• 제목/요약/키워드: Distance measurement system

검색결과 962건 처리시간 0.033초

뇌방전의 리더진전에 따른 전장파형의 측정과 분석 (Measurement and Analysis for Electric Fields due to Lightning stepped leaders)

  • 이복희;정광희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2164-2166
    • /
    • 1999
  • This paper is describes the measured electric field waveform radiated by lightning discharge. We have performed measurement and analysis of the electric fields associated with stepped leaders. Electric field measurement system was composed of hemisphere electric field sensor, measurement system of a distance from lightning strokes, automatical recording system, A/D board, personal computer etc. A/D board have high sampling time, high speed data processing, 8bit of resolution. Also, measured characteristics of stepped leaders radiated by were analyzed.

  • PDF

극한환경 원격조작을 위한 거리측정시스템 개발 (A noncontact distance and dimension measurement system for remote handling in hostile environment)

  • 정우태;이재설;박현수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.602-607
    • /
    • 1990
  • Spent nuclear fuel is very dangerous substance emitting strong ionizing radiation which is harmful to human body. The remote handling of spent nuclear fuel is essential because people cannot access this substance without protecting radiation. To handle highly radioactive material or nuclear waste, many kinds of teleoperators such as master slave manipulator, electro mechanical manipulator, servo manipulator, mobile robot was developed. The distance and dimension of target object cannot be measured easily when highly radioactive material is handled by teleoperator because one should use lead glass or TV camera and monitor to protect radiation and see target object. During experiments on the remote handling of spent nuclear fuel by electro mechanical manipulator, we often felt that a distance and dimension measurement system is necessary to handle the objects which is in the highly radioactive environment, so we developed a system which is appropriate for this purpose.

  • PDF

진폭 변조 거리 측정 시스템에 적용 가능한 개선된 위상 추정 기법 (An Improved Phase Estimation Method for AM Range Measurement System)

  • 김대중;오택환;황선영
    • 한국통신학회논문지
    • /
    • 제37권6C호
    • /
    • pp.453-461
    • /
    • 2012
  • 본 논문에서는 진폭 변조 거리 측정 시스템에 적용 가능한 개선된 위상 추정 기법을 제안한다. 기존 위상 측정 방법은 이동 목표물의 도플러 천이에 의해 위상 측정 오차가 발생한다. 제안된 위상 추정 기법은 도플러 천이에 대해 적응 도플러 보정(Adaptive Doppler Correction)을 사용하여 위상 추정 오차를 보정하므로 거리 측정 정확도를 향상 시킬 수 있다. 모의실험 결과 도플러 주파수 천이 보정은 기존 방식보다 94.7% 향상된 성능을 보이며, 거리 측정 정확도는 50%로 향상되었다. 음향 수조에서는 오차가 7.7cm로 추정되어 해양 환경에서 음파를 이용하여 거리 추정에도 적용 가능함을 확인하였다.

로봇의 시각시스템을 위한 물체의 거리 및 크기측정 알고리즘 개발 (Development of a Robot's Visual System for Measuring Distance and Width of Object Algorism)

  • 김회인;김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제17권2호
    • /
    • pp.88-92
    • /
    • 2011
  • This paper looks at the development of the visual system of robots, and the development of image processing algorism to measure the size of an object and the distance from robot to an object for the visual system. Robots usually get the visual systems with a camera for measuring the size of an object and the distance to an object. The visual systems are accurately impossible the size and distance in case of that the locations of the systems is changed and the objects are not on the ground. Thus, in this paper, we developed robot's visual system to measure the size of an object and the distance to an object using two cameras and two-degree robot mechanism. And, we developed the image processing algorism to measure the size of an object and the distance from robot to an object for the visual system, and finally, carried out the characteristics test of the developed visual system. As a result, it is thought that the developed system could accurately measure the size of an object and the distance to an object.

Enhancement of Tracking Performance of Laser Tracking System for Measuring Position Accuracy of Robots

  • Hwang, Sung-Ho;Choi, Gyeong-Rak;Lee, Ho-Gil;Shon, Woong-Hee;Kim, Jin-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.61.5-61
    • /
    • 2001
  • The laser tracking system(LTS) presents the most promising technique for dynamic position measurement of industrial robots. This system combine the advantage of high accuracy with a contactless measurement technique. It is the measurement system of position in three dimensions using distance data obtained by laser interferometer and real time angle by tracking mirror assembly. After measuring the tracking error of the beam projected on the center of retroreflector in robot end effector, this system tracks the end effector continuously by adjusting tracking mirror angle to minimize this error ...

