• Title/Summary/Keyword: Distance coefficient

Search Result 957, Processing Time 0.023 seconds

Curvature Linear Equation of a Coma Corrected Two-Mirror System with Finite Object Distance (유한 물체거리를 갖는 코마수차가 보정된 2 반사경계의 곡률선형방정식)

  • Hwang, Seok-Ju;Rim, Cheon-Seog;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.19-23
    • /
    • 2007
  • We derived analytically the generalized curvature linear equation useful in the initial optical design of a two-mirror system with finite object distance, including an infinite object distance from paraxial ray tracing and Seidel third order aberration theory for coma coefficient. These aberration coefficients for finite object distance were described by the curvature, the inter-mirror distance, and the effective focal length. The analytical equations were solved by using a computer with a numerical analysis method. Two useful linear relationships, determined by the generalized curvature linear equations relating the curvatures of the two mirrors, for the cancellation of each aberration were shown in the numerical solutions satisfying the nearly zero condition ($<10^{-10}$) for each aberration coefficient. These equations can be utilized easily and efficiently at the step of initial optical design of a two-mirror system with finite object distance.

Experimental Study on Coefficient of air Convection with boundary layer and boiling effects (경계층과 비등효과를 고려한 외기대류계수에 관한 실험연구)

  • Choi Myoung sung;Kim Yun Yong;Song Young Chul;Woo Sang Kyun;Kim Jin Keun;Lee Yun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.711-714
    • /
    • 2004
  • The setting and hardening of concrete is accompanied with nonlinear temperature distribution caused by development of hydration heat of cement. In order to predict the exact temperature history in concrete structures it is required to examine thermal properties of concrete. In this study, the coefficient of air convection, which presents thermal transfer between surface of concrete and air, was experimentally investigated with variables such as velocity of wind, boiling and layer effects. Finally, the prediction model for equivalent coefficient of air convection was theoretically proposed. The coefficient of air convection in the proposed model increases with velocity of wind, and its dependance on wind velocity is varied with types of form. For determining the initial coefficient of air convection, boiling effects must be considered. The coefficient of air convection is affected by boundary layer with respect to the distance from the surface.

  • PDF

Measurement of the Ionization Coefficient in Gases by the Luminous-flux Method (광속법을 이용한 기체의 전이계수 측정)

  • 백용현;하성철;이복희;김희택;김정섭
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.7
    • /
    • pp.289-296
    • /
    • 1985
  • The Townsend primary ionization coefficient a was measured by the luminous-flux method using the fact that the intensity of radiant light is proportional to electron density in the townsend discharge domain. The ranges of measurements were 15for He gas and 10

  • PDF

Evaluation of the Shielding Effect of Lead Apron according to the Energy Spectrum Change of 99mTc (99mTc의 에너지 스펙트럼 변화에 따른 납 앞치마의 차폐 효과 평가)

  • Changyong Yoon;Youngsik Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.889-896
    • /
    • 2023
  • Changes in the energy spectrum were analyzed using 99mTc as a point source and a scattering phantom, and the shielding effect of the lead apron according to the changed gamma ray energy was evaluated. In the gamma ray energy spectrum of the scattering phantom, the photo peak area decreased and the compton scattering area increased compared to the point source. The coefficients for each energy range according to the change in the shape of the gamma ray source showed a reduction rate of up to 66.1 % at a distance of 20 cm compared to the coefficient of the point source, and in the compton scattering area, the coefficient of the scattering phantom was 122.2 % at a distance of up to 40 cm compared to the coefficient of the point source. In the difference in shielding rate according to the distance between the source and the scattering phantom using a gamma camera, the photo peak area showed similar results, but in the Compton scattering area, the shielding rate of the scattering phantom at a distance of 20 cm increased by 29.2 % compared to the shielding rate of the point source. As the distance increased, the difference in shielding rate decreased. In measuring the shielding rate of the lead apron using a radiation dosimeter, the difference in the shielding rate of the scattering phantom was up to 15.3 %, and as the distance increased, the difference in the shielding rate between the two sources decreased. The shielding rate of the lead apron of the scattering phantom is higher than that of the point source, and the effectiveness of the lead apron increases as the distance to the source increases. As a result, wearing a lead apron when directly confronting a patient who has injected radioactive pharmaceuticals is expected to be helpful in reducing radiation exposure.

Effectiveness of golf skills to average score using records of PGA, LPGA, KPGA, KLPGA : Multi-group path analysis (프로골프 경기기록을 활용한 다중집단분석 : 경로분석 적용)

  • Kim, Sae Hyung;Cho, Jung Hwan
    • Journal of the Korean Data and Information Science Society
    • /
    • v.24 no.3
    • /
    • pp.543-555
    • /
    • 2013
  • This study is to analyze effectiveness of golf skills (driving distance, rating of fairway, green in regulation, sand save ratio, recovery ratio, putting average) to average score using records of PGA, LPGA, KPGA, KLPGA. Independent variables were driving distance, rating of fairway, green in regulation, sand save ratio or recovery ratio, putting average. Dependent variable was the scoring average in this study. To analyze these variables, multi-group (PGA vs LPGA, KPGA vs KLPGA, PGA vs KPGA, LPGA vs KLPGA) path analysis was used through AMOS 18.0 program and significance level was set at 0.05. As the result, the variables that show significant differences of path coefficient between PGA model and LPGA model were driving distance and green in regulation to average score. The variables that show significant differences of path coefficient between KPGA model and KLPGA model were driving distance, recovery ratio, and putting average to average score. The variables that show significant differences of path coefficient between PGA model and KPGA model were driving distance, recovery ratio, and putting average to average score. There was not significant difference of path coefficient between LPGA model and KLPGA model.

