• Title/Summary/Keyword: Distance protection

Search Result 525, Processing Time 0.027 seconds

The Selter Selection Plan due to Formaldehyde Leakage (산화프로필렌의 누출영향평가에 따른 안전거리 산정)

  • Seongju Oh;Sanghun Han;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.11-22
    • /
    • 2024
  • This study aims to present safety distances by the damage impact assessment of the leakage of propylene oxide. As a result of the experiment, the pressure 1psi range was 52m to 169m, the radiant heat 18kW/m2 range was 63m to 163m, the AEGL-2 range was analyzed as 224m to 414m, and the fire ball diameter was analyzed to be 45m to 121m. Additionally, the extent of damages was proportional to the amount of propylene oxide stored or handled. The safe distance for a 10% lethality due to overpressure and radiant heat was calculated to be 134m, and the safe distance for a 0% lethality was 169m. Toxicity was measured at 134m with a lethality 0%. Therefore, the safety distance due to leakage of propylene oxide is calculated to be between 134m and 169m.

Genetic Diversity and Morphological Variations of Goosegrass [Eleusine indica (L.) Gaertn] Ecotypes in Malaysia

  • Saidi, Nazreen;Kadir, Jugah;Hong, Lau Wei
    • Weed & Turfgrass Science
    • /
    • v.5 no.3
    • /
    • pp.144-154
    • /
    • 2016
  • Goosegrass [Eleusine indica (L.) Gaertn] has been a nuisance to growers in Malaysia due to its increased resistance to commercial herbicides, rapid growth and dissemination, and interference with agricultural practices. In the course of developing an apt integrated management to control goosegrass, more information of this weed is needed. The aim of this study was to look into variations among the goosegrass ecotypes sampled throughout Malaysia from the aspects of genotype and phenotype. Sequence-related amplified polymorphism (SRAP) markers were employed in investigating the genetic diversity and relationships among the 18 goosegrass ecotypes. Consequently, 5 primer combinations amplified 13 fragments with the polymorphism rate of 69.23%. At 74% similarity, the ecotypes were clustered into 6 groups. Phenotypic variability of the goosegrass ecotypes was assessed by observing their morphology, growth and seed traits. Goosegrass ecotypes were sorted into 3 major groups at the genetic distance (DIST) of 0.37. Concurrences of the evaluated genetic distance, ecotypes with the closest and most distant relationships were assembled together in Group I which showed high variation even among ecotypes in the same group. Results obtained thus implied high molecular and morphological variations of the goosegrass ecotypes in Malaysia.

Fire Extinguishing Capability of an Automatic Spreading Fire Extinguisher in Accordance with Horizontal Distance from a Fire Source (자동확산소화장치의 이격거리에 따른 소화성능평가연구)

  • Kwark, Ji-Hyun;Kim, Dong-Suk;Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.38-43
    • /
    • 2013
  • An automatic spreading fire extinguisher usually installed in a closed area like a boiler room, a laundry store or a restaurant's kitchen room is one of the fire protection equipments. This extinguisher automatically discharges dry powder, extinguishing fire. As this extinguisher has the extinguishing capability applicable to the nominal protection area, objects outside the area cannot be properly extinguished. However only its number is being requested according to the floor area in the related laws, and the extinguishing capability depends on the distance from a fire source. In this study we tried to investigate the extinguishing capability of the automatic spreading fire extinguisher in accordance with horizontal separation distance from a fire source. It appeared that the maximum horizontal separation distance was about 30 cm for both class A and B fire to be certainly extinguished.

Examination History and Abnormal Thyroid and Breast Lesions According to Residential Distance from Nuclear Power Plants

  • Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.402-408
    • /
    • 2016
  • Background: Ascertainment bias are common in epidemiologic studies to assess the association between thyroid cancer risk and living near nuclear power plants because many thyroid cancers are diagnosed by chance through health examination. We surveyed the ultra sonography (USG) examination history and conducted thyroid and breast USG in residents living near nuclear power plants. Materials and Methods: The study population comprised 2,421 residents living near nuclear power plants in Korea. Information on demographic characteristics, including diagnostic examination history, was collected by interview using questionnaires. USG examination was conducted to evaluate the presence of thyroid nodules and breast lesion. Study participants were divided into 3 groups according to the distance of their respective villages from a nuclear power plant. The proportions of USG examination history and prevalence of thyroid nodules and breast lesions were compared between groups. Results and Discussion: Examination histories of thyroid USG were 23.1%, 13.7%, and 10.5% in men and 31.3%, 26.7%, 18.3% in women in the short, intermediate, and long distance groups, respectively. There were significant inverse associations between thyroid USG history and the distance from nuclear power plants (P for trend = 0.001 for men and 0.017 for women). However, there was no association between the distance of villages from nuclear power plants and prevalence of thyroid nodules. Conclusion: Our results suggest that there may be an ascertainment bias in population-based studies examining the harmful effects of NPPs examination and researchers should pay attention to ascertainment bias resulted from differential health examination. Correction for ascertainment bias, active follow-up and examination for all study population to remove differential health examination is needed.

