레이션 프로그램을 이용하여 샘플 계통에 대한 보호협조 정정을 수행하였으며, 분산전원이 배전계통의 보호협조에 미치는 영향에 대하여 고찰하고 그 대책에 대하여 논하고자 한다.

A Novel Three-Phase Four-Wire Grid-Connected Synchronverter that Mimics Synchronous Generators

  • Tan, Qian;Lv, Zhipeng;Xu, Bei;Jiang, Wenqian;Ai, Xin;Zhong, Qingchang
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2221-2230
    • /
    • 2016
  • Voltage and frequency stability issues occur in existing centralized power system due to the high penetration of renewable energy sources, which decrease grid absorptive capacity of them. The grid-connected inverter that mimics synchronous generator characteristics with inertia characteristic is beneficial to electric power system stability. This paper proposed a novel three-phase four-wire grid-connected inverter with an independent neutral line module that mimics synchronous generators. A mathematical model of the synchronous generator and operation principles of the synchronverter are introduced. The main circuit and control parameters design procedures are also provided in detail. A 10 kW prototype is built and tested for further verification. The primary frequency modulation and primary voltage regulation characteristics of the synchronous generator are emulated and automatically adjusted by the proposed circuit, which helps to supports the grid.