Shallow Failure Characteristics of Weathered Granite Soil Slope in accordance with the Rainfall Infiltration (강우침투에 따른 화강풍화토 사면의 얕은파괴 특성)

  • Kim, Sun-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2810-2818
    • /
    • 2009
  • In order to examine the characteristic of shallow failure in cut slopes composed of weathered granite soil, this study calculated critical permeability coefficient according to rainfall characteristic in Korea, performed stability analysis according to the representative physical properties of weathered granite soil distributed in Korea such as horizontal distance to the failure surface of cut slope, slope inclination, slope height, and the depth of wetting by rainfall, and analyzed the results. In the results of analyzing critical permeability coefficient, when the local rainfall characteristic was considered, the maximum critical permeability coefficient was $7.16{\times}10^{-4}cm/sec$. We judged that shallow failure according to wetting depth should be considered when rainfall below the critical rainfall intensity lasts longer than the minimum rainfall duration in cut slopes composed of weathered granite soil, which had a critical permeability coefficient lower than the maximum critical permeability coefficient. Furthermore, using simulated failure surface, this study could understand the characteristic of shallow failure in cut slopes based on the change in slope safety factor according to horizontal distance, wetting depth, and strength parameter.

The Real-Time Distance Relay Algorithm Using fault Location Estimation Information for Parallel Transmission Line (병행 2회선 송전선로에서 고장점 위치 추정정보를 이용한 실시간 거리계전 알고리즘)

  • 이재규;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.183-192
    • /
    • 2003
  • This paper presents the real-time implemented distance relay algorithm which the fault distance is estimated with only local terminal information. When a single-phase-to-earth fault on a two-parallel transmission line occurs, the reach accuracy of distance relay is considerably affected by the unknown variables which are fault resistance, fault current at the fault point and zero- sequence current of sound line The zero-sequence current of sound line is estimated by using the zero sequence voltage which is measured by relaying location Also. the fault resistance is removed at the Process of numerical formula expansion. Lastly, the fault current through a fault point is expressed as a function of the zero-sequence current of fault line, zero-sequence current of sound line, and line, and fault distance. Therefore, the fault phase voltage can be expressed as the quadratic equation of the fault distance. The solution of this Quadratic equation is obtained by using a coefficient of the modified quadratic equation instead of using the square root solution method. After tile accurate fault distance is estimated. the mote accurate impedance is measured by using such an information.

Improvement of Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line (웨이브렛을 이용한 혼합송전선로에서의 거리계전 알고리즘 개선)

  • 정채균;김경호;하체웅;이종범;윤양웅
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.10
    • /
    • pp.593-601
    • /
    • 2003
  • Distance realy is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding resistance, and sheath voltage limiters(SVLs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable systems, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using D1 coefficient summation in db4. And also, error compensation value was proposed for correct calculation of impedance in power cables section.

Nonparametric analysis of income distributions among different regions based on energy distance with applications to China Health and Nutrition Survey data

  • Ma, Zhihua;Xue, Yishu;Hu, Guanyu
    • Communications for Statistical Applications and Methods
    • /
    • v.26 no.1
    • /
    • pp.57-67
    • /
    • 2019
  • Income distribution is a major concern in economic theory. In regional economics, it is often of interest to compare income distributions in different regions. Traditional methods often compare the income inequality of different regions by assuming parametric forms of the income distributions, or using summary statistics like the Gini coefficient. In this paper, we propose a nonparametric procedure to test for heterogeneity in income distributions among different regions, and a K-means clustering procedure for clustering income distributions based on energy distance. In simulation studies, it is shown that the energy distance based method has competitive results with other common methods in hypothesis testing, and the energy distance based clustering method performs well in the clustering problem. The proposed approaches are applied in analyzing data from China Health and Nutrition Survey 2011. The results indicate that there are significant differences among income distributions of the 12 provinces in the dataset. After applying a 4-means clustering algorithm, we obtained the clustering results of the income distributions in the 12 provinces.

GENETICAL STUDIES ON NATIVE CHICKENS IN INDONESIA

  • Yamamoto, Y.;Namikawa, T.;Okada, I.;Nishibori, M.;Mansjoer, S.S.;Martojo, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.9 no.4
    • /
    • pp.405-410
    • /
    • 1996
  • Phylogenetic analyses were carried out using four Indonesian native chicken breeds; Kampung, Bangkok, Pelung and Kedu. Gene frequencies of four blood group (A, B, D and E) and eight electrophoretic loci (akp, Akp-2, Es-1, Amy-1, Alb, Tf, Pas and Pa-1) were examined. Geographical and breed specific trends in the gene frequencies were not found in the local population of Kampung breed or in four native breeds. The values of average heterozygosity were estimated as 0.35-0.45. Genetic distances among the local populations of Kampung breed and other native breeds were comparatively small. In a cluster analysis, the Bangkok breed and Kampung E population showed distance from another cluster. The coefficient of gene differentiation for local populations of Kampung breed was estimated as 0.099.