Performance Evaluation of Radiation Protection Apron's (방사선방어 앞치마 성능 평가)

  • Kang, Jong-gu;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.373-377
    • /
    • 2019
  • Radiation exposure is on the rise as the working hours of radiation workers increase. Accordingly, the importance of protection products for decreasing the dose of exposure has risen, and excellent X-ray shielding ability and light weight are required. The purpose of this study is to compare the Pb which use currently and other elements in order to reduce the exposure of workers to the most effective protection products. For experiment, we used the general X-ray equipment and angiography equipment, and obtained the Pb and apron's shielding rate. When the shielding rate of Pb and apron was compared in general X-ray equipment, the shielding rate was 95.1% for Pb 0.5 mm, 96.1% for apron 0.5 mmPb and 95.6% for Bi+W 0.5 mmPb. When compared the shielding rate of each aprons in angiography equipment, 0.5 mmPb apron was the highest as 96.4% and Bi+W 0.25 mmPb apron was the lowest as 90.2% at the 50 cm distance. The shielding rate of 0.5 mmPb apron was the highest as 95.7% and Bi+W 0.25 mmPb apron was the lowest as 85.9% at the 100 cm distance. As a result of evaluating the apron efficiency through this study, 0.5 mmPb apron showed the best shielding rate, but it was the heaviest apron. 0.35 mmPb apron and Bi+W 0.25 mmPb apron weighed light but had low shielding rate. Through the results of this experiment, it is recommended that radiation workers reduce radiation exposure by using more efficient protection products.

A Study on Distance Relay of Transmission UPFC Using Artificial Neural Network (신경회로망을 이용한 UPFC가 연계된 송전선로의 거리계전기에 관한 연구)

  • Lee, Jun-Kyong;Park, Jeong-Ho;Lee, Seung-Hyuk;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.37-44
    • /
    • 2004
  • This paper represents a new approach for the protective relay of power transmission lines using a Artificial Neural Network(ANN). A different fault m transmission lines need to be detected classified and located accurately and cleared as fast as possible. However, The protection range of the distance relay is always designed on the basis of fixed settings, and unfortunately these approach do not have the ability to adapt dynamically to the system operating condition. ANN is suitable for the adaptive relaying and the detection of complex faults. The backpropagation algerian based multi-layer protection is utilized for the teaming process. It allows to make control to various protection functions. As expected, the simulation result demonstrate that this approach is useful and satisfactory.

MLP-A(Multi Link Protection for Airborne Network Verifying) algorithms and implementation in multiple air mobile/verification links (다중 공중 이동/검증 링크에서의 MLP-A 알고리즘 및 구현)

  • Youn, Jong-Taek;Jeong, Hyung-jin;Kim, Yongi;Jeon, Joon-Seok;Park, Juman;Joo, Taehwan;Go, Minsun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.3
    • /
    • pp.422-429
    • /
    • 2022
  • In this paper, the intermediate frequency transmission signal level between the network system-based baseband and RF unit consisting of multi-channel airborne relay devices and a lot of mission devices, which are currently undergoing technology development tasks, is kept constant at the reference signal level. Considering the other party's receiving input range, despite changes in the short-range long-range wireless communication environment, it presents a multi-link protection and MLP-A algorithm that allows signals to be transmitted stably and reliably through signal detection automatic gain control, and experiments and analysis considering short-distance and long-distance wireless environments were performed by designing, manufacturing, and implementing RF units to which MLP-A algorithms were applied, and applying distance calculation equations to the configuration of multiple air movements and verification networks. Through this, it was confirmed that a stable and reliable RF communication system can be operated.

Analysis of the response of a distance relay considering the errors of CT and CCVT (CT와 CCVT의 오차를 고려한 거리 계전기의 응동 분석)

  • Kang, Yong-Cheol;Zhang, Tai-Ying;Choi, Jae-Sun;Kang, Hae-Gweon;Kim, Kwang-Moo;Jang, Sung-Il;Kim, Yong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.12-15
    • /
    • 2008
  • A distance relay has been widely used for transmission line protection. The distance relay detects a fault based on the calculated impedance i.e. the ratio of the voltage to the current measured from a current transformer (CT) and a coupling capacitor voltage transformer (CCVT), respectively. When a fault occurs and a CT saturates due to the magnitude of fault current, dc component, primary time constant, and the remanent flux of the iron core, the secondary current of a CT is distorted On the other hand, non-fundamental components generated during a fault can increase the error of a CCVT, particularly when a fault distance is short. The distortion of the current and voltage can cause mal-operation or the operating time delay of a distance relay. This paper describes the response of a distance relay considering the errors of a CT and a CCVT. The results indicate that the severe distortion of a CT and a CCVT have noticeable effect to a distance relay.

  • PDF

The Analysis of Protection Ratio and Its Effect of Interference-to-Noise Ratio for Digital Microwave System with Diversity

  • Suh Kyoung-Whoan;Jang Won-Gyu
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.3
    • /
    • pp.189-195
    • /
    • 2006
  • In this paper, the derivation of the protection ratio for the digital microwave system with diversity is newly suggested for a basic guidance of initial planning for frequency coordination, and computational results are presented for an actual radio frequency band. The net filter discrimination has been also examined to see the effect of the adjacent channel protection ratio caused by adjacent channel interference. In addition, the protection ratios for the space or frequency diversity system are analyzed in terms of diversity improvement factors to find out an equivalent allowable noise-to-interference ratio (N/I) from degraded fade margin. According to results for 6.2 GHz system, with the space diversity of 25 m distance between antennas or the frequency diversity of ${\Delta}f/f=0.05$, under 64-QAM and 60 km at BER $10^{-6}$, the protection ratio can be greatly reduced in comparison to the non-diversity system. So, assuming that only the same protection ratio as the non-diversity system is kept, it is shown that the system with diversity may get more interference level of N/I allowing from 9.0 to - 5.9 dB or from 6.0 to - 4.3 dB for the space or frequency diversity. In consequence, it is concluded that the diversity system is more robust or tolerable for interferences or fades, which may play an important role in overcoming N/I to some extent.