  • PDF

Calibration of the depth measurement system with a laser pointer, a camera and a plain mirror

  • Kim, Hyong-Suk;Lin, Chun-Shin;Gim, Seong-Chan;Chae, Hee-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1994-1998
    • /
    • 2005
  • Characteristic analysis of the depth measurement system with a laser, a camera and a rotating mirror has been done and the parameter calibration technique for it has been proposed. In the proposed depth measurement system, the laser beam is reflected to the object by the rotating mirror and again the position of the laser beam is observed through the same mirror by the camera. The depth of the object pointed by the laser beam is computed depending on the pixel position on the CCD. There involved several number of internal and external parameters such as inter-pixel distance, focal length, position and orientation of the system components in the depth measurement error. In this paper, it is shown through the error sensitivity analysis of the parameters that the most important parameters in the sense of error sources are the angle of the laser beam and the inter pixel distance. The calibration techniques to minimize the effect of such major parameters are proposed.

  • PDF

실거리 파라미터 교정식 복합센서 기반 3차원 거리측정 시스템 (3D Depth Measurement System based on Parameter Calibration of the Mu1ti-Sensors)

  • 김종만;김원섭;황종선;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 영호남 합동 학술대회 및 춘계학술대회 논문집 센서 박막 기술교육
    • /
    • pp.125-129
    • /
    • 2006
  • The analysis of the depth measurement system with multi-sensors (laser, camera, mirror) has been done and the parameter calibration technique has been proposed. In the proposed depth measurement system, the laser beam is reflected to the object by the rotating mirror and again the position of the laser beam is observed through the same mirror by the camera. The depth of the object pointed by the laser beam is computed depending on the pixel position on the CCD. There involved several number of internal and external parameters such as inter-pixel distance, focal length, position and orientation of the system components in the depth measurement error. In this paper, it is shown through the error sensitivity analysis of the parameters that the most important parameters in the sense of error sources are the angle of the laser beam and the inter pixel distance.

  • PDF

수동 센서의 오차 최소화를 이용한 실시간 DSC 자동초점 시스템 설계 (A Design of Real-time Automatic Focusing System for Digital Still Camera Using the Passive Sensor Error Minimization)

  • 김근섭;김덕영;김성환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권5호
    • /
    • pp.203-211
    • /
    • 2002
  • In this paper, the implementation of a new AF(Automatic Focusing) system for a digital still camera is introduced. The proposed system operates in real-time while adjusting focus after the measurement of distance to an object using a passive sensor, which is different from a typical method. In audition, measurement errors were minimized by using the data acquired empirically, and the optimal measuring time was obtained using EV(Exposure Value) which is calculated from CCD luminance signal. Moreover, this system adopted an auxiliary light source for focusing in absolute dark conditions, which is very hard for CCD image Processing. Since this is an open-loop system adjusting focus immediately after the distance measurement, it guarantees real-time operation. The performance of this new AF system was verified by comparing the focusing value curve obtained from AF experiment with the one from the measurement by MF(Manual-Focusing). In both case, edge detector was used for various objects and backgrounds.

전기용량성 섬유 압력센서를 이용한 호흡측정 시스템 (Respiration Measurement System using Textile Capacitive Pressure Sensor)

  • 민세동;윤용현;이충근;신항식;조하경;황선철;이명호
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.58-63
    • /
    • 2010
  • In this paper, we proposed a wearable respiration measurement system with textile capacitive pressure sensor. Belt typed textile capacitive pressure sensor approach of respiration measurement, from which respiration signatures and rates can be derived in real-time for long-term monitoring, are presented. Belt typed textile capacitive pressure sensor has been developed for this measurement system. the distance change of two plates by the pressure of motion has been used for the respiration measurement in chest area. Respiration rates measured with the textile capacitive pressure sensor was compared with standard techniques on 8 human subjects. Accurate measurement of respiration rate with developed sensor system is shown. The data from the method comparison study is used to confirm theoretical estimates of change in capacitance by the distance change. The current version of respiratory rate detection system using textile capacitive pressure sensor can successfully measure respiration rate. It showed upper limit agreement of $3.7997{\times}10^{-7}$ RPM, and lower limit of agreement of $-3.8428{\times}10^{-7}$ RPM in Bland-Altman plot. From all subject, high correlation were shown(p<0.0001). The proposed measurement method could be used to monitor unconscious persons, avoiding the need to apply electrodes to the directly skin or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using textile capacitive pressure sensor offers a promising possibility of convenient measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range and quality of the rate-finding, broadening the potential application areas of this technology.

데오도라이트 시스템의 측정 오차 요인에 대한 연구 (A Study on Measurement Error Factors of Theodolite System)

  • 윤용식;이동주
    • 한국공작기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.36-42
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is ${\pm}0.5mm$or better for distance 0~100m. And the system is used for the measurement of a product of middle and large scale. This study is performed for the measurement error factors of the system. We could know that the main measurement error factors are temperature, illumination and skill. Also, we performed the study for the effect according to the height difference of scale